Mass Spectrometry. Actual Instrumentation

Similar documents
Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Edgar Naegele. Abstract

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Components of a Mass Spectrometer

Agilent 7700x ICP-MS

Supplementary Information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Lipidomic Analysis by UPLC-QTOF MS

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Determination of Amantadine Residues in Chicken by LCMS-8040

Bruker Daltonics. autoflex III smartbeam. The Standard in MALDI-TOF Performance MALDI-TOF/TOF. think forward

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

Mass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University

Authors. Abstract. Introduction. Environmental

Fundamentals of Soft Ionization and MS Instrumentation

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

SYNAPT G2-S High Definition MS (HDMS) System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Solving practical problems. Maria Kuhtinskaja

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

SCS Mass Spectrometry Laboratory

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

SUPPLEMENTARY MATERIAL

Ionization Methods. Neutral species Charged species. Removal/addition of electron(s) Removal/addition of proton(s)

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Mass Spectrometry Course Árpád Somogyi Chemistry and Biochemistry MassSpectrometry Facility) University of Debrecen, April 12-23, 2010

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Dienes Derivatization MaxSpec Kit

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Comparison of mass spectrometers performances

Measuring Lipid Composition LC-MS/MS

Supporting Information

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Supporting information

Introduction to LC/MS/MS

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Mass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Polymer Additive Analysis by EI and APCI

ANALYTICAL REPORT 1, 2

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry

CAMAG TLC-MS INTERFACE

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

Determination of red blood cell fatty acid profiles in clinical research

Steviol Glycosides from Stevia rebaudiana Bertoni

ANALYTICAL REPORT 1, 2

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Rapid and Robust Detection of THC and Its Metabolites in Blood

1. Sample Introduction to MS Systems:

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Characterization of an Unknown Compound Using the LTQ Orbitrap

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Analysis of Triglycerides in Cooking Oils Using MALDI-TOF Mass Spectrometry and Principal Component Analysis

FOURIER TRANSFORM MASS SPECTROMETRY

ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine.

ANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column

[ Care and Use Manual ]

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

Agilent s LC/MS Portfolio and Applications Examples

SUPPORTING INFORMATION:

MALDI-TOF. Introduction. Schematic and Theory of MALDI

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Mass spectrometry Technologies in Lipid chemistry

Uptake and Metabolism of Phthalate Esters by Edible Plants

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry

Sulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Vitamin D3 and related compounds by ESI and APCI

Transcription:

Mass Spectrometry Actual Instrumentation August 2017 See also http://www.uni-bielefeld.de/chemie/analytik/ms f additional infmation 1. MALDI TOF MASS SPECTROMETRY ON THE ULTRAFLEX 2 2. ESI MASS SPECTROMETRY ON THE ESQUIRE 3000 3 3. ACCURATE MASS ESI MASS SPECTROMETRY ON THE AGILENT 6220 4 4. EI MASS SPECTROMETRY ON THE AUTOSPEC X 5 5. ESI AND MALDI SPECTRA ON THE SYNAPT G2SI (Q-IMS-TOF MS) 6 6. HPLC/TLC ESI MASS SPECTROMETRY ON THE ZQ2000 7 7. GC/MS ON THE VARIAN SATURN II 8

- 2-1. MALDI TOF Mass spectrometry on the Ultraflex Samples were mixed on a polished steel target with 1 µl of matrix solution (either 50 mg/ml 2,5-DHB in 50% ACN, 0,1% TFA saturated DCTB in methanol). MALDI TOF mass spectra were recded with a Ultraflex MALDI-TOF/TOF mass spectrometer (Bruker Daltonik, Bremen, Germany) operated in reflectron mode (F very large analytes, e.g. proteins: linear mode). Ionisation was achieved using a LTB nitrogen laser MNL 200 (337 nm beam wavelength, 50 Hz repetition rate). Maximum resolution achieved with this instrument is approx. 20,000. The Instrument Default Calibration was used f calibrating the mass axis. The mass axis was externally calibrated with (PEG red phosphous 1 ) as calibration standard on the same target. The mass axis was internally calibrated with... as internal calibration standard. The spectra are recded with FlexControl Software 3.0 (Bruker Daltonik, Bremen, Germany) by accumulation and averaging of... single laser shots. FlexAnalysis 3.4 (Bruker Daltonik, Bremen, Germany) was used f processing the spectra. specify (example): MS (MALDI TOF, positive ions, Matrix, Nr.of summed Spectra) MS (MALDI TOF, negative ions, Matrix, Nr.of summed Spectra) F soft ionisation techniques relative (!) intensities in the spectra should not be cited because they are not reproducible in substance mixtures and on different MS instruments. If the isotopic cluster of a compound shall be cited as a proof f the elemental composition of a special compound, relative ion abundances have to be given as values (better) the cluster may be depicted in comparison with the calculated isotopic distribution. example ( use example depicted in the Esquire 3000 section): + + C26H47N8O13 C26H46N8O13Li Mass x: m/z of the pseudomolecular ion; M x: number of the compound it s fmula (C xh yo z) Lit.: 1 Sladkova, K., Houska, J., Havel, J. Rapid Comm. Mass Spectrom. 2009, 19, 3114-3118

- 3-2. ESI mass spectrometry on the Esquire 3000 Nano-ESI mass spectra were recded using an Esquire 3000 ion trap mass spectrometer (Bruker Daltonik GmbH, Bremen, Germany) equipped with a standard nano-esi source. Samples were introduced by static nano- ESI using in-house pulled glass emitters. Nitrogen served both as the nebulizer gas and the dry gas. Nitrogen was generated by a Bruker nitrogen generat NGM 11. Helium served as cooling gas f the ion trap and collision gas f MS n experiments. The spectra shown here are recded with the Bruker Daltonik esquirent 5.2 esquirecontrol software by the accumulation and averaging of several single spectra (as given in print outs). DataAnalysis software 3.4 was used f processing the spectra. MS (ESI, positive ions) MS (ESI, negative ions) MS/MS (ESI, P 1 (m/z XXX), positive ions) m/z (%) = P 1 [precurs] +, D 1 (int) [daughter 1] +, D 2 (int) [daughter 2] +,... MS 3 (ESI, P 1 (m/z XXX) P 2 (m/z YYY), positive ions) m/z (%) = P 2 [precurs] +, D 1 (int) [daughter 1] +, D 2 (int) [daughter 2] +,... F soft ionisation techniques relative (!) intensities in the spectra should not be cited (exception: MS n spectra) because they are not reproducible in substance mixtures and on different MS instruments. If the isotopic cluster of a compound shall be cited as a proof f the elemental composition of a special compound, relative ion abundances have to be given as values (better) the cluster may be depicted in comparison with the calculated isotopic distribution. example: Intens. x104 1.25 2219.53 [2M + H] + = 2218.6 1.00 0.75 2218.57 2220.46 C 136 H 216 N 8 O 16 + H + 0.50 2221.46 0.25 2222.49 2223.51 0.00 2216 2218 2220 2222 2224 2226 2228 m/z Mass x: m/z of the pseudomolecular ion M x: number of the compound it s fmula (C xh yo z) P x: m/z of the precurs ion D x: m/z of the daughter ion

- 4-3. Accurate Mass ESI mass spectrometry on the Agilent 6220 ESI mass spectra are recded using an Agilent 6220 time-of-flight mass spectrometer (Agilent Technologies, Santa Clara, CA, USA) in extended dynamic range mode equipped with a Dual-ESI source, operating with a spray voltage of 2.5 kv. Nitrogen served both as the nebulizer gas and the dry gas. Nitrogen was generated by a nitrogen generat NGM 11. Samples are introduced with a 1200 HPLC system consisting of an autosampler, degasser, binary pump, column oven and diode array detect (Agilent Technologies, Santa Clara, CA, USA) using a C18 Hypersil Gold column (length: 50 mm, diameter: 2.1 mm, particle size: 1,9 µm) with a sht gradient (in 4 min from 0% B to 98% B, back to 0% B in 0.2 min, total run time 7.5 min) at a flow rate of 250 µl/min and column oven temperature of 40 C. HPLC solvent A consists of 94.9% water, 5% acetonitrile and 0.1% fmic acid, solvent B of 5% water, 94.9% acetonitrile and 0.1% fmic acid. The mass axis was externally calibrated with ESI-L Tuning Mix (Agilent Technologies, Santa Clara, CA, USA) as calibration standard. The mass spectra shown here are recded in both profile and centroid mode with the MassHunter Wkstation Acquisition B.04.00 software (Agilent Technologies, Santa Clara, CA, USA). MassHunter Qualitative Analysis B.07.00 software (Agilent Technologies, Santa Clara, CA, USA) was used f processing and averaging of several single spectra (details given in print outs). MS (ESI, positive ions) MS (ESI, negative ions) F soft ionisation techniques relative (!) intensities in the spectra should not be cited (exception: MS n spectra) because they are not reproducible in substance mixtures and on different MS instruments. If the isotopic cluster of a compound shall be cited as a proof f the elemental composition of a special compound, relative ion abundances have to be given as values (better) the cluster may be depicted in comparison with the calculated isotopic distribution. example: Intens. x104 1.25 2219.53 [2M + H] + = 2218.6 1.00 0.75 2218.57 2220.46 C 136 H 216 N 8 O 16 + H + 0.50 2221.46 0.25 2222.49 2223.51 0.00 2216 2218 2220 2222 2224 2226 2228 m/z Mass x: m/z of the pseudomolecular ion M x: number of the compound it s fmula (C xh yo z)

- 5-4. EI Mass spectrometry on the Autospec X EI mass spectra were recded using an Autospec X magnetic sect mass spectrometer with EBE geometry (Vacuum Generats, Manchester, UK) equipped with a standard EI source. Samples were introduced by push rod in aluminium crucibles if not otherwise noted. Ions were accelerated by 8 kv in EI mode. The spectra shown here are recded and processed with the OPUS software (V3.6, Micromass 1998) by the accumulation and averaging of several single spectra. Exact mass measurements were perfmed in the high resolution mode with PFK as internal standard. Centroided spectra were used to determine the mass accuracy. MS (EI, 70eV) m/z (%) = P (int) [Parent] +, F 1 (int) [Fragment 1] +, F 2 (int) [Fragment 2] +,... M x: number of the compound it s fmula (C xh yo z) P x: m/z of the parent ion F x: m/z of the fragment ion

- 6-5. ESI and MALDI spectra on the Synapt G2Si (Q-IMS-TOF MS) MALDI nano-esi experiments are perfmed using a Q-IMS-TOF mass spectrometer Synapt G2Si (Waters, Manchester, UK) in resolution mode, interfaced to a MALDI nano-esi ion source. Nitrogen serves both as the nebulizer gas and the dry gas f nano-esi. Nitrogen is generated by a nitrogen generat NGM 11. Helium 5.0 is used as buffer gas in the IMS entry cell, nitrogen 5.0 is used f IMS separations. Argon serves as collision gas f MS/MS experiments. 1,3-dicyanobenzene is used as electron transfer reagent in ETD experiments. The MALDI source is equipped with a 2.5 khz solid state laser at a wavelength of 355 nm. MALDI samples are mixed on a polished steel target with 1 µl of matrix solution (either 50 mg/ml 2,5-DHB in 50% ACN, 0.1% TFA saturated DCTB in methanol 10 mg/ml CHCA in 50% ACN, 50% ethanol with 0.1% TFA). ESI samples are introduced by static nano-esi using in-house pulled glass emitters. The Instrument Default Calibration was used f calibrating the mass axis. The mass axis was externally calibrated with (PEG red phosphous 1 ) as calibration standard on the same target. (use f MALDI experiments!) The mass axis was externally calibrated with fragment ions of GluFib as calibration standard. (use f nano-esi experiments!) The mass axis was internally calibrated with the doubly protonated GluFib ion as internal calibration standard. (use f nano-lc/ nano-esi experiments!) Scan accumulation and data processing was perfmed with MassLynx 4.1 (Waters, Manchester, UK) on a PC Wkstation. The spectra shown here were generated by the accumulation and averaging of several single spectra (as given in print outs). Determination of exact masses were perfmed using centroided data. Drift spectra were visualized and selected with DriftScope v2.8. MS (ESI, positive ions) MS (ESI, negative ions) MS/MS (ESI, P 1 (m/z XXX), positive ions) m/z (%) = P 1 [precurs] +, D 1 (int) [daughter 1] +, D 2 (int) [daughter 2] +,... F soft ionisation techniques relative (!) intensities in the spectra should not be cited (exception: MS n spectra) because they are not reproducible in substance mixtures and on different MS instruments. If the isotopic cluster of a compound shall be cited as a proof f the elemental composition of a special compound, relative ion abundances have to be given as values (better) the cluster may be depicted in comparison with the calculated isotopic distribution. (Compare example shown with Esquire 3000) F details on nano-lc/ nano-ms experiments (proteomics) refer to the operat. Lit.: 1 Sladkova, K., Houska, J., Havel, J. Rapid Comm. Mass Spectrom. 2009, 19, 3114-3118

- 7-6. HPLC/TLC ESI mass spectrometry on the ZQ2000 ESI mass spectra are recded using a ZQ2000 single quadrupole mass spectrometer (Waters, Manchester, UK) equipped with a ESI source, operating with a spray voltage of 3.5 kv. Nitrogen served both as the nebulizer gas and the dry gas and is generated by a nitrogen generat NGM 11. The mass axis was externally calibrated with ESI-L Tuning Mix (Agilent Technologies, Santa Clara, CA, USA) as calibration standard. HPLC: Samples are introduced with a AllianceHT 2795 HPLC system consisting of an autosampler, degasser, binary pump and 996 photodiode array detect (Waters, Manchester, UK) using a C8 Symmetry column (length: 100 mm, diameter: 2.1 mm, particle size: 3,5 µm) with a gradient (in 10 min from 5% B to 95% B, back to 5% B in 0.2 min, total run time 25 min) at a flow rate of 400 µl/min. HPLC solvent A consists of water and 0.1% fmic acid, solvent B of acetonitrile and 0.1% fmic acid. UV spectra are recded in the range from 190 nm to 800 nm. TLC: Samples are introduced using an in-house built TLC interface 1,2, operated with a Hitachi L-6000 LC pump (isopropanol, flow rate 400 µl/min) Scan accumulation and data processing was perfmed with MassLynx 4.1 (Waters, Manchester, UK) on a PC Wkstation. The spectra shown here were generated by the accumulation and averaging of several single spectra (as given in print outs). MS (ESI, positive ions) MS (ESI, negative ions) F soft ionisation techniques relative (!) intensities in the spectra should not be cited (exception: MS n spectra) because they are not reproducible in substance mixtures and on different MS instruments. If the isotopic cluster of a compound shall be cited as a proof f the elemental composition of a special compound, relative ion abundances have to be given as values (better) the cluster may be depicted in comparison with the calculated isotopic distribution. example: Intens. x104 1.25 2219.53 [2M + H] + = 2218.6 1.00 0.75 2218.57 2220.46 C 136 H 216 N 8 O 16 + H + 0.50 2221.46 0.25 2222.49 2223.51 0.00 2216 2218 2220 2222 2224 2226 2228 m/z Mass x: m/z of the pseudomolecular ion M x: number of the compound it s fmula (C xh yo z) 1 Luftmann, H Analytical and Bioanalytical Chemistry 2004, 378, 964-968 2 https://www.uni-muenster.de/imperia/md/content/ganisch_chemisches_institut2/massenspektrometrie/dgmshl.pdf

- 8-7. GC/MS on the Varian Saturn II EI/CI GC/MS spectra were recded using an Varian Saturn II GS/MS mass spectrometer equipped with an ion trap used with EI (70 ev) CI with internal ionization. The spectra shown here are recded and processed with the Varian Saturn II Software Version 5.2 by the accumulation and averaging of several single spectra f each GC peak using background subtraction. The GC used a 25 m silica capillary column HP 5 MS (0.2 mm ID, 0.33 µm film) 1. MS (EI, 70eV) m/z (%) = P (int) [Parent] +, F 1 (int) [Fragment 1] +, F 2 (int) [Fragment 2] +,... M x: number of the compound it s fmula (C xh yo z) P x: m/z of the parent ion F x: m/z of the fragment ion 1 Please ask a GCMS operat f the actual column your samples have been separated with!