ACCESS hstni SCIENTIFIC LITERATURE

Similar documents
High-sensitivity cardiac troponin I immunoassay reduces the chance of patient misclassification in the emergency department

Table. Analytical characteristics of commercial and research cardiac troponin I and T assays declared by the manufacturer.

Troponin when is an assay high sensitive?

10 Ways to Make the Use of High Sensitivity Cardiac Troponin Values Easier and Better

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

Low concentrations of high-sensitivity troponin T at presentation to the

Abstract. Introduction. imedpub Journals

The state-of-the-art of high-sensitivity immunoassay for measuring cardiac troponin I and T

Impact of Troponin Performance on Patient Care

Use of Biomarkers for Detection of Acute Myocardial Infarction

Defining rise and fall of cardiac troponin values

DIAGNOSTICS ASSESSMENT PROGRAMME

The clinical performance of the novel POC Minicare ctni-assay. Per Venge, MD PhD Professor in Clinical Chemistry Uppsala University Uppsala, Sweden

High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation

Waiting for High-Sensitivity POCT Cardiac Troponin Assays: Clinical and Analytical Needs I Have a Pain in My Chest That Hurts Very Bad

7/31/2018. Overview of Next Generation Cardiac Troponin T High Sensitivity. Disclosures. Course Objectives: high sensitive Troponin T assay

High Sensitivity Troponins. IT S TIME TO SAVE LIVES. Updates from the ESC 2015 Guidelines November 17th 2016 OPL CONGRESS Dr.

hs-c Tn I high sensitivity troponin I <17 min

BioRemarkable Symposium

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

What can we learn from EQAs and audits for cardiac marker testing?

Mario Plebani University-Hospital of Padova, Italy

IFCC Task Force on Clinical Applications of Cardiac Biomarkers (TF-CB) Report to the General Conference 2016 Madrid

High Sensitivity Troponin Improves Management. But Not Yet

Cardiac Assessment Controls

Cardiac Troponin Testing and Chest Pain Patients: Exploring the Shades of Gray

Variability and Error in Cardiac Troponin Testing. An ACLPS Critical Review

Troponin Assessment. Does it Carry Clinical Message? Stefan Blankenberg. University Heart Center Hamburg

Predictive significance of detectable cardiac troponin I measured with a contemporary-sensitive assay in a real life experience

EDUCATIONAL COMMENTARY UNDERSTANDING THE BENEFITS AND CHALLENGES OF HIGH- SENSITIVITY TROPONIN TESTING IN CLINICAL AND PATHOLOGY SETTINGS

RESPONSES TO COMMENTS ON: Recommendations for Use of Point-of-Care (POC) Troponin Assays in Assessment of Acute Coronary Syndrome

Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a sensitive troponin I assay

Mario Cavazza Medicina d Urgenza e Pronto Soccorso Azienda Ospedaliero Universitaria di Bologna

High-Sensitive Troponin in the Evaluation of patients with Acute Coronary Syndrome (High-STEACS): a stepped-wedge cluster-randomised controlled trial

Validation of an accelerated high-sensitivity troponin T assay protocol in an Australian cohort with chest pain

Congreso Nacional del Laboratorio Clínico 2016

Är dagens troponinmetoder tillräckligt känsliga?

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

Chapter 2. High-sensitivity C-reactive protein methods examined

Diagnostics consultation document

Bertil Lindahl Akademiska sjukhuset Uppsala

High-Sensitivity Cardiac Troponin in Suspected ACS

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

EDUCATIONAL COMMENTARY CARDIAC FUNCTION: BIOCHEMICAL MARKERS UPDATE

Analytical performance of the i-stat cardiac troponin I assay

Cardiac Troponin: Current Status and Future Promise

Dolore Toracico e Livelli di Troponina non Misurabili

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

Diagnostics guidance Published: 1 October 2014 nice.org.uk/guidance/dg15

The Clinical Laboratory Working with Physicians to Improve Patient Care

ORIGINAL ARTICLE Determination of the 99th percentile upper reference limit for highsensitivity cardiac troponin I in Malaysian population

Undetectable High Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial Infarction

Challenging Issues in Cardiac Biomarker interpretation. F. Nikaeen. MD interventional Cardiologist

About OMICS International

CLINICAL GUIDANCE FRAMEWORKS

PERIOSTIN ELISA CONTENTS

Undetectable High Sensitivity Cardiac Troponin T Level in the Emergency Department and Risk of Myocardial Infarction

Supplementary Online Content

Article in press - uncorrected proof

Does serial troponin measurement help identify acute ischemia/ischemic events?

CARDIOLOGY GRAND ROUNDS

9/18/2017. Disclosures. Cardiac Troponin: ER Utilization and the Next Generation

SCIEX Vitamin D 200M Assay for the Topaz System

New diagnostic markers for acute coronary syndromes

Keywords: albuminuria; albumin/creatinine ratio (ACR); measurements. Introduction

Quantitative measurement of 6 analytes in parallel hs Trop I, NTproBNP, D-Dimer, hscrp, Myoglobin, HCG, CK-MB mass

Keywords Acute coronary syndromes, High sensitivity cardiac markers, Malta, Troponin T, Myocardial infarction

Hit the road Jack! W. FRANK PEACOCK, MD, FACEP, FACC

Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation

BNP Fragment EIA (Cat.No. BI-20852W) For the Determination of BNP Fragment in Human Samples

Better, higher, lower, faster: increasingly rapid clinical decision making using high-sensitivity cardiac troponin assays

Cardiac Assessment Controls A critical element of reliable cardiac testing

Multiple studies are available concerning the use of

Clinical Application of Cardiac Biomarkers in an Accredited Chest Pain Center Laboratory s Best Practices

Speaker: Richard Heitsman, MICT, C-POC-AACC. Title: National Account Manager/Clinical Cardiac Specialist-Radiometer America.

Clinical Considerations of High Sensitivity Troponins

QMS TACROLIMUS APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800

Cardiac Troponin Assays: Guide to Understanding Analytical Characteristics and Their Impact on Clinical Care

Quantitative Measurement of Emergency Biomarkers in Parallel

LIPASE liquicolor. Design Verification. Multipurpose Reagent

Setting The setting was secondary care. The economic study was carried out in Hong Kong.

Serial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial Infarction JAMA. 2011;306(24):

EARLY DIAGNOSIS AND RISK STRATIFICATION IN PATIENTS WITH SYMPTOMS SUGGESTIVE OF ACUTE CORONARY SYNDROME

HIGH SENSITIVITY TROPONIN - ITS USE IN DIAGNOSIS OF CARDIAC DYSFUNCTION

The PATH to better cardiac care starts here

Troponin I elevation increases the risk of death and stroke in patients with atrial fibrillation a RE-LY substudy. Ziad Hijazi, MD

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey

Paul Jülicher, 1 Jaimi H Greenslade, 2 William A Parsonage, 3 Louise Cullen 2. Open Access. Research

Cardiac Bio-Marker Testing in Acute Coronary Syndromes

Quantitative Measurement of Cardiac Biomarkers

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

High-sensitivity cardiac troponin testing in routine practice: economic and organizational advantages

Evaluation of the analytical performances of six measurands for thyroid functions of Mindray CL-2000i system

Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis

Recent community campaigns on

Statistical Considerations: Study Designs and Challenges in the Development and Validation of Cancer Biomarkers

Comparison of ARCHITECT chemiluminiscent microparticle immunoassay for determination of Troponin I in serum with AXYM MEIA technology

Rapid rule out of acute myocardial infarction: novel biomarker-based strategies

Improving the detection of myocardial infarction in women

Access AccuTnI+3 Troponin I

Transcription:

ACCESS hstni SCIENTIFIC LITERATURE 2017 2018

Table of contents Performance Evaluation of Access hstni A critical evaluation of the Beckman Coulter Access hstni: Analytical performance, reference interval and concordance...3 Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay... 4 Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin...5 Access hstni Method Comparisons Analytical comparison of three different versions of a high-sensitivity cardiac troponin I assay over ten years...7 Macrocomplexes and discordant high-sensitivity cardiac troponin concentrations...8 Assessing matrix, interferences and comparability between the Abbott Diagnostics and the Beckman Coulter high-sensitivity cardiac troponin I assays... 9 Access hstni in Clinical Practice High-sensitivity cardiac troponin I immunoassay reduces the chance of patient misclassification in the emergency department... 11 Diagnostic accuracy of a new high-sensitivity troponin I assay and five accelerated diagnostic pathways for ruling out acute myocardial infarction and acute coronary syndrome... 12 Evaluating rapid rule-out of acute myocardial infarction by use of a high-sensitivity cardiac troponin I assay at presentation... 13 2

PERFORMANCE EVALUATION OF ACCESS hstni A critical evaluation of the Beckman Coulter Access hstni: analytical performance, reference interval and concordance Pretorius CJ, Tate JR, et al. Clin Biochem 2018 March. [Epub ahead of print]. Background: We investigated the analytical performance, outlier rate, carryover and reference interval of the Beckman Coulter Access hstni in detail and compared it with historical and other commercial assays. Methods: We compared the imprecision, detection capability, analytical sensitivity, outlier rate and carryover against two previous Access AccuTnI assay versions. We established the reference interval with stored samples from a previous study and compared the concordances and variances with the Access AccuTnI+3 as well as with two commercial assays. Results: The Access hstni had excellent analytical sensitivity with the calibration slope 5.6 times steeper than the Access AccuTnI+3. The detection capability was markedly improved with the SD of the blank 0.18 0.20 ng/l, limit of blank (LoB) 0.29 0.33 ng/l and limit of detection (LoD) 0.58 0.69 ng/l. All the referenceinterval samples had a result above the LoB value. At a mean concentration of 2.83 ng/l the SD was 0.28 ng/l (CV 9.8%). Carryover (0.005%) and outlier (0.046%) rates were similar to the Access AccuTnI+3. The combined male and female 99th percentile reference interval was 18.2 ng/l (90% CI 13.2 21.1 ng/l). Concordance amongst the assays was poor with 16.7%, 19.6% and 15.2% of samples identified by all four assays as above the 99th, 97.5th and 95th percentiles. Analytical imprecision was a minor contributor to the observed variances between assays. Conclusions: The Beckman Coulter Access hstni assay has excellent analytical sensitivity and precision characteristics close to zero. This allows cardiac troponin I (ctni) measurement in all healthy individuals and the capability to identify numerically small differences between serial samples as statistically significant. Concordance in healthy individuals remains poor amongst assays. PERFORMANCE EVALUATION OF ACCESS hstni 3

PERFORMANCE EVALUATION OF ACCESS hstni Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay Lippi G, Ferrari A, et al. Clin Chem Lab Med 2017; 27;56(1):157 161. Background: This study was aimed to evaluate the analytical performance of the novel chemiluminescent and fully automated Beckman Coulter Access hstni highsensitivity immunoassay for measurement of cardiac troponin I (ctni). Methods: The study, using lithium heparin samples, included assessment of limit of blank (LOB), limit of detection (LOD), functional sensitivity, linearity, imprecision (within run, between-run and total) and calculation of 99th percentile upper reference limit (URL) in 175 healthy blood donors (mean age, 36±12 years; 47% women) and comparison with two other commercial ctni immunoassays. Results: The LOB, LOD and functional sensitivity of Access hstni were 0.14, 0.34 and 1.35 ng/l, respectively. The within-run, between-run and total imprecision was 2.2% 2.9%, 4.6% 5.4%, and 5.4% 6.1%, respectively. The linearity was excellent in the range of ctni values between 0.95 and 4195 ng/l (r=1.00). The 99th percentile URL was 15.8 ng/l. Measurable ctni values were found in 173/175 healthy subjects (98.9%). Good agreement of ctni values was found with AccuTnI+3 (r=0.97; mean bias, -9.3%), whereas less satisfactory agreement was found with Siemens Dimension Vista ctni (r=0.95; mean bias -55%). Conclusions: The results of our evaluation of the Beckman Coulter Access hstni indicate that the analytical performance of this fully automated immunoassay is excellent. 4 PERFORMANCE EVALUATION OF ACCESS hstni

PERFORMANCE EVALUATION OF ACCESS hstni Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I Masotti S, Prontera C, et al. Clin Chem Lab Med 2018. 23; 56(3):492 501. Background: The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (ctni) called Access hstni using the DxI platform, with the Access AccuTnI+3 method and the high-sensitivity (hs) ctni method for the ARCHITECT platform. Methods: The limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of the analytical performance and the comparison of ctni results, heparinized plasma samples were collected from healthy subjects, patients with cardiac diseases, and quality control samples distributed in external quality assessment programs. Results: LoB, LoD and LoQ at 20% and 10% CV values of the Access hstni method were 0.6, 1.3, 2.1 and 5.3 ng/l, respectively. The Access hstni method showed analytical performance significantly better than that of the Access AccuTnI+3 method and similar results to those of the hs ARCHITECT ctni method. Concentrations measured with the Access hstni methods showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-ctni methods, although there were systematic differences between these two. There was no difference between ctni values measured by Access hstni in heparinized plasma and serum samples, whereas there was a significant difference between ctni values respectively measured in EDTA and heparin plasma samples. Conclusions: Access hstni has analytical sensitivity parameters significantly improved compared to those of the Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform. PERFORMANCE EVALUATION OF ACCESS hstni 5

Beckman Coulter s high-sensitivity cardiac troponin I assay can measure very low cardiac troponin concentrations with excellent precision. This test may help physicians for both the early diagnosis of myocardial infarction and for future risk stratification in and outside the acute coronary syndrome setting. Peter Kavsak, Ph.D. Associate Professor, Department of Pathology and Molecular Medicine, McMaster University, Canada 6

ACCESS hstni METHOD COMPARISONS Analytical comparison of three different versions of a high-sensitivity cardiac troponin I assay over 10 years Kavsak PA, Worster A, et al. Clin Chim Acta 2017; 475:51 55 Background: Concerns have been raised about the long-term analytical performance of high-sensitivity cardiac troponin (hs-ctn) assays, with respect to different reagent formulations, lots and instrumentation. Our goal for the present study was to compare three different versions of an hs-ctni assay in two different study populations to evaluate if assay reformulation over 10 years has also affected the analytical results. Methods: Beckman Coulter s CE marked Access hstni assay (2017 version) was tested in 100 lithium heparin plasma samples which had prototype hs-ctni assay results from 2007 and in 100 serum samples which had enhanced hs-ctni assay results from 2011 with comparison performed by Passing-Bablok regression. The Beckman Coulter troponin results from 2017 and 2011 from the serum samples were also compared to the Abbott ARCHITECT i1000 hs-ctni results (2013) with threefold differences used to identify possible outliers. Freeze/thaw stability testing (-20 C) was also performed on normal ctni (Beckman Coulter=4.0ng/L; Abbott=5.3ng/L) and high ctni concentration (Beckman Coulter=77.6ng/L; Abbott=126.1ng/L) lithium heparin plasma pools for both hs-ctni assays. Results: After three freeze-thaws the Beckman Coulter Access hstni assay yielded minor decreases in concentrations (normal pool -0.7ng/L and high pool -12.6ng/L lower). Regression analyses yielded the following relationship between the Beckman Coulter s hs-ctni versions: 2017 hs-ctni=2.0*(2007 prototype hs-ctni)- 5.1ng/L and 2017 hs-ctni=1.04 (2011 enhanced hs-ctni)-2.5ng/l. Compared to the Abbott 2013 hs-ctni results, the 2011 Beckman Coulter enhanced version had eight results threefold higher, with the 2017 Beckman Coulter version yielding six results threefold lower. Conclusions: The 2017 Beckman Coulter hs-ctni version (Access hstni) is closely aligned with the previous enhanced hs-ctni assay and appears to have reduced the frequency of aberrantly high results. ACCESS hstni METHOD COMPARISONS 7

ACCESS hstni METHOD COMPARISONS Macrocomplexes and discordant high-sensitivity cardiac troponin concentrations Kavsak PA, Roy C, et al. Ann Clin Biochem 2017 November. [Epub ahead of print] Background: Analytical comparisons between different high-sensitivity cardiac troponin (hs-ctn) assays are important for reassurance of results performed with different methodologies and to identify potential interferences or confounders to result interpretation. Objective: Our objective in the present study was to compare Beckman Coulter s latest Access hstni assay to Abbott s hs-ctni assay and to assess agreement between results. Methods: Two hundred EDTA plasma samples that had clinically reported hs-ctni results from the Abbott ARCHITECTi2000 that spanned the analytical range were stored (median = 4 h), re-centrifuged and retested for hs-ctni on the Abbott ARCHITECTi1000 and Beckman Coulter Access2 analyzers. Passing-Bablok regression and fold differences were evaluated, with differences approximately threefold between results further subjected to Roche hs-ctnt testing and polyethylene glycol precipitation. Results: The Beckman Coulter and Abbott hs-ctni concentrations were correlated (r = 0.95) with Beckman Coulter yielding proportionally lower concentrations (slope = 0.78; 95%CI: 0.74-0.85). There were 12 samples that yielded Abbott hs-tni concentrations threefold higher than the Beckman Coulter Access hstni concentrations, of which nine samples from seven different patients had sufficient quantity for additional testing. All seven patients had macrocomplexes, as determined with polyethylene glycol precipitation, which affected the Abbott hs-ctni assay. One patient with Abbott hs-ctni results > 1,300 ng/l had polyethylene glycol, heterophile antibodies and creatine kinase-mb testing performed, which confirmed that a macrocomplex most likely affected the Abbott and Roche (hs-ctnt = 65 ng/l) assays but not the Beckman Coulter (hs-ctni = 12 ng/l) assay. Conclusion: The hs-ctni concentrations obtained from EDTA plasma between the Beckman Coulter and Abbott assays are highly correlated, with large differences in concentrations ( 3-fold) between Abbott and Beckman Coulter assays possible due to macrocomplexes impacting the Abbott hs-ctni assay. 8 ACCESS hstni METHOD COMPARISONS

ACCESS hstni METHOD COMPARISONS Assessing matrix, interferences and comparability between the Abbott Diagnostics and the Beckman Coulter high-sensitivity cardiac troponin I assays Kavsak PA, Malinowski P, et al. Clin Chem Lab Med 2018 February. [Epub ahead of print] Background: Analytical evaluation of high-sensitivity cardiac troponin (hs-ctn) assays, with particular attention to imprecision, interferences and matrix effects, at normal ctn concentrations, is of utmost importance as many different clinical algorithms use concentration cutoffs <10 ng/l for decision making. Objective: The objective for the present analytical study was to compare the new Beckman Coulter hs-ctni assay (Access hstni) to Abbott s hs-ctni assay in different matrices, and for different interferences, with a focus on concentrations < 10 ng/l. Methods: The limit of blank (LoB) and the limit of detection (LoD) were determined in different matrices for the Beckman Coulter Access hstni assay. Passing-Bablok regression and difference plots were determined for 200 matched lithium heparin and EDTA plasma samples for the Beckman Coulter assay and 200 lithium heparin samples for the Abbott assay. Both EDTA and heparin plasma samples were also evaluated for stability under refrigerated conditions, for endogenous alkaline phosphatase interference, and for hemolysis and icterus. Results: The Beckman Coulter Access hstni assay LoB was 0.5 ng/l with the following range of LoDs = 0.8 1.2 ng/l, with EDTA plasma yielding lower concentrations as compared to lithium heparin plasma (mean difference = 14.9%; 95% CI = 16.9 to 12.9). Below 10 ng/l, lithium heparin ctni results from the Beckman Coulter assay were on average 1.1 ng/l (95% CI = 0.7 to 1.5) higher than the Abbott results, with no difference between the methods when using EDTA plasma (mean difference = 0.1 ng/l; 95% CI = 0.3 to 0.2). Low ctni concentrations were less effected by interferences in EDTA plasma. Conclusions: The Access hstni method can reliably detect normal ctni concentrations with both lithium heparin and EDTA plasma being suitable matrices. ACCESS hstni METHOD COMPARISONS 9

High-sensitivity assays such as Beckman Coulter s Access hstni have enabled emergency clinicians to make significant changes to assessment practices for patients with suspected ACS. The value of adopting this new assay into clinical care may be realized by using validated, accelerated diagnostic protocols, which have been shown to safely improve patient care. Louise Cullen, MBBS Emergency Physician, Brisbane, Australia Joint Principle Researcher in the ASPECT and ADAPT trials 10

ACCESS hstni IN CLINICAL PRACTICE High-sensitivity cardiac troponin I immunoassay reduces the chance of patient misclassification in the emergency department Lippi G, Sanchis-Gomar F, et al. J Lab Precis Med 2017; 2:93. Background: Recent evidence attests that high-sensitive (HS) cardiac troponin I (ctni) immunoassays have practical and organizational advantages for managing patients presenting to the emergency department (ED) with suspected acute myocardial infarction (AMI). Nevertheless, the clinical advantages of these techniques over the former contemporary-sensitive (CS) methods remain elusive. This study was designed to verify whether a HS ctni immunoassay may decrease the chance of patient misclassification upon ED admission. Methods: The study population consisted of 57 consecutive patients admitted to the ED of the University Hospital of Parma (Italy) with suspected AMI. Blood samples were collected immediately upon ED presentation and ctni was measured with both CS (Beckman Coulter AccuTnI+3) and HS (Beckman Coulter Access hstni) immunoassays. The best cutoff for diagnosing AMI was derived from receiver operating characteristic (ROC) curves. The imprecision at the assayspecific cutoffs was calculated for both immunoassays by measuring scalar dilutions of a sample with high ctni value serially diluted until reaching a virtually unmeasurable ctni value. The potential impact on patient misclassification was then estimated as the sum of potential false-positive and false-negative results, expressed as percentages. Results: A final AMI diagnosis was made in 9/57 (16%) patients. The area under the curve (AUC) was not significantly different between CS (AccuTnI+3) or HS (Access hstni) immunoassays (0.89 vs. 0.90; P=0.393). The best diagnostic cutoffs were 20 and 18 ng/l for CS ctni and HS ctni, respectively. The assay imprecision was 22.0% at 20 ng/l for CS ctni and 3.4% at 18 ng/l for HS ctni, which were then associated with 3.2% and 0.5% chance of patient misclassification, respectively. Conclusion: The improved diagnostic accuracy represents an additional aspect in favor of introducing HS immunoassays for accurate triage of patients admitted to the ED with suspected AMI, especially in those displaying nondiagnostic ctni values at presentation. ACCESS hstni IN CLINICAL PRACTICE 11

ACCESS hstni IN CLINICAL PRACTICE Diagnostic accuracy of a new high-sensitivity troponin I assay and five accelerated diagnostic pathways for ruling out acute myocardial infarction and acute coronary syndrome Greenslade J, Carlton EW, et al. Ann Emerg Med 2018; 71(4):439-451. Objective: This diagnostic accuracy study describes the performance of five accelerated chest-pain pathways, calculated with the new Beckman Coulter Access hstni assay. Methods: High-sensitivity troponin I was measured with presentation and 2-hour blood samples in 1,811 patients who presented at an emergency department (ED) in Australia. Patients were classified as being at low risk according to five rules: modified accelerated diagnostic protocol to assess patients with chest pain symptoms using troponin as the only biomarker (m-adapt), the Emergency Department Assessment of Chest Pain Score (EDACS) pathway, the History, ECG, Age, Risk Factors, and Troponin (HEART) pathway, the No Objective Testing Rule, and the new Vancouver Chest Pain Rule. Endpoints were 30-day acute myocardial infarction and acute coronary syndrome. Measures of diagnostic accuracy for each rule were calculated. Results: Data included 96 patients (5.3%) with acute myocardial infarction and 139 (7.7%) with acute coronary syndrome. The new Vancouver Chest Pain Rule and No Objective Testing Rule had high sensitivity for acute myocardial infarction (100%; 95% confidence interval [CI] 96.2% to 100% for both) and acute coronary syndrome (98.6% [95% CI 94.9% to 99.8%] and 99.3% [95% CI 96.1% to 100%]). The m-adapt, EDACS, and HEART pathways also yielded high sensitivity for acute myocardial infarction (96.9% [95% CI 91.1% to 99.4%] for m-adapt and 97.9% [95% CI 92.7% to 99.7%] for EDACS and HEART), but lower sensitivity for acute coronary syndrome ( 95.0% for all). The m-adapt, EDACS, and HEART rules classified more patients as being at low risk (64.3%, 62.5%, and 49.8%, respectively) than the new Vancouver Chest Pain Rule and No Objective Testing Rule (28.2% and 34.5%, respectively). Conclusions: In this cohort of patients with a low prevalence of acute myocardial infarction and acute coronary syndrome using the Beckman Coulter s Access hstni assay with the new Vancouver Chest Pain Rule or No Objective Testing Rule enabled approximately one-third of them to be safely discharged after 2-hour risk stratification with no further testing. The EDACS, m-adapt, or HEART pathway enabled half of ED patients to be rapidly referred for objective testing. 12 ACCESS hstni IN CLINICAL PRACTICE

ACCESS hstni IN CLINICAL PRACTICE Evaluating rapid rule-out of acute myocardial infarction by use of a high-sensitivity cardiac troponin I assay at presentation Greenslade J, Cho E, et al. Clin Chem 2018 February. [Epub ahead of print] Background: Low concentrations of cardiac troponin (ctn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (Access hstni) assay to identify a single test threshold that can safely rule out AMI. Methods: This analysis used stored samples collected in two prospective observational studies. In all, 1,871 patients presenting to a tertiary emergency department with symptoms of acute coronary syndrome had blood taken for measurement of ctni on presentation. The end point was type 1 myocardial infarction (T1MI). Sensitivity and negative predictive value (NPV) were calculated for hs-ctni values below the 99th percentile. Results: Ninety-eight patients had T1MI (5.2%), and 638 (34.1%) patients had an hs-ctni <2 ng/l (limit of detection), with sensitivity of 99.0% (95% CI, 94.4% 100%) and NPV of 99.8% (95% CI, 99.1% 100%). No hs-ctni value above a concentration of 2 ng/l achieved sensitivity of 99%. However, an NPV of 99.5% was achieved at values < 6 ng/l. A cutoff <6 ng/l enabled 1,475 (78.8%) patients to be ruled out on presentation with sensitivity of 93.9% (95% CI, 87.1% 97.7%). Conclusions: A single baseline ctn < 2 ng/l measured with the Access hstni assay performed well for rule-out of AMI. This cutoff concentration identified 99% of patients with AMI and could reduce the number of patients requiring lengthy assessment. A cutoff of <6 ng/l yielded a high NPV but missed more cases of AMI than would be acceptable to clinicians. ACCESS hstni IN CLINICAL PRACTICE 13

14 NOTES

NOTES 15

This brochure is provided for your information. Beckman Coulter is not promoting any of its products for any purpose other than those specifically approved in the product s labeling and instructions for use. Learn more at beckmancoulter.com/hstni Brochure is not for distribution in the U.S. 2018 Beckman Coulter, Inc. All rights reserved. Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks mentioned herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. For Beckman Coulter s worldwide office locations and phone numbers, please visit www.beckmancoulter.com/contact BR-95837