University of Groningen. Technology in practice Lexmond, Anne

Similar documents
Citation for published version (APA): Westerman, E. M. (2009). Studies on antibiotic aerosols for inhalation in cystic fibrosis s.n.

Equivalence Evaluation of Valved Holding Chambers (VHCs) with Albuterol Pressurized Metered Dose Inhaler (pmdi)

Understanding cascade impaction and its importance for inhaler testing

COMPARISON OF THE RESPIRABLE FRACTION FROM THREE DIFERENT DPI DEVICES

Caption: The equipment required for testing Fluticasone Propionate (FP) Inhalation Powder in line with a new product-specific monograph (USP36-NF31).

Characterizing the Performance of Metered Dose Inhalers with Add-On Devices: New Methods For Clinically Relevant Testing

Citation for published version (APA): Koning, J. P. D. (2001). Dry powder inhalation: technical and physiological aspects, prescribing and use s.n.

Inhalation Product Research at FDA

University of Groningen. BNP and NT-proBNP in heart failure Hogenhuis, Jochem

Go With the Flow REGULATORY LANDSCAPE. Mark Copley at Copley Scientific

Effect of Interval Between Actuations of Albuterol Hydrofluoroalkane Pressurized Metered-Dose Inhalers on Their Aerosol Characteristics

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

IMPROVING THE REALISM AND RELEVANCE OF MOUTH-THROAT MODELS FOR INHALED PRODUCT TESTING

Citation for published version (APA): Weert, E. V. (2007). Cancer rehabilitation: effects and mechanisms s.n.

IVIVC in Pediatric OIPs

Assessing the role of breathing simulators in OIP testing

University of Groningen. Optimisation of dry powder inhalation Boer, Anne Haaije de

Respiratory Therapy. Medical/Scientific/General Background

How to use your QVAR RediHaler (beclomethasone dipropionate)

Dry Powder Inhaler. Developing an Efficient. 3M Conix DPI. White Paper / Spring Proven Solutions that Enable Your Success

21/03/2011 AEROSOL DEPOSITION AND THE ASSESSMENT OF PULMONARY DRUG DELIVERY. Fundamentals of aerosols

Perceptual reasons for resistance to change in the emergency department use of holding chambers for children with asthma

Device Design Similarity

PET Imaging of Mild Traumatic Brain Injury and Whiplash Associated Disorder Vállez García, David

CLINICAL RELEVANCE OF IN VITRO PARTICLE SIZING DATA. Steve Newman, PhD Nottingham, UK November 2006

CAPSULE-BASED DRY POWDER INHALERS, AN OPTIMAL SOLUTION FOR DIFFERENT INSPIRATIONAL RATES

University of Groningen. Symptomatic and asymptomatic airway hyperresponsiveness Jansen, Desiree

University of Groningen. Real-world influenza vaccine effectiveness Darvishian, Maryam

Inhalation devices, proper technique and cleaning

University of Groningen. Diminished ovarian reserve and adverse reproductive outcomes de Carvalho Honorato, Talita

Improving quality of care for patients with ovarian and endometrial cancer Eggink, Florine

Pulmonary deposition of inhaled drugs

Major role of the extracellular matrix in airway smooth muscle phenotype plasticity Dekkers, Bart

Using an Inhaler and Nebulizer

Delay Between Actuation and Shaking of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler

AEROSOL THERAPY: THE PRACTICALITIES

EPAG Sponsored Workshop on Abbreviated Impactor Measurement (AIM) and Efficient Data Analysis (EDA) Concepts in Inhaler Testing. Overview of AIM EDA

THE NEW ZEALAND MEDICAL JOURNAL

Use of Math Modelling to Understand Delivery of Biopharmaceutical Molecules to the Lung

Delivery of Iloprost Inhalation Solution With the HaloLite, Prodose, and I-neb Adaptive Aerosol Delivery Systems: An In Vitro Study

Appendix M: Device Technique

Q. What are metered-dose inhalers? A. These are devices that dispense medicines directly into the lungs, in the form of a mist or aerosol in a

Pharmacoeconomic analysis of proton pump inhibitor therapy and interventions to control Helicobacter pylori infection Klok, Rogier Martijn

Citation for published version (APA): Otten, M. P. T. (2011). Oral Biofilm as a Reservoir for Antimicrobials Groningen: University of Groningen

MDI. Recommended Equipment

Brain-inspired computer vision with applications to pattern recognition and computer-aided diagnosis of glaucoma Guo, Jiapan

Patricia KP Burnell Inhalation Product Development

Patient. Device Clinician. Safety & efficacy

It is recommended that a mask and protective eyewear be worn when providing care to a patient with a cough

University of Groningen. Optimisation of dry powder inhalation de Boer, Anne

COMMITTEE FOR MEDICINAL PRODUCTS FOR HUMAN USE (CHMP) GUIDELINE ON THE PHARMACEUTICAL QUALITY OF INHALATION AND NASAL PRODUCTS

ASTHMA POLICY KYABRAM P-12 COLLEGE

University of Groningen. The Economics of assisted reproduction Connolly, Mark Patrick

Misty Max 10 nebulizer

University of Groningen. Acantholysis in pemphigus van der Wier, Gerda

Goal-oriented hemodynamic treatment in high-risk surgical patients Sonneveld, Johan Pieter Cornelis

Invacare Aerosol Products. Stratos Aerosol Compressors Nebulizers Asthma Management

Respiratory. Martin Jetzer DDL27 Edinburgh December 2016

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

University of Groningen. Non-alcoholic fatty liver disease Sheedfar, Fareeba

NEBULIZERS, METERED DOSE INHALERS, AND DRY POWDER INHALERS

In vitro studies on the cytoprotective properties of Carbon monoxide releasing molecules and N-acyl dopamine derivatives Stamellou, Eleni

Development of patient centered management of asthma and COPD in primary care Metting, Esther

GMMMG Asthma Formulary Inhaler Options August 2017

How can I benefit most from my COPD medications?

OPTIMISING ANALYTICAL STRATEGIES FOR THE DEMONSTRATION OF BIOEQUIVALENCE IN A GENERIC NEBULISER

COPD Device Workshop. Summary. Role of inhaler device in COPD. Why use inhaler device in COPD?

Metered Dose Inhalers with Valved Holding Chamber: A Pediatric Hospital Experience

Insulin sensitivity of hepatic glucose and lipid metabolism in animal models of hepatic steatosis Grefhorst, Aldo

University of Groningen

University of Groningen

The influence of lactose particle size on dry powder inhalation performance

University of Groningen. Carcinoembryonic Antigen (CEA) in colorectal cancer follow-up Verberne, Charlotte

PREMIXES FOR MEDICATED FEEDING STUFFS FOR VETERINARY USE. Praeadmixta ad alimenta medicata ad usum veterinarium. Effervescent powders

Role of multidrug resistance-associated protein 1 in airway epithelium van der Deen, Margaretha

Sorting and trafficking of proteins in oligodendrocytes during myelin membrane biogenesis Klunder, Lammert

Testing Inhaled Generics

Tunable Hydrophobicity in DNA Micelles Anaya, Milena; Kwak, Minseok; Musser, Andrew J.; Muellen, Klaus; Herrmann, Andreas; Müllen, Klaus

University of Groningen. Leven na een beroerte Loor, Henriëtte Ina

The role of the general practitioner in the care for patients with colorectal cancer Brandenbarg, Daan

Year in review. Vit Perlik Director of Regulatory Science and Clinical Development

Beclometasone dipropionate (BDP) Prophylactic management of mild, moderate or severe asthma in adults

The effect of different coating materials on the prevention of powder bounce in the next generation impactor

An update on inhalation devices

University of Groningen. ADHD and atopic diseases van der Schans, Jurjen

University of Groningen. The Groningen Identity Development Scale (GIDS) Kunnen, Elske

2008 IPAC-RS Conference Doing the Right Thing Science, Quality and Patient Focus

University of Groningen. Soft tissue development in the esthetic zone Patil, Ratnadeep Chandrakant

University of Groningen. Transdermal delivery of anticholinergic bronchodilators Bosman, Ingrid Jolanda

8/13/11. RSPT 1410 Humidity & Aerosol Therapy Part 3. Humidification Equipment. Aerosol Therapy

University of Groningen. Medication use for acute coronary syndrome in Vietnam Nguyen, Thang

Apoptosis in (pre-) malignant lesions in the gastro-intestinal tract Woude, Christien Janneke van der

Inhalation Therapy. Inhalation Therapy

In Vitro Evaluation of Positive Expiratory Pressure Devices Attached to Nebulizers

The role of the general practitioner during treatment and follow-up of patients with breast cancer Roorda-Lukkien, Carriene

Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:

Cascade Impactor Study Comparing the Amsino OneMask Oxygen Mask and Predicate Mask from Hudson RCI on a Human Model

University of Groningen. Physical activity and cognition in children van der Niet, Anneke Gerarda

Ventamol CFC-Free 100 micrograms, Pressurised Inhalation, Suspension (Salbutamol)

Pathophysiology and management of hemostatic alterations in cirrhosis and liver transplantation Arshad, Freeha

Transcription:

University of Groningen Technology in practice Lexmond, Anne IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below. Document Version Publisher's PDF, also known as Version of record Publication date: 2014 Link to publication in University of Groningen/UMCG research database Citation for published version (APA): Lexmond, A. (2014). Technology in practice: The importance of matching purpose, patient, and product in pulmonary aerosol delivery. [S.l.]: [S.n.]. Copyright Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons). Take-down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum. Download date: 04-04-2019

CHAPTER 6 THE EFFECT OF A DISPOSABLE EXTENSION MOUTHPIECE ON THE AEROSOL FROM THE REDIHALER Anne J. Lexmond, Paul Hagedoorn, T.Y. Jerôme Appeldoorn, Tamira A.B. Jansman, Henderik W. Frijlink, Anne H. de Boer

Chapter 6 ABSTRACT To allow the use of the salbutamol Redihaler by multiple patients as reliever medication during challenge tests in the clinic, a disposable extension mouthpiece with a one-way valve has been developed to prevent exhalation into the device. We investigated whether this mouthpiece affects the aerosol from the Redihaler in terms of its delivered dose and particle size distribution. Single shot impinger measurements and cascade impaction analyses were performed at three different flow rates: 30, 60, and 90 L/min. We found that the extension mouthpiece reduces the delivered dose by about 85% at 60 90 L/min and by 94% at 30 L/min, leading to the conclusion that 30 L/min is insufficient to open the mouthpiece s valve completely. Furthermore, and as expected, the external piece selectively retains the larger particles from the aerosol, mainly those larger than 3 µm. Although the delivered dose from the Redihaler is greatly reduced by the disposable mouthpiece, comparable results can be found when a standard pressurised metered dose inhaler is used with a valved holding chamber. Therefore, in spite of the high losses, we consider the Redihaler with disposable extension mouthpiece suitable as alternative to the standard reliever medication (pmdi with a VHC), provided that the patient is instructed to inhale moderately forceful to allow proper opening of the valve in the mouthpiece. 130

Disposable extension mouthpiece for the Redihaler INTRODUCTION Bronchial challenge tests are widely used for the assessment of bronchial hyperresponsiveness and diagnosis of asthma. Since it is the actual aim of a bronchial challenge test to induce bronchoconstriction, safety is a very important aspect of the test. In order to counteract the bronchoconstriction when necessary (or when the test is completed), reliever medication should be readily available (35). Most often, the bronchodilator salbutamol is given to relieve the mild constriction that usually results from the challenge test. For the salbutamol administration, a pressurised metered dose inhaler (pmdi) combined with a valved holding chamber (VHC) is generally used, which is equipped with a disposable mouthpiece to allow use of the same inhaler by multiple patients. Standard pmdis are actuated by pressing down the canister. Upon actuation, the salbutamol dose is fired into the VHC, from which it can be inhaled in multiple breaths by the patient. In contrast to standard pmdis, the Redihaler pmdi is breath-actuated, i.e. the dose is fired upon inhalation through the pmdi by the patient. This feature may significantly increase both the treatment s efficacy and convenience for use at home, since good actuation-inhalation coordination or the use of a VHC is no longer necessary. For use in the clinic, a disposable patient interface is required, to which end the manufacturer of the Redihaler has developed a disposable mouthpiece. Although in everyday language referred to as a filter mouthpiece by the supplier, this extension part actually contains a one-way valve and not a filter. The valve is meant to prevent breathing into the Redihaler, which would render it unsuitable for use by other patients. The aim of this study was to determine whether the Redihaler with the extension mouthpiece can be a suitable alternative to a standard pmdi with VHC for the delivery of reliever salbutamol in the clinic. We investigated how and to what extent the disposable extension piece affects the performance of the Redihaler by measuring the delivered dose and particle size distribution in the aerosol. 131

Chapter 6 MATERIALS AND METHODS Materials Redihaler salbutamol 100 µm and disposable extension mouthpieces from TEVA Pharmaceuticals (Haarlem, The Netherlands) were used in the study. Salbutamol sulphate (Ph. Eur.), provided by DMV Fonterra Excipients (Goch, Germany), was used for preparing a calibration curve for UV analysis. Single shot impinger measurements The single shot impinger is a centrifugal wet particle collector that can be used to determine the dose that is emitted from inhalation devices. Delivered doses from the Redihaler with and without extension mouthpiece were determined at 30, 60, and 90 L/min. In accordance with the European Pharmacopoeia, 4 L of air was drawn through the device to collect one dose, for which 8, 4, and 2.7 s were required at 30, 60, and 90 L/min respectively. The single shot impinger was filled with 10 ml of water and ten doses were collected per measurement. Two series of measurements were conducted, consisting of one measurement without the extension mouthpiece and subsequently five measurements with the extension mouthpiece. Salbutamol deposition in the impinger was determined by UV spectroscopy at 225 nm. Cascade impaction measurements Cascade impaction measurements were performed with the Next Generation Impactor (NGI: Copley Scientific, UK). The NGI was cooled to approximately 5 C in the refrigerator prior to the measurements in accordance with the procedure recommended by Berg et al. for wet aerosols (264). This study also describes that the stage cups of the NGI can be used uncoated, since moist particles do not bounce off once they impact on the surface. The measurements were performed in duplicate at 30, 60, and 90 L/min. Equal to the single shot impinger measurements, 4 L of air was drawn through the device to collect each dose (at 8, 4, and 2.7 s measuring time respectively). Ten and twenty doses were collected per measurement without and with the extension mouthpiece respectively. Salbutamol deposition in the induction port and stage cups was determined by UV spectroscopy at 225 nm. 132

Disposable extension mouthpiece for the Redihaler Data presentation and analysis The delivered doses without extension mouthpiece are expressed as percentage of the label claim (100 µg). To allow for comparison of the effect of the extension mouthpiece on the delivered dose per flow rate, the delivered doses found with the extension mouthpiece were calculated as percentage of the delivered dose without mouthpiece measured at the beginning of the series. Unpaired two-sided Student s t tests were performed to compare the delivered doses at the different flow rates. Probability values (p) < 0.05 were considered statistically significant. Cumulative mass fractions deposited on the NGI stages were expressed as percentage of the label claim and plotted as function of the stage cut-off values corresponding with the flow rates adjusted. The relationships obtained were used to calculate sub fractions <1, 1 3, and 3 5 µm respectively by linear interpolation. RESULTS AND DISCUSSION Delivered dose with and without extension mouthpiece Although the inhaler was handled according to the instructions (vigorously shaken before use and discarding of the first doses), the delivered dose from the Redihaler without extension mouthpiece varied from 65 to 95% for the individual measurements. On average, we found delivered doses of 76, 70, and 95% at 30, 60, and 90 L/ min, respectively, which suggests that there is no clear relationship between flow rate and delivered dose. However, there appeared to be an inverse relation between the delivered dose and the number of doses left in the inhaler, but this was not systematically investigated in this study. Figure 6-1 shows the delivered dose from the Redihaler when the extension mouthpiece is used as percentage of the delivered dose without mouthpiece. A strong reduction was found at all flow rates, which was visually verified by deposition of powder on the inside of the extension mouthpiece. The reduction was most pronounced at 30 L/min, at which only 6% of the delivered dose relative to the dose without extension piece was recovered. This recovery was significantly lower than those at 60 and 90 L/ min (p < 0.0001). Between the two highest flow rates, no significant difference was found due to the large variation in the results (p = 0.069). 133

Chapter 6 20 Delivered dose (%) 16 12 8 4 0 30 60 90 Flow rate (L/min) Figure 6-1. The delivered dose from the Redihaler when the extension mouthpiece is used expressed as percentage of the delivered dose without extension mouthpiece. The lower delivered dose found at a flow rate of 30 L/min can be attributed to the design of the extension mouthpiece. The valve within the mouthpiece appears to require a certain minimal airflow rate to open sufficiently wide for aerosol passage. A flow rate of 30 L/min does not suffice in this respect. Since no difference in delivered dose was found between 60 and 90 L/min, the threshold flow rate for complete opening the valve completely is expected to be anywhere between 30 and 60 L/min, but even after complete opening a substantial portion of the delivered dose is retained in the extension piece. Aerodynamic size distribution of the aerosol Figure 6-2 shows the fine particle fractions < 5 µm (FPF) of the aerosols with and without extension divided into three subclasses: < 1 µm, 1 3 µm, and 3 5 µm. At all flow rates, the diminishing effect of the extension mouthpiece on the FPF is apparent. Without extension mouthpiece, FPFs were 45, 48, and 37% of the label claim at 30, 60, and 90 L/min respectively. Comparing these values to the delivered doses found with the impinger, it can be seen that maximally 50% of the delivered dose is within the desired size range for good lung deposition. Remarkable is the lower fraction deposited at 90 L/min using the NGI compared to the impinger measurements. A reason for this might be that the higher airflow rate led to more turbulence in the NGI, thereby resulting in reduced deposition on the stages (265). 134

Disposable extension mouthpiece for the Redihaler Fraction of label claim (%) 35 30 25 20 15 10 5 0 without filter with filter <1 1-3 3-5 <1 1-3 3-5 <1 1-3 3-5 30 L/min 60 L/min 90 L/min Particle diameter (µm) Figure 6-2. The fine particle fractions of the aerosols from the Redihaler with and without extension mouthpiece, expressed as percentage of the label claim (100 µg). The FPFs with extension mouthpiece were 7, 10, and 13% of the label claim at 30, 60, and 90 L/min respectively. These values are comparable to the delivered doses found with the impinger. Additionally, Figure 6-2 shows that the extension piece selectively retains the largest particles. This finding can also be explained by the design of the extension piece. The particles emitted from the inhaler have to follow the change in airflow direction when they pass through the valve. The larger the particles are, the larger is their inertia, and the more likely they impact on the valve. Implications of using the extension mouthpiece We have shown that using the extension mouthpiece greatly reduces the dose that is delivered by the Redihaler. Especially at a flow rate of 30 L/min, only a very limited fraction of the aerosol was delivered from the mouthpiece. The Redihaler requires a flow rate of 20 L/min to fire its dose and the manufacturer of the Redihaler advises to inhale slowly through the device (266). When operated without extension mouthpiece, this advice should be heeded, since the higher the flow rate is, the more deposition occurs in the mouth and throat region. However, when the extension mouthpiece is used, inhaling with such low flow rates leads to insufficient opening of the valve, and hence, to insufficient release of the aerosol. In addition, the disposable mouthpiece retains the aerosol selectively as only a small 135

Chapter 6 fraction larger than 3 µm was found to pass through the valve. Blocking the particles larger than 5 µm can be considered a useful feature of the extension mouthpiece, since these particles would otherwise deposit mainly in the mouth and throat and are therefore not desired. In contrast, the fraction 3 5 µm is highly wanted because this fraction is mainly deposited in the conducting airways, where constriction of the smooth muscle tissue is the main cause for the bronchoconstriction during a bronchial challenge test. Retaining this fraction may thus render the Redihaler less effective in counteracting breathlessness after challenge. It should be noted that the Redihaler in combination with the extension mouthpiece is offered as an alternative to a standard pmdi in combination with a VHC. Hence, for its effectiveness it should be compared to this combination rather than to a pmdi alone. In terms of clinical effectiveness, no difference was found between four times 100 µg salbutamol administered by the combination of Redihaler and extension mouthpiece or Ventolin and Nebuhaler with a disposable valve (267). The comparable response to the two treatments may on the one hand be the result of the abundant dose of 400 µg, of which a sufficiently large fraction within the desired size range remains for deposition in the target area for patients to recover to baseline. On the other hand, VHCs are also known to retain a significant part of the aerosol, which depending on the material of which the VHC is made and the environmental conditions can become as high as 90 95% too (268,269). CONCLUSION Based on the combined results of this in vitro characterisation study with the clinical response data of Ruberg et al. (267), the salbutamol Redihaler (100 µg) with extension mouthpiece appears to be an suitable alternative to the standard rescue treatment after bronchial challenge, but only if the patient is instructed to inhale moderately forceful to allow complete opening of the valve. 136

Disposable extension mouthpiece for the Redihaler 137