CLINICAL PAPER / ORTHOPEDIC

Similar documents
Navigation for total hip arthroplasty

HIP SOFTWARE-GUIDED SURGERY

Optimum implant geometry

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6

9800 Metric Blvd. Austin, Texas

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY

Preoperative Planning. The primary objectives of preoperative planning are to:

Bone Preservation Stem

PLR. Proximal Loading Revision Hip System

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

HipNav: Pre-operative Planning and Intra-operative Navigational Guidance for Acetabular Implant Placement in Total Hip Replacement Surgery

HIP SYSTEM SURGICAL TECHNIQUE

MEDICAL POLICY SUBJECT: COMPUTER ASSISTED NAVIGATION FOR KNEE AND HIP ARTHROPLASTY

A Useful Reference Guide for the Stem Anteversion During Total Hip Arthroplasty in the Dysplastic Femur

Bi-Polar 22.2mm & 28mm System - Operative technique

Prevention of dislocation after hip replacement in elderly patients. Piotr WOJCIECHOWSKI, Damian KUSZ, Mariusz NOWAK, Konrad KOPEĆ

Bone Bangalore

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

AML Hip System. Design Rationale/ Surgical Technique

Transverse Acetabular Ligament A Guide Toacetabular Component Anteversion

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

Leg-length Inequalities Following THA Based on Surgical Technique

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Research Article Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty

Cover Page. The handle holds various files of this Leiden University dissertation.

Continuing the Tradition. VerSys Heritage Hip System

Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty

Aesculap Trilliance Triple Tapered Polished Hip Stem

Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Digital Templating of the Non-Affected Hip as a Means of Minimizing Leg-Length Discrepancy after Primary Total Hip Arthroplasty

Approach Patients with Confidence

Biomechanical outcome after computerassisted

DIRECT SUPERIOR HIP APPROACH IN TOTAL HIP ARTHROPLASTY. Anil Thomas, MD Adult Reconstruction Peachtree Orthopedics Atlanta, GA

Scan Bi-Polar 22/28. Operative Technique

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Increased Rate Of Dislocation Of Total Hip Arthroplasty With Cementless Implants: Accuracy Of Acetabular Inclination.

DISLOCATION OF THE TOTAL HIP Arthroplasty

LEG LENGHTH DISCREPANCY, DISLOCATION RATE AND OFF-SET IN TOTAL HIP REPLACEMENT USING A SHORT MODULAR STEM: NAVIGATION VERSUS CONVENTIONAL FREE-HAND

Acetabular Center Axis: Is It the Future of Hip Navigation?

A radiographic comparison of femoral offset after cemented and cementless total hip arthroplasty

Bone Conserving Hip Replacement Surgical technique

R/F. Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? 1. Abstract

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Approach Patients with Confidence

S U R G I C A L T E C H N I Q U E

Predicting the Position of the Femoral Head Center

Surgical Technique r5.indd 1 12/8/10 10:36 AM

New technique: practical procedure of robotic arm-assisted (MAKO) total hip arthroplasty

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability

Functional safe zone. Safe zone

Failure to correct femoral anteversion on the AP Pelvis radiograph leads to errors in prosthesis selection in total hip arthroplasty

Optimum implant geometry

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

Cup Alignment Error Model for Total Hip Arthroplasty

Surgical Technique. Hip System

Design Rationale. ECHELON Primary Hip System

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

Fixed and Variable Geometry Total Shoulder Arthroplasty

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

Leg Length Discrepancy after Total Hip Arthroplasty Using the Modified Anterolateral Approach for Stable Hip

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Leg length discrepancy After Total Hip Replacement: Prevalence And impact on functional outcome

DIRECT ANTERIOR APPROACH

RECOVERY. P r o t r u s i o

Hip Resurfacing.

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Optimum implant geometry

Operating Instruction. Müller Hip Stem

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Biomechanical concepts of total shoulder replacement. «Shoulder Course» Day 1. Richard W. Nyffeler Orthopädie Sonnenhof Bern. 11. Sept.

Ovation Hip System. Surgical Technique

PRODUCT RATIONALE & SURGICAL TECHNIQUE

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Clinical Evaluation Surgical Technique

Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty

21st Century Fracture Management ETS. Surgical Protocol

Robotic-arm-assisted Arthroplasty Advances Surgical Precision NEWYORK-PRESBYTERIAN QUEENS. Long Island

VerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique

What to expect from your NAVIO Robotics-assisted Partial Knee Replacement

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

TOTAL HIP REPLACEMENT:

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

APS Natural-Hip System

Approach Patients with CONFIDENCE

EMPERION Modular Hip System Surgical Technique

Manza Cup HA SURGICAL TECHNIQUE.

Absolut TM Cemented Stem. Surgical Technique

Robotic-Arm Assisted Surgery

Corporate Medical Policy

A further enhanced classic. Wagner SL Revision Hip Stem

Total Hip Replacement in Diaphyseal Aclasis: A Case Report

Integral 180 Surgical Technique

Computed Tomography-based Surgical Navigation for Hip Arthroplasty

Clinical Study Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Computer-Assisted Rotational Acetabular Osteotomy for Patients with Acetabular Dysplasia

Transcription:

HIP LEG LENGTH AND OFFSET Kelley T.C. and Swank M.L. (2009) Using CAS leads to more accurate positioning within the safe zone (inclination between 30 and 50, anteversion between 5 and 25 ) CAS improves acetabular component position and can enable minimal invasive hip surgery Navigated THA may become standard of care Navigation helps quantifying changes in leg length Manzotti A. et al. (2009) Limb length restoration significantly better in THR with computer navigation. Computer navigation represents practical way to achieve a more anatomical hip arthroplasty Murphy S.B. and Ecker T.M. (2007) The Brainlab navigational measurement algorithm to determine the leg length is efficient, reliable and reproducible. Additional benefits like accelerated recovery and less invasiveness are reached with a reliable computer-assisted leg length measurement. Renkawitz T. et al. (2010) With pinless navigation reliable leg length and offset measurements are reached. Pinless navigation avoids the pin-related risks like fracture, infection or pin loosening. Lecerf G. et al. (2009) Femoral offset restoration is essential for function, joint stability and implant longevity. Navigation systems permit proper restorations of limb length and improve femoral offset restoration, as well.

ABSTRACT Role of Navigation in Total Hip Arthroplasty J Bone Joint Surg Am. 2009 Feb; 91 Suppl 1:153-8 Kelley T.C. and Swank M.L. Current uses of computed tomography-based and imageless navigation systems for total hip arthroplasty include proper placement of the acetabular component, measurement of limblength changes, enablement of minimally invasive surgery, and proper placement of components for hip resurfacing procedures. This article provides an overview of the rationale for computerassisted surgery in total hip arthroplasty and hip resurfacing. The experience of the senior author (M.L.S.) with computerassisted surgery for hip arthroplasty has demonstrated improved position of the acetabular component as compared with the position attainable with use of mechanical instruments, maintenance of appropriate position of the acetabular component during minimally invasive surgery, and appropriate positioning of the femoral and acetabular components during the learning curve for hip resurfacing procedures. SUMMARY The authors highlight key aspects in total hip arthroplasty (THA) like cup positioning and leg length measurement. Proper cup positioning,according to this paper, not only prevents impingement and dislocation but also pelvic osteolysis, acetabular migration and implant wear. Mechanical alignment guides show clear limitations in accurate and precise positioning of implants whereas CAS, after a learning curve, provides for decreased variability with regard to orientation of the acetabular component and increased accuracy. CONCLUSION Using CAS leads to more accurate positioning within the safe zone (inclination between 30 and 50, anteversion between 5 and 25 ) ( ) recent literature has demonstrated that the percentage of cetabular components being placed in the target safe zone was higher in computer-navigated hips than in nonnavigated controls, with less variation in implant position. CAS improves acetabular component position and can enable minimal invasive hip surgery Computer-assisted surgery has contributed to reproducible and accurate positioning of hip arthroplasty implants.computer navigation for minimally invasive approaches as well as hip resurfacing continues to evolve.

(continued ) Navigated THA may become standard of care Taking into account the economic considerations of long-term implant survivorship, computer-assisted total hip arthroplasty may become the standard of care. Navigation helps quantifying changes in leg length Postoperative limb-length inequality remains a major cause of patient dissatisfaction and litigation after hip replacement. Navigation has shown potential to help quantify intraoperative limb length and potentially reduce the risk for postoperative limb-length inequality. Additionally Renkawitz et al. recently found femoral pinless leg length and offset measures reliable in conjunction with an imageless navigation technique of realignment during THA performing a study on 18 cadaveric hips

ABSTRACT Does computer-assisted surgery benefit leg length restoration in THR? Navigation versus conventional freehand Int Orthop 2011 Jan;35(1):19-24. Manzotti A. et al. The clinical outcome was evaluated using both the Harris Hip Score and the normalised Western Ontario and McMaster Universities (WOMAC) Arthritis Index. Restoration of limb length was significantly better in the computer-assisted THR group. The number of patients with a residual limb length discrepancy greater than 10 mm and/or a post-operative over-lengthening was significantly lower. No significant difference in the Harris Hip Score or normalised WOMAC Arthritis Index was seen between the two groups. The surgical time was significantly longer in the computerassisted THR group. No post-operative dislocations were seen. Leg length discrepancy following total hip replacement (THR) can contribute to poor hip function. Abnormal gait, pain, neurological disturbance and patient dissatisfaction have all been described as a result of leg length inequality after THR. The purpose of this study was to determine whether the use of computer navigation in THR can improve limb length restoration and early clinical outcomes. We performed a matched-pair study comparing 48 computer-assisted THR with 48 THRs performed using a traditional freehand alignment method. The same implant with a straight non-modular femoral stem was used in all cases. The navigation system used allowed the surgeon to monitor both acetabular cup placement and all the phases of femoral stem implantation including rasping. Patients were matched for age, sex, arthritis level, pre-operative diagnosis and pre-operative leg length discrepancy. At a minimum follow-up of six months, limb length discrepancy was measured using digital radiographs and a standardised protocol. The number of patients with a residual discrepancy of 10 mm or more and/or a post-operative over-lengthening were measured. SUMMARY Matched pair study with a comparison of 48 computer-assisted THA (used Brainlab navigation) with 48 free-hand alignment THA surgeries. The limb length was determined pre-operatively and 6 months post-operatively. The clinical outcome was evaluated using two different scores and revealed better outcome for navigated hips, whereas not significant.

CONCLUSION Limb length restoration significantly better in THR with computer navigation. [ ] our results demonstrated that in THR computer navigation significantly improves the restoration of limb length. In the computer-assisted group, the mean post-operative leg length discrepancy was reduced to 5.06 mm (range: 0 12) compared to 7.64 mm (range: 0 20) in the freehand group. Computer navigation represents practical way to achieve a more anatomical hip arthroplasty We believe that computer navigation of both the femoral stem and acetabular cup in THR represents a practical way to achieve a more anatomical hip arthroplasty.

ABSTRACT Femoral offset: Anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty Orthop Traumatol Surg Res. 2009 May;95(3):210-9 Lecerf G. et al. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset mea surement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modularfemoral neck This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 ) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Conclusion. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. SUMMARY In this collection of independent anatomic,radiological and clinical works the implications of femoral offset for THA and preoperative templating are assessed. The authors compile how to measure femoral offset and show the impact and methods of restoring the femoral offset in THA.

CONCLUSION Femoral offset restoration is essential for function, joint stability and implant longevity. [ ] femoral offset restoration is essential to improve function and longevity of hip arthroplasty Femoral offset restoration is recognized as an important part of THA procedure to improve joint stability and implant longevity. Navigation systems permit proper restorations of limb length and improve femoral offset restoration, as well. [...] the use of a navigational system allows proper restoration of limb length in all patients, by intraoperatively informing the surgeon of the changes to bring to reach the planned objectives. It also improves both offset and length which restoration is only limited by intraoperative selection of the available prostheses.

ABSTRACT Evaluation of a New Leg Length Measurement Algorithm in Hip Arthroplasty. Clin Orthop Relat Res. 2007 Oct;463:85-9 Murphy S.B. and Ecker T.M. Leg length inequality after hip arthroplasty is a major source of patient dissatisfaction and dysfunction. Despite numerous reported methods to intraoperatively determine leg length change, it remains a challenge. We developed a reliable and reproducible method to measure leg length change using surgical navigation. The method measures the change in position of the femur relative to the pelvis and the pelvic coordinate system without the need to establish a femoral coordinate system. We replaced 112 hips using the new leg length measurement algorithm. Leg length change measured at surgery was compared with leg length change as measured on magnification-corrected pre- and postoperative radiographs. Compared with radiographically measured leg length change, the leg length changes measured intraoperatively had a mean difference of 0.5 ± 1.77 mm (range, 5 3.9 mm). We found no difference between radiographic data and navigation data. Leg length change measured using surgical navigation, measuring the change in position of the femur relative to the pelvic coordinate system, without establishing a femoral coordinate system is easy and reliable. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. SUMMARY Within a therapeutic study including 107 patients the leg length change was measured in 112 THA surgeries using a CT-based hip navigation system (Brainlab hip CT) with a newly developed measurement algorithm. Comparing these results with the radiographically measured leg length change revealed no differences. The authors conclude that the navigational measurements are reliable and reproducible. CONCLUSION The Brainlab navigational measurement algorithm to determine the leg length is efficient, reliable and reproducible. Our data demonstrate this method of measuring leg length change during surgery is efficient, reliable and reproducible. Additional benefits like accelerated recovery and less invasiveness are reached with a reliable computer-assisted leg length measurement. Thus, reliable computer-assisted methods of measuring leg length may be even more important to allow the benefits of accelerated recovery with tissue-preserving, less invasive arthroplasty techniques without creating larger difficulties with management of leg length change.

ABSTRACT Leg Length and Offset Measures with a Pinless Femoral Reference Array during THA. Clin Orthop Relat Res. 2010 Jul; 468(7):1862-8 Renkawitz T. et al. SUMMARY In this case study including 10 specimens it was analyzed if the intraoperative leg length and offset changes could be measured accurately using a pinless and imageless CAS procedure (Brainlab navigation used). The results of 17 THA surgeries were compared to an analysis of pre- and postoperative CT scans made by two examiners. The authors report a high correlation of the leg length and offset measurement methods. The bony fixation of reference marker arrays used for computerassisted navigation during total hip arthroplasty (THA) theoretically involves the risk of fracture, infection, and/or pin loosening. We asked whether intraoperative assessment of leg length (LL) and offset (OS) changes would be accurate using a novel pinless femoral reference system in conjunction with an imageless measurement algorithm based on specific realignment of the relationship between a dynamic femoral and pelvis reference array. LL/OS measurements were recorded during THA in 17 cadaver specimen hips. Preoperatively and postoperatively, specimens were scanned using CT. Linear radiographic LL/OS changes were determined by two investigators using visible fiducial landmarks and image processing software. We found a high correlation of repeated measurements within and between (both 0.95 o greater) the two examiners who did the CT assessments. Pinless LL/OS values showed mean differences less than 1 mm and correlations when compared with CT measurements. CONCLUSION With pinless navigation reliable leg length and offset measurements are reached. We found a high correlation of repeated measurements within and between [ ] the two examiners who did the CT assessments. Pinless LL/OS values showed mean differences less than 1 mm and correlations when compared with CT measurements. We found femoral pinless LL and OS measures reliable in conjunction with an imageless navigation technique of realignment during THA in an experimental cadaver study.

(continued ) Pinless navigation avoids the pin-related risks like fracture, infection or pin loosening. [ ] bony fixation of reference marker arrays used for navigation theoretically involves the risk of fracture, infection, and/or pin loosening Application of noninvasive, femoral pinless reference systems could further reduce the risks of systems depending on pins while minimizing the risk of LL discrepancies.