tide germany (2J ['..) ~.- Model Barbara / BA 914 Instruction Manual Directory

Similar documents
Body Balance Shape F3

Contents Safety Instructions... 4 Package Contents... 6 Notes on Measurements... 7

MD10826_Körperfettwaage_manual_UK.fm Seite 1 Mittwoch, 26. Juli :10 14

Weight And Body Fat! Why do I lose weight but my body fat doesn t change much? Scales by How does it work? Is it accurate?

Body Balance Slim Design FT 5

BODY ANALYZER SCALE PS 8710

Contents. Helpline No. UK/ North Ireland Rep. Ireland Web Support Model Number: 12005

Body Fat Monitor / Scale Model: UM-040/041 Instruction Manual

Precision GetFit. Digital Body Fat Bathroom Scale. EatSmart Products Seattle, WA

MERCURY SL. User Manual. MSL-180 (396lb x 0.2lb) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.1

Body Fat Scales. instruction manual. with body analysis functionality. Model Number BF801-BK SL/BL

Connect with EatSmart

Glass Body Fat Scale Instructions for use

There are 4 user settings that store the memory of personal parameters for ease of continued use.

LIMITED TEN YEAR WARRANTY

BODY COMPOSITION SCALE

Don t overdo it! Weighing and weight maintenance

Don t overdo it! Weighing and weight maintenance

SBG 17. I Instruzioni per l uso Bilancia diagnostica in vetro. D Gebrauchsanleitung Glas-Diagnosewaage

DANA. DIAGNOSTIC SCALE Instruction for Use

LIMITED TEN YEAR WARRANTY

Body Composition Bathroom Scale # 0391 GETTING STARTED CONTACT US WARRANTY REVIEW. Buy This Product Our Story Shop SHOP NOW GET STARTED GREATER GOODS

Wireless Body Analysis Scale

SMART BATHROOM SCALES

QUANTUM. Body Composition Scale. 396lb x 0.2lb 180kg x 0.1kg

User's Manual. LEICKE Sharon Body Fat Analyser. Product number: LH67301

9117_IB.qxd:Layout 1 11/9/07 15:23 Page 1. please read this instruction manual before

Phone: (866) Website: greatergoods.com

Glass Analyser. please read this instruction manual before using the product for the first time

Body Fat Analyzer and Scale

Instruction Manual Body Fat Analyzer Scale

Compact Massager Instructions

USJ-875. Thank you for purchasing the USJ-875 SQUARE BIKE. Please read this manual carefully to ensure optimum performance and safety.

PilotOne II. User Guide

WEB CONNECT ANALYSIS Instruction Manual BMI

MANUAL. Model: BF-689. Instruction Manual Read this Instruction Manual carefully and keep it for future reference.

TBF-611BODYFAT MONITOR/SCALE. Instruction Manual Read this Instruction Manual carefully and keep it for future reference.

Operating Instructions

Allergy Reliever. User Manual. AR 1 Series

Instructions for Use REMOTE CONTROL RC-N

seca 808 D GB F I E DK S N FIN NL P GR PL Precision for health

PROFESSIONAL CARE OXYJET air. powered. Downloaded from manuals search engine. filter. OxyJet

D15525 D15513 D15513T D15511

Instruction Manual. Body Composition Monitor. Model HBF-358-BW. Thank you for purchasing OMRON Body Composition Monitor.

Pivotal Living Bluetooth Smart Scale. User Manual

CONTENTS. 2. What is the mywellness key?... 3

MANUAL. Model: BC-G02. Instruction Manual Read this Instruction Manual carefully and keep it for future reference.

Flex-Point HEATED MUSCLE MASSAGER

Smart Scale User Manual

Chair Massager With Heat Instructions

Phonak PilotOne II. User Guide

HRM Triax 15 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.

WHOLE BODY VIBRATION THERAPY

Body Analyser Scale with USB PC Data Tracking Instruction Manual and Guarantee

CIRCULATORY MASSAGER OPERA TING INSTRUCTION HM01-08QI

ENGLISH. USER MANUAL Register your product at: multi-action toothbrush

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

RC-S. Remote Control INSTRUCTIONS FOR USE

Electro Acupuncture PBG PBG-866-IG-E 2-4/00hk PK-IB-PIL

RENPHO Bluetooth Scale. Instruction Manual RP-520BT (LED)

Electric Desk Adjustable

Active Sport Massager WITH 3 INTERCHANGEABLE MASSAGE NODES

CONTENTS GETTING STARTED... 4 CHEST TRANSMITTER... 6 OPERATING INSTRUCTIONS TROUBLESHOOTING SPECIFICATIONS WARRANTY...

Instruction Manual. Models: T THE SCALE THAT MEASURES BOTH WEIGHT AND BODY FAT %

D X D D

HRM Triax 100 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.

NovoPen Echo User guide

Dear HighQ Check System Owner :

Instruction Manual Bluetooth Body Composition Monitor. Model HBF-206IT

Owner's Manual. Arm-type Fully Automatic Digital Blood Pressure Monitor. Arm Type. Model BSP-11

TBF-521BODYFAT MONITOR/SCALE. Instruction Manual Read this Instruction Manual carefully and keep it for future reference.

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ffi 10: ,#%, r*,&b{:**; rr-jn "*f

Dr. Mary Staggs DETOX. Detox footbath. The revolutionary way to re-balance your body WELLNESS.

Instructions for use of Weight Watchers bathroom scale

Pain Relief Patch. Operation Manual Read Before Using MODEL # ET

Cushion Massager with heat

Body Analyser Scale with USB PC Data Tracking Instruction Manual and Guarantee

Pretend & Discover Doctor s Kit TM

Remote control 2 guide

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.

For more information visit or contact hearx:

!"#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33

Deep Kneading Shiatsu Massager EXTRA-POWERFUL SHIATSU RELIEF

Soft Plus Fabric. Pocket for removable massager. Removable Massager: Uses 2 AAA batteries (not included)

ProPocket TM. User Guide

Mini Pulse Electronic Stimulator

Energy Fitness Tracker. User Manual EFT 1

PASSIVE BREATH ALCOHOL TESTER

Joint Relaxation Heated Vibration Massager. Knee and Joint Physiotherapy Unit

The Biomet EBI Bone Healing System. Patient Manual

AUTOMATIC WRIST Blood PReSSuRe MonIToR InSTRucTIon Manual

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

User Manual.

Reader and Sensor Demo Kit. Quick Start Guide

Gewässer Umwelt Schutz

Cordless 7-in-1 Super Massager WITH INTERCHANGEABLE NODES FOR 7 MAGNIFICENT MASSAGE TECHNIQUES

MA 25 Operating Manual

Low Row. User manual E S S E N T I A L S T R E N G T H

Nokia Body+ Weight & Body Composition - Daily Report. Installation and Operating Instructions EN - 1. Nokia Body+ v3.0 August 2017

Transcription:

tide germany Model Barbara / BA 914 Instruction Manual This document is hosted by Old Will Knott Scales www.oldwillknottscales.com ~.- BODY FAT ['..) BOOVWATER 1. ~ 2. 3. 4. MUSCLE MASS 5. (2J 6. 7. 8. 80NEMASS 9. Directory How does the body analyser work? Page 2 Conditions to use. Page 2 Commissioning Page 3 Programming / enter of personal data Page 4 Weighing function (weight measurement only) Page 4 Body Analysis. Page 5 Error Messages..... Page 6 Technical Data...Page 7 Warranty Page 7

Thank you for your decision to purchase this high-quality body analyser scale. Please peruse read this instruction manual prior to first start up and keep this user instruction careful to have this information on hand whenever it is needed. 1. How does the body analyser work? Through this new revolutionary scale, you will be able to get information about your body composition with reference to your weight. body fat %, body water %, muscle mass % and bone mass kg. Rrst of all, you have to enter once your personal data like gender (male or fennale), age and body height under your selected personal memory location. Afterwards a measurement is as simple as on a normal bath'oom scale. Afterwards a measurennent is as simple as on a normal bathroom scale. You have only to select your personal memory location, step on the scale and within a few seconds, your measured values will be indicated. The analysis based on the measurement of the body's electrical resistance. A low, safe electrical signal passes freely through fluids contained in lean tissue, such as muscle and blood, but meets resistance passing through fat tissue. The body analyser accurately measures the resistance and with reference to your personal data use it to calculate elennents of body composrtion. 2. Conditions to use If possible, the measurement should be done undressed and amiays barefoot. By nature, a body is subject of fluctuations (for exarnpkl loss of water after taking exercise or after a sauna visit, after a meal, etc.). To enable comparable readings rt is important to take the measurements as possible always under the same conditions. In order to ensure that the results of analysis are accurate and consistent, please keep the measurement conditions constant always at the same daytime. In the morning, directly after you've woken up, your body will be dehydrated and also the majority of fluid will be stored in the central trunk area. This means that the resistance is relatively high because of the poor conductivity in the body. By intensify moving during the day progresses the fluid becomes more evenly distributed through the limbs and increasing the accuracy of the readings. To get a realistic result it is important to take your readings at the same time and under the same conditions every day. The easiest way to stick the rule, measure amiays in the morning, 15 minutes after you've got up, either before or after you've gone to the bathroom. In spite of a very low electrical signal, this body analyzer is not suitable for persons with heart pacemaker or other electronic medical implants! There is no risk for persons with none electronic implant for instance a titanium plate in the knee. However, metal conducts the electric current extrennely well and therefore the scale implicates the body fat value "beautified" - means the actual body fat value is higher as Indicated. However, tendencies may be determined as well. 2

Due to menstrual cycle and hormonal changes women experience greater changes in their hydration level. Retaining fluid may cause the weight to fluctuate day-to-day. This will also affect the body fat percentage readings. If the hydration level is high, the body fat percentage is slightly less - a less hydration level means the body fat percentage is slightly higher. There is no hea~hy risk for pregnancy. The body analyzer is absolutely safe for the mother and her unbom baby. However, due to the changes in water content in the mother's body, the readings should not be interpreted as completely accurate. ADE Germany takes no responsibility for any damages or losses caused by the use of this body analyzer scale or for Third party claims. This product is exclusively intencled for private use. This product is not designed for commercial or professional use in hospitals or other medk:al facilities. 3. Commissioning Safety guidelines: The appliance is not intended for use by persons Oncluding children) with reduced physk:al, sensory, or mental capabilities, or lack of experience and knowledge, unless a person responsible for their safety has given them supervision or instruction concerning use of the appliance. Children should be supervised to ensure that they do not play with the appliance. Not suitable for persons with electronic implants (heart pacemaker, etc.). Place the scale on a plane and firm surface (tiles, hardwood flooring, etc.) to avoid a wrong measurement on carpeted floor Attention - Hazard of slipsl Do not stand on the scale with wet feet or on a slippery surface of the weighing platform. Please care that no heavy object may fall on the scale. The glass surface is breakable. Preparation: Clean the scale only by using a slightly damp cloth. Do not use solvents or abrasive cleaning agents. Do not submerge the scale under water. Open the battery cover at the bottom side of the scale and remove the battery safety strip. Please ensure the correct polarity of the battery (+/-). 3

There is a little push button right beside the battery case at the bottom side of the scale for country specific settings with the optkln to switch from kg = kilogram to Ib = pound or to st:lb = stone: pound. Please pay attention to use the scale under consk:leration of your country specific unit of weight. 4. Programming / Enter of personal data Before first time use your personal data like gencler (female or male), age and body height must be programmed and saved under selected locations PO - P9 (up to 10 persons). The scale is equipped with highly sensitive touch buttons. The touch buttons are located below the display. To enter your personal data please utilise the buttons: SET (on and save button), T (Plus button),... (minus button) and folaw the particular points: 1. Ughtly touch the SET-button. The display indicates flashing "PO". To select your personal locatkln (PO - P9), touch the... - or..-button. After the selection of your personal location, touch the SET-button to save the reading. 2. After you've selected your personal location (e.g. P3), the symbol for gencler starts to flash. To select the requested gender (Y male oni female), touch the... - or..-button. After the selection of your gencler, touch the SET-button to save the reading. 3. After you've selected your gencler (e.g. female), the symbol for age starts to flash (default age 30). To enter your age, touch the... - or..-button. After the selection of your age, touch the SET-button to save the reading. 4. After you've selected your age, the symbol for body height starts to flash (defau~ 170 em). To enter your body he9ht, touch the... - or..-button. After the selection of your body height, touch the SET-button to save the reading. The scale indicates once again your selected personal data. That settles the completion of input and the scale returns to the indication "0.0 kg". The scale is ready to use and you may now start your body analysis. Without further activ~ the scale automaticaily power-off. Your personal data are stored. If you push the... - or..-button within 2 seconds after the first complete input, you can directly enter the personal data of a further person. Altematively, you repeat the complete steps listed below for further entries of personal data. 5. Weighing function (weight measurement only) 1. Switch-on the scale by using the tap-on-function. For this, tap with your foot short and firm on the scale. The display indicates all symbols and a few seconds later "0.0 kg". Now the scale is ready to use. 4

2. Step on the scale. Remain stationary on the weighing platform and do not hold you tight. 3. After the scale levelled-off your w"ght wili be indicated successively three times and then for 10 seconds steady. Afterwards the scale switch-off automatically. 6. Body Analysis An analysis is only possible in bare feet. Your personal data must be entered first (please see page 4). 1. Switch-on the scale by touching the SET-button. Please select your personal memory location (where your personal data area stored) by using the... - or... -button. Your personal data (location, gender, age, and body height) wili be successively displayed. Confirm these each at a time by touching the SET-button. Afterwards "0.0 kg" will be indicating. 2. Now, carefully step in bare feet on the four stainless steel electrodes (measuring units) of the scale and remain stationary. 3. At first, your w"ght will be indicated on the display. Then, while the analysis is taking place, the indication flashes. After completion of the measurement, your measured values will be shown twice in a row as foliows: Your weight in kg - your body fat in %. your body water in %, your muscle mass in % and your bone mass in kg. After a few seconds the scale switch-off automatically. The bociy fat content is shown as the amount of stored fat as a percentage of total body weight. There is no generally accepted set value as this varies significantly according to gender (due to the different build) and age. Body fat is vital for basic body functions. It's protecting organs, cushioning joints, regulating body temperature, storing vitamins and serves the bociy as energy storage. As essential for women a minimum body fat proportion between 10% and 13% and for men between 10% and 13% is requested with the exception of competitive athletes. Body fat is not a clear indicator for health. Too high body weight and a too high bociy fat proportion are linked to the incidence of many civilization diseases such as dialbetes, cardiovascular diseases, etc. Lack of movement and improper nutrrtion are often the prime course for these diseases. There is an obvious direct relationship between overweight and lack of movement. 5

A significant part of the human body consists of body water. This body water is differently distributed throughout the whole body. Lean muscle tissue contains approx. 75% body water, blood approx. 83% body water, body fat approx. 25% body water and bones have a water content of about 22%. The average total body water percentage range for healthy men is between 50-65%. The equivalent value for women is approximately 45-60% due to the higher body fat content. About two third of the total body water is stored in the ceils and is therefore called intra ceiluar. The other third of the total body water is extra cellular body water. Women * AGE Body Fat I BodvWater sli9htly slim rormal overweiaht overwei"'ht rormal 10-16 <18% 18-28% 29-35% >35% 57-67% 17-39 <20% 20-32% 33-38% >38% 47-57% 40-55 <23% 23-35% 38-41% >41% 42-52% 56-85 <24% 24-38% 37-42% >42% 37-47% Men Y AGE Body Fat BOdVWater slightly slim rormal overweiaht overwpinht rormal 10-16 <10% 10-18% 19-23% >23% 58-72% 17-39 <12% 12-20% 21-25% >25% 53-67% 40-55 <13% 13-21% 22-26% >26% 47-61 % 56-85 <14% 14-22% 23-27% >27% 42-56% There are no validated standards for muscle mass.. 7. Error Messages Overioad - The weight exceeds the maximum capacity of 150 kg. Please immediately remove the critical load to avoid load ceil damage. Batteries are used up - Please repace the batteries with the ntended type (2 x CR2032). 6

8. Technical Data Capacity x graduation: Display resolution: Display resolution: Display resolution: Display resolution: Personal memory loc.: Age: Body height: Dimensions: Batteries: max. 150 kg x 100 g body fat: 0.1 % body water: 0.1 % muscle mass: 0.1% bone mass: 100 g 10 positions 10-80 years 100-240 em approx. 300 mm x 300 mm x 34 mm 2 x CR2032 (induded) Subject to technica modifications 9. Warranty ADE warrants for a period of 3 years from the date of purchase that it will remedy any defects due to faulty material or workmanship free of charge by repair or replacement. When purchasing, please have the warranty coupon signee and stamped by the dlealer. When making a guarantee claim, please retum the weighing scale together with the guarantee card including the reason of complaint to your dealer. CE CE-Conformity - This device features radio interference suppression in compliance with valid EC Regulation 2004/108 Note: The displayed valce may be adversely affected under extreme electromagnetic influences, e.g. when using a radio unil in the immediate vicinity of the device. Once the interference has been rectifled, the product can once again be used for its intendled purpose. The device may have to be switched-on again. Statutory instructions on battery disposal Batteries must not be disposed as household waste. The law requires that you, as consumer, retum the waste batteries either to public collection points in your town or village or to any outlet selling batteries of the same kind. Note: CR (U); AA (AI, Mn); AAA (AI, Mn) Batteries are marked as follows: U Battery contains Uthium AI Battery contains Alkali Mn Battery contains Manganese 7

Safety instructions for lithium batteries (CR20321CR2430): 1. Uthium batteries are lithium manganese cells. If you do not use the scale over a longer period, you should take out the batteries ot the device. 2. Never open the lithium battery, do not put into fire, or expose to shocks because an explosion risk lasts or discharge of poisonous exposure to fumes might possible. 3. Never touch leaked cells with bare hands. 4. When eyes or hands are contaminated, it is essential to rinse with lots of water. You should go to a doctor if skin or eyes are irritated. 5. Dispose cells on~ complete~ discharged or protected against polarity reversal wrapped according to your local disposal regulation. 6. Do not expose the cells to direct solar radiation and store away from heat: otherwise, there is risk of overheating. 7. Maintain a storage temperature of < 40 C. Disposal of old electrical and electronic equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead It shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. For more detailed information about recycling contact your local city office, your household waste disposal service or the shop where you purchased the product. With kind regards ADE (GmbH & Co.) X ---------------------------------------------------------------------------------------------------- Guarantee Card - 3 years warranty for the Body Analysing Scale Sender Reason for complaint Date of purchase Please return this guarantee card together with the receipt to your retailer.