You make us tic. Leading an active life... syntic. contic + biotic + The first choice in the device-assisted conservative therapy of incontinence

Similar documents
Electrotherapy, ultrasound therapy, combined therapy, laser therapy and magnetotherapy Etius ULM

PE R I PR OB E PERINEAL PROBES FOR THE TREATMENT OF INCONTINENCE BY ELECTROSTIMULATION & BIOFEEDBACK

EMG Biofeedback Device

Practical Guidelines For the Enraf-Nonius Commercial Training Myomed 632

LEADING THERAPY IN A NEW DIRECTION!

All for Rehabilitation

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

MagPro by MagVenture. Versatility in Magnetic Stimulation

Muscle Stimulation. Page 1

Intelect Advanced EPR

MagPro by MagVenture. Versatility in Magnetic Stimulation

MAGPRO. Versatility in Magnetic Stimulation. For clinical and research use

Ultrasound & Laser Therapy

tvns device for Non-invasive stimulation of the Vagus Nerve

InWave. User s Manual

Erigo User Script 1. Erigo Background Information. 2. Intended use and indications

Soleoline, high-performance

Neurostyle. Medical Innovation for Better Life

Puls 2.0 Radial Pulse Therapy

ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H

FILE INFORMATION. 3RD GENERATION PROFESSIONAL MULTI-USER PACK and what generation are you?

A over-the-counter medical device that utilizes muscle stimulation for the treatment of stress, urge and mixed urinary incontinence.

TARGETED RADIOFREQUENCY THERAPY

For Professionals. SYNCHRONY System. In Sync with Natural Hearing

YOU RE BETTER WITHOUT PAIN.

MYOMED 632X MYOMED 632X = MYOFEEDBACK MYOMED 632X = ALSO PRESSURE FEEDBACK MYOMED 632X = ALSO ELECTROTHERAPY V = ALSO VACUUM U = ALSO ULTRASOUND

OPERATING INSTRUCTIONS ENGLISH

Oscilla - excellence since 1960

Gymna 400 series. Your hands, our design. G Y M N A 400 S E R I E S 1

PHYSICAL THERAPY. Combination therapy. Laser therapy. Traction therapy MAGCELL. Electrotherapy. Shockwave therapy. Cryotherapy.

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

PFL780 PCB Fault Locator

THE NEW 4 SERIES. Complete, easy-to-use, fast and the responsible choice!

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

DISTRIBUTOR KIT EXPORT EN

The Sonopuls 492: the complete, easy-to-use, fast and responsible ensures that you can apply ultrasound therapy, electrotherapy and

TARGETED RADIOFREQUENCY THERAPY

ISIS IOM. System-Family. The new ISIS Xpress supplements the ISIS IOM System-Family >> APPLICATION FIELDS: >> Powerful >> User-friendly >> Flexible

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

myaudiometer. It s familiar, and it s so much

NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

Introducing MagPro XP with Cool TwinCoil for Magnetic Seizure Therapy

Reliable, flexible & precise

Liberty Pelvic Floor Stimulation

TESLA Stym REHABILITATION NEURO-PHYSIOTHERAPY SPORT MEDICINE

UROstim 2. Transcutaneous Muscle And Nerve Stimulator For the treatment of incontinence and for uro-genital use. Instruction Manual Art. no.

The Praxis FES System and Bladder/Bowel Management in Patients with Spinal Cord Injury

PHYSICAL THERAPY. Combination therapy. Laser therapy. Traction therapy MAGCELL. Electrotherapy. Shockwave therapy. Cryotherapy.

b e y o n d e x p e c t a t i o n

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

SONOPULS 492. The Sonopuls 492: the complete, easy-to-use, fast and responsible choice for ultrasound therapy, electrotherapy and combination therapy!

Myomed 632: The most complete device for safe treatments Myofeedback, pressure feedback, electrotherapy and ultrasound

OHTAC Recommendation

CONSET BROCHURE SEPTEMBER 2017 MANUFACTURERS OF ELECTRIC SIT-STAND DESKS

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Telephone

The ideal tool for early detection and monitoring of AMD.

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

ERO SCAN. Otoacoustic Emission Testing

Neuro-Audio Version 2010

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

MRI Ergometer Pedal. Medication free, load adjusted patient activation during MRI scans. Unique ergometer for MRI.

iworx Sample Lab Experiment HP-7: Hypothesis-driven Biofeedback Lab/Research Study

PRP-100-GB. Instruction Manual

THE NEW HOME FOR C-FLEX IS BUILT ON THE IDEA THAT A BETTER NIGHT S SLEEP COMES FROM PRODUCTS THAT ARE EASY TO USE.

The Portable Performance

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

Allergy Reliever. User Manual. AR 1 Series

Women s Lifetime Partner

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

HANDS-FREE ULTRASOUND

Electromagnetic. Leading Rehabilitation Technology

SONOPULS 490 SONOPULS 490

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Navigated Laser Therapy. A New Era in Retinal Disease Management

Coding for Sacral Neuromodulation

LABORIE. Disposables and Accessories Catalogue.

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

Professional body composition analysis: BODYSTAT I500. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

SEAL OF EXCELLENCE Henry Schein. Thermometers Oral 416. Aural Touch free 461, THERMOMETERS ALL PRICES EXCLUDE VAT

PROFESSIONAL FITNESS & WELLBEING CATALOGUE

03/13/18. A. Symptoms lasting for greater than or equal to 12 months that have resulted to significant impairment in activities of daily living; and

EE 791 Lecture 10. FES April 1, EE 791 Lecture 10 1

EXTERNAL TEMPORARY PACEMAKERS

BSD-2000 Hyperthermia System

ECG MACHINE KEC- Series

Ultrasound, Laser & Electrotherapy Therapy

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Mother Nurture User Instructions

PELVIC PHYSIOTHERAPY EDUCATION GUIDELINE

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Technologies and architectures" Stimulator, electrodes, system flexibility, reliability, security, etc."

Electromagnetic Prostate Cancer Detector

Revolutionary Electrotherapy

Transcription:

Leading an active life... p r e m i u m l i n e You make us tic syntic biotic + contic + The first choice in the device-assisted conservative therapy of incontinence

Multifunctional and nevertheless customized... syntic An optimal synergetic effect of functional electrostimulation (FES) and biofeedback for incontinence therapy ELECTROSTIMULATION & BIOFEEDBACK contic + An effective incontinence treatment with specific nerve- and muscle-stimulation ELECTROSTIMULATION biotic + The active incontinence therapy based on biofeedback BIOFEEDBACK

p r e m i u m l i n e THE CHALLENGE THE SOLUTION - p r e m i u m l i n e To meet the individual requirements for an efficient and conservative treatment of different types of incontinence. The customized premium solution in incontinence hometreatment devices! Unique Portfolio Doctor s + patient s benefit Transparency of therapy + evaluation Enhanced therapy options Perfectly matched accessories Quality and commitment Depending on type, severity of incontinence and patient s compliance the physician can choose among various non-active/active based devices for an optimized therapy setup sophisticated electrostimulation to strengthen the pelvic floor muscles and for neurogenic bladder deseases biofeedback (EMG-based) for active and motivated patients combination device (EMG+Stimulation) for high efficiency especially designed for hometreatment application preset parameters widely approved for common types of incontinence paramenters adjustable in a wide range to fit special requirements (scientific studies) easy to use mostly self-explanatory ergonomical design high patient safety due to a multitude of safety functions To assist the physician in improving the outcome of the therapy all relevant parameters and compliance data are recorded during the treatment sessions. With the optional infrared docking station doctic and the enhanced PC-Software solution all data can be visualized, processed and documented conveniently. With the add-on software solution for online presentation the patient can be teached-in to improve cooperation and compliance prior to therapy start. Especially the biofeedback video-animation gives a playfull introduction to children resulting in extremly motivated small patients. To improve the effect of the therapy the devices are used along with specially developed electrodes anatomical intracorporalelectrodes (rectal + vaginal) made of hypoallergenic materials for electrostimulation & biofeedback intravesical electrodes for treatment of neurogenic bladder disorders EMG surface electrodes with high conductivity, TENS electrodes In accordance with the european MDD tic is a certified company complying with all regulations for the development, production and distribution of active medical products. In close cooperation with medical specialists and practitioners our R&D department is working consequently on new and unique therapy devices to serve our customers and patients. All our products are CE-marked and developed in accordance with the european directive for medical products 93/42/EEC.

syntic... the ultimate solution in combined electrotherapy and biofeedback for the treatment of incontinence... The principle of operation is based on the combination of electrostimulation and biofeedback during a treatment session: the sensation of perceptible contractions of the pelvic floor muscles induced by the electrostimulation improves the awareness of the patient how to flex and to support them intentionally. This kind of reeducational training is actively assisted by the build-in biofeedback function resulting in an exceptional outcome in strengthening of the weak pelvic floor/sphincter in regaining continence. touch proof connector standard battery ergonomical design Windows-software doctic+ docking station multifunctional analysis ELECTROSTIMULATION & BIOFEEDBACK

p r e m i u m l i n e syntic Therapeutic indications stress incontinence I -II fecal incontinence I -II etc. Different preset programs match exactly with the therapeutical needs EMG-triggered stimulation alternation of passive and active training during a treatment session (biofeedback-fes-biofeedback) functional electrostimulation (FES, stress/urge) pure biofeedback all empirical defined parameters can be adjusted individually optional PC-software suite example for compliance data EMG-based biofeedback The unique concept allows the EMGmeasurement with the intracorporal stimulation electrodes without an additional reference electrode! Different sophisticated EMG-programs (manual/automatic mode) fulfill the needs of the patient. Different output-patterns adjustable biphasic rectangular pulses monophasic + pulses monophasic - pulses

contic +... the first choice in electrostimulation therapy for the treatment of incontinence... Over the years Functional Electrical Stimulation (FES) has become a quasi gold standard in the conservative treatment of various types of incontinence. The main principle is based on the strengthening of the weak pelvic floor muscles (stress incontinence) with electrical pulses and on the damping effect of nerves (urge incontinence, neurogenic deseases) by electrostimulation. Due to its passive character this therapy is especially indicated for patients with low compliance. dual stimulation capability standard battery ergonomical design Windows-software doctic+ docking station ELECTROSTIMULATION multifunctional analysis

p r e m i u m l i n e contic + Therapeutic indications stress incontinence II urge incontinence mixed stress/urge incontinence neurogenic bladder deseases (lazy bladder) hypotonic bladder (intravesical electrostimulation) fecal incontinence etc. Different preset programs match exactly with the therapeutical needs stress (50 Hz) urge (10 Hz) burst (5 Hz) neurogenic bladder dysfunction (25 Hz) all parameters are adjustable by the physician giving the performance of stationary devices optional PC-software suite example for compliance data Unique intracorporal electrodes In combination with the anatomical approved electrodes the therapeutical currents can be applied exactly. Due to their special design a dual stimulation with different parameters for each channel can be accomplished during one session, so mixed incontinencies can be treated at the same time! Different output-patterns adjustable biphasic rectangular pulses monophasic + pulses monophasic - pulses

biotic +... setting standards in the modern biofeedback-therapy for the treatment of incontinence... EMG-based biofeedback has become a promising approach in the therapy of muscular induced incontinencies like stress-incontinence and also has proven its superior efficiency in the treatment of detrusor-sphincter dysfunctions. The sophisticated electronical concept of the biotic + allows the recording of even very low electrical myographic signals coming from the pelvic floor muscles during active exercises. Sophisticated data processing is used to give back a significant optical feedback to support the patient in accomplishing further correct contractions/relaxations. Biofeedback-training for strengthening the pelvic floor muscles is the ideal choice for patients with high compliance. touch proof connector standard battery ergonomical design Windows-software doctic+ docking station multifunctional analysis BIOFEEDBACK

p r e m i u m l i n e biotic + Therapeutic indications stress incontinence I mixed stress/urge incontinence detrusor-sphincter dysynergy fecal incontinence etc. EMG-based biofeedback optical feedback with bargraph or smiley optimal performance with anatomically approved intracorporal probes (no external reference electrode required!) alternatively surface electrodes resolution down to µv guarantees best results optional PC-software suite examples of PC-Software Different preset programs relaxation exercises exercises to build-up the pelvic floor muscles parameters can be adjusted to meet the patient s needs Easy to use no calibration neccessary by the patient automatic gain control giving much comfort Online-animation with the optional docking station and PC software suite animation suitable for children sophisticated documentation and analysis functions

Accessories / Electrodes / Disposables rectal probe vaginal probe EMG surface electrodes 22 x 30 mm EMG surface electrodes 37 mm round TENS electrode 50 x 90 mm intravesical probes small intracorporal probe TENS electrode 32 mm round TENS electrode 50 x 50 mm syntic vaginal probe (multi channel) rectal probe (multi channel) small intracorporal probe (multi channel) TENS electrodes - with low skin irritation (32 mm round, 50 x 50 mm) high-conductivity EMG surface electrodes (37 mm round, 22 x 30 mm - with snap adapter) contic + vaginal probe (multi channel) rectal probe (multi channel) small intracorporal probe (multi channel) intravesical probe (set incl. cable + TENS electrodes) TENS electrodes - with low skin irritation (32 mm round, 50 x 50 mm, 50 x 90 mm) biotic + vaginal probe (multi channel) rectal probe (multi channel) small intracorporal probe (multi channel) high-conductivity EMG surface electrodes (37 mm round, 22 x 30 mm - with snap adapter) All intracoporal probes are made of hypoallergenic materials and are tested for biocompatibility (ISO10993 cytotoxicity, sensitation, irritation). The intracoporal probes can be used along with all tic therapy devices.

p r e m i u m l i n e syntic therapeutic indications: programs (preset): stimulation module: modulation: frequency range: pulse width: pulse patterns: biofeedback module: resolution, sensitivity: calibration/range: CMMR: electrodes: contic + therapeutic indications: ELECTROSTIMULATION & BIOFEEDBACK stress incontinence I -II, fecal incontinence I -II stress FES, urge, biofeedback, alt. FES-biofeedback, EMG triggered electrostimulation 1 channel, constant current output amplitude modulation (AM), frequency modulation (FM), burst stimulation, continuous stimulation 1 Hz - 150 Hz 50 µs - 500 µs biphasic (compensated), monophasic +, monophasic - 1 channel, EMG-amplifier 1 µv - 500 µv, 1 µv automatic gain control (AGC) 0482 > 100 db risc class (MDD): II a vaginal-, rectal-, small intracorporal probe, TENS electrodes, EMG surface electrodes ELECTROSTIMULATION stress incontinence II, urge incontinence, mixed stress/urge incontinence, fecal incontinence neurogenic bladder deseases (lazy bladder), hypotonic bladder (intravesical electrostimulation) programs (preset): stimulation module: modulation: frequency range: pulse width: pulse patterns: electrodes: biotic + therapeutic indications: stress FES, urge, burst 2 channel, constant current output, each channel individually adjustable, simultaneous stimulation with different programs amplitude modulation (AM), frequency modulation (FM), burst stimulation, continuous stimulation 1 Hz - 150 Hz 50 µs - 250 µs biphasic (compensated), monophasic +, monophasic - 0482 risc class (MDD): II a vaginal-, rectal-, small intracorporal probe, TENS electrodes, intravesical probe BIOFEEDBACK stress incontinence I, mixed stress/urge incontinence, detrusor-sphincter dysfunction, fecal incontinence programs (preset): muscle training, muscle relaxation biofeedback module: display: resolution, sensitivity: calibration/range: CMMR: electrodes: 1 channel, EMG-amplifier bargraph, smiley 1 µv - 500 µv, 1 µv automatic gain control (AGC) > 100 db vaginal-, rectal-, small intracorporal probe, EMG surface electrodes 0482 risc class (MDD): I general: battery: dimensions + weight: CE-declaration: all programs and parameters are adjustable by the user 128 segment LC-Display fully digital integrated HW/SW-safety functions touch-proof connectors IR-interface (optional docking station required) 9V alcaline cell (6LXXX/9V) 140 mm x 70 mm x 40 mm, 115 g (without battery) in accordance with the directive 93/42/EEC for medical products

Leading an active life... You make us tic MANUFACTURER: GmbH & Co. KG Endelner Feld 9 D - 46286 Dorsten Fon: +49 (0) 23 69. 20 85-0 Fax: +49 (0) 23 69. 20 85-10 email: info@ticmed.de Web: www.ticmed.de Shop: www.tic-direkt.de DISTRIBUTOR: 07/2012 / R2 CG