Endocardial radiofrequency (RF) ablation is the common

Similar documents
Case Report Mapping and Surgical Ablation of Focal Epicardial Left Ventricular Tachycardia

Ablation of Ventricular Tachycardia in Non-Ischemic Cardiomyopathy

Title. CitationJournal of Electrocardiology, 43(5): Issue Date Doc URL. Type. File Information.

Cardiovascular Surgery

ECG Criteria to Identify Epicardial Ventricular Tachycardia in Nonischemic Cardiomyopathy

Mechanism of Ventricular Tachycardia Termination by Pacing at Left Ventricular Sites in Patients with Coronary Artery Disease

Ablative Therapy for Ventricular Tachycardia

Sustained monomorphic ventricular tachycardia (VT) due to

Ventricular Tachycardia Substrate. For the ablationist. Stanley Tung, MD FRCPC Arrhythmia Service/St Paul Hospital University of British Columbia

Long-Term Follow -Up After Radiofrequency Catheter Ablation of Fascicular Ventricular Tachycardia at National Institute of Cardiovascular Diseases

Characteristics of systolic and diastolic potentials recorded in the left interventricular septum in verapamil-sensitive left ventricular tachycardia

Conventional Mapping. Introduction

II V 1 HRA 3 4 HB 5 6 HB 3 4 HB 1 2 CS 7 8 CS 5 6 CS 3 4 CS 1 2 ABL 3 4 ABL 1 2 RVA 3 4. T. Suga et al.

Basic Electrophysiology Protocols

ΔΠΔΜΒΑΣΙΚΗ ΘΔΡΑΠΔΙΑ ΚΟΙΛΙΑΚΩΝ ΑΡΡΤΘΜΙΩΝ

Urgent VT Ablation in a Patient with Presumed ARVC

Intramural Reentrant Ventricular Tachycardia in a Patient with Severe Hypertensive Left Ventricular Hypertrophy

Catheter Ablation of VT Without Structural Heart Disease 성균관의대 온영근

Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations

Original Article. Introduction. Korean Circulation Journal

Ablation of Left Ventricular Epicardial Outflow Tract Tachycardia From the Distal Great Cardiac Vein

Electroanatomic Substrate and Outcome of Catheter Ablative Therapy for Ventricular Tachycardia in Setting of Right Ventricular Cardiomyopathy

Anodal Capture in Cardiac Resynchronization Therapy Implications for Device Programming

Advances in Ablation Therapy for Ventricular Tachycardia

Reentrant Ventricular Tachycardia Originating in the Right Ventricular Outflow Tract

Analysis During Sinus Rhythm of Critical Sites in Reentry Circuits of Postinfarction Ventricular Tachycardia

Use of Catheter Ablation in the Treatment of Ventricular Tachycardia Triggered by Premature Ventricular Contraction

Case Report Epicardial Ablation: Prevention of Phrenic Nerve Damage by Pericardial Injection of Saline and the Use of a Steerable Sheath

Epicardial Approach to Mapping and Ablation of VT: Clinical and ECG Predictors of Epicardial Location

Case Report What Next After Failed Septal Ventricular Tachycardia Ablation?

Ventricular tachycardia ablation

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Case Report Substrate Based Ablation of Ventricular Tachycardia Through An Epicardial Approach

Novel ECG Predictor of Difficult Cases of Outflow Tract Ventricular Tachycardia:

Declaration of conflict of interest NONE

Results of Catheter Ablation of Ventricular Tachycardia Using Direct Current Shocks

Journal of the American College of Cardiology Vol. 37, No. 2, by the American College of Cardiology ISSN /01/$20.

Novel Approaches to VT Management Glenn M Polin MD

EHRA EUROPACE How to perform epicardial ventricular tachycardia mapping and ablation

INTRODUCTION. left ventricular non-compaction is a sporadic or familial cardiomyopathy characterized by

Ventricular Arrhythmias

Medicine. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract

NAAMA s 24 th International Medical Convention Medicine in the Next Decade: Challenges and Opportunities Beirut, Lebanon June 26 July 2, 2010

Title. CitationJournal of electrocardiology, 46(6): Issue Date Doc URL. Type. File Information

Circulation: Arrhythmia and Electrophysiology CHALLENGE OF THE WEEK

CATHETER ABLATION FOR TACHYCARDIAS

Management of patients with ventricular

The Efficient and Smart Methods for Diagnosis of SVT 대구파티마병원순환기내과정병천

Septal Involvement in Patients With Post-Infarction Ventricular Tachycardia

Successful treatment of tachycardia-induced cardiomyopathy secondary to dual atrioventricular nodal nonreentrant tachycardia using cryoablation

Map-Guided Ablation of Non-ischemic VT. Takashi Nitta Cardiovascular Surgery, Nippon Medical School Tokyo, JAPAN

Case Report Catheter Ablation of Long-Lasting Accelerated Idioventricular Rhythm in a Patient with Mild Left Ventricular Dysfunction

Septal ventricular arrhythmias in the presence of structural

Case Report Catheter ablation of ventricular tachycardia related to a septo-apical left ventricular aneurysm

Technique of Epicardial VT Ablation

Journal of the American College of Cardiology Vol. 61, No. 20, by the American College of Cardiology Foundation ISSN /$36.

Epicardial VT Ablation The Cleveland Clinic Experience

Catheter Ablation of Atrial Tachycardia Originating from the Tip of Right Atrial Appendage

Chapter 16: Arrhythmias and Conduction Disturbances

Case Report Coexistence of Atrioventricular Nodal Reentrant Tachycardia and Idiopathic Left Ventricular Outflow-Tract Tachycardia

Electrophysiology of Ventricular Tachycardia: A Historical Perspective

VENTRICULAR TACHYCARDIA IN THE ABSENCE OF STRUCTURAL HEART DISEASE

Noncontact mapping to idiopathic VT from LCC

Radiofrequency Catheter Ablation in a Patient with Tachycardiomyopathy due to Incessant Fascicular Tachycardia

Πρώτης γραμμή θεραπεία η κατάλυση κοιλιακής ταχυκαρδίας στην ισχαιμική μυοκαρδιοπάθεια

Effect of Epicardial Fat on Electroanatomical Mapping and Epicardial Catheter Ablation

Unusual Tachycardia Association In A patient Without Structural Heart Disease

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

December 2018 Tracings

Mini-Electrodes Help Identify Hidden Slow Conduction. during Ventricular Tachycardia Substrate Ablation

Purkinje-related Arrhythmias

Catheter ablation of monomorphic ventricular tachycardia. Department of Cardiology, IKEM, Prague, Czech Republic

The left ventricular outflow tract (LVOT) is the most common. Original Article

Methods. Circ J 2006; 70:

Determination of Inadvertent Atrial Capture During Para-Hisian Pacing

Ventricular Tachycardia Ablation. Saverio Iacopino, MD, FACC, FESC

Editorial Mapping for the Target Sites of Ablation in Post-infarction Ventricular Tachycardia- Is Sinus Rhythm Sufficient?

Figure 2. Normal ECG tracing. Table 1.

Epicardial Ventricular Tachycardia Ablation

Phase 2 Early Afterdepolarization as a Trigger of Polymorphic Ventricular Tachycardia in Acquired Long-QT Syndrome

Isolated Potentials and Pace-Mapping as Guides for Ablation of Ventricular Tachycardia in Various Types of Nonischemic Cardiomyopathy

Idiopathic Left Ventricular Tachycardia Originating from the Mitral Annulus

Dialysis-Dependent Cardiomyopathy Patients Demonstrate Poor Survival Despite Reverse Remodeling With Cardiac Resynchronization Therapy

By the end of this lecture, you will be able to: Understand the 12 lead ECG in relation to the coronary circulation and myocardium Perform an ECG

CLINICAL INVESTIGATIONS. Methods

Abnormalities Caused by Left Bundle Branch Block

Transcoronary Chemical Ablation of Atrioventricular Conduction

Ventricular Tachycardia in Normal Heart: Approach and Management

How to Ablate Atrial Tachycardia Mechanisms and Approach. DrJo Jo Hai

Lect.6 Electrical axis and cardiac vector Cardiac vector: net result Vector that occurs during depolarization of the ventricles Figure:

Tachy. Induction tachycardia lead ECG during Tachy /25/2009. Sinus Rhythm Single His

12-Lead ECG Interpretation. Kathy Kuznar, RN, ANP

that number is extremely high. It s 16 episodes, or in other words, it s 14, one-four, ICD shocks per patient per day.

How to ablate typical slow/fast AV nodal reentry tachycardia

480 April 2004 PACE, Vol. 27

Ankara, Turkey 2 Department of Cardiology, Division of Arrhythmia and Electrophysiology, Yuksek Ihtisas

Ablation of Ventricular Tachycardia in Patients with Structural Heart Disease

Pre-excited tachycardia: Atrial tachycardia with a bystander left lateral accessory pathway

Since pulmonary veins (PVs) have

Transcription:

Electrocardiographic Recognition of the Epicardial Origin of Ventricular Tachycardias Antonio Berruezo, MD; Lluis Mont, MD; Santiago Nava, MD; Enrique Chueca, MD; Eduardo Bartholomay, MD; Josep Brugada, MD, PhD Background Some ventricular tachycardias (VTs) originating from the epicardium are not suitable for endocardial radiofrequency ablation and require an epicardial approach. The aim of this study was to define the ECG characteristics that may identify an epicardial origin of VTs. Methods and Results We analyzed the 12-lead ECG recordings during epicardial and endocardial left ventricular pacing in 9 patients to verify the hypothesis that the epicardial origin of the ventricular activation widens the initial part of the QRS complex. Then, we analyzed the ECG pattern in 14 VTs successfully ablated from the epicardium after a failed endocardial approach (group A), in 27 VTs successfully ablated from the endocardium (group B), and in 28 additional VTs that could not be ablated from the endocardium (group C). Four distinct intervals of ventricular activation were defined and measured: (1) the pseudodelta wave, (2) the intrinsicoid deflection time in V2, (3) the shortest RS complex, and (4) the QRS complex. VTs from groups A and C showed a significantly longer pseudodelta wave, intrinsicoid deflection time, and RS complex duration compared with VTs of group B. There was no difference between groups A and C. A pseudodelta wave of 34 ms has a sensitivity of 83% and a specificity of 95%, an intrinsicoid deflection time of 85 ms has a sensitivity of 87% and a specificity of 90%, and an RS complex duration of 121 ms has a sensitivity of 76% and a specificity of 85% in identifying an epicardial origin of the VTs. Conclusions ECG suggests VTs originating from the epicardium and those with an unsuccessful radiofrequency ablation from the endocardium. (Circulation. 2004;109:1842-1847.) Key Words: electrocardiography pericardium tachycardia, ventricular Endocardial radiofrequency (RF) ablation is the common approach for ablation of monomorphic sustained ventricular tachycardias (VTs). However, the success rate of the procedure depends on the underlying heart disease and the location of the circuit. Efficacy of RF ablation of VTs ranges from 45% to 76% in patients with ischemic heart disease 1-3 to 100% in patients with fascicular or bundle-branch block reentry tachycardias 4-6 in which a crucial part of the reentrant circuit of the tachycardia is the conduction system, located in the subendocardium. The reasons for failure of endocardial ablation are often difficult to ascertain. One proposed explanation is that the reentry circuits may be located deep in the subendocardium or in the epicardium, making them inaccessible to current ablation techniques. 7,8 Epicardial mapping of arrhythmia foci or circuits has been attempted in open chest surgery 9,10 and with RF ablation catheters. 11,12 These studies suggest that the slow conduction zone may be located subepicardially in up to 33% of patients. We recently described the feasibility and safety of nonsurgical transthoracic epicardial RF ablation of VTs in patients with ischemic heart disease, incessant VT, and depressed ventricular ejection fraction in whom classic endocardial ablation had failed. The observed success rate was 85%. 13 These results suggest that the use of an epicardial approach may improve the success rate of VT ablation in case of an epicardial origin of the arrhythmia. In 1990, Burgess et al 14 and later Oster et al 15 demonstrated the ability of ECG imaging to estimate the depth of intramyocardial electrophysiological events in experimental studies in dogs and their relation to the velocity of propagation of activation (more rapid along the endocardium, with the aid of the Purkinje system). However, no ECG criteria to predict an epicardial origin of VTs have been described to date. On the other hand, no reliable criteria have been proposed to identify these tachycardias from mapping data restricted to the endocardial surface. 16 The aim of the present study was to analyze the ECG pattern of VTs ablated from the epicardium and to define the ECG characteristics that may predict an epicardial origin. Previously, we tested the hypothesis that the epicardial origin of the ventricular activation may increase the duration of the initial part of the QRS complex on the surface ECG with respect to an endocardial origin. Received July 18, 2003; de novo received November 8, 2003; revision received January 27, 2004; accepted February 2, 2004. From the Arrhythmia Section, Cardiovascular Institute, Hospital Clinic, University of Barcelona, Barcelona, Spain. Correspondence to Josep Brugada, MD, Arrhythmia Section, Cardiovascular Institute, Hospital Clínic, Villarroel 170, 08036, Barcelona, Spain. E-mail jbrugada@clinic.ub.es 2004 American Heart Association, Inc. Circulation is available at http://www.circulationaha.org DOI: 10.1161/01.CIR.0000125525.04081.4B 1842

Berruezo et al ECG Pattern in Epicardial VT 1843 Figure 1. Fluoroscopic images [right (RAO) and left anterior oblique (LAO)] recorded during placement of diagnostic quadripolar 6F catheter on endocardial surface close to epicardial catheter. Measured distance between endocardial and epicardial electrode tips is 10 mm. Recordings obtained during endocardial and epicardial pacing in this patient are shown in Figure 3 (right). Methods Paced Patients Nine consecutive patients in NYHA functional class III/IV (mean age, 55 19 years; left ventricular ejection fraction, 24 7%) in whom a cardiac resynchronization therapy device with possible right and left ventricular independent pacing (Guidant Contak Renewal 2) was implanted underwent electrophysiological study perioperatively. No patient was on antiarrhythmic drugs during the study. The pacing protocol was performed after written informed consent was obtained. The epicardium of the left ventricular free wall was paced at a cycle length of 600 ms through the epicardial electrode of the device placed at the distal venous system. Afterward, the endocardial aspect of the left ventricular free wall was paced at a similar site and at the same cycle length with a diagnostic deflectable 6F catheter. Multiple fluoroscopic positions were used to obtain optimal position of the endocardial catheter, ideally 10 mm away from the tip of the epicardial catheter (Figure 1). The stimuli were delivered in a bipolar configuration at twice the diastolic threshold and 2-ms duration. Data from the 12 surface ECG leads and endocardial signals were recorded concurrently. VT Patients We analyzed the 12-lead surface ECGs of 14 clinical VTs with right bundle-branch block (RBBB) morphology (group A) that were unsuccessfully ablated from the endocardium despite the use of standard and special catheters (8-mm tip in 6 patients, endocardial irrigated tip in 3 patients) and effectively ablated from the epicardium with a nonsurgical transthoracic epicardial approach. In addition, we analyzed a second group of 25 consecutive patients with 27 clinical VTs with an RBBB morphology successfully ablated from the endocardium (group B). VTs with left bundle-branch block pattern in V1 (dominant S wave) were excluded because these tachycardias commonly originate from the interventricular septum and are probably not suitable for epicardial access. 5 Finally, another group of 24 patients with 28 VTs with an RBBB morphology that could not be ablated from the endocardium in whom no epicardial approach was used was retrospectively included for analysis (group C). Figure 2 shows the epicardial and endocardial locations of successful ablation sites for each patient in groups A and B. The target sites were identified initially by activation mapping. Pacing maneuvers to identify the mechanism were done, including reset, entrainment, concealed entrainment, and pace mapping. In all cases, the nature of the VT was suggested to be reentrant. Point applications were used for ablation. Most cases required a few close applications to terminate the VT. Electrophysiological Study All patients gave written informed consent for the procedures. The electrophysiological study was performed in patients in the fasting Figure 2. Endocardial and epicardial location of successful ablation site. A, Anterior (a) and posterior (p) views of epicardially ablated VTs. B, Endocardially ablated VTs. state who were mildly sedated with 10 mg diazepam. Before the study, 9, 17, and 16 patients were receiving oral amiodarone in groups A, B, and C, respectively. All other antiarrhythmic drugs were stopped at least 5 half-lives before the procedure. The technique used for epicardial mapping and ablation has been already reported. 13,17 The equipment used for recording was an EP-TRACER (Cardio Tek bv). The 12 surface ECG leads, distal and proximal bipolar electrograms of the epicardial ablation catheter, and endocardial signals from a diagnostic catheter positioned at the right ventricular apex were displayed. Analysis of the ECG For the purposes of this study, 4 distinct intervals of ventricular activation were defined. The intervals were measured using digitized tracings with calipers allowing 1-ms resolution at a screen velocity of 100 mm/s and with the signal amplified at 10 mm/mv. Two observers blinded to the pacing site or successful ablation location made all measurements. In case of discordance of 5 ms in a given measure between observers, a third observer was used. Pseudodelta Wave The pseudodelta (pseudo ) was measured from the earliest ventricular activation (from the stimulation artifact in paced patients) to the earliest fast deflection in any precordial lead. In paced patients, we measured also the transmural activation time, from the stimulation artifact in the epicardium to the largest rapid deflection recorded from the distal bipolar electrogram of the endocardial surface catheter 5 (Figure 3). Intrinsicoid Deflection Time The intrinsicoid deflection time was defined as the interval measured from the earliest ventricular activation (from the stimulation artifact in paced patients) to the peak of the R wave in V2. Shortest RS Complex The shortest RS complex was defined as the interval measured from the earliest ventricular activation (from the stimulation artifact in paced patients) to the nadir of the first S wave in any precordial lead. QRS Complex Duration The QRS complex duration was defined as the interval measured from the earliest ventricular activation (from the stimulation artifact in paced patients) to the offset of QRS in the precordial leads.

1844 Circulation April 20, 2004 Figure 3. Recordings obtained during endocardial and epicardial pacing. A, Pacing from distal bipole of endocardial surface catheter. B, Pacing from epicardial electrode and recording from distal bipole of endocardial surface catheter. Left, Patient with nonischemic cardiomyopathy. This patient had large basal QRS complex duration (200 ms) and very dilated left ventricle (end-diastolic diameter, 112 mm; end-systolic diameter, 95 mm; ejection fraction, 15%). Right, Patient with ischemic cardiomyopathy. This patient had duration of basal QRS complex of 183 ms and less dilated left ventricle (end-diastolic diameter, 57 mm; end-systolic diameter, 40 mm; ejection fraction, 35%). Statistical Analysis Continuous data are expressed as mean SD. Means were compared by use of Student s t test for paired data and 1-way ANOVA when appropriate. Receiver-operating characteristic curves were made to obtain the best values of sensitivity and specificity. Statistical analysis was performed with the SPSS 10.0 statistical package. A value of P 0.05 was considered significant. Results Epicardial Pacing Dependent Widening of QRS In this group of patients, the baseline QRS complex duration averaged 194 19 ms, attributable to left bundle-branch block. The sites of endocardial and epicardial stimulation during the pacing protocol were as follows: lateral (basal or medial) in 6 patients, lateroapical in 2 patients, and anterior in 1 patient. The mean threshold value at 2-ms duration of TABLE 1. Characteristics and Results of the Measured Intervals in Paced Patients Pacing stimuli was 1.4 1.2 V for epicardial pacing and 0.5 0.1 V for endocardial pacing. Epicardial pacing showed longest activation times (Table 1) compared with endocardial pacing despite a very similar morphology of the QRS complex (Figure 3). There was a small but significant increase in epicardially paced QRS complex duration (241 39 versus 266 25 ms; 12 13% increment; P 0.012). However, epicardial pacing led to a marked prolongation of the shortest RS interval (138 37 versus 183 37 ms; P 0.001), intrinsicoid deflection time in V2 (98 33 versus 138 38 ms; P 0.001), and pseudo wave (20 14 versus 65 13 ms; P 0.001). Of note, the absolute increase in milliseconds was similar (45 14 ms for the shortest RS interval, 40 24 ms for the intrinsicoid deflection in V2, 45 6 ms for the pseudo wave). Endocardial Epicardial P Widening, ms Widening, % n 9 Age, y 55 19 Ischemic, n 6 LVEF, % 24 7 LVEDD, mm 80 23 Wall thickness, mm 10.4 1.5 Pseudo wave, ms 20 14 65 13 0.001 45 6 ID time in V2, ms 98 33 138 38 0.001 40 24 49 37 Shortest RS interval, ms 138 37 183 37 0.001 45 14 36 16 QRS complex duration, ms 241 39 266 25 0.012 26 21 12 13 LVEF indicates left ventricular ejection fraction; LVEDD, left ventricular end-diastolic diameter; and ID, intrinsicoid deflection.

Berruezo et al ECG Pattern in Epicardial VT 1845 TABLE 2. of VT Main Characteristics of Patients in the 3 Groups Group A Group B Group C Age, y 69 7 65 16 69 8 Cardiopathy (ischemic/dilated), % 90/10 64/36 65/35 Infarct location (anterior/inferior), % 33/66 48/52 42/58 LVEF, % 30 8 36 9 36 10 VT cycle length, ms 430 76 416 88 409 80 LVEF indicates left ventricular ejection fraction. ANOVA: group A vs B and group C vs B, P 0.05; group A vs C, P NS. 2 test: P NS. The duration of the pseudo wave when the ventricle was paced from the epicardium matched the transmural activation time measured from the stimulation artifact to the local activation time on the distal bipolar electrogram from the endocardial diagnostic catheter (Figure 3). Intervals in VTs Table 2 gives the main characteristics of patients in the 3 VT groups. Data on intervals measured on the 3 groups (a total of 69 VTs) are given in Table 3. Epicardially ablated VTs with RBBB morphology (group A) showed a mean duration of pseudo wave of 43 9 ms. However, the mean duration of pseudo wave in the 27 VTs with RBBB morphology successfully ablated from the endocardial aspect (group B) was 16 9 ms(p 0.05). In the 28 VTs with RBBB morphology that could not be ablated from the endocardium (group C), the mean duration of pseudo wave (42 9 ms) was similar to that of group A, and both groups differed from group B (group A versus B and C versus B, P 0.05; group A versus C, P NS). The same differences between groups were observed when the intrinsicoid deflection time in V2 and the shortest RS interval were compared. The mean duration was 97 21 and 149 39 ms in group A, 65 15 and 91 20 ms in group B, and 98 14 ms and 132 30 ms in group C, respectively (group A versus B and C versus B, P 0.05; group A versus C; P NS). The differences between all 3 groups with respect to the QRS interval duration were small but statistically significant: 217 24 ms from group A, 174 37 ms from group B, and 195 27 ms from group C (group A versus B and C versus B, P 0.05; group A versus C, P NS). Thus, epicardially ablated VTs (group A) showed longer intervals compared with endocardially ablated VTs (group B), (P 0.05), and there were no differences between groups A and C. An TABLE 3. of VT Results of the Measured Intervals in the 3 Groups Group A Group B Group C Pseudo wave, ms 43 9 16 9 42 9 ID time in V2, ms 97 21 65 15 98 14 Shortest RS interval, ms 149 39 91 20 132 30 QRS complex duration, ms 217 24 174 37 195 27 ID indicates intrinsicoid deflection. ANOVA: group A vs B and group C vs B, P 0.05; group A vs C, P NS. example of intervals in VTs from each group is shown in Figure 4. Receiver-operating characteristic curves showed that a mean duration of the pseudo wave of 34 ms has a sensitivity of 83% and a specificity of 95%, the intrinsicoid deflection time of 85 ms has a sensitivity of 87% and a specificity of 90%, and an RS complex duration of 121 ms has a sensitivity of 76% and a specificity of 85% to predict the failure of endocardial RF ablation of VTs. Discussion Paced Patients This study demonstrates that epicardial pacing produces a widening of the QRS complex as a result of the initial part (pseudo wave) compared with endocardial pacing at a similar location of the left ventricular free wall. Interestingly, the transmural activation time matches the duration of the visible pseudo wave in the 12-lead surface ECG. Its interval was 45 ms in these patients. In fact, the visible early fast deflection on the simultaneous 12-lead surface ECG corresponds with the local activation time measured on the distal bipolar electrogram of the diagnostic catheter positioned at the endocardial surface. It is possible that the duration of the pseudo wave in another cohort of patients (absence of cardiomyopathy, distinct wall thickness) may be different. The differences between endocardially and epicardially stimulated QRS are probably due to fast depolarization of the ventricles along the specialized conducting system when the stimulus is delivered in the endocardium, resulting in a narrow QRS on the surface ECG and the absence of a pseudo wave. When initial activation occurs in the epicardium, the intramyocardial delay of conduction produces a slurred initial part of the QRS complex (pseudo wave). Some discordance exists between the absolute value of the measured intervals in paced patients with respect to the VT patients. Some factors may play a role in this discordance. First, measurements have been performed from the spike, so the latency interval between the stimulus artifact and the onset of the QRS complex is included. Second, the paced patients are not comparable with the VT patients because the former showed an extremely enlarged cavity size and a very damaged conduction system. These factors may modify the intervals. Third, the onset of activation came indubitably from the epicardium in paced patients, whereas in group A patients (and inversely in group B), it came from near the epicardium, far from the endocardium, or deep into the left ventricular wall. For all these reasons, the values obtained in the paced patients are used only to demonstrate the hypothesis that epicardial pacing enlarges the initial duration of the QRS in each individual patient but cannot be used in absolute terms to validate the data to identify an epicardial origin of a VT. VT Patients Several factors affect the QRS width of VTs, ie, muscle mass or nonuniform anisotropy. Also, the His-Purkinje system plays an important role in impulse propagation in the VTs, and in occasional patients, investigators have been able to document morphologically similar tachycardias with differ-

1846 Circulation April 20, 2004 Figure 4. Example of intervals measured in VTs from each group. VTs unsuccessfully ablated from endocardium (groups A and C) show longer intrinsicoid deflection in V2 and slurred initial part of QRS (pseudo wave) vs endocardially ablated VT (group B). ent QRS widths. In such cases, the QRS width appears to be related to His-Purkinje activation and its participation in global left ventricular depolarization. 18 As far as we know, the extent to which intramural conduction delay contributes to QRS widening in the 12-lead ECG recording in VTs has never been assessed. Thus, this study also demonstrated how it is possible to recognize an epicardial origin of left ventricular free wall VTs by the ECG analysis of QRS activation times. In VTs successfully ablated from the endocardium, there is not a visible pseudo wave on the ECG or the pseudo wave has a short duration (16 9 ms). In the same way, both the intrinsicoid deflection in V2 and the shortest RS complex have a shortest duration compared with epicardially ablated VTs. On the other hand, VTs that could not be ablated from the endocardium (group A and C) had the longest activation times. In these VTs, a duration of pseudo wave of 34 ms and duration of intrinsicoid deflection in V2 of 85 ms provided a high sensitivity (83% and 87%, respectively) and specificity (95% and 90%, respectively). Nonsurgical transthoracic epicardial ablation of VTs is a safe and feasible procedure, and only a small percentage of complications have been encountered. The high success rate of this approach (85% of attempted VTs in a recent series) is probably due to the selection of cases that could not be ablated previously from the endocardium. 14 The proposed criteria have a high sensitivity and specificity in the analyzed group and provide a diagnostic tool that may help to decide the use of this approach as a first intention (aortic stenosis or prosthetic valves, recent intraventricular thrombus, high risk of bleeding, or severe artery disease). Furthermore, a VT selection based on the proposed criteria may increase the success of the epicardial ablation. Study Limitations It is possible that in VTs with a very short cycle length, the repolarization of the previous beat may cover the onset of the next QRS. However, such tachycardias are often not suitable for ablation because of poor hemodynamic tolerance. To minimize subjectivity in the measurements, simultaneous 12-lead ECG recordings were used to facilitate recognition of onset of intervals. However, sometimes it is difficult to measure the duration of the pseudo wave; in these cases, measurement of the intrinsicoid deflection in V2 and of the shortest RS interval is much easier and more reliable. The proposed criteria are valid only for VTs with an RBBB morphology. Prediction of the epicardial origin of VTs with left bundle-branch block morphology is of minor interest because a high percentage of these tachycardias originate from the interventricular septum and are probably not suitable for ablation from the epicardium. One final limitation is the fact that irrigated tip catheters were not available in most patients with endocardial ablation failure retrospectively analyzed. Theoretically, some of these VTs could have been ablated from the endocardium with deeper lesions. However, the intervals measured in this group (group C) are the same as those of VTs ablated from the epicardium and unsuccessfully ablated from the endocardium

Berruezo et al ECG Pattern in Epicardial VT 1847 and provide the gold standard to characterize and compare the epicardial origin. Conclusions The epicardial origin of activation produces a widening of the initial part of the QRS, visible in the conventional surface ECG as a pseudo wave. Analysis of the conventional ECG suggests VTs originating from the epicardium and those with an unsuccessful ablation from the endocardium with a high sensitivity and specificity. References 1. Morady F, Harvey M, Kalbfleisch SJ, et al. Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease. Circulation. 1993;87:363 372. 2. Gonska BD, Cao K, Schauman A, et al. Catheter ablation of ventricular tachycardia in 136 patients with coronary artery disease: results and long-term follow-up. J Am Coll Cardiol. 1994;24:1506 1511. 3. Stevenson WG, Friedman PL, Kocovic D, et al. Radiofrequency catheter ablation of ventricular tachycardia after myocardial infarction. Circulation. 1998;98:308 314. 4. Nakagawa H, Beckman KJ, McClelland JH, et al. Radiofrequency catheter ablation of idiopathic left ventricular tachycardia guided by a Purkinje potential. Circulation. 1993;88:2607 2617. 5. Josephson ME. Clinical Cardiac Electrophysiology. Techniques and Interpretations. 3rd ed.. Philadelphia, Pa: Lippincott Williams and Wilkins; 2002. 6. Ouyang F, Cappato R, Ernst S, et al. Electroanatomic substrate of idiopathic left ventricular tachycardia: unidirectional block and macroreentry within the Purkinje network. Circulation. 2002;105:462 469. 7. Kaltenbrunner W, Cardinal R, Dubuc M, et al. Epicardial and endocardial mapping of ventricular tachycardia in patients with myocardial infarction: is the origin of the tachycardia always subendocardially localized?. Circulation. 1991;84:1058 1071. 8. Blanchard SM, Walcott GP, Wharton JM, et al. Why is catheter ablation less successful than surgery for treating ventricular tachycardia that results from coronary artery disease?. Pacing Clin Electrophysiol. 1994; 17:2315 2335. 9. Fontaine G, Guiraudon G, Frank R, et al. Le cartographie epicardique et le traitement chirurgical par simple ventriculotomie de certaines tachycardies ventriculaires rebelles par reentree. Arch Mal Coeur. 1975;68: 113 124. 10. Svenson RH, Littmann L, Gallagher JJ, et al. Termination of ventricular tachycardia with epicardial laser photocoagulation: a clinical comparison with patients undergoing successful endocardial photocoagulation alone. J Am Coll Cardiol. 1990;15:163 170. 11. Stellbrink C, Diem B, Schauerte P, et al. Transcoronary venous radiofrequency catheter ablation of ventricular tachycardia. J Cardiovasc Electrophysiol. 1997;8:916 921. 12. Sosa E, Scanavacca M, d Avila A, et al. Nonsurgical transthoracic epicardial catheter ablation to treat recurrent ventricular tachycardia occurring late after myocardial infarction. J Am Coll Cardiol. 2000;35: 1442 1449. 13. Brugada J, Berruezo A, Cuesta A, et al. Nonsurgical transthoracic epicardial radiofrequency ablation: an alternative in incessant ventricular tachycardia. J Am Coll Cardiol. 2003;41:2036 2043. 14. Burgess MJ, Lux RL, Ershler PR, et al. Determination of transmural location of onset of activation from cardiac surface electrograms. Circulation. 1990;82:1335 1342. 15. Oster HS, Taccardi B, Lux R, et al. Electrocardiographic imaging: noninvasive characterization of intramural myocardial activation from inverse reconstructed epicardial potentials and electrograms. Circulation. 1998;97:1496 1507. 16. Lacroix D, Klug D, Marquié C, et al. Identification of ventricular tachycardia of epicardial origin from unipolar potentials obtained at the endocardial surface. Pacing Clin Electrophysiol. 2002;25:1561 1570. 17. Sosa E, Scanavacca M, d Avila A, et al. A new technique to perform epicardial mapping in the electrophysiology laboratory. J Cardiovasc Electrophysiol. 1996;7:531 539. 18. Josephson ME, Miller JM. Endocardial and epicardial recordings: correlation of twelve-lead electrocardiograms at the site of origin of ventricular tachycardia. Ann N Y Acad Sci. 1990;601:128 147.