Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments

Similar documents
IMRT for Prostate Cancer

IMRT - the physician s eye-view. Cinzia Iotti Department of Radiation Oncology S.Maria Nuova Hospital Reggio Emilia

Feasibility and initial dosimetric findings for a randomized trial using dose painted multi-parametric-mri defined targets in prostate cancer

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

Potential conflicts-of-interest. Respiratory Gated and Four-Dimensional Tumor Tracking Radiotherapy. Educational objectives. Overview.

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Would SBRT Hypofractionated Approach Be as Good? Then Why Bother With Brachytherapy?

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

8/3/2016. Outline. Site Specific IGRT Considerations for Clinical Imaging Protocols. Krishni Wijesooriya, PhD University of Virginia

From position verification and correction to adaptive RT Adaptive RT and dose accumulation

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Performance Evaluation of Calypso (R) 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients

Proton Therapy for Prostate Cancer. Andrew K. Lee, MD, MPH Director Proton Therapy Center

A Thesis. entitled. based on CBCT Data Dose Calculation. Sukhdeep Kaur Gill. Master of Science Degree in Biomedical Science

Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division

New Technologies for the Radiotherapy of Prostate Cancer

Changing Paradigms in Radiotherapy

Rectal dose and toxicity dosimetric evaluation for various beam arrangements using pencil beam scanning protons with and without rectal spacers

Stereotactic MR-guided adaptive radiation therapy (SMART) for locally advanced pancreatic tumors

Overview of Advanced Techniques in Radiation Therapy

Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system

Learning Objectives. New Developments in Radiation Therapy Targeting. Respiration-Induced Motion. Targeting Uncertainty in RT

MRI Based treatment planning for with focus on prostate cancer. Xinglei Shen, MD Department of Radiation Oncology KUMC

Helical Tomotherapy Experience. TomoTherapy Whole Brain Head & Neck Prostate Lung Summary. HI-ART TomoTherapy System. HI-ART TomoTherapy System

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

Pitfalls in SBRT Treatment Planning for a Moving Target

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Learning objective. Outline. Acknowledgements. KV CBCT Imaging Part I. R Hammoud AAPM 2008 CE-Therapy (SAM) 1

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

OPTIMIZATION OF COLLIMATOR PARAMETERS TO REDUCE RECTAL DOSE IN INTENSITY-MODULATED PROSTATE TREATMENT PLANNING

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Comparing Current Options in Radiation Therapy. Howard M. Sandler, MD Ronald H. Bloom Family Chair in Cancer Therapeutics Cedars-Sinai Medical Center

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Radiotherapy Advances

Advanced Technology Consortium (ATC) Credentialing Procedures for 3D Conformal Therapy Protocols 3D CRT Benchmark*

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Reena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery

Modern Dose Fractionation and Treatment Techniques for Definitive Prostate RT

HDR Brachytherapy: Results and Future Studies in Monotherapy

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

1 : : Medical Physics, Città della Salute e della Scienza, Torino, Italy

CyberKnife Radiotherapy For Localized Prostate Cancer: Rationale And Technical Feasibility

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.

Image Fusion, Contouring, and Margins in SRS

Overview of MLC-based Linac Radiosurgery

Individualized dosimetry treatment planning for liver irradiation

ART for Cervical Cancer: Dosimetry and Technical Aspects

Measurement of Dose to Critical Structures Surrounding the Prostate from. Intensity-Modulated Radiation Therapy (IMRT) and Three Dimensional

What do we Know About Adaptive Radiotherapy? Lei Dong, Ph.D. Scripps Proton Therapy Center San Diego, California

Margins in SBRT. Mischa Hoogeman

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

CALCULATION OF OPTIMAL MARGINS BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV)

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

PROSTATE CANCER, Radiotherapy ADVANCES in RADIOTHERAPY for PROSTATE CANCER

Applications of Modern Radiotherapy Systems

Motion gating and tracking techniques: overview and recent developments

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Measure the Errors of Treatment Set-Ups of Prostate Cancer Patient Using Electronic Portal Imaging Device (EPID)

Quantification of the margin required for treating intraprostatic lesions

BLADDER RADIOTHERAPY PLANNING DOCUMENT

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

On the use of 4DCT derived composite CT images in treatment planning of SBRT for lung tumors

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Optimal Imaging and Technical Aspects of Prostate SRT

Comparison of Interfacility Implementation of Essential SBRT Components. Keith Neiderer B.S. CMD RT(T) VCU Health System

Outline. Contour quality control. Dosimetric impact of contouring errors and variability in Intensity Modulated Radiation Therapy (IMRT)

Knowledge-Based IMRT Treatment Planning for Prostate Cancer: Experience with 101. Cases from Duke Clinic. Deon Martina Dick

SRS Uncertainty: Linac and CyberKnife Uncertainties

The Radiation Biology of Dose Fractionation: Determinants of Effect

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015

Reirradiazione. La radioterapia stereotassica ablativa: torace. Pierluigi Bonomo Firenze

Physics Treatment Margins. Laurence Court University of Texas MD Anderson Cancer Center

Subject: Image-Guided Radiation Therapy

Innovazioni tecnologiche in Radioterapia" Sergio Fersino Radioterapia Oncologica

7/28/2012. Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures***

Department of Radiation Oncology University of Michigan Health Systems

Treatment of exceptionally large prostate cancer patients with low-energy intensity-modulated photons

Utilization of cone-beam CT for offline evaluation of target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment

Volumetric-based image guidance is superior to marker-based alignments for stereotactic body radiotherapy of prostate cancer

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Has radiotherapy the potential being focal?

Leksell Gamma Knife Icon A New User s Perspective

I. Equipments for external beam radiotherapy

Transcription:

Feasibility of 4D IMRT Delivery for Hypofractionated High Dose Partial Prostate Treatments R.A. Price Jr., Ph.D., J. Li, Ph.D., A. Pollack, M.D., Ph.D.*, L. Jin, Ph.D., E. Horwitz, M.D., M. Buyyounouski, M.D., C-M. Ma, Ph.D. Fox Chase Cancer Center, Philadelphia, PA *University of Miami Miller School of Medicine, Miami, FL

Proposed IMRT Dose Escalation Trial Intermediate Risk Stratify PSA Gleason ±STAD R a n d o m i z e SIMRT 76 Gy in 38 (2.0 Gy) fxs SIMRT + IMRT Boost Boost bulky tumor 76 Gy in 38 (2.0 Gy) fxs + 10 Gy Boost (single fraction)

Rationale Local persistence after RT remains a problem, even at high doses Confirmed by prostate biopsy Appears related to dominant lesion (hypoxia?) Builds on prior FCCC randomized trial

FCCC Experience with 10 Gy/fx In-house protocol; 46 Gy to pelvis (IMRT) 9.75-10.75 Gy HDR boost weeks 1 & 3 ~45 men over last 9 years <10% risk of rectal bleeding/urethral strictures Same short-term term side effects as IMRT

We need advanced imaging for Targeting (what part(s) ) of the prostate do we need to boost) Treatment Planning (we need to reduce PTV margins to stay below critical structure tolerances) Treatment Delivery (we need to know where the target(s) ) are during treatment delivery, e.g. tracking)

MRS of Prostate Citrate Cho Cr Citrate levels with prostate Ca PPM 3 2 Cho Cr Citrate Choline levels with prostate Ca High (choline+creatine)/citrate ratio Cancer PPM 3 2 Courtesy of Radka Stoyanova, Ph.D. (original data from UCSF)

MRS Correlate MRS findings with high tumor density regions prior to treatment planning May define based on palpation Additionally, use non-invasive MRS in lue of 2-2 year follow-up biopsy (initially we ll correlate results with biopsies)

Hypointense regions (indicative of Ca) choline choline citrate choline Courtesy of Radka Stoyanova, Ph.D.

Problems Limiting dose to rectum during the 1 st 76 Gy Limiting dose to rectum during the 10 Gy boost Evaluating rectal constraints during the planning of the 10 Gy boost Evaluating the rectal constraints of the composite plan

DVH Acceptance Criteria PTV 95 % 100% Rx R 65 Gy 17%V R 40 Gy 35%V B 65 Gy 25%V B 40 Gy 50%V FH 50 Gy 10%V Good DVH R 40 = 22.7% PTV 95 = 100% R 65 = 8.3% R 40 = 19% B 65 = 8.4%

Good plan example (axial) 100% 90% 80% 70% 60% 50% CTV Effective margin The 50% isodose line should fall within the rectal contour on any individual CT slice The 90% isodose line should not exceed ½ the diameter of the rectal contour on any slice

R65 with PTV reduction 25 38cc prostate 3mm PTV 66cc prostate 20 20.2 3mm PTV 79cc prostate 3mm PTV Percent of Rectum at 65 Gy 15 10 13.4 7 16.3 6.8 13.7 8.9 7.5 16.1 5.9 9.2 101cc prostate 3mm PTV 127cc prostate 3mm PTV 214cc prostate 3mm PTV 5 1.1 0 1 Theoretically, we can limit dose to the rectum by decreasing PTV margins & using Calypso beacons for active tracking

Prostate IMRT Rectal Values Rectal Volume (%) 40.0 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 36.8 28.5 15.4 20.6 14.6 6.6 Average Values Max Values Min Values Average Prescription 79.2 Gy (78-80) Average Rectal Volume 50.4 cc (35.8-78.8) 14.3 R40 R65 R75 R80 Rectal Dose Cutpoints (Gy) 9.3 3.4 10 6.1 1.6

Equivalent dose at 2Gy/fx EQD2 = D[(d + (α/β( ))/(2 + (α/β( ))] D = total dose given with a fraction size of d

Assumptions Overall tx time is relatively unchanged; 76 Gy in 38 fractions followed by a boost of 10 Gy in a single fraction EQD 2 are additive If we limit the R 65 to 17% Vol in 38-40 fxs our results hold α/β = 2Gy (prostate); α/β = 4Gy (rectum) 10Gy boost 30Gy @ 2Gy/fx (prostate( prostate); 76 + 30 = 106 Gy

Prostate S Prostate I Boost Target Boost Target 76 Gy, 68, 61, 53, 46, 38 76 Gy, 68, 61, 53, 46, 38

Boost 10 Gy, 9, 8, 7, 6, 5 10 Gy, 9, 8, 7, 6, 5 EQD2 = D[(d + ( / ))/(2 + ( / ))] = 30 Gy { / 30 Gy, 27, 24, 21, 18, 15 prostate 30 Gy, 27, 24, 21, 18, 15 = 2.0 Gy}

Prostate spillover 30 Gy, 27, 24, 21, 18, 15 Boost target Issues of note -spillover dose into non-boost prostate volume (will result in increased overall dose at time of composite plan generation) -there are systems that allow the optimization on previously delivered dose (what happens to the boost dose/fraction?) -compressed dose gradient has been used for critical structure sparing (rectum) -this plan is for evaluation of target(s) only (α/β prostate = 2.0 Gy) -this plan cannot be used to evaluate the rectum (α/β rectum = 4.0 Gy)

106 Gy, 95, 85, 76, 65, 55 Increased overall dose to both targets: 85 Gy 95 Gy 106 Gy 95% of Prostate PTV ~84 Gy (vs 76 Gy) 95% of Boost PTV ~107 Gy (vs 106 Gy) 76 Gy

Volume-based scaling (initial plan) Our normal PTV margins (8 & 5 mm) result in dose-volume limit of 17% rectum receiving 65 Gy. 65 Gy/38 fx = 1.71 Gy/fx EQD 2 61.86 Gy limit P R 65 Gy

Volume-based scaling (initial plan) P R 35.59 Gy With decreased margins (3mm) 17% rectum receives ~ 35.59 Gy in 38 fractions resulting in a dose/fx of 0.9366 Gy. Therefore EQD 2 29.28 Gy (from the rectum s s perspective)

Rectal DVH with PTV Change 100 90 80 PTV 5mm posteriorly (original) PTV 3mm PTV 3mm (rectum EQD2 scaled) 17% Rectal Volume 70 Prostate Volume (%) 60 50 40 30 Rectum 5mm post margin 3mm post margin 20 17% rectal volume 10 0 0 10 20 30 40 50 60 70 80 Dose (Gy)

Rectal dose limit for boost plan The 10 Gy boost plan yields 3.09 Gy to 17% of the rectal volume EQD 2 3.65 Gy 29.28 Gy (EQD 2 initial) + 3.65 Gy (EQD 2 boost) = 32.93 Gy; well below the 61.86 Gy limit Composite plan: 32.91 Gy

Composite to 106 Gy 110 Prostate PTV 100 Prostate Boost Target PTV Percent Volume 90 80 70 60 50 40 Target data taken from composite plan generated using prostate α/β = 2.0 Gy 17% Vol receiving 32.91 Gy Boost Target Rectum 30 20 Rectal data taken from composite plan generated using rectum α/β = 4.0 Gy 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Dose (Gy)

Summary Single fraction high dose boosts to the prostate should be possible (dosimetrically( dosimetrically) Important issues with targeting & radiobiology PTV reduction is necessary (but is a 3mm margin necessary? Remember, 17% of rectum at 32.91 Gy only)

Dose Escalation Barriers Goals Highly Conformal Radiation Therapy Use reduced margins Uncertainty of Target Delineation Setup Error Patient and Organ Motion Target Deformation Uncertainty of Beam Delivery System Improve Disease Control Reduce Complications

3D Localization Techniques for Prostate Treatment Skin Markers with portal image verification Ultrasound images BAT, I-BEAMI etc. In room CT/MRI -- CT-on on-rails and Cone beam CT, Tomotherapy,, cobalt machine with MRI Implanted Fiducial markers with OBI Implanted Beacon transponders with Calypso 4D localization system

4D Localization Techniques for Prostate Treatment Orthogonal X-rayX images with implanted fiducial markers Calypso 4D localization system with Implanted Beacon transponders

Calypso 4D Localization Wireless miniature Beacon Electromagnetic Transponders Accurate, objective guidance for target localization and continuous, real-time tracking Actual size: Length = ~8.5mm Diameter = 1.8mm System Beacon Electromagnetic Transponder

Clinical Procedure for Calypso Patient 1. MRI scan patient 2. Implant Beacon Transponders 3. CT scan patient at least a week later 4. Complete treatment planning, input isocenter coordinates and transponder coordinates into the Calypso system Medium frequency High frequency low frequency Unique Frequencies Identify Location

Electromagnetics Locate and Track Continuously GPS for the Body Step 1 Step 2 Excitation Waveform Response Waveform Source Coil Current Resonator Current Excitation Phase Ring Down Phase

Calypso System Prostate Localization Prostate rotation monitoring Prostate real-time motion tracking

Advantages and disadvantages of the Calypso system Advantages 4D, real-time tracking Localization Fast feed back Less operator dependence No additional dose Efficient workflow Can be used for gating Disadvantages Invasive implant Lack of anatomic information MRI artifacts Limited patient population Anti-coagulant or anti-platelet drug therapy Hip prosthesis, prosthetic implants Patients with large AP separation

Comparison with OBI for patient localization A. OBI images were taken when Calypso motion tracking was on B. Calypso readings were corrected by the amount of the average isocenter offset from morning QA results in the same period C. The OBI based-shifts shifts were then compared with the corrected Calypso offset reading Lateral Longitudinal Vertical FCCC patients 3 2 Difference (mm 1 0-1 -2-3

Error of skin marker based prostate localization lat long vert 20 Setup errorr(mm 15 10 5 0-5 -10-15 Number of setup L-R I-S P-A FCCC patients Mean (mm) (mm) σ (mm) -1.6 2.3 3.2-1.5 2.6 3.6 2.5 2.1 3.6 More than 65% of patients had > 5mm misalignment at setup based on skin markers

Beacon migration and prostate size change Ratio of distance between transponders 1.3 1.2 1.1 Apex-RB RB-LB Ratio 1 0.9 Apex-LB Apex-RB 0.8 RB-LB 0.7 Apex-LB 0.6 1 11 21 31 41 51 61 71 81 91 101 number of patients Ratio of intertransponder distance relative to the planning CT The First Treatment Apex-LB 0.97 Apex-RB 0.97 LB-RB 0.99 FCCC patients; can be >2mm The Last Treatment 0.94 0.92 0.96

Intrafractional motion Offset (cm 0.8 0.6 0.4 0.2 0-0.2-0.4-0.6 Lateral Long Vertical 0.0 0.9 1.8 2.7 3.6 4.5 5.4 6.3 7.1 8.0 8.9 9.8 10.7 Time (min) Offset (cm Lateral Long Vertical 0.2 0-0.2-0.4-0.6-0.8 0.0 1.2 2.3 3.5 4.6 5.8 7.0 8.1 9.3 10.4 11.6 12.8 13.9 15.1 Time (min) Lateral Long Vertical Offset (cm 0.3 0.2 0.1 0-0.1-0.2-0.3 0.0 1.2 2.4 3.6 4.8 6.0 7.2 8.4 Time (min) FCCC patients 3 patients 3 diff fractions

Intrafractional motion (775 fractions of 105 patients) Percentage of fractions that need intervention 29.3% for 3mm threshold 4.8% for 5mm threshold Percentage of time prostate is off the base line 13.4% for 3mm threshold 1.8% for 5mm threshold

Prostate Rotation Frequency(% 14 12 10 8 6 4 2 Mean= -1.5 degree SD = 6.4 degree 0-20 -16-12 -8-4 0 4 8 12 16 20 Rotation angle around the lateral axis (degree) 16 25 Frequency (% 14 12 10 8 6 4 2 0-10 -8-6 -4-2 0 2 4 6 8 10 Frequency (% 20 15 10 5 0-10 -8-6 -4-2 0 2 4 6 8 10 Rotation angle around longitudinal axis (degree) Rotation angle around vertical axis (degree) Mean= 0.0 degree, SD = 2.9 degree Mean= -0.2degree, SD = 1.9 degree FCCC patients

Translational Error Caused by Prostate Rotation θ x FCCC patients Rotated contour (20 patients) and found translational error when matching to planning CT Translational Error (mm 9 8 7 6 5 4 3 2 1 0-1 y= -0.0024x 2 + 0.3226x- 0.0082 0 5 10 15 20 25 30 Rotation Angle (Degree)

How much does motion tracking help during prostate treatment? - Quantitative analysis of potential PTV reduction

Population-Based Margin Calculation (CTV to PTV) m * = 2.0 + 0.7σ + S PTV Total systematic error = 2 del + 2 int er + 2 int ra + 2 mtd + 2 rot + 2 bds +L Total random error 2 2 2 σ = σ 2 int er + σ 2 int ra + σ mtd + σ rot + σ bds +L Total mean S = S del + S inter + S intra + S mtd + S rot + S bds + * Stroom JC et al, Int. J. Rad. Onc. Biol. Phys 43(4) pp. 905-919,1999 With a criteria of D 99 of CTV > 95% of the nominal dose on average

Geometrical Uncertainties 1. Delineation Error (C. Rasch et al) (del) L-R 1.7mm; S-I 2-3.5mm; A-P 2mm; 2. Geometrical Uncertainty of the beam delivery system (bds) bds = 0.5mm, δ bds = 0.7mm 3. Uncertainty of localization and motion tracking system (mtd) 4. Uncertainty caused by Beacon migration and prostate size change -- not included in the margin calculation 5. Geometrical Uncertainty Caused by Prostate Rotation (rot) 6. Setup residual error included in the intrafractional motion 7. Geometrical Uncertainty caused by intrafractional motion

Geometrical Uncertainty Including Intrafractional Motion and Resultant PTV Margins 105 patients with no intervention (mm) Mean (S) Left -0.05 Right 0.19 Sup 0.25 Inf 0.91 Ant 0.47 Post 0.55 (total) 2.12 2.12 2.94 2.94 3.02 3.02 σ (total) 1.66 1.66 2.88 2.88 3.19 3.19 Margin 5.3 5.6 8.2 8.8 8.8 8.8 How to reduce the effects of intrafractional motion?

Threshold-based Intrafractional Intervention Lateral Long Vertical Offset (cm 0.8 0.6 0.4 0.2 0-0.2-0.4-0.6 0.0 0.9 1.8 2.7 3.6 4.5 5.4 6.3 7.1 8.0 8.9 9.8 10.7 Beam Off Time (min) 1. Beam off (gated treatment) 2. Move prostate back to the base line by moving the table Lateral Long Vertical Lateral Long Vertical Offset (cm 0.2 0-0.2-0.4-0.6-0.8 0.0 1.2 2.3 3.5 4.6 5.8 7.0 8.1 9.3 10.4 11.6 12.8 13.9 15.1 Time (min) Offset (cm 0.2 0.1 0-0.1-0.2-0.3-0.4 0.0 1.2 2.4 3.7 4.9 6.1 7.3 8.5 9.8 11.0 12.2 13.4 14.6 Time (min)

4D treatments moving the couch and/or using DMLC 1. Correction of the translational error only 2. Correction of the translational error plus rotation

PTV Margins for Various Uncertainty Conditions 105 patients with/without intervention (mm) No intervention Left 5.3 Right 5.6 Sup 8.1 Inf 8.8 Ant 8.8 Post 8.8 5mm threshold 5.3 5.6 8.1 8.8 8.7 8.7 3mm threshold 5.3 5.6 8.0 8.5 8.8 8.3 4D Tx 5.5 5.3 7.8 8.3 9.0 7.6 4D Tx + Rotation Correction 4.5 4.3 4.9 5.3 6.0 4.6

Intrafractional motion (61 fractions of 7 patients who exhibited the largest intrafractional motion) The percentage time of prostate off the base line 41% for 3mm threshold 15% for 5mm threshold

PTV Margins 7 patients with/without intervention (mm) No intrafractional motion considered Left 5.2 Right 5.9 Sup 7.0 Inf 10.0 Ant 7.4 Post 10.6 5mm threshold (intra rotation not considered) 3mm threshold (intra rotation not considered) 4D Tx (additional uncertainty for tracking added; MLC tracking, couch) 4D Tx + Rotation Correction (all uncertainties added) 5.2 5.3 5.5 4.5 5.9 6.0 5.3 4.3 7.1 7.4 7.8 4.9 9.6 9.1 8.3 5.3 8.0 8.2 9.0 6.0 9.3 8.7 7.6 4.6

Conclusions Calypso 4D localization system is an accurate and convenient system for prostate localization and real-time motion tracking The prostate translational intrafractional motion is not a major contributor to the geometrical uncertainty for the general patient population and motion tracking during treatment plays a small role in treatment margin reduction. A small fraction of patients who have large intrafractional motion can benefit significantly from real-time motion tracking and threshold- based intervention. Effects caused by prostate rotation are more significant than the translational intrafractional motion. Rotation correction could help more on treatment margin reduction. One should use caution when reducing the treatment margins even with prostate motion tracking.