HYCON Device. Fast, precise and successful space closure made easy! 25 years - around the globe research - design - manufacturing - distribution

Similar documents
04 Inserting the HYCON TUBE

SURGICAL MODEL ACCURACY DEVICE. 25 years - manufacturing and distribution - around the globe research - design - manufacturing - distribution

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

There is one thing different. Everything.

Archwire Insertion and Disengagement Instruments Technique Guide

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

THE POWER OF PRECISION

The Tip-Edge appliance and

SnapLink Re-Convertible Tube

Space Closure Biomechanics Applied Using The MBT System Technique

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

MemRx Orthodontic Appliances

class II correction FLEX DEVELOPER SMART INNOVATION Durable Effective Bringing German Engineering to Orthodontics

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

The Hycon Device. , Space Closure... fast, precise and successful - every patient, every time!

Gentle-Jumper- Non-compliance Class II corrector

Dual Force Cuspid Retractor

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

wiirre e a a n n d d w wiirre e ffo orrms ms

The management of impacted

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Passive friction active control

ORTHOdontics SLIDING MECHANICS

Orthodontic Treatment Using The Dental VTO And MBT System

Case Report. profile relaxed relaxed smiling. How would you treat this malocclusion?

Expansion screws. Perfect in form, function and design.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Enhanced Control in the Transverse Dimension using the Unitek MIA Quad Helix System by Dr. Sven G. Wiezorek

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

Aesthetic Brackets and Accessories

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

Non-osseointegrated. What type of mini-implants? 3/27/2008. Require a tight fit to be effective Stability depends on the quality and.

Mesial Step Class I or Class III Dependent upon extent of step seen clinically and patient s growth pattern Refer for early evaluation (by 8 years)

A smile can conquer the world. Introducing the Quick bracket range.

Arch Development: Clear Fixed Appliance vs. Aligner Treatment

Bracket Systems. A good bracket is the foundation of a good treatment plan... Go ahead, choose the best. Metal Bracket.

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M.

A Novel Method of Altering the Buccal Segment Relationship

No. 1 in the USA and Germany

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to

THE MBT VERSATILE+ APPLIANCE SYSTEM

2007 JCO, Inc. May not be distributed without permission.

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Flip-Lock HERBST Appliance COMFORT. CUSTOMIZATION. ADVANCED ENGINEERING.

Lab Forms and Communications Precise Indirect Bonding Systems.

Technique Guide. Orthodontic Bone Anchor (OBA) System. Skeletal implants for the orthodontic movement of the teeth.

CLASS II CORRECTION SIMPLIFIED

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

Efficient Bonding Protocol for the Insignia Custom Bracket System

Incognito. Appliance System goes Digital. 3Unitek. Now in 3D. The Incognito Appliance System Digital Setup with 3D PDF Documentation

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

The Inman Aligner. The Inman Aligner,* a versatile removable

The 20/20 Molar Tube. Ronald M. Roncone, D.D.S., M.S.

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

Intraoral molar-distalization appliances that

Mx1 to NA = 34 & 10 mm. Md1 to NB = 21 & 3 mm.

Crowding and protrusion treated by unusual extractions

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence.

With judicious treatment planning, the clinical

A New Fixed Interarch Device for Class II Correction

Correction of Crowding using Conservative Treatment Approach

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

6. Timing for orthodontic force

Molar anchorage loss has been shown to occur

Discover precision! EVOLUTION SLT and JOY Lingual. Precise Lingual Treatment Systems for 2D and 3D Cases. Bringing German Engineering to Orthodontics

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

Lingual correction of a complex Class III malocclusion: Esthetic treatment without sacrificing quality results.

Mandibular Protraction Appliance IV

THE USE OF VACCUM FORM RETAINERS FOR RELAPSE CORRECTION

The Science Behind The System Clinical Abstracts, Volume 2

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

Clarity. Form meets function: Discover the science behind a versatile self-ligating bracket system. Aesthetic Orthodontic Solutions

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

Controlled Space Closure with a Statically Determinate Retraction System

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

The Rondeau System. Brackets, Bands, Buccal Tubes and Archwires. Orthodontic supplies recommended by Dr. Brock Rondeau

TOL

THE JASPER JUMPER APPLIANCE; USAGE, EFFECTS AND RECENT MODIFICATIONS

Table of Contents Section 6 Table of Contents

Low-Force Mechanics Nonextraction. Estimated treatment time months (Actual 15 mos 1 week). Low-force mechanics.

BRACKET CHOICES SYSTEM CHOICES. Empower 2 reconvertible molar tubes provide versatility without compromise.

Archwires & Accessories

ortho case report Sagittal First international magazine of orthodontics By Dr. Luis Carrière Special Reprint

Ectopic upper canine associated to ectopic lower second bicuspid. Case report

SMILE Rx. Naturally beautiful: SMILE system. BioCosmetic -archwires

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

S.H. Age: 15 Years 3 Months Diagnosis: Class I Nonextraction Severe crowding, very flat profile. Background:

clinical orthodontics article

Crowded Class II Division 2 Malocclusion

#39 Ortho-Tain, Inc

Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire

OrthoLox Coupling-System

Skeletal Class III patients can be some of the CASE STUDY. By Jeffery Gerhardt, DDS. Acceptable Results Likely. Poor Results Likely. Fig.

Transcription:

SMART INNOVATION HYCON Device Fast, precise and successful space closure made easy! 25 years - around the globe research - design - manufacturing - distribution

2 The HYCON Device SMART INNOVATION Fast, precise, successful space closure and midline corrections made easy! Eliminating guesswork and stress when closing spaces. Amount of force, the length of force application, the degree of archwire deflection, the amount of friction, the stress of closing loops, the difficulty in handling...space closing was a long list of difficult, stressful unknowns. The challenge to eliminate this long list of problems was brought to me by Dr. Winifried Schütz. His dream appliance consisted of a post and screw and presented a truly technical-mechanical challenge. The HYCON Device is designed specifically to provide the optimal metabolic state for safe, fast and predictable tooth movement. To achieve adequate tissue reaction very little force is needed, however with the common space closing techniques, additional force is always required to overcome the friction within the mechanical system. The mechanics of a screw can be precisely measured - the size of the threads is directly proportional to the movement of the screw. The amount of force generated by the screw is adequate enough to overcome any amount of frictional forces, but does not generate any additional dynamic force, providing the perfect stimuli for tooth movement. Once we understood this principal, exact screw thread size was calculated, now we were able to mathematical calculate the distance the screw travelled, setting distance as our known calculator for safe, efficient and predictable tooth movement, putting the orthodontist in control of treatment. Successful My colleagues tell me that they are able to treat cases with the HYCON device that before would have been beyond therapy. I close all my spaces with the HYCON it has never failed me. Dr. Schütz, Germany SMART INNOVATION Fast The HYCON is activated in small steps at intervals that create an intermittent tooth movement. This allows recovery of the tissue in-between activations, and provides the physiological stimulus for the alteration processes. This perfect balance provides a high efficiency in tooth movement HYCON Tube Post inserted into the auxiliary-tube of your double buccal tube. Painless Activated in small steps at intervals best suited to maintain adequate blood supply, closely emulates ideal bodily movement and produces pain free space closure for the patient Precise The movement of the tooth is determined solely by the advancement of the thread of the screw. The thread has been precisely calculated to a pitch of 0.014, now you can precisely calculate this pitch by number of turns to precisely advance the screw and in-turn close the space with complete understanding and control HYCON Clip On Clips on directly to your archwire (perfect when no auxiliary tube is available) Easy Easily installed at the beginning of space closure with two options to choose from. Can be used with or without an auxiliary tube on your buccal tube. Also easily activated, a small screwdriver with a uniquely design safety head is simply used to turn the screw

3 Eliminate the uncertainties with space closure The force necessary to move a tooth must overcome the friction between arch-wire and bracket, and also must stimulate tissue response. With elastic forces the amount of stretching or deflection is proportional to the total force required. In order to achieve the appropriate amount of force, the activation length of an elastic mechanism has to be far greater than the periodontal gap. In contrast to this the threaded screw-type mechanism allows the separation of force and distance. The movement of the tooth is determined solely by the advancement rate of the thread and the amount of activation turns. Being independent of elastic forces it is thus possible to exert a very precise activation at a fairly high force level, but at a very short and controlled distance. Speed up treatment optimal recovery of the periodontal tissue The HYCON is activated in small steps at intervals which can be determined according to the condition of the periodontal tissue. By creating intermittent tooth movement, the HYCON allows recovery of the tissue in between activation steps. In contrast to the characteristics of elastic elements of force, where the power being generated is proportional to the activation stretch - a screw driven mechanism enables the separation of activation distance and force. The screw s force only plays a role insofar as being adequate enough to overcome frictional forces. After the adjustment of the HYCON screw the appliance is once again passive. There are no existing elastic forces, what remains from the activation is a slight increase in tissue pressure. This is the physiological stimulus for the desired alteration processes. Alkaline phosphatase study, used as an indicator substance, increased 140%. The alkaline phosphatase, bone specific also known as bones alkaline phosphatase BAP, is an enzyme that is active in the alkaline milieu. It is generated as a by-product of bone synthesis, produced by the osteoblasts and additionally serves as a marker for bone regeneration processes. From this Prof. Dr. Anmol Khala concluded, that out of the quantity of measured alkaline phosphatase the activity of the bone metabolism and consequently the rate of bone turnover can be determined. ALKALINE PHOSPHATASE LEVEL ( PERCENTAGES ) 250% 225% 200% 175% 150% 125% 100% Increase of alkaline phosphatase level during tooth movement within 21 days. BASE LINE 7 DAYS 14 DAYS Sliding mechanic Hycon Device Alkaline phosphatase level of unmoved teeth (Base Line) 21 DAYS Data reported by Dr. A. Khala 2005.

4 His experiment consisted of measuring the concentration of alkaline phosphatase in the gingival creviscular fluid of the shifted tooth. Here, the teeth - divided into two groups were moved by different mechanisms. Group 1 was drifted by sliding mechanics, while with group 2 the Hycon was put into action. After a 3 week treatment period, there was a significant difference in the amount of alkaline phosphatase. Based on the phosphatase level of unmoved teeth, set at 100 percent, a considerable increase could be discovered in both groups. While in group 1 there was an increase of 65 percent, in group 2 (the Hycon group) the measured level of increase was found to be approximately 140 percent. This indicates that group 2 had the highest metabolic activity. Consequently, the largest rate of bone turnover and hence quickest tooth movement took place here. Clinical Case Class I dental pattern Class II skeletal pattern This 30.4 year old male presented with a Class I dental pattern and a moderate Class II skeletal pattern. He showed severe crowding in his lower anterior segment. Four first bicuspids were extracted. During treatment space closure occurred routinely in the lower arch however was slower in the HYCON Tube upper arch. The HYCON device was used in the upper arch to efficiently complete space closure. Photos showing space closure with the HYCON with a.019 x.025 stainless steel wire. Space closure took 3 months. case by: Dr. Schütz HYCON ClipOn Designed specifically with a support-wire which is inserted into the auxiliary-tube of the molar band from the mesial side and bent back. If a double buccal tube is not available, the HYCON ClipOn simply clips onto the archwire. A double buccal tube is required for the use of this appliance. Holding pin of the HYCON Tube is inserted into auxiliary tube on your buccal tube. HYCON self-ligating locking clip is shown in open state, revealing the HYCON's slot. Close the HYCON ClipOn by applying pressure with the pliers. HYCON order info.022 Sales Unit HCN-018-5 HCN-022-5 5 Patient Kit HYCON ClipOn HCNC-018-5 HCNC-022-5 5 Patient Kit *Available in.018 slot technique with a.018x.025 support wire *Available in.022 slot technique with a.021x.025 support wire.018 HYCON Tube* Item # If the 1st and 2nd molars are banded place the HYCON ClipOn distally to the 1st molar. If the 2nd molar is not banded place the HYCON ClipOn mesially to the first molar

5 Patients Beginning Records This 22.8 year old male presented with a Class I dental and skeletal pattern. He showed a satisfactory profile and had previously been treated orthodontally with extraction of his lower second bicuspids. His upper lateral incisors were congenitally missing, however, upper space closure had not been completed during past orthodontic treatment. These spaces were closed during treatment with the Hycon (Note-This case was treated at the University of Southern California by Dr. Mark Fagin, under the supervision of Dr. McLaughlin.) Photos showing space closure wth the Hycon Device -.019 x.025 stainless steel wire. Photos showing completed case. Space closure was at the rate of 1mm per month.

6 Patients Beginning Records This 17.0 year old female presented with a Class I dental and skeletal pattern. She showed a satisfactory profile with moderate crowding in her upper and lower arches. Her lower first molars were restored with large restorations and her lower right first molar had developed a peri-apical abscess. Upper first bicuspids and lower first molars were extracted. The upper spaces were closed with normal sliding mechanics. Lower space closure was completed with the Hycon device. A.021 x.025 stainless steel wire was used in the lower arch to avoid any deepening of the curve of Spee during space closure. (Note-This case was treated at the University of Southern California by Dr. Steven Olsburgh, under the supervision of Dr. McLaughlin.) Hycon Device placed on mandibular arch. Please note size of extration spaces. Photos showing completed case. Space closure was at the rate of 1mm per month.

7

8 Head Office adenta GERMANY Adenta GmbH Gutenbergstrasse 9 D 82205 Gilching Germany +49 8105-73436 - 0 +49 8105-73436 - 22 Mail: info@adenta.com www.adenta.com Sales Office adenta SPAIN Adenta Spain S.L. c/león, 11, 08911 Badalona Barcelona España T. +34 933 844 705 F. +34 933 844 153 info@adentaspain.com www.adentaspain.com Sales Office adenta USA Adenta USA Inc 81 Clover Road Ivyland PA 18974 U.S.A 1-888-942-2070 toll free T. +1-215-942-2070 info@adentausa.com www.adentausa.com 06012014