The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

Similar documents
December 2016, Volume: 8, Issue: 12, Pages: , DOI:

Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract

Effect of femtosecond and microkeratome flaps creation on the cornea biomechanics during laser

Description of iatrogenic corneal ectasia in patients without traditional risk factors

LASIK Flap Thickness Accuracy after Using Mechanical Microkeratome

Evaluation of The Accuracy of Sub Bowman s Keratomileusis (SBK) Microkeratome in Flap Creation during Lasik Surgery

Management of Unpredictable Post-PRK Corneal Ectasia with Intacs Implantation

Corneal Hysteresis, Resistance Factor, Topography, and Pachymetry After Corneal Lamellar Flap

Sheldon Herzig MD, FRCSC Herzig Eye Institute Toronto, Ontario

펨토초레이저와미세각막절삭기를이용한근시교정수술에서임상성적비교

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

A procedure for Present and Future

Jing Zhao 1, Peijun Yao 1, Meiyan Li 1, Zhi Chen 1, Yang Shen 1, Zhennan Zhao 1, Zimei Zhou 2, Xingtao Zhou 1 * Abstract.

Clinical experience of 9,000 small aperture Inlays for presbyopia correction

LASIK has been the primary type of corneal refractive surgery

Recent concerns regarding the depth of tissue ablation with

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy

Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer

Nature and Science 2017;15(11) Mohamed Elmoddather. MD

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery

Original Article High myopia as a risk factor for post-lasik ectasia: a case report

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

One-year outcomes of small-incision lenticule extraction (SMILE): mild to moderate myopia vs. high myopia

Abdel Rahman ElSebaey, MD, PhD.

Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction

LASIK for 6.00 to D of Myopia With up to 3.00 D of Cylinder Using the ALLEGRETTO WAVE: 3- and 6-month Results With the 200- and 400-Hz Platforms

The pinnacle of refractive performance.

BJO Online First, published on November 4, 2009 as /bjo

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

One-year outcomes of a bilateral randomised prospective clinical trial comparing PRK with mitomycin C and LASIK

For approximately two decades photorefractive keratectomy. Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK.

Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by

NIH Public Access Author Manuscript Cornea. Author manuscript; available in PMC 2014 May 29.

Contoura TM Vision Correction

Effects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis

Simultaneous Topography-guided Surface Ablation with Collagen Cross-linking for Keratoconus

Wavefront-optimized Versus Wavefrontguided LASIK for Myopic Astigmatism With the ALLEGRETTO WAVE: Three-month Results of a Prospective FDA Trial

Summary Recommendations for Keratorefractive Laser Surgery June 2013

Retrospective Testing of the Score for the Detection of Ectasia Susceptibility: A Case Report of Ectasia 7 Years after LASIK

In Practice. Surgical Procedures Diagnosis New Drugs

Comparison of Corneal Shape Changes and Aberrations Induced By FS-LASIK and SMILE for Myopia

Analysis of eye movements during myopic laser in situ keratomileusis

Laser in situ keratomileusis (LASIK) has proven to be

Efficacy of Photorefractive Keratectomy for Military Pilot Recruitment in an Asian Air Force

Outcomes of NIDEK Optical Path Difference Custom Ablation Treatments (OPDCAT) for Myopia With or Without Astigmatism

Corneal Changes Following LASIK and Enhancement with Microkeratome and Femtosecond Laser Flaps

Introduction. Anders Vestergaard, 1,2 Anders Ivarsen, 1 Sven Asp 1 and Jesper Ø. Hjortdal 1. Acta Ophthalmologica 2013

Cataract Surgery in the Patient with a History of LASIK or PRK

Author s Affiliation. Original Article. Visual outcomes after LASIK (laser-assisted in-situ keratomileusis) for various refractive errors.

Post-LASIK Ectasia associated with Pigmentary Glaucoma: Tomographic and Biomechanical Characterization

CLINICAL SCIENCES. Management of Post-LASIK Corneal Ectasia With Intacs Inserts

The two currently accepted methods for correcting

Sub-Bowman keratomileusis (SBK) is a type of LASIK

ONE THOUSAND WAVEFRONT GIDED TREATMENT ON MICROSCAN VISUM. Mickael Yablokov. I have no any financial interests in any products mentioned in this paper

Wavefront-Optimized Technology in Hyperopic Correction Stability Using Different Optical Zones

Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series

Femtosecond Lasers for LASIK Flap Creation

Keratoconus Clinic. Optometric Co-management Opportunities

VisuMax from ZEISS Defining the pulse rate in refractive surgery

Sensations of Chinese Ametropia Patients under Laser-Assisted Keratomileusis Surgical Techniques

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

Refractive and Keratometric Stability in High Myopic LASIK With High-Frequency Femtosecond and Excimer Lasers

Abstracts. Edited by Dr. Tahir Mahmood. Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation Single-surgeon series

Refractive Surgery Dilemma

Assessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction. Mohamed Tarek El-Naggar, Dikran Gilbert Hovaghimian

Wenjing Wu and Yan Wang. 1. Introduction. 2. Materials and Methods

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis

Research Article Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4mm versus 1.

2/7/18. Disclosures: Laser K s: Keratectomy to Keratomileusis with a SMILE. Who Patients Are Listening to

Comparison of Corneal Thickness with Online Optical Coherence Pachymetry and Ultrasound Pachymeter

Original Article Comparison of different femtosecond laser refractive surgeries on higher-order aberrations

Laser-assisted in situ keratomileusis (LASIK) has emerged as. In Vivo Real-Time Intraocular Pressure Variations during LASIK Flap Creation.

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

Four-year Postoperative Results of the US ALLEGRETTO WAVE Clinical Trial for the Treatment of Hyperopia

Thirty-month results after the treatment of post-lasik ectasia with allogenic lenticule addition and corneal cross-linking: a case report

LASIK Surgery. One Use-Plus. The Moria Option for SBK

pre-laser cut pre-laser cut Pre-operative Known and Potential Complications of SMILE Failure to obtain an adequate suction

Ocular Jeopardy Marc R. Bloomenstein OD, FAAO

In recent years, more and more studies have focused on. Characteristics of Straylight in Normal Young Myopic Eyes and Changes before and after LASIK

Intraocular pressure changes and relationship. Corneal Biomechanics After SMILE and FS-LASIK

POST-LASIK ECTASIA MANAGEMENT

IntraLASIK Correction Of Nearsightedness, Farsightedness and Astigmatism Using IntraLase TM Technology

Policy #: 354 Latest Review Date: July 2011

Satisfaction of 13,655 Patients With Laser Vision Correction at 1 Month After Surgery

Grand Rounds CASE CONSULTATION. Edited by Alfredo Castillo, MD & Jaime Aramberri, MD

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

Pearls for the Refractive Technician Fadiah Alkhawaldeh, IMBA, COT, ROUB

US Trends in Refractive Surgery: The 2008 ISRS/AAO Survey

Journal of Ophthalmology & Clinical Research

Management of postkeratoplasty ametropia: IntraLASIK after penetrating keratoplasty

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Central Corneal Thickness and its Association with Ocular Parameters

Clinical Study Posterior Corneal Surface Stability after Femtosecond Laser-Assisted Keratomileusis

Photorefractive Keratectomy as A Retreatment of Residual Myopia after Previous Laser in Situ Keratomileusis

L. Spadea, R. Ferrante, F. Romani, A. Di Gregorio

Transcription:

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page 7574-7579 Biomechanical Corneal Changes Post LASIK with Mechanical Microkeratome Flap versus Femtosecond Flap Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Assuit ABSTRACT Back ground: The biomechanical impact of flap creation may be important in explaining changes in the curvature of the residual stroma after flap creation which plays a critical role in the development of ectasia. OBJECTIVE: To evaluate the impact of the creation of corneal flaps with mechanical microkeratome versus femtosecond laser on the biomechanical properties of the corneas. METHOD: This study included 100 eyes of 50 patients (Microkeratome ) Compared with 100 eyes of 52 patients (Femtosecond ) with myopia with or without astigmatism. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with Ocular Response Analyzer before and1, 3,6and 12 months after surgery. We also investigated the relationship between these biomechanical changes and the amount of myopic correction. RESULTS: Corneal resistance factor and hysteresis was changed significantly after flap creation in both groups. In Moria2 group, they decreased significantly from 11.55 ± 1.29 mm Hg and 11.68±1.40 mm Hg to 9.47 ± 1.29 mm Hg and 8.49 ± 1.54 mm Hg, respectively) (P <.0001). In femtosecond group, they decreased from11.51 ± 1.25 mm Hg and 11.66±1.41 mm Hg to 9.49 ± 1.30 mm Hg and 8.5 ± 1.53 mm Hg, respectively (P <.0001). The ablation depth (P=0.650), residual corneal thickness (P=0.442), and postoperative corneal curvature (P=0.354) were not significantly different between femtosecond group and Moria2 group after surgery. CONCLUSION: Both femtosecond LASIK and Moria2 LASIK can affect the biomechanical strength of the cornea depending on the amount of myopic correction. The amount of biomechanical changes is larger after LASIK with mechanical microkeratome than after femtosecond from a biomechanical viewpoint. Keywords: LASIK, Femtosecond, Microkeratome, Flaps. INTRODUCTION Refractive surgery alters the biomechanical properties of the cornea, which may play an important role in affecting treatment outcome in terms of postsurgical complications (1,2). Advances in techniques and instruments have reduced the incidence and severity of flap abnormalities and other potentially severe complications (3). During LASIK, an immediate near-circumferential severing of corneal lamellae results in a redistribution of stress and unprogrammed biomechanical shape changes (4,5). Although some changes in the shape of the residual stroma during and after surgery may be precursors of an ectatic condition, others may represent non-progressive changes associated with the establishment of a new postoperative structural state (6). The biomechanical impact of flap creation on the residual stroma likely plays a critical role in the development of ectasia. Biomechanical effects may also be important in explaining changes in the curvature of the residual stroma after flap creation and photoablation that do not represent ectasia but nonetheless affect refractive outcome. It is known that flap thickness can vary significantly with Received: 28/8/2018 Accepted: 18/9/2018 7574 some mechanical microkeratomes, with standard deviations of 30 µm having been reported depending on the microkeratome used (7). The predictability of this process has a potential for compromising corneal stability in the long term as thicker flaps could more significantly modify the biomechanical integrity of the cornea (8). In this study, we used the femtosecond laser to create flaps at same depths of microkeratome Moria2 and measured the impact of programmed flap thickness on the biomechanical properties of the underlying residual stroma. PATIENTS AND METHODS This study included 100 eyes of 50 patients (Moria2 ) Compared with 100 eyes of 52 patients (Femtosecond ) with myopia with or without astigmatism. Inclusion criteria were no symptoms or signs of dry eye before LASIK, no previous eye surgery, no topical ocular medications before surgery, and no other ocular conditions, such as ocular rosacea or chronic blepharitis. The preoperative evaluation consisted of a complete ophthalmic examination comprising uncorrected distance visual acuity (UDVA),

corrected distance visual acuity (CDVA), manifest and cycloplegic refractions, topographic analysis, wavefront analysis, fundus examination, Goldman applanation tonometry, ultrasound pachymetry, and slitlamp biomi-croscopy. The Ocular Response Analyzer was used to measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc). OCT optical coherence tomography (Visante OCT; Carl Zeiss Meditec, Jena, Germany) to measure corneal pachymetry and flap thickness; and surface wave velocity to estimate corneal stiffness before and 3 months after LASIK. Surgical Procedure After instillation of topical anesthetic and a sterile preparation of the lids. In femtosecond group the flaps were created with a ifs 150 IntraLase (Abbott Medical Optics Inc., Santa Ana, California) Femtosecond flap settings were a diameter of 9.0 and a standard 55-degree hinge and 70-degree side-cut angle. The lamellar cut and side cuts were performed with an energy of.9 mj with the ifs150 laser. The attempted flap thickness was 110 mm The hinges in all eyes were superior. In microkeratome group the flaps were created with mechanical microkeratome the Moria2 microkeratome with plastic head use 110head to Table (1) Demographic data and preoperative characteristics. create 8.5-9.0 mm corneal flaps with superior hinge. Stromal tissue ablation was performed with the Visx Star S4 IR (Abbott Medical Optics, Inc.) for both groups. Eyes were treated with moxifloxacin hydrochloride ophthalmic solution 0.5% and prednisolone acetate 1% ophthalmic suspension USP 4 times daily for 1 week. In addition, nonpreserved artificial tears (Systane or Refresh Plus) were used 4 to 8 times a day for 1month as needed. Scheduled postoperative follow-up visits were at 1 day, 1 week, and 1, 3, and 6 months. Data were expressed as mean ± standard deviation (SD) and analyzed with SPSS 17.0 software (SPSS Inc, Chicago, Illinois, USA). For independent-samples t-test was used to compare the mean values of each parameter between the two groups. Multiple linear step wise regression was used to evaluate influencing factors of corneal biomechanics. P<0.05 was considered statistically significant. RESULTS There were no statistically significant differences between the femtosecond group and the microkeratome group in age, sex distribution, or central corneal thickness. The following table (1) showed the patients demographic data and preoperative characteristics (Table 1). Femtosecond Microkeratome P Characteristic (n = 100) (n = 100) Value Age (y) Mean 44 45.8 Range 20-52 20-53 Female 55% 53%.9 Male 45% 47% Mean CCT± SD 529 ± 30 531± 34.6 Mean SE SD -4.55 D -3.87 D.04 CCT = central corneal thickness SE= spherical equivalent; Table (1): showed the patients demographic data and preoperative characteristics. There were no statistically significant differences between the femtosecond group and the microkeratome group in age, sex distribution, or central corneal thickness. Mean flap thicknesses ±SD were 128.8±13.5 µm for microkeratome group and 115.5±5.9 in femtosecond group (p<0.001). Corneal pachymetry did not show statistical difference between the groups Therefore, flaps for femtosecond group and microkeratome group represented 12.8% and 21.6% of the total pachymetry respectively. 7575

Biomechanical Corneal Changes Post LASIK with Mechanical Microkeratome Table (2): Ablation depth, residual corneal thickness, corneal flap thickness and Residual stromal bed thickness. Moria2 Femtoescond P Ablation depth (µm) 73.8±22.9 73.5±20.3 0.690 Residual corneal thickness (µm) 462.4±21.5 469.6±32.8 0.450 Corneal flap thickness (µm) 128.8±13.5 115.9±5.9 <0.01 Residual stromal bed thickness (µm) 338.5±26.2 365.7±24.8 <0.01 Table (2): showed ablation depth, residual corneal thickness, corneal flap thickness and Residual stromal bed thickness in both groups. The corneal flap thickness was significantly decreased in the femtosecond group, while the residual bed thickness was greater in moria 2group. In microkeratome group the preoperative mean± SD of corneal hysteresis was (11.55 ± 1.29 mm Hg and mean± SD corneal resistant factor was 11.68±1.40 mm Hg were significantly higher than postoperative values (9.47 ± 1.29 mm Hg and 8.49 ± 1.54 mm Hg, respectively) (P <.0001). A higher attempted correction was correlated with a larger delta corneal Hysteresis and Delta Corneal resistant factor was (AD, r = 0.48 and r = 0.67, respectively; delta MRSE, r = 0.53 and r = 0.67, Table (3): Preoperative and postoperative biomechanical parameters. Moria2 respectively). No correlation was found between delta corneal hysteresis, delta corneal resistant factor was, and preoperative CCT. In femtosecond group the preoperative mean± SD of corneal hysteresis was11.51 ± 1.25 mm Hg and mean± SD corneal resistant factor was 11.66±1.41 mm Hg were significantly higher than postoperative values (9.49 ± 1.30 mm Hg and 8.5 ± 1.53 mm Hg, respectively) (P <.0001). A higher attempted correction was correlated with a larger delta corneal hysteresis and delta corneal resistant factor was (AD, r = 0.48 and r = 0.67, respectively; delta MRSE, r = 0.53 and r = 0.67, respectively). No correlation was found between delta corneal hysteresis, delta corneal resistant factor was, and preoperative CCT as shown in table (3) Femtosecond Preoperative Corneal resistance factor CRF 11.68±1.40 11.66±1.41 0.097 Corneal hysteresis CH 11.55 ± 1.29 11.51 ± 1.25 0.218 Postoperative Corneal resistance factor CRF 8.49 ± 1.54 8.5 ± 1.53 0.097 Corneal hysteresis CH 9.47 ± 1.29 9.49 ± 1.30 0.218 Simulated keratometry was comparable between the groups (p = 0.41). Simulated keratometry values changed in the microkeratome group (from 44.11±1.3 D to 40.3±1.1 D, p = 0.003after flap creation) as shown in figure (1) and in femtosecond group (from 44.4±1.2 to D 42.6±0.9 D to, p = 0.55). P Figure (1): SimK of preoperative and 12 months after lasik in microkeratome group. Preoperatively, Corneal Hysteresis and Corneal resistant factor showed similar results between the groups (p = 0.05), but postoperatively was statistically different with higher values for the microkeratome group (, p = 0.01) as shown in Figure (2). 7576

Figure. (2): Relationship between CRF and Ch in both groups. Preoperative and postoperative flap creation IOPg and IOPcc did not present a statistical difference between both groups. Postoperative flap creation IOPg and IOPcc did not present a statistical difference compared with preoperative values for both groups. Figure (3) showed relationship between IOPg, IOPcc and CH. Figure (3): Relationship between IOPg, IOPcc and CH in both groups. DISCUSSION The biomechanical impact of flap thickness on CH and CRF may be important in better understanding the pathophysiology of ectasia, one of the most vision-threatening complications encountered after refractive surgery. CH is thought to be a measure of viscous damping in the corneal tissue, or the energy absorption capability of the cornea, whereas CRF is a measure of the combined viscous damping and elastic resistance behaviors of the cornea (9-10). LASIK is the mainstream surgery to correct the refraction errors nowadays, which is proved to be safe, effective and well predicable. The critical step of LASIK is to make a thin and uniform lamellar cornea flap (11). Femtosecond laser flaps showed uniform thickness and planar-shape, however some microkeratome created flaps, which were not uniform but meniscus-shaped. The flaps made by femtosecond laser were proved to be more precise, more even, and better predictable than the flaps made by microkeratome (12-13). After 12 months follow-up, CH or CRF were significantly different between the two groups. The femtosecond group provided thinner corneal flaps compared to the Moria 2 group. Therefore better performance of corneal biomechanics was gained in the femtosecond group. Based on the studies of Franco and Lira (14) and Kamiya et al. (15), sufficient Residual corneal thickness (RCT) was the guarantee of the post-operational corneal biomechanics. This outcome indicated that with the premise of the same RCT, the different way of flap formation had notable influence on the cornea biomechanical parameters including CRF and CH one year after surgery. This study was coincided with the previous two researches. In this study there was significant decrease of CRF from 6 to 12months in the Moria 2 group. This outcome meant that femtosecond group had better long-term effect on cornea biomechanics than the Moria 2 group. Although iatrogenic post-lasik ectasia is reported in the patients whose residual 7577

Biomechanical Corneal Changes Post LASIK with Mechanical Microkeratome cornea were less than 250 µm, reserving enough RCT was still the most important way to avoid post-lasik ectasia (16-17). Furthermore, the greater inflammatory response and biomechanical stability of the femtosecond flap was reported by Dawson et al. (18) and Netto et al. (19) and proved by Kim et al. (20) that femtosecond flaps were more strong and unlikely to shift or have a crease. There was growing evidence that it was different in the wound-healing response and biomechanical effects on the cornea depending on whether a flap was created by a microkeratome or femtosecond laser (18,20). It is noticeable that CRF and CH value increased with the increasing of CCT and the curvature of the cornea, while CH value decreased with the increasing of IOPcc. Cornea thickness was the main effective factor of cornea biomechanics. We found that cornea curvature had some influence on the CH value, which was proved by Lim et al. (21). The relationship between the cornea curvature and the biomechanical parameters indicated that cornea with high refractive power might need more strength to gain applanation. Therefore the IOP would be higher than actual. Hence, when the myopic eyes were taken the IOP test, not only the cornea thickness but also the cornea curvature should be taken into account. Also in current study we found that CRF increased with the increasing of RCT, pre-lasik CRF and RSBT, while CH increased with the increasing of RCT or pre-lasik CRF and decreased with the increasing of pre-lasik IOP or CFT. This result indicated that post-lasik cornea biomechanical parameters (CRF and CH) correlate not only with the RCT but also with the inherited physical and physiological characters of the operated eyes. The femtosecond group got better corneal biomechanical performance one year after surgery than the Moria 2 group in this study. The femtosecond laser provide thinner and better cornea flaps. Thicker flaps induced a steepening that might be related to the more pronounced structural effect of a deeper lamellar insult. Thin flaps caused less acute changes in corneal shape and biomechanical properties and might, in general, be less prone to unexpectedly affecting postoperative refractive outcome or contributing to the generation or exacerbation of ectasia (22). Femtosecond laser is able to create a customized corneal flap of between 90 and 110 µm with a diameter based on the requirements of the individual patient and the type of excimer laser with high precision, thus saving corneal tissue. The diameter could be precisely controlled by the surgeon (23) and is not dependent on corneal anatomy. Moreover, the decrease in hysteresis seems to be more predictable after LASIK with the femtosecond laser compared with a mechanical microkeratome (24). CONCLUSION Both femtosecond LASIK and Moria2 LASIK can affect the biomechanical strength of the cornea depending on the amount of myopic correction. The amount of biomechanical changes is larger after LASIK with mechanical microkeratome than after femtosecond from a biomechanical viewpoint. REFERENCES 1. Dupps WJ, Wilson SE (2006): Biomechanics and wound healing in the cornea. Exp Eye Res., 8:709 20. 2. Rabinowitz YS (2006): Ectasia after laser in situ keratomileusis. Curr Opin Ophthalmol., 17:421 6. 10. 3. Binder PS (2007): Analysis of ectasia after laser in situ keratomileusis: risk factors. J Cataract Refract Surg., 33:1530 8. 4. Roberts C (2000): The cornea is not a piece of plastic (editorial) J Refract Surg., 16:407 13. 5. Ortiz D, Piñero D, Shabayek MH, Arnalich- Montiel F, Alió JL (2007): Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg., 33(8):1371 1375. 6. Luce D (2006): Methodology for cornea compensated IOP and corneal resistance factor for Reichert ocular response analyzer. ARVO abstract Invest Ophthalmol Vis Sci., 17 (11):2266. 7. von Jagow B, Kohnen T (2009): Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography. J Cataract Refract Surg., 35(1):35 41. 8. Montés-Micó R, Rodríguez-Galietero A, Alió JL (2007): Femtosecond laser versus mechanical keratome LASIK for myopia. Ophthalmology, 114(1):62 68. 9. Luce DA (2005): Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg., 31:156 62. 10. Glass DH, Roberts CJ, Litsky AS, Weber PA (2008): A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. Invest Ophthalmol Vis Sci., 49:3919 26. 11. von Jagow B, Kohnen T (2009): Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment 7578

optical coherence tomography. J Cataract Refract Surg., 35(1):35 41. 12. Montés-Micó R, Rodríguez-Galietero A, Alió JL (2007): Femtosecond laser versus mechanical keratome LASIK for myopia. Ophthalmology, 114(1):62 68. 13. Montés-Micó R, Rodríguez-Galietero A, Alió JL, Cerviño A (2007): Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome. J Refract Surg., 23(2):188 192. 14. Franco S, Lira M (2009): Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature. Clin Exp Optom., 92(6):469 475. 15. Kamiya K, Shimizu K, Ohmoto F (2009): Time course of corneal biomechanical parameters after laser in situ keratomileusis. Ophthalmic Res., 42(3):167 171. 16. Tatar MG, Aylin Kantarci F, Yildirim A, Uslu H, Colak HN, Goker H, Gurler B (2014): Risk factors in post-lasik corneal ectasia. J Ophthalmol., 2014:204191. 17. Rabinowitz YS (2013): INTACS for keratoconus and ectasia after LASIK. Int Ophthalmol Clin., 53(1):27 39. 18. Dawson DG, Randleman JB, Grossniklaus HE, O'Brien TP, Dubovy SR, Schmack I, Stulting RD, Edelhauser HF (2008): Corneal ectasia after excimer laser keratorefractive surgery: histopathology, ultrastructure, and pathophysiology. Ophthalmology, 115(12):2181 2191.e1. 19. Netto MV, Mohan RR, Medeiros FW, Dupps WJ, Jr, Sinha S, Krueger RR, Stapleton WM, Rayborn M, Suto C, Wilson SE (2007): Femtosecond laser and microkeratome corneal flaps: comparison of stromal wound healing and inflammation. J Refract Surg., 23(7):667 676. 20. Kim JY, Kim MJ, Kim TI, Choi HJ, Pak JH, Tchah H (2006): A femtosecond laser creates a stronger flap than a mechanical microkeratome. Invest Ophthalmol Vis Sci., 47:599 604 21. Lim L, Gazzard G, Chan YH, Fong A, Kotecha A, Sim EL, Tan D, Tong L, Saw SM (2008): Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children. Invest Ophthalmol Vis Sci., 49 (9):3852 3857. 22. Slade SG (2008): Thin-flap laser-assisted in situ keratomileusis. Curr Opin Ophthalmol., 19:325 9. 23. Holzer MP, Rabsilber TM, Auffarth GU (2006): Femtosecond laser-assisted corneal flap cuts: morphology, accuracy, and histopathology. Invest Ophthalmol Vis Sci., 47:2828 31. 24. Hamilton DR, Johnson RD, Lee N, Bourla N (2008): Differences in the corneal biomechanical effects of surface ablation compared with laser in situ keratomileusis using a microkeratome or femtosecond laser. J Cataract Refract Surg., 34:2049 56. 7579