JACC: CLINICAL ELECTROPHYSIOLOGY VOL. 3, NO. 10, 2017 ª 2017 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION

Similar documents
Basic concepts, techniques and safety issues of arrhythmia ablation

Ablation Lesion Assessment

Mapping and Ablation in AF: how can we evaluate the lesion formation?

Just over a decade ago, the advent of tip temperature monitoring during radiofrequency (RF) energy

Raphael Rosso MD, Yuval Levi Med. Eng., Sami Viskin MD Tel Aviv Sourasky Medical Center

Radiofrequency Energy: Irrigation and Alternate Catheters. Andreas Pflaumer

Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary Vein

Review Article Irrigated Tip Catheters for Radiofrequency Ablation in Ventricular Tachycardia

Comparison of Irrigated Electrode Designs for Radiofrequency Ablation of Myocardium

Several experimental studies have shown that electrode-tissue. Original Article

Initial Experience Using AutoMark in Atrial Fibrillation Ablation

Ablation Index : A new standard for Safety and Efficacy. Dr Franck Halimi Hôpital Privé Parly 2 Le Chesnay, France

The Future of Catheter Ablation

Introduction. Material and methods

The first human experience of a contact force sensing catheter for epicardial ablation of ventricular tachycardia

Complex Left Atrial (CLA) Best Practices for Navigant

The presence of epicardial circuits may adversely affect

Author s Accepted Manuscript

Computational Modeling to Study the Treatment of Cardiac Arrhythmias using Radiofrequency Ablation

CLINICAL COMPENDIUM. The HeartLight Endoscopic Ablation System Putting a New Level of PVI Precision Close at Hand. CardioFocus.com

480 April 2004 PACE, Vol. 27

Voltage-directed Cavo-tricuspid Isthmus Ablation using Novel Ablation Catheter Mapping Technology

Στροφείς (rotors) και πραγματικότητα. Χάρης Κοσσυβάκης Επιμελητής A Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ»

Catheter Ablation of Atrial Fibrillation Strategy and Outcome Predictors Shih-Ann Chen MD

Time to recurrence of atrial fibrillation influences outcome following catheter ablation

Precise lesion formation is crucial for successful

Biphasic Clinical Summaries

Atrial ectopic beats within the pulmonary veins (PVs) are

Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions

20% 10/9/2018. Fluoroless Ablation relinquishing an old habit. Prevalence of Atrial Fibrillation. Atrial Fibrillation is a Progressive Disease

Επιπλοκές κατάλυσης πνευµονικών φλεβών

AF ABLATION Concepts and Techniques

Characteristics of the atrial repolarization phase of the ECG in paroxysmal atrial fibrillation patients and controls

How to ablate typical atrial flutter

University of Groningen. Ablation of atrial fibrillation de Maat, Gijs Eduard

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

Percutaneous Transvenous Atrial Fibrillation Ablation and Stroke

Effects of myocardial infarction on catheter defibrillation threshold

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P.

Contemporary Strategies for Catheter Ablation of Atrial Fibrillation

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

Linear Ablation Should Not Be a Standard Part of Ablation in Persistent AF. Disclosures. LA Ablation vs. Segmental Ostial Ablation With PVI for PAF

Surgical Ablation for Lone AF: What have we learned after 30 years?

SUPPLEMENTAL MATERIAL

A request for a log book extension must be put in writing and sent to BHRS, Unit 6B, Essex House, Cromwell Business Park, Chipping Norton,

Dr Mark Earley MD FRCP Consultant Cardiologist

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Case Report Catheter ablation of Atrial Incisional Tachycardia mistaken for Atrial flutter

Pulmonary vein isolation (PVI) has become the cornerstone. Original Article

ICD THERAPIES: are they harmful or just high risk markers?

Radiofrequency Ablation at Low Irrigation Flow Rates Using a Novel 12-Hole Gold Open-Irrigation Catheter

Reentry in a Pulmonary Vein as a Possible Mechanism of Focal Atrial Fibrillation

Catheter Ablation of Atrial Tachycardia Originating from the Tip of Right Atrial Appendage

Potassium Efflux from Myocardial Cells Induced by Defibrillator Shock

Cardiac Imaging in abnormal rhythm Role of MDCT

Mapping techniques in AFib. Helmut Pürerfellner, MD Public Hospital Elisabethinen Academic Teaching Hospital Linz, Austria

A Cryo Anatomical Procedure to Everyone? Saverio Iacopino, FACC, FESC

Outcomes of AF Ablation

Arrhythmia/Electrophysiology

Electrophysiologic Properties of Pulmonary Veins Assessed Using a Multielectrode Basket Catheter

CLINICAL COMPENDIUM. The HeartLight Endoscopic Ablation System Putting a New Level of PVI Precision Close at Hand. CardioFocus.com

Η χρήση των νέων καθετήρων με αισθητήρα πίεσης Κλινικά δεδομένα και παραδείγματα

Bipolar Radiofrequency Energy

Computational Modeling to Study the Treatment of Cardiac Arrhythmias using Radiofrequency Ablation

Intra-Arterial Blood Pressure Monitoring

Κατάλυση παροξυσμικής κολπικής μαρμαρυγής Ποια τεχνολογία και σε ποιους ασθενείς; Χάρης Κοσσυβάκης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ.

Cardiovascular Physiology

Ankara, Turkey 2 Department of Cardiology, Division of Arrhythmia and Electrophysiology, Yuksek Ihtisas

CATHETER ABLATION FOR TACHYCARDIAS

COMPLEX CASE STUDY INNOVATIVE COLLECTIONS. Case presentation

Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins

Biomedical Instrumentation

The Function of an ECG in Diagnosing Heart Conditions. A useful guide to the function of the heart s electrical system for patients receiving an ECG

The Cardiovascular System

Pulmonary Vein Antral Isolation Using an Open Irrigation Ablation Catheter for the Treatment of Atrial Fibrillation

Electrical disconnection of pulmonary vein (PV) myocardium

Impedance Monitoring During Radiofrequency Catheter Ablation in Humans

Advanced imaging of the left atrium - strain, CT, 3D, MRI -

Supporting Information

Μηνύματα από τις σπουδαιότερες μελέτες στην ηλεκτροφυσιολογία το διάστημα

Interventional solutions for atrial fibrillation in patients with heart failure

EDUCATION MEDICAL PROGRAMS EDUCATION AF SOLUTIONS TRAINING AND EDUCATION OVERVIEW ONLINE TRAINING PROGRAMS

Procurement Support to Ministry of Health, Ukraine. Invitation to Bid for:

Since pulmonary veins (PVs) have

Atrial Fibrillation: Classification and Electrophysiology. Saverio Iacopino, MD, FACC, FESC

Ο ΡOΛΟΣ ΤΗΣ ΑΠΕΙΚOΝΙΣΗΣ ΣΤΗΝ ΗΛΕΚΤΡΟΦΥΣΙΟΛΟΓIΑ - ΥΠΟΣΤΡΩΜΑ ΚΟΛΠΟΙ ΩΤΙΑ ΑΞΙΟΛΟΓΗΣΗ ΟΥΛΗΣ

Balloon and Mesh Catheter Ablation of Pulmonary Veins

Modeling of Anatomy, Electrophysiology and Tension Development in the Human Heart

Six Sigma Glossary Lean 6 Society

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Tailored Management of Atrial Fibrillation Using a LGE-MRI Based Model: From the Clinic to the Electrophysiology Laboratory

Journal of the American College of Cardiology Vol. 37, No. 2, by the American College of Cardiology ISSN /01/$20.

Role of LAA isolation in AF cure

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

Clinical Data Summary: Avoid FFS Study

Pulmonary vein isolation (PVI) is

Catheter ablation is one of the primary treatments for

PHONOCARDIOGRAPHY (PCG)

Transcription:

ª 2017 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION PUBLISHED BY ELSEVIER ISSN 2405-500X/$36.00 http://dx.doi.org/10.1016/j.jacep.2017.08.016 In Vitro Validation of the Lesion Size Index to Predict Lesion Width and Depth After Irrigated Radiofrequency Ablation in a Porcine Model Vittorio Calzolari, MD, a Luca De Mattia, MD, a Stefano Indiani, ENG, b Martino Crosato, MD, a Alberto Furlanetto, MD, c Claudia Licciardello, MENG, b Paolo Antonio Maria Squasi, MD, a Zoran Olivari, MD a ABSTRACT OBJECTIVES In an in vitro model, the authors tested the hypotheses that: 1) lesion dimensions correlate with lesion size index (LSI); and 2) LSI could predict lesion dimensions better than power, contact force (CF), and force time integral (FTI). BACKGROUND When performing radiofrequency (RF) catheter ablation for cardiac arrhythmias, reliable predictors of lesion quality are lacking. The LSI is a multiparametric index incorporating time, power, CF, and impedance recorded during ablation. METHODS RF lesions were created on porcine myocardial slabs by using an open-tip irrigated catheter capable of real-time monitoring of catheter tissue CF. Initially, 3 power settings of 20, 25, and 30 W were used with a fixed CF of 10 g. Afixed power of 20 W was then set with a CF of 20 and 30 g, thereby yielding a total of 5 ablation groups. In each group, LSI values of 5, 6, 7, and 8 were targeted. Sixty RF lesions were created by using 20 ablation protocols (3 lesions for each protocol). RESULTS Lesion width and depth were not correlated with power or CF, but the results significantly correlated with FTI (p < 0.01) and LSI (p < 0.0001). Four steam pops occurred with power set at 30 W; no pops were noted with 20 or 25 W even when high LSI values were targeted. CONCLUSIONS In this in vitro model, FTI and LSI predicted RF lesion dimensions, whereas power and CF did not. The LSI predictive value was higher than that of FTI. Steam pops occurred only using high ablation power levels, regardless of the targeted LSI. (J Am Coll Cardiol EP 2017;3:1126 35) 2017 by the American College of Cardiology Foundation. Radiofrequency (RF) catheter ablation is the therapy of choice for several cardiac arrhythmias. During ablation, proper RF delivery is crucial both to obtain an effective lesion and to avoid excessive heating that can possibly lead to thrombus formation, steam pop, and/or perforation. Parameters such as RF power, catheter tip temperature, and impedance drop are commonly monitored during RF delivery. However, these parameters display limited accuracy in assessing lesion quality, and more reliable indexes are needed. Conversely, the biophysics of RF lesion formation is known to be the result of a complex interplay of many factors, namely RF delivery time, catheter contact force (CF), power delivered, and tissue impedance. Recently, a novel, externally irrigated tip catheter has been developed, allowing real-time monitoring of in vivo catheter tissue CF by means of optical fibers (1). This catheter offers the opportunity to obtain novel ablation indexes, such as force time integral (FTI) (2). From the a Department of Cardiology, Ca Foncello Hospital, Treviso, Italy; b St. Jude Medical Italia, Agrate Brianza, Italy; and the c Department of Anatomical Pathology, Ca Foncello Hospital, Treviso, Italy. Drs. Indiani and Licciardello are St. Jude Medical Italia employees. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose. All authors attest they are in compliance with human studies committees and animal welfare regulations of the authors institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the JACC: Clinical Electrophysiology author instructions page. Manuscript received June 1, 2017; revised manuscript received August 10, 2017, accepted August 31, 2017.

OCTOBER 2017:1126 35 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size 1127 FTI was shown to correlate with lesion size in an in vitro model (3) and to predict lesion size and steam pop occurrence in the beating canine heart (4). The lesion size index (LSI) is another multiparametric index that incorporates time, power, CF, and impedance data recorded during RF ablation in a weighted formula; it could therefore more precisely describe the complexity of in vivo ablation biophysics and help to predict the extent of myocardial tissue lesions (5,6). In the present study, an in vitro model tested the hypotheses that: 1) lesion dimensions correlate with LSI; and 2) LSI could be a better predictor of lesion dimensions than power, CF, and FTI. As a secondary endpoint, we investigated if 1 of these variables could help to predict the occurrence of steam pops. METHODS FORCE-SENSING CATHETER. A 7-F, 3.5-mm open-tip irrigated TactiCath Quartz (St. Jude Medical, St. Paul, Minnesota) ablation catheter was used for the experiment. As previously described (3), this catheter has a force sensor incorporated into ABBREVIATIONS AND ACRONYMS its distal part, which consists of a deformable body and 3 optical fibers that use infrared CF = contact force laser light to measure microdeformations FTI = force time integral caused by forces applied to the tip of the catheter. LSI = lesion size index RF = radiofrequency FORCE TIME INTEGRAL. FTI is defined as the total area under the CF curve (contact FTI) applied during RF application, as previously described (3). FTI was found to predict the clinical outcomes in patients with paroxysmal atrial fibrillation after pulmonary vein isolation (5). FTI is derived from a simple multiplication of CF by time and does not take into account the important role of power delivery. LESION SIZE INDEX. LSI is a novel ablation index that incorporates CF between the ablation tip and target tissue, impedance, power applied, and FIGURE 1 In Vitro Experimental Setup (A) Contact force catheter interface. (B) Ampere RF generator (St. Jude Medical, St. Paul, Minnesota). (C) CoolPoint irrigation pump (St. Jude Medical). (D) NavX electroanatomic mapping system (Endocardial Solutions, St. Jude Medical). (E) Saline bath. (F) Ground platform. (G) Porcine heart. (H) Non-pulsatile pump. (Arrow) TactiCath ablation catheter (St. Jude Medical).

1128 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size OCTOBER 2017:1126 35 FIGURE 2 Schematic Representation of Lesions After RF Ablation (A) A schematic representation of lesion width after radiofrequency (RF) ablation. Top row: a schematic representation of lesion width after RF ablations using a constant contact force (CF) of 10 g and power of 20 W (upper left panel), 25W(middle), and 30 W (upper right panel), respectively. For a given power output, 4 different levels of lesion size index (LSI) (5, 6, 7, and 8) were targeted. Three lesions were obtained by using the same combination of CF, power, and LSI. Left-hand panel: width of lesions obtained by using a constant power of 20 W and a CF of 10, 20, and 30 g. For any CF value, 4 different levels of LSI (5, 6, 7, and 8) were targeted. Main diagram (lower right panel): width of lesions obtained with different LSI values, regardless of the combination of CF and power applied. The lesion width was significantly correlated to LSI (p < 0.0001). Continued on the next page duration of RF delivery (6). An empirical model of the effect of these parameters was developed from a series of in vivo experiments encompassing >3,000 lesions in both animals and humans, considering the nonlinear behavior of lesion formation due to the heterogeneity of concurring factors. These factors include: 1) the shift from resistive (joule) heating during the early phase of lesion formation to diffusive (conductive) heating during a later phase; 2) the delay between the variation of force and/or current and the change in lesion growth rate due to thermal latency; and 3) thefactthatlesionsrapidly grow to a certain depth (typically about 3 mm), beyond which the lesion depth increases at a slower rate. The equation describing the LSI model is as follows: LSI ðf; I; tþ ¼k 1 f 2 1 e F=f1 þ f 0 i 2 1 e ði=i1þ2 nð1 k 0 Þþk 0 h1 e t=s. 1 e 60=sio where f 0,f 1,andf 2 are force parameter coefficients, i 1 and i 2 are electrical current coefficients, k 0 is a diffusive heating coefficient, and s is a characteristic time value. The coefficients are the results of best curve fitting of experimental data acquired during preclinical studies. The equation comprises a resistive heating component (1-k 0 ) that is independent of time; resistive heating occurs in the first 3 to 5 s of RF delivery and accounts for a maximum lesion depth up to 4 mm. The

OCTOBER 2017:1126 35 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size 1129 FIGURE 2 Continued (B) A schematic representation of lesion depth after RF ablation. Top row: a schematic representation of lesion depth after RF ablations using a constant CF of 10 g and power of 20 W (upper left panel), 25W(middle), and 30 W (upper right panel). For a given power output, 4 different levels of LSI (5, 6, 7, and 8) were targeted. Three lesions were obtained by using the same combination of CF, power, and LSI. Left-hand panel: depth of lesions obtained by using a constant power of 20 W and CF of 10, 20 and 30 g. For any CF value, 4 different levels of LSI (5, 6, 7, and 8) were targeted. Main diagram (lower right panel): depth of lesions obtained with different LSI levels, regardless of the combination of CF and power applied. The lesion depth was significantly correlated to LSI (p < 0.0001). y-axis ¼ lesion width/depth (millimeters); x-axis ¼ LSI. The dashed lines represent 95% confidence intervals. diffusive heating component, k 0 [(1-e t/s )/(1 e 60/s )] in the equation, is time dependent, slower (30 to 50 s), reaches a maximum depth of 6 to 9 mm, and reflects heat conduction from the initial resistive lesion (6). However, LSI has never been validated in a prospective study or in in vitro or in vivo studies. EXPERIMENTAL SETUP. The TactiCath Quartz catheter was mounted in a fixed standard 8-F, 11-cm sheath and manually maneuvered over a ground platform placed within a tank filled with circulating physiological saline solution at room temperature (Figure 1). The circulating bath used a pump to produce nonpulsatile flow directed perpendicularly to the myocardium surface at a rate of 5 l/min. Fresh porcine heart muscle slabs (thickness of 2 to 4 cm, taken from the mid-myocardial layer of the left ventricle) were submerged in the saline bath. The animal tissue was purchased from a local butcher, and no procedures were performed on live animals. The tip of the ablation catheter was held parallel tothemyocardialtissuesurfaceandmaneuveredby means of the control knob to obtain various CF intensities at different stages of the experiment. CF, temperature, impedance, FTI, and LSI values were continuously monitored during RF delivery by using the EnSite Velocity cardiac mapping system (St. Jude Medical). A calibrated roller pump (CoolPoint, St. Jude Medical) connected to the catheter delivered saline solution at 17 ml/min during RF delivery. An Ampere RF generator (St. Jude Medical) was connected to deliver 550 khz unmodulated sine-wave RF energy pulses in a temperature-controlled mode (maximum temperature 41 C). Different power settings and CF intensities were used during the experiment, as discussed in the following sections.

1130 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size OCTOBER 2017:1126 35 TABLE 1 ABLATION PROTOCOL. To obtain a range of lesion sizes, myocardial lesions were first created at separatesiteswithconstantcfintensity(10g)andpower settings of 20, 25, and 30 W. For each power setting, RF Delivery Time and FTI Values Recorded CF (g) FIGURE 3 20 W 25 W 30 W T(s) FTI(g s) T (s) FTI (g s) T (s) FTI (g s) LSI ¼ 5 10 23 2 227 23 30 2 310 12 13 1 127 12 20 15 1 299 29 30 8 1 249 39 LSI ¼ 6 10 36 1 369 7 30 3 358 23 24 5* 243 52 20 29 6 596 108 30 24 1 711 25 LSI ¼ 7 10 66 5 664 66 41 3 471 26 36 1 356 3 20 50 3 1,035 90 30 31 1 916 22 LSI ¼ 8 10 200 5 2,049 69 92 30 954 240 47 3* 541 10 20 70 26 1,418 474 30 46 3 1,399 46 RF Lesion With Steam Pop Formation A transverse section through a cooled lesion after a steam pop occurred during RF ablation (power 30 W, contact force 10 g, LSI ¼ 7). The intramyocardial structure is altered and teared by gas bubbles as a consequence of sudden overheating. The central lesion shows a crater and signs of carbonization (arrows). Abbreviations as in Figure 2. Values are mean SD. Radiofrequency (RF) delivery time and force time integral (FTI) were recorded with different ablation protocols: 4 different lesion size index (LSI) levels (left column) were targeted by using different contact force (CF column) and power (upper line) settings. For CF ¼ 10 g, 3 power levels were used (20, 25, and 30 W, respectively), whereas for CF ¼ 20 and 30 g, a single power output of 20 W was set (see text). Empty boxes: lesions with CF of 20 and 30 g with power settings of 25 and 30 W were not performed. *One steam pop. Two steam pops. (Note that steam pops occurred only when a 30 W power output was set, regardless of the LSI target values.) RF delivery was maintained to achieve a given LSI value (5, 6, 7, and 8). Three separate lesions were obtained for each LSI target value (total of 36 lesions) (Figures 2A and 2B). In the second phase of the study, additional myocardial lesions were created with a fixed power (20 W) and 2 different force settings (20 and 30 g). For each force value, RF pulse delivery time was titrated to achieve LSI values of 5, 6, 7, and 8. Three separate lesions were obtained for each LSI target value (total of 24 lesions). After every lesion, the ablation electrode and the electrode tissue interface were examined for char formation. The occurrence of an audible pop was noted (Figure 3). The study design excluded lesions with LSI lower than 5, which needed a very short time of RF delivery, thus preventing complete lesion formation. Moreover, lesions with LSI higher than 8 required excessively long RF pulses (>90 s) even with high-power settings (Table 1) and were therefore not considered (steady state for lesion formation is typically reached between 45 and 60 s) (7). LESION ASSESSMENT. After RF delivery, the myocardium was cross-sectioned at the level of each lesion. Themaximumwidthanddepthvaluesoftheblanched zone of the lesion (Figure 4) were measured with a dial caliper with a resolution of 0.1 mm by 1 observer; the observer was not blinded to the lesion protocol. STATISTICAL ANALYSIS. Data are expressed as mean SD. Descriptive statistics were calculated for variables of interest. The significance of the relationship between lesion size (depth and width) and the different levels of power, force, FTI, and LSI was assessed by means of univariate and multivariate linear regression analysis and analysis of variance. Depth or width was used as the dependent variable and LSI, power, and force as effects. Significant differences were further evaluated by using Bonferroni s method for pairwise multiple comparisons. Values of p < 0.05 were considered statistically significant. Statistical analysis was performed by using IBM-SPSS version 23.01 (IBM SPSS Statistics, IBM Corporation, Armonk, New York) and STATISTICA version 12 (StatSoft, Tulsa, Oklahoma) statistical software. RESULTS A total of 60 RF applications were delivered (15 lesions for every LSI value, obtained by varying the intensity of CF or power). Mean impedance, as measured at the tip of the ablation catheter while in

OCTOBER 2017:1126 35 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size 1131 FIGURE 4 An Example of Lesion Size Measurements After RF Delivery TABLE 3 Effect of LSI, Force, and Power on Depth and Width of Experimental Lesions (Multiple Linear Regression) Depth (R ¼ 0.975; p < 0.001) Width (R ¼ 0.957; p < 0.001) BCoefficient p Value B Coefficient p Value CF 0.0005 0.9423 0.0068 0.4908 Power 0.0054 0.6800 0.0190 0.3199 LSI 1.0976 <0.0001 1.1622 <0.0001 Summary of multiple regression analysis for dependent variables depth and width, considering ablation CF, power, and LSI. LSI was the only predictor of lesion dimensions (p < 0.0001, bottom line). Abbreviations as in Table 1. An example of an RF lesion in the porcine myocardium (RF power 20 W, contact force 30 g, LSI ¼ 8). Note that the maximum lesion width is measured several millimeters beneath the myocardial surface (arrow). D¼ maximum lesion depth; W ¼ maximum lesion width; other abbreviations as in Figure 2. contact with the myocardium at the beginning of RF delivery, was 65 U Ohms and did not significantly change between the 4 CFs used. The width and depth of the obtained lesions are reported in Figures 2A and 2B and Table 2. With LSI level 5, the mean lesion width was 6.3 0.4 mm, and mean lesion depth was 2.7 0.4 mm. Ablation lesions targeting the lowest LSI value did not result in any popping phenomena. With LSI level 6, mean lesion width was 7.8 0.5 mm, and mean lesion depth was 3.9 0.2 mm. One pop was heard and crater formation was noted (Figure 3) during highpower (30 W, fixed power) ablation. With LSI level 7, mean lesion width was 9.0 0.4 mm, and mean lesion depth was 5.0 0.2 mm. Two pops were heard, with thrombus and crater formation during TABLE 2 RF Lesion Dimensions According to LSI Levels Lesion Width (mm) Lesion Depth (mm) No. of Lesions 5 6.3 0.4 2.7 0.4 15 6 7.8 0.5 3.9 0.2 15 7 9.0 0.4 5.0 0.2 15 8 9.9 0.4 6.0 0.2 15 Total 60 Values are mean SD. Lesion width and depth were measured targeting 4 different levels of LSI. For every LSI level, 15 lesions were obtained by using 5 different ablation protocols (see Methods). Abbreviations as in Table 1. high-power (30 W) ablation. With LSI level 8, mean lesion width was 9.9 0.4 mm, and mean lesion depth was 6.0 0.2 mm. One pop was heard, with thrombus and crater formation during high-power (30 W) ablation. The analysis of variance showed a great effect of LSI increment on lesion width (p < 0.0001) and depth (p < 0.0001). The Bonferroni s post hoc test confirmed that the lesion size (both width and depth) differed for each level of LSI (LSI 5 vs. LSI 6, and LSI 6 vs. LSI 7, and LSI 7 vs. LSI 8, and LSI 6 vs. LSI 7, and LSI 6 vs. LSI 8, and LSI 7 vs. LSI 8 were significantly different, p < 0.001). In summary, both lesion width and depth increased with increasing LSI target values, regardless of power values. For instance, lesions obtained with LSI level 8 using low CF (10 g) andpower(20w) settings were significantly larger than lesions obtained with higher CF (30 g) and similar power values (20 W) but targeting an LSI level of 5 (median width 9.9 mm vs. 6.3 mm; median depth 6 mm vs. 2.7 mm). Moreover, the time needed to achieve each LSI value decreased with increasing power or force values, whereas the FTI values increased with increasing LSI values. Instead, FTI correlation with power, and especially with force, was weaker. FACTORS AFFECTING ABLATION LESION SIZE. According to multiple linear regression analysis, ablation lesion size did not seem to correlate with power or CF (Table 3), whereas a significant correlation was seen between both FTI (p < 0.01) and LSI (p < 0.0001) (Figure 5) and lesion width and depth. Figure 6A displays the same relationships but highlighting 4 intervals of FTI. Figure 6B displays the relationships between the width and depth of lesions obtained by using the 4 different LSI levels. Such correlation resulted stronger for LSI than for FTI: the linear correlation coefficients for lesion dimensions resulted higher for LSI (r ¼ 0.95 for width and r ¼ 0.97

1132 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size OCTOBER 2017:1126 35 FIGURE 5 FTI Predictive Power of Lesion Size Compared With LSI Upper panels: the linear correlation coefficients for lesion width were lower for the force time integral (FTI) (r ¼ 0.66; green circle, upper left panel) than for LSI (r ¼ 0.95; red circle, upper right panel). Lower panels: the linear correlation coefficients for lesion depth were lower for FTI (r ¼ 0.71; green circle, lower left panel) than for LSI (r ¼ 0.97; red circle, lower right panel). The dashed lines represent 95% confidence intervals. Abbreviations as in Figure 2. fordepth)thanforfti(r¼0.66 for width and r ¼ 0.71 for depth) (Figure 5). Impedance drop during RF delivery was analyzed but did not exhibit any significant correlation with lesion size. FACTORS AFFECTING ABLATION SAFETY. No popping phenomena were observed with an RF power of 20 or 25 W, irrespective of the targeted LSI level (Table 1). Only when the power was set to 30 W did steam pops occur in 4 cases (1 pop with LSI level 6, 2 pops with LSI level 7, and 1 pop with LSI level 8). In cases in which pop occurred, the impedance values at the beginning and at the end of RF delivery were similar to those recorded in cases without pops, and no sudden impedance drop was noted. DISCUSSION MAIN FINDINGS. The main finding of the present in vitro study is that LSI is a better predictor of RF lesion dimensions than power, impedance CF, and FTI. In other words, given that the LSI formula takes into account force, power, and impedance, LSI was more predictive than each of its components if considered alone. Moreover, the plotted diagrams of width/depth and LSI allowed prediction of both the LSI value required to obtain a pre-specified lesion width/depth and prediction of the lesion width/depth after a RF lesion performed targeting a pre-specified LSI value (Figure 7).

OCTOBER 2017:1126 35 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size 1133 CORRELATION BETWEEN RF POWER AND LESION WIDTH/DEPTH. As mentioned earlier, in the first part of the study, 36 lesions were created by using a fixed force intensity (10 g) and 3 distinct power settings (20, 25, and 30 W [3 lesions for each power setting]) to achieve 4 different pre-specified LSI levels (5, 6, 7, and 8). To limit the number of lesions needed, the dataset obtained at each successive step was used to verify that the lesion size was independent of power output. Indeed, this assumption was supported by the lack of significant correlation between power/ lesion width (p ¼ 0.31) (Table 3) and power/lesion depth (p ¼ 0.67). Therefore, additional sets of lesions werecreatedonlywithafixed power setting of 20 W andcfvaluesof20and30gto achieve the 4 different LSI levels (5, 6, 7, and 8). COMPARISON BETWEEN FTI AND LSI. The value of FTI in predicting RF lesion dimensions has been previously explored and validated in both in vitro and clinical studies (3,5). However,FTIdescribesonly2(timeand force) of many factors involved in RF lesion formation, and it ignores the crucial role of power delivery in lesion creation (3). Conversely, LSI not only comprises CF, power, and time but describes other aspects of the biophysics of RF lesion formation (e.g., resistive heating and conductive heating). Therefore, LSI would be a more robust predictor of RF lesion size than FTI, as confirmed by our observations. FIGURE 6 Relationship Between the Width and Depth of Lesions Obtained With Similar FTI and LSI Levels CLINICAL UTILITY OF LSI. An audible pop and crater formation was noted only when the delivered power was 30 W; no complication was encountered with lower power values. Therefore, given that the most important determinant of lesion size in this study was LSI, even at low-power settings, it might be suggested that effective lesions could be safely created by using power settings <30 W, once it has been ascertained that appropriate LSI values have been obtained. By doing so, the required lesion width (e.g., to avoid lesion gaps when a linear lesion is required) and depth (e.g., to ensure lesion transmurality during pulmonary vein isolation) can be achieved even with low-power settings, thus enhancing both ablation effectiveness and safety (fewer steam pops). As discussed earlier, our results suggest that, at least in an in vitro setting, the LSI value needed to obtain a pre-specified lesion width/depth can be predicted, as well as the resulting lesion width/depth after an RF lesion performed with a given LSI value (Figure 7). (A) A schematic representation of the relationship between the width and depth of lesions obtained with similar FTI levels. Four subgroups were characterized: FTI <300 (green dots), FTI between 301 and 600 (red dots), FTI between 601 and 900 (pink dots), and FTI >901 (blue dots). Even if lesion dimensions were significantly correlated to FTI (p < 0.01) (Figure 5, left column), dots belonging to the same FTI subgroup are more scattered through the chart compared with points obtained with constant LSI levels (Figure 6B). (B) A schematic representation of the relationship between the width and depth of lesions obtained targeting 4 different LSI levels: 5 (green dots), 6(red dots), 7(pink dots), and8(blue dots). LSI was a significant predictor of lesion dimensions (p < 0.0001) (Figure 5, right column). The dashed lines represent 95% confidence intervals. Abbreviations as in Figures 2 and 5.

1134 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size OCTOBER 2017:1126 35 FIGURE 7 Two Examples of How LSI Could Guide RF Ablation Two examples of the in vitro predictive value of LSI in determining RF lesion width. Example A: to obtain a lesion width of 8 mm, an LSI value ranging from 6.2 to 6.4 should be targeted (red bar: 95% confidence interval). Example B: a lesion width of 9 to 9.2 mm (blue bar: 95% confidence interval) can be expected if an LSI level of 7.2 is targeted during RF ablation. Abbreviations as in Figure 2. If confirmed in in vivo studies, these data might providesomeguidanceforasafeandeffectivesetting of the power delivered during ablation with an irrigated-tip contact catheter. STUDY LIMITATIONS. The primary limitation of this studyisthatitwasperformedonaninvitromodel, which differed from a clinical setting in a number of significant ways, including the absence of cardiac motion. Moreover, the porcine mid-myocardial muscle surface is smooth, whereas the human endocardium is trabeculated, which often hampers catheter stability. This in vitro setting was chosen to easily control electrode orientation and CF, and it can be regarded as a proofofconceptforfutureinvivoexperiments. The catheter tip was held parallel to the myocardial surface in this study; no data were collected with the catheter in perpendicular contact. Data from the literature on this issue are controversial: some authors obtained larger lesions by means of parallel contact (8 10), whereas others suggested that catheter orientation does not play a role in determining lesion size (11). The parallel orientation in our study was derived from the observation that in clinical practice, most lesions are created with such orientation. During RF ablation for right atrial flutter (12) and atrial fibrillation ablation (13), theablationcatheter tip is mostly held parallel to the myocardial surface. Lesions were measured by a nonblinded observer, thus introducing a possible expectancy bias. In similar studies, other authors (1,3) have reported not only lesion width and depth (2,14) but also lesion volume; lesion volume is derived from width and depth measurements according to the formula for an oblate ellipsoid and may prove less accurate than width and depth,whichcan,bycontrast,bedirectlymeasured. Moreover, when RF ablation is performed in clinical practice, lesion width and depth are more relevant indexes than lesion volume in terms of achieving success (e.g., lesion transmurality and continuity). Another point is that the average impedance measured in our study (65 U) differs significantly from the typical values recorded during RF ablation in humans (approximately 110 U). Moreover, the presence in our experimental setup of saline bath at room temperature instead of heparinized blood at 37 C may have introduced further discrepancies from a clinical setting. Lastly, in in vivo settings, stable, pre-specified power levels may not be easily achieved because of catheter instability, ablation site anatomy (e.g., pouches), and variable flow velocity of the surrounding blood. The main scope of our study, however, was to achieve proof of principle of the predictive power of LSI in predicting RF lesion dimensions if compared with other indexes (e.g., FTI, CF) and not to determine absolute LSI values to translate as they are in the clinical practice. Our results therefore need to be confirmed prospectively in in vivo studies. CONCLUSIONS LSI was found to be highly predictive of RF lesion width and depth in the in vitro model. At similar LSI values, lesions obtained by using lower power settings were similar in magnitude, but exhibited a superior safety profile (no steam pops), compared with lesions obtained by means of highpower settings. Further studies are warranted to explore the predictive value of parameters provided by CF catheters, including LSI, in in vivo and human settings. ACKNOWLEDGEMENT The authors are grateful to Franco Noventa (Senior Scientist, Department of Molecular Medicine, University of Padua, Padua, Italy) for the statistical analysis. ADDRESS FOR CORRESPONDENCE: Dr. Luca De Mattia, Arrhythmia and EP Unit, Cardiology Department, Cà Foncello Hospital, Piazzale Ospedale n 1, 31100 Treviso, Italy. E-mail: dmluca.it@libero.it.

OCTOBER 2017:1126 35 Calzolari et al. Lesion Size Index to Predict In Vitro RF Lesion Size 1135 PERSPECTIVES COMPETENCY IN MEDICAL KNOWLEDGE: RF catheter ablation is a well-established therapy for several cardiac arrhythmias. Proper RF delivery is crucial both to obtain an effective tissue lesion and to avoid excessive tissue heating, steam pop formation, and cardiac perforation. Traditionally, parameters such as RF power, catheter tip temperature, and impedance are monitored during RF delivery. However, these parameters display limited accuracy in assessing both the effectiveness and safety of the procedure, and more reliable lesion quality markers are needed. TRANSLATIONAL OUTLOOK: Our results showed that LSI is the best in vitro predictor of RF lesion width and depth compared with power, CF, RF time, and FTI. If confirmed in in vivo and human studies, LSI would result in a useful guide for delivering a safer and more effective RF ablation therapy. REFERENCES 1. Yokoyama K, Nakagawa H, Shah DC, et al. Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus. Circ Arrhythmia Electrophysiol 2008;1:354 62. 2. Thiagalingam A, D Avila A, Foley L, et al. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol 2010;21:806 11. 3. Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol 2010;21:1038 43. 4. Ikeda A, Nakagawa H, Lambert H, et al. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart. Circ Arrhythm Electrophysiol 2014;7:1174 80. 5. Kautzner J, Neuzil P, Lambert H, et al. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation. Europace 2015;17:1229 35. 6. Lambert H, Olstad SJ, Fremont OB. Prediction of atrial wall electrical reconnection based on contact force measured during RF ablation. United States Patent Application Publication. Pub. No. US 2012/0209260 A1. Publication Date August 16, 2012. 7. Haines DE. Biophysics of radiofrequency lesion formation. In: Huang SKS, Wood MA, editors. Catheter Ablation of Cardiac Arrhythmias. 2nd ed. Philadelphia, PA: Saunders, Elsevier Inc., 2011: 2 19. 8. Chugh S, Chan RC, Johnson SB, Packer DL. Catheter tip orientation affects radiofrequency ablation size in the canine left ventricle. Pacing Clin Electrophysiol 1999;22: 413 20. 9. Nakagawa H, Wittkampf FH, Yamanashi WS, et al. Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. Circulation 1998; 98:458 65. 10. Otomo K, Yamanashi WS, Tondo C, et al. Effects of increase in electrode cooling and electrode-tissue interface area. J Cardiovasc Electrophysiol 1998;9:47 54. 11. Everett TH, Lee KW, Wilson EE, Guerra JM, Varosy PD, Olgin JE. Safety profiles and lesion size of different radiofrequency ablation technologies: a comparison of large tip, open and closed irrigation catheters. J Cardiovasc Electrophysiol 2009; 20:325 35. 12. Wittkampf FH, Nakagwa H. RF catheter ablation: lessons on lesions. Pacing Clin Electrophysiol 2006;29:1285 97. 13. Knecht S, Reichlin T, Pavlovic N, et al. Contact force and impedance decrease during ablation depends on catheter location and orientation: insights from pulmonary vein isolation using a contact force-sensing catheter. J Interv Card Electrophysiol 2015;43:297 306. 14. Weiss C, Antz M, Eick O, Eshagzaiy K, Meinertz T, Willems S. Radiofrequency catheter ablation using cooled electrodes: impact of irrigation flow rate and catheter contact pressure on lesion dimensions. Pacing Clin Electrophysiol 2002;25 4 Pt 1:463 9. KEY WORDS ablation complications, ablation lesion dimensions, contact force catheter, lesion size index, radiofrequency ablation