Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Similar documents
Reaching new heights. Comprehensive. Efficient. Simple.

Optimum implant geometry

Optimum implant geometry

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

The Leader in Orthopaedic Innovation

Hip Product Brochure

Bone Bangalore

Featuring. Technology. Product Rationale

Design Rationale. ECHELON Primary Hip System

ACETABULAR CUP SURGICAL TECHNIQUE

Bone Preservation Stem

Optimum implant geometry

Understanding Hip Implant Options

PLR. Proximal Loading Revision Hip System

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

The information contained in this document is intended for healthcare professionals only.

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

PINNACLE REVISION CUP SYSTEM

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Arcos Modular Femoral Revision System

ReCap Product Rationale

Product Portfolio. Consensus Knee Systems. Consensus Hip Systems

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Manza Cup HA SURGICAL TECHNIQUE.

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Optimizing function Maximizing survivorship Accelerating recovery

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Dual Mobility System Surgical technique

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Comprehensive. Simple. Efficient.

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

*smith&nephew POLARCUP Dual Mobility System. Product Information

Continuing the Tradition. VerSys Heritage Hip System

Dual Mobility System Evaluation surgical technique

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

CONSENSUS ORTHOPEDICS INC.

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement

9800 Metric Blvd. Austin, Texas

PROFEMUR Total Hip System P R O D U C T C A T A L O G

Specifications guide ECHELON. Hip System

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Revision. Hip Stem. Surgical Protocol

The information contained in this document is intended for healthcare professionals only.

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

ZMR Crossover Instruments. Abbreviated Surgical Technique

Progeny Hip Stem. Surgical Protocol and Product Specifications

Avenir Femoral Hip System

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

MicroSeal Total Hip Acetabular System. Like Nothing Else

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

MetaFix Cementless Total Hip Replacement Product overview

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

One system for all revision types

Allofit /Allofit -S Alloclassic Acetabular Cup System

TOTAL HIP REPLACEMENT:

What Are Hip and Knee Replacement Implants Made Of?

Surgical Technique. Cup System

Zimmer Segmental System

RECLAIM REVISION HIP SYSTEM

Surgical Technique. Hip System

Bi-Polar 22.2mm & 28mm System - Operative technique

Stability without compromise. Epsilon Durasul Constrained Insert

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Active Articulation E1

Scan Bi-Polar 22/28. Operative Technique

FLH /11

Answer. Hip System Design Features:

Approach Patients with Confidence

Approach Patients with CONFIDENCE

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue

LPS SYSTEM POCKET GUIDE

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

AML Hip System. Design Rationale/ Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Product Rationale. Where Strength and Modularity Connect

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

Exeter. Technical Guide

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

MULTIPOLAR BIPOLAR CUP. Surgical Technique

Trabecular Metal Acetabular Restrictor and Augment

RECOVERY. P r o t r u s i o

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

28 Surgical Technique

Approach Patients with Confidence

Trabecular Metal Acetabular Restrictor and Augment

CPCS. Training Manual. Collarless Polished Cemented Stem

Surgical technique MkII instrumentation

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

HIP SYSTEM SURGICAL TECHNIQUE

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Transcription:

Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished Tapered Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-CL3 STEM-CL4 STEM-CL5 STEM-CL6 STEM-CL7 STEM-CL8 STEM-CL9 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm 132 Cement Collared Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-CC3 STEM-CC4 STEM-CC5 STEM-CC6 STEM-CC7 STEM-CC8 STEM-CC9 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm 132 Metal Femoral Head Outer Diameter Description MH-221214S 22 mm short neck -3.5 MH-221214M 22 mm medium neck 0 MH-221214L 22 mm long neck +3.5 MH-281214S 28 mm short neck -3.5 MH-281214M 28 mm medium neck 0 MH-281214L 28 mm long neck +3.5 Ceramic Femoral Head Outer Diameter Description CH-281214S 28 mm short neck -3.5 CH-281214M 28 mm medium neck 0 CH-281214L 28 mm long neck +3.5 CH-321214S 32 mm short neck -4 CH-321214M 32 mm medium neck 0 CH-321214L 32 mm long neck +4 Cancellous Bone Screw Length S-15 15 mm S-20 20 mm S-25 25 mm S-30 30 mm S-35 35 mm S-40 40 mm S-45 45 mm S-50 50 mm S-55 55 mm S-60 60 mm Acetabular Cup UHMW Polyethylene insert Outer Diameter Outer Diameter Acetabular Cups Ceramic insert Outer Diameter Outer Diameter AC-42 42 mm AC-54 54 mm AC-CL-44 44 mm AC-CL-56 56 mm AC-44 44 mm AC-56 56 mm AC-CL-46 46 mm AC-CL-58 58 mm AC-46 46 mm AC-58 58 mm AC-CL-48 48 mm AC-CL-60 60 mm AC-48 48 mm AC-60 60 mm AC-CL-50 50 mm AC-CL-62 62 mm AC-50 50 mm AC-62 62 mm AC-CL-52 52 mm AC-52 52 mm AC-CL-54 54 mm UHMW Polyethylene liner / Flat type Use Acetabular Cup Inner ALF-22-4244 42 mm ~ 44 mm 22 mm ALF-22-4648 46 mm ~ 48 mm 22 mm ALF-22-5052 50 mm ~ 52 mm 22 mm ALF-28-4244 42 mm ~ 44 mm 28 mm ALF-28-4648 46 mm ~ 48 mm 28 mm ALF-28-5052 50 mm ~ 52 mm 28 mm ALF-28-5456 54 mm ~ 56 mm 28 mm ALF-28-5860 58 mm ~ 60 mm 28 mm UHMW Polyethylene liner / 10 Elevated type Use Acetabular Cup Inner ALE-22-4244 42 mm ~ 44 mm 22 mm ALE-22-4648 46 mm ~ 48 mm 22 mm ALE-22-5052 50 mm ~ 52 mm 22 mm ALE-28-4244 42 mm ~ 44 mm 28 mm ALE-28-4648 46 mm ~ 48 mm 28 mm ALE-28-5052 50 mm ~ 52 mm 28 mm ALE-28-5456 54 mm ~ 56 mm 28 mm ALE-28-5860 58 mm ~ 60 mm 28 mm Ceramic liner Use Acetabular Cup Inner CL-28/37G 44 mm ~ 50 mm 28 mm CL-32/41G 52 mm ~ 56 mm 32 mm CL-32/44G 58 mm ~ 62 mm 32 mm Bipolar Cup Outer Diameter Outer Diameter BC-42 42 mm BC-49 49 mm BC-43 43 mm BC-50 50 mm BC-44 44 mm BC-51 51 mm BC-45 45 mm BC-52 52 mm BC-46 46 mm BC-53 53 mm BC-47 47 mm BC-54 54 mm BC-48 48 mm BC-55 55 mm Bipolar liner BL-2237 BL-2239 / BL-2839 BL-2241 / BL-2841 BL-2243 / BL-2843 BL-2245 / BL-2845 BL-2847 BL-2849 Use Bipolar Cup 42 mm 43 mm ~ 44 mm 45 mm ~ 46 mm 47 mm ~ 48 mm 49 mm ~ 50 mm 51 mm ~ 52 mm 53 mm ~ 54 mm Inner 22 mm 22 mm / 28 mm 28 mm Factory : 2-Ba #514 Shihwa Industrial Complex, Jeongwang-dong, Siheung-si, Gyeonggi-do, Korea Tel : +82 31 319 0406~7 Fax : +82 31 319 0414 Seoul Office : #501 STX V-Tower, 371-37 Gasan-dong, Geumcheon-gu, Seoul, Korea Tel : +82 2 811 3571 Fax : +82 2 811 3572

Design Philosophy MultiFit TM Total Hip System The dramatic success of total hip arthroplasty over the 30 years means that total hip replacement became common popular operation easily approacheable to average orthopaedic surgeons. Every years approximately one million of patients are expected to perform total hip replacement throughout the world. The design features of MultiFit TM Total Hip System has its foundation in critical anatomical assessment, clinico-surgical experience and optimizing bioengineering research and development for a recent 10 years. Cementless Tapered Stem Cement Polished Tapered Stem Cement Collared Stem Acetabular System Bipolar System

Cementless Tapered Stem The overall design conception was line to line figure. Due to porous and plasma coated area having 0.5~0.8mm thickness and overall taper stem configuration, the compression stress and hoop stress are efficiently increased during press fit maneuver which results in added stability and fixability with the host bone. The noncemented stem is composed of Ti-6A1-4V ELI biomaterial with sound biomechanically designed neck shaft angle fomulating 132 degrees. It is also design to have anatomical medial curve within the neck. Porous coated The connecting taper to ball head has clinically proven 12/14 taper. This enables both metal taper and ceramic head to fit with more stable configuration. The stem dur to its cross section of the neck geometry being optimized track formation achieves maximum range of motion. Plasma spray The proximal cross section was designed to have optimal rotational stability. Introduction A multiple clinical studies has been showing that titanium tapered stem result in less thigh pain and stress shielding. However, stiff stem that is figidly fixed in this distal one third inevitably lead to proximal stress shielding and thigh pain. The biomechanical concepts of the MultiFit TM cementless titanium stem is characterized by the proximal load transfer, which result in decreased stress shielding and less thigh pain and excellent rotational stability. The proximal portion was coated with porous surface area for sound bony ingrowth, whereas the distal portion is coated with sand-blasting making good bony ongrowth. The shapes of the distal part of stem is kept rectangular and relatively slender and distal tip of the stem has polished surface with bullet configuration reducing the friction with the cortex and leading more smooth and safe insertion of the stem. 2 3

Cement Polished Tapered Stem Tapered polished MultiFit TM cemented stem designed to decrease stress shielding of proximal femur and to increase rotational stability with comparative assessment by Finite Element Analysis. The cement stem is composed of Co-Cr alloy with sound biomechanically designed neck shaft angle formulating 132 degrees. It is also designed to have anatomical medial curve within the neck. The stem due to its cross section of the neck geometry being track formation achieves maximum range of motion. Introduction The cement collarless stem has overall highly polished surface that minimizes friction between the stem surface and cement. Also the triple taper, which is wedge shape, reduces shear stress while increasing the compress stress and tensile hoop stress. This provides reduction in stress shielding and subsidence and promote rotation stability with excellent self-locking taper. The low frictional charnley hip stem developed by Sir John charnley has set the gold standard for the cemented total hip arthroplasty. MultiFit TM polished tapered stem has been designed to build on this experience and comparative assessment of conventional cemented designs by detailed finite element analysis. With the MultiFit TM cementless tapered stem, OTIS biotech has offered this successful concepts of design variables and wide range of size, while incorporating additive design characteristics to further enhance clinical performance of implants. The MultiFit TM collared cemented stem has been designed to build on the sound design principle of Sir John charnley low-friction torque arthroplasty and extensive arthropometric studies. Finite Element Analysis

Cement Collared Stem The cement collared taper, which is wedge shape, reduces shear stress while increasing the compress stress and tensile hoop stress. This provides reduction in subsidence and promote rotation stability with excellent self-locking taper. The noncemented stem is composed of Ti-6A1-4V ELI biomaterial with sound biomechanically designed neck shaft angle fomulating 132 degrees. It is also design to have anatomical medial curve within the neck. The connecting taper to ball head has clinically proven 12/14 taper. This enables both metal taper and ceramic head to fit with more stable configuration. Proximal textured surface increase strength of cement-stem interface Grit blasted satin surface finish in entire stem shaft Distal flutes increase rotational stability. 4 5

Seal lock TM - Acetabular System Acetabular component is composed od Ti-6A1-4V ELI biomaterial and its anatomical structure conforms the most common and popular design and shape, which is hemispherical acetabular component. The design focused on to minimize the stress concentration, which in turn will minimize the debris production. Mighty TM highly cross linked polyethylene liners showed the lower wear rate of 0.18mg per million cycles than the commercially available highly cross linked polyethylene liners in the market. Mighty TM highly cross linked polyethylene surface after 5 million Cycles. Plasma sprayed surfaces are clinically well proven and have been in use for a number of years. Plasma sprayed surfaces allow for the thickness and roughness of the coating to be tuned in order to optimise the performance of the fixation surface, which in this case has 322 of Titanium, 85 of pore size and a roughness of Rz >200 Ceramic on ceramic bearing couple - the most logical approach in wear resistant tribology. Oxidation Index Mighty TM highly cross linked polyethylene samples tested, before and after accelerated aging. All samples were tested in accordance with Orthoplastics and ASTM 2102-01e1 (The Standard Guide for Evaluating the Extent of Oxidation in Ultra-High-Molecular-Weight polyethylene Fabricated Forms Intended for Surgical Implants) Aging was conducted in accordance with ASTM F2003-02 (The Standard Practise For accelerated aging of Ultra high Molecular weight Polyethylene after gamma Irradiated). Assembled with 28 mm head, acetabular component enables mean 140 degrees of ROM. At the lower portion of acetabular component, a barrier for rotation and direction control exists. In the Flat liner, direction control sulcus exists to control 40 degress of motion. 10 Degree Elevated liner allowed approximately 30 degrees of rotation.

Seal lock TM - Bipolar System Biomechanical Principle of Positive eccentricity As downward force is applied, the 2 different points of rotation between the shell and femoral head center align themselves to the proper anatomical position and proper load distribution. These stable action can be achieved through the principle of positive eccentricity. This dual articulation was primary inner articulation to reduce secondary outer acetabular articulation and acetabular wear The bipolar cup system was designed to require very little pressure to snap the polyethylene insert over the femoral head and next, to slide the metal cup over the insert. In revision cases, the bipolar cup system can be easy disassembled and removed with intact femoral head. Introduction Because the insert designed to be unitary structure, generation of debris from the impingement between parts can be minimize compared with other liners in the market. The fixation mode of acetabular component is primarily mechanical and dependent on a physical interlock between the cup and reamed acetabulum and secondary fixation is biological and is with osseous integration at the implant-bone interface by means of bone growth onto or into the substrate. For achieving long term clinical success it is essential that this stable fixation between the implant and the bone must be maintained, even after complete resorption of the hydroxyapatite. This can only be achieved with stable press fit design of acetabular cup. The Seal lock TM cup is capable of achieving excellent stability with the press fit design and porous coating using press fit technique. The design philosophy of Seal lock TM provides a fully congruent shell to polyethylene liner interface contact from exciting tolerances, secure locking mechanism, optimal thickness of polyethylene liner, which reduces the wear rate and stress that lead to failure. 6 7