Similar documents
Efficient Dosimetry for Proton Therapy

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Online Care, Online Control, Online Confidence

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

iba-dosimetry.com INTEGRATED QUALITY ASSURANCE Solution Overview

Elekta Synergy Digital accelerator for advanced IGRT

Subject: Image-Guided Radiation Therapy

Soft tissue biopsy needles

XSIGHT LUNG TRACKING SYSTEM

Soft tissue biopsy needles

Application of Implanted Markers in Proton Therapy. Course Outline. McLaren Proton Therapy Center Karmanos Cancer Institute McLaren - Flint

MRI Applications in Radiation Oncology:

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

MRI to fit your planning. Philips Panorama HFO Oncology Configuration

Gold Anchor enables safe reach to inner organs

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Venezia Advanced Gynecological Applicator Reaching beyond

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Blue Phantom 2 with. Built for the next generation. Introduction Introduction Introduction Introtro Intro Intro

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

Endobronchial Ultrasound in the Diagnosis & Staging of Lung Cancer

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS

Introducing Wollongong Diagnostics Corrimal

Pre-treatment verification for IMRT / IGRT and Rotational therapy

Motion gating and tracking techniques: overview and recent developments

Blue Phantom 2 with OmniPro-Accept (V 7) Fastest, Most Accurate and Most Reliable Solution for Relative Dosimetry

I. Equipments for external beam radiotherapy

Precisely Maximize Dose, side effects, Patient

Overview of Advanced Techniques in Radiation Therapy

Stability of endoscopic ultrasound-guided fiducial marker placement for esophageal cancer target delineation and image-guided radiation therapy

CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort

For a legacy that lives large: Think Big. Philips CT Big Bore. Computed tomography

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Clinical Education A comprehensive and specific training program. carry out effective treatments from day one

Image Guided Proton Therapy and Treatment Adaptation

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

02 CyberKnife: Treatment Delivery

Image Fusion, Contouring, and Margins in SRS

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Andrew K. Lee, MD, MPH Associate Professor Department tof fradiation Oncology M.D. Anderson Cancer Center

Educational workshop: Real-time Image-Guided HDR Brachytherapy for Prostate Cancer

Prostate Cancer. What is prostate cancer?

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Credentialing for the Use of IGRT in Clinical Trials

The future of radiation therapy. Safe and innovative options, including the CyberKnife System

Changing Paradigms in Radiotherapy

Acknowledgements. QA Concerns in MR Brachytherapy. Learning Objectives. Traditional T&O. Traditional Summary. Dose calculation 3/7/2015

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

Technological Advances in Radiotherapy for the Treatment of Localized Prostate Cancer - A Systematic Review

Prostate Cancer Treatment

Radiation Therapy for Prostate Cancer. Resident Dept of Urology General Surgery Grand Round November 24, 2008

Solutions

Elekta Infinity Digital accelerator for advanced treatments

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies

UNDERSTANDING SERIES LUNG CANCER BIOPSIES LungCancerAlliance.org

New Radiation Treatment Modalities in the Treatment of Lung Cancer

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

CAPITAL HEALTH CENTER FOR ONCOLOGY. capitalhealth.org/oncology

Prostate Cancer. What is prostate cancer?

Patient and Linac QA - present and the future

slide courtesy of Daniel Low Motion management Sofie Ceberg PhD, Medical Physicist Skåne University Hospital, Lund

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

The High-End Solution for Real-Time Patient Tracking

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

E x t r a c o r p o r e a l Shockwav e Lithotripsy

ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER

What is the CyberKnife System?

Prostate Cancer Appraisal Addendum: Stereotactic Body Radiation Therapy (SBRT)

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

Elekta - a partner and world-leading supplier

Modern Interstitial GYN Brachytherapy. Conflicts: 8/3/2016. Modern Interstitial GYN Brachytherapy. 1. Use of MR

Outline - MRI - CT - US. - Combinations of imaging modalities for treatment planning

LOGIQ E9 with XDclear

Strengthening the weakest link: improving tumour definition

Navigate Complex Interventions at Every Turn

Has radiotherapy the potential being focal?

LOGIQ E9 with XDclear

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Surgeons and New York Presbyterian Hospital. New York, NY, USA

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Electromagnetic Navigation Bronchoscopy. Populations Interventions Comparators Outcomes Individuals: With suspicious pulmonary lesion(s)

Performance Evaluation of Calypso (R) 4D Localization and Kilovoltage Image Guidance Systems for Interfraction Motion Management of Prostate Patients

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

02 CyberKnife: System Overview

The next generation of prostate care

Introducing the TrueBeam STx system with Novalis Radiosurgery.

Electromagnetic Navigation Bronchoscopy

Transcription:

Flexible soft tissue Marker for IGRT, SBRT & PT See it! Trust it! Treat it! THORACIC GI GU CERVIX

See it! Improved Marker Visibility by Design Conventional gold seeds VISICOIL linear fiducial marker 1) Visibility during Marker Placement More accurate marker placement: With TRUS / EUS / EBUS through highly echogenic VISICOIL surface 2) Better Visibility for Better Target Definition VISICOIL aids in accurate target delineation particularly when tightening margins. CT: Reduced artifact for improved contouring MRI: Compatible and visible with MRI for planning & fusion 1) 3) Better Visibility for More Precise Image-Guided Patient Setup Linear profile: Non-anatomic structure provides easy detection Flexible marker design: Conforms with tissue motion Conventional Seed VISICOIL VISICOIL is Compatible with all Common Imaging Modalities Ultrasound Prostate CBCT Prostate X-ray Lung MRI Prostate PET/CT Esophagus MV Prostate 1) Jonsson JH, Garpebring A, Karlsson MG, et al. Internal fiducial markers and susceptibility effects in MRI-simulation and measurement of spatial accuracy. Int J Radiat Oncol Biol Phys 2012;1612-1618. IBA DOSIMETRY // 2

Trust it! VISICOIL Ideal for IGRT, SBRT, Proton Therapy & Robotic Radiosurgery NON-MIGRATING DESIGN Helical shape increases surface area to anchor VISICOIL into tissue 1) LINEAR MARKER = MORE INFORMATION, LESS NEEDLES FLEXIBLE MARKER ABSORBS TISSUE MOTION THINNER NEEDLE = IMPROVED PATIENT COMFORT Ideal for use with 22g FNA OVER 75,000 PATIENTS TREATED WITH VISICOIL The VISICOIL fiducials did not migrate and are easily identified on kilovoltage fluoroscopy using modern on-board imaging. Creach KM, Azar R, Bradley JD, et al. Tumor localization with Visicoil ultra-thin fiducials for abdominal radiation therapy. Int J Radiat Oncol Biol Phys 2009;75:S589 In the current study, fiducials implanted into a lung tumor showed no substantial migration during the entire course of treatment. Kupelian PA, Forbes A, Willoughby TR, et al. Implantation and stability of metallic fiducials within pulmonary lesions. Int J Radiat Oncol Biol Phys 2007;777-785. The type of fiducial marker that we are employing has several advantages. One is the flexibility of the coiled marker. The other is the length. Together these characteristics allow ease of radial placement. We feel the coiled design lessens potential for migration. McGuire FR, Kerley JM, Ochran T, et al. Radiotherapy monitoring device implantation into peripheral lung cancers: A therapeutic utility of electromagnetic navigational bronchoscopy. J Broncol 2007;189-192. IBA DOSIMETRY // 3

Treat it! VISICOIL s Proven Efficiency and Ease of Use Enables you to Focus on your Patients Faster, Easier and Safer Marker Placement Less needles = Less measuring = Faster implantations* Pre-loaded needles or loose VISICOIL = Easy to use VISICOIL products are stocked = Same day shipment available *see implantation video at YouTube (ibadosimetry) Patient Setup Efficiency & Reliability Faster Setup through unambiguous marker detection VISICOIL is indicated for use to radiographically mark soft tissue for future therapeutic procedures VISICOIL Support Dedicated team specializing in fiducial markers Local availability with vast experience Support your team through every step including placement and use As a courtesy, our partner Revenue Cycle is available for any reimbursement questions* EDUCATION TRAINING SUPPORT NETWORKING *Revenue Cycle is only available in the United States. IBA DOSIMETRY // 4

Innovations Designed for Interventional Radiology Approved by Interventional Radiology VISICOIL s 0.50mm and 0.35mm markers are now available pre-loaded in 21 and 22 gauge 15cm needles. Ideal for Interventional Radiology allowing for easier access with improved patient comfort and safety due to the smaller needle size. Implantation Safety Reduced risk of pneumothorax Reduced risk of bleeding / edema Improved safety and comfort for patient Implantation Efficiency Shorter 15cm needle ideal for standard bore CT Steerable needle aids in accurate marker placement Centimeter marks for depth placement VISICOIL Needle Size 17g 21g 22g VISICOIL is also available Pre-Loaded in new 21g and 22g x 15cm needles for increased safety. These are designed for Interventional Radiology. NEW VISICOIL 0.5mm 21g Needle 15cm NEW VISICOIL 0.35mm 22g Needle 15cm VISICOIL can be loaded into both 19g and 22g FNA for EUS/EBUS/Bronchoscope placement. IBA DOSIMETRY // 5

What you see is what you treat! VISICOIL is the original flexible linear marker for use with today s most accurate image guided radiotherapy treatment plans. CONTACT DETAILS For more information or to order VISICOIL, please contact us: NORTH AMERICA LATIN AMERICA RadioMed Corporation 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133 Tel: +1 901 432 7202 Fax: +1 901 432 7206 Toll Free: 866 429 0922 E-mail: visicoil@iba-group.com EUROPE MIDDLE EAST AFRICA IBA Dosimetry GmbH Bahnhofstr. 5 90592 Schwarzenbruck, Germany Tel: +49 9128 607 0 Fax: +49 9128 607 10 E-mail: info@iba-dosimetry.com ASIA PACIFIC IBA Dosimetry Asia Pacific No. 6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP) Tel: +86 10 8080 9288 Fax: +86 10 8080 9299 E-mail: visicoil@iba-group.com IM-BR-E-VISICOIL-Rev.2-1014 IBA 2013 All rights reserved VISICOIL is a trademark of IBA Distribed by IBA Manufactured by RadioMed Corporation, an IBA Company VISICOIL.com