M & T srl medical & technology
MULTI-TECHNOLOGY PLATFORM FOR ALL AESTHETIC TREATMENTS IPL (APC) INDICATIONS Permanent Hair Reduction Skin Rejuvenation Acne vulgaris Pigmented Lesions Vascular Lesions LASERS INDICATIONS Vascular Lesions Skin Rejuvenation Fractional Skin Resurfacing Permanent Hair Reduction IPL HANDPIECES HR 630 SR 580 LP-LV 530 AC 420 HR IN MOVING LASERS TECHNOLOGIES Long Pulse Nd:YAG 1064 nm Er:YAG Fractional/Ablative 2940 nm Diode 808 nm DISCOVER YOUR ORIGINAL BEAUTY MTOne is indicated for a real wide range of applications Skin Tightening Pigmented Lesions Removal Vascular Lesions Removal Leg Veins Treatment Reduction of Enlarged Pores Permanent Hair Reduction Skin Resurfacing (fractional/ablative) Wrinkles Treatment Acne and Traumatic Scars Acne Vulgaris
IPL WITH ADAPTIVE PULSE CONTROL (APC) HYPER- SEQUENTIAL ENERGY PULSES APC technology is an advanced IPL pulse control system for the automatic selection of the best treatment configuration. This feature considers each of the conditions to be treated and adjust the right pulse sequence along with the energy needed for a safe and effective treatment. With APC, operators can acquire more rapidly and safely the experience to perform excellent and fully satisfactory treatments to their customers. pulse pulse pulse pulse temperature damage threshold hair temperature skin temperature EXTREMELY EFFECTIVE AND SAFE The State-of-Art APC technology with different pulse and wavelength configurations, combined with the powerful contact skin cooling and sapphire waveguide, is able to perform comfortable and effective treatments in all skin conditions. The handpieces have different optical filters for the delivery of the best range of wavelengths for each treatment, the skin cooling is able to keep a very low temperature even during the In Moving procedures and allows treatments without the use of gel, so that, the operator has always the ideal treatment conditions. MTOne with IPL handpieces has three different configurations for the energy emission to fit perfectly the needs of all difficult treatment conditions such as thin hairs or dark skins. All pulse configurations has a special smooth shape for the delivery of flat top waves with no spikes for safer treatments also on dark skins.
REGULAR PULSE Ideal for dark skin, dark and thick hair, skin damaged by sun exposure or age, and for pigmented and dark vascular lesions. LONG ADAPTIVE PULSE For average skin types, brown hair of medium thickness and vascular lesions. HIGH ADAPTIVE PULSE For light skin, light thin hairs, small benign vascular lesions and light benign pigmented lesions. HR IN MOVING THE SOLUTION FOR PAINLESS HAIR REDUCTION TREATMENTS The HR IN MOVING handpiece is for the inhibition of hair regrowth using really fast sequences of pulses. This procedure is especially suitable for treatments on dark and on tanned skins.
THE MTONE LASER TECHNOLOGIES ERGONOMIC AND WEIGHTLESS HANDPIECES Accessories have been designed specifically for easy and accurate face and body application. FASTER THROUGHPUT Each handpiece includes various spots sizes for best accuracy of applications and for faster treatments. VERSATILE COMBINATIONS MT-ONE platform combines lasers and APC technologies to improve clinical efficacy. Er:YAG 2940 It is designed to perform ablation procedures both fractional and homogeneous. The Er:YAG laser @ 2940 nm is able, through the variation of pulse parameters, to remove layers of skin with minimal thermal damage or produce higher coagulation suitable for the stimulation of collagen production. Nd:YAG 1064 This laser handpiece has been developed for safe and effective vascular lesions treatments, useful for non-ablative treatments and firming of face. DIODE 808 It is the ideal laser for permanent hair reduction, thanks to the extreme tolerability and efficacy. This Diode can perform treatments in traditional single shot and in the no-pain in moving modes. Pain free The fastest available on market Cooled tip up to -4 C High efficiency up to 10 Hz
APC TECHNOLOGY Application Handpiece Energy J/cm 2 Pulse width msec Spot Size cm 2 Hair removal HR630 5-25 15-100 6,5 in moving 635 In moving hair removal 1,1 milion pulse 5-9 6 6,5 Face skin resurfacing SR580 5-25 10-25 6,5 Vascular and pigmented lesions LP530 5-25 10-25 6,5 Acne AC420 5-15 15-100 6,5 LASER TECHNOLOGY Application Handpiece Energy J/pulse Pulse width msec Spot Size Ø mm Skin resurfacing Er:YAG 2940 15mJ/dotØ9mm fractional 56mJ/dotØ2,5mm 1-1,2-1,5 2,5-4-7-9 Vein removal LP Nd:YAG 1064 30-150J/cm 2 from 10 to 100 6 Diode hair removal Diode 808 5-110 from 10 to 100 TECHNICAL SPECIFICATIONS Electrical requirements Dimensions and weight Interface 100-240V; 50/60 Hz; max 10A 580 W x 450 D x 1000 H mm; 45 Kg 10,1 Colour Touch screen M & T srl medical & technology TECHNOLOGICAL SYSTEMS FOR THE MEDICINE AND THE AESTHETIC Reg. n.5896-a - Norma UNI EN ISO 9001:2008 Reg. n.5896-m - Norma UNI EN ISO 13485:2004 CAUTION - Laser radiation Production Via Pietrarubbia, 32F 47922 RIMINI Tel. +39.0541.727486 Fax +39.0541.765305 Commercial division Via degli Olmetti, 18 00060 Formello ROMA Tel. +39 06.9075542 Fax +39 06.90409208 www.medical-technology.it - www.eporex.net info@medical-technology.it - francescalapenna@medical-technology.it