NEW SUBTRACTION ALGORITHMS FOR EVALUATION OF BREAST LESIONS ON DYNAMIC CONTRAST ENHANCED MR MAMMOGRAPHY

Similar documents
New subtraction algorithms for evaluation of lesions on dynamic contrast-enhanced MR mammography

A-005 US DIAGNOSIS OF NONPALPABLE BREAST LESIONS

Contrast-enhanced Breast MRI RSSA 2013

BI-RADS and Breast MRI. Kathy Borovicka, M.D. Thursday February 15, 2018

2017 Obesity Fact Sheet

Armed Forces Institute of Pathology.

MRI of Bucket-Handle Te a rs of the Meniscus of the Knee 1

Categorical Classification of Spiculated Mass on Breast MRI

Anyone can get breast cancer BREAST MRI BREAST CANCER. The incidence of getting breast cancer is 1:19 in Malaysia

Second-look ultrasonography for MRI-detected suspicious breast lesions in patients with breast cancer

Clinical Correlation of a New Practical MRI Method for Assessing Cervical Spinal Canal Compression

Radiologic and pathologic correlation of non-mass like breast lesions on US and MRI: Benign, high risk, versus malignant

Radiologic and pathologic correlation of non-mass like breast lesions on US and MRI: Benign, high risk, versus malignant

MR Imaging of Atherosclerotic Plaques

MRI of the Breast for the Detection and Assessment of the Size of Ductal Carcinoma in Situ

The Clinical Correlation of a New Practical MRI Method for Grading Cervical Neural Foraminal Stenosis Based on Oblique Sagittal Images

The role of apparent diffusion coefficient (ADC) and relative ADC in the evaluation of breast masses

US IN 411 LOCALIZATIONS OF NONPALPABLE BREAST LESIONS

Original Research JOURNAL OF MAGNETIC RESONANCE IMAGING 32: (2010)

Radiologic Findings of Mucocele-like Tumors of the breast: Can we differentiate pure benign from associated with high risk lesions?

Pitfalls and Limitations of Breast MRI. Susan Orel Roth, MD Professor of Radiology University of Pennsylvania

Papillary Tu m o rs of the Breast: US Findings

Can magnetic resonance imaging obviate the need for biopsy for microcalcifications?

3D Automated breast ultrasound (ABUS): pictorial review of applications and clinical utility.

Usefulness of magnetic resonance imaging-guided vacuum-assisted breast biopsy in Korean women: a pilot study

Breast MRI Update. Jeffrey C. Weinreb, MD, FACR Yale University School of Medicine

Direct Injection of Paraffin into the Breast: Mammographic, Sonographic, and MRI Features of Early Complications

Computerized Segmentation and Classification of Breast Lesions Using Perfusion Volume Fractions in Dynamic Contrast-enhanced MRI

MRI IN THE CHARACTERIZATION OF SEMINOMATOUS AND NONSEMINOMATOUS GERM CELL TUMORS OF THE TESTIS

Standard Breast Imaging Modalities. Lilian Wang, M.D. Breast Imaging Section Department of Radiology Northwestern Medicine

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Assessment of extent of disease: digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM)

Emerging Techniques in Breast Imaging: Contrast-Enhanced Mammography and Fast MRI

Cystic Hypersecretory Carcinoma of the Breast:

Procedia - Social and Behavioral Sciences 159 ( 2014 ) WCPCG 2014

Automated Breast Volume Scanner: 3D-Ultrasound of breast lesions

Automated Breast Volume Scanner: 3D-Ultrasound of breast lesions

Current Imaging Diagnosis of the Breast Tumors

EGIS BILIARY STENT. 1. Features & Benefits 2. Ordering information 3. References

Index. C Calcifications fat necrosis 1, 61 fat necrosis 4, 69 nipple/peri-areolar involvement 1, 165

Aims and objectives. Page 2 of 10

Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer

Observer Agreement Using the ACR Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, First Edition (2003)

Sensitivity and Specificity in Detection of Labral Tears with 3.0-T MRI of the Shoulder

Sonographic Differentiation of Thyroid Nodules With Eggshell Calcifications

Updates in Mammography. Dr. Yang Faridah A. Aziz Department of Biomedical Imaging University Malaya Medical Centre

Pharmacokinetic evaluation of DCIS

The Role of Diffusion-Weighted Imaging and the Apparent Diffusion Coefficient (ADC) Values for Breast Tumors

Inflammatory Breast Carcinoma: Mammographic, Ultrasonographic, MRI and Pathologic Findings

Value of the BI-RADS classification in MR-Mammography for diagnosis of benign and malignant breast tumors

Effect of intravenous contrast medium administration on prostate diffusion-weighted imaging

The 1 st Congress of Asian Society of Cardiovascular Imaging

Effects of Post Biopsy Digital Rectal Compression on Improving Prostate Cancer Staging Using Magnetic Resonance Imaging in Localized Prostate Cancer

Imaging in breast cancer. Mammography and Ultrasound Donya Farrokh.MD Radiologist Mashhad University of Medical Since

Taller-Than-Wide Sign of Thyroid Malignancy: Comparison Between Ultrasound and CT

BARC/2013/E/019 BARC/2013/E/019. AUDIT OF MAMMOGRAPHY PERFORMED IN OUR HOSPITAL by Surita Kantharia Medical Division

BREAST MRI. VASILIKI FILIPPI RADIOLOGIST CT MRI & PET/CT Departments Hygeia Hospital, Athens, Greece

Digital breast tomosynthesis (DBT) occult breast cancers: clinical, radiological and histopathological features.

Using Automated Breast Sonography as Part of a Multimodality Approach to Dense Breast Screening

Breast Sonographic Elastography Using an Advanced Breast Tissue- Specific Imaging Preset

Table 9: Vascularity and Hemorrhage

OPTO-ACOUSTIC BREAST IMAGING

Topic: Breast Duct Endoscopy (Ductoscopy) Date of Origin: May 4, Section: Medicine Last Reviewed Date: June 2013

ORIGINAL PAPER. Background parenchymal enhancement in preoperative breast MRI

MRI of breast implant: broken or not broken?

MRI BI-RADS: How to make it out?

Quality of life (QoL) in metastatic breast cancer patients with. maintenance paclitaxel plus gemcitabine (PG) chemotherapy:

BI-RADS MRI: A Primer

Ultrasonography. Methods. Brief Description. Indications. Device-related Prerequisites. Technical Requirements. Evaluation Criteria

Early Surgery in Asymptomatic Severe Aortic Stenosis Pros and Cons

Quantitative Analysis of the Facial Nerve Using Contrast-Enhanced Three Dimensional FLAIR-VISTA Imaging in Pediatric Bell s Palsy

Criteria of Malignancy. Evaluation Score

Vacuum-assisted breast biopsy using computer-aided 3.0 T- MRI guidance: diagnostic performance in 173 lesions

Clinical Utility of Actionable Genome Information in Precision Oncology Clinic

RADIOLOGIC EVALUATION OF BREAST CANCER

Breast Imaging & You

Conventional Galactography and MR Contrast Galactography for Diagnosing Nipple Discharge: Preliminary Results

Date of Preparation: December 8, 2017 A. GENERAL INFORMATION. 1. Name: Eun Sook KO Citizenship: Republic of Korea

Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report

Breast Imaging & You

Feasibility of MRI-guided large-core-needle biopsy of suspiscious breast lesions at 3T

ROLE OF CONTRAST ENHANCED MR ANGIOGRAPHY IN AORTIC COARCTATION

Over the recent decades, breast ultrasonography (US) has

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Immersion Ultrasonography of Excised Nonpalpable Breast Lesion Specimens after Ultrasound-Guided Needle Localization

Rate of Malignancy in MRI-Detected Probably Benign (BI-RADS 3) Lesions

Digital Breast Tomosynthesis from a first idea to clinical routine

RESEARCH ARTICLE. Woo Jung Choi, Joo Hee Cha*, Hak Hee Kim, Hee Jung Shin, Hyunji Kim, Eun Young Chae, Min Ji Hong. Abstract.

Diagnosis of Pseudoangiomatous Stromal Hyperplasia of the Breast: Ultrasonography Findings and Different Biopsy Methods

Radiologic Finding of Failed Percutaneous Vertebroplasty

Mammographic evaluation of palpable breast masses with pathological correlation: a tertiary care centre study in Nepal

Diagnostic benefits of ultrasound-guided. CNB) versus mammograph-guided biopsy for suspicious microcalcifications. without definite breast mass

MEDICAL IMAGING AND BREAST DISEASE HOW CAN WE HELP YOU?

Using lesion washout volume fraction as a biomarker to improve suspicious breast lesion characterization

Spectrum of findings of sclerosing adenosis at breast MRI.

Diseases of the breast (1 of 2)

Triple Negative Breast Cancer: Clinical Presentation and Multimodality Imaging Characteristics

ORIGINAL ARTICLE EVALUATION OF BREAST LESIONS USING X-RAY MAMMOGRAM WITH HISTOPATHOLOGICAL CORRELATION

National Diagnostic Imaging Symposium 2013 SAM - Breast MRI 1

Evaluation of thyroid nodules: prediction and selection of malignant nodules for FNA (cytology)

Transcription:

A-056 NEW SUBTRACTION ALGORITHMS FOR EVALUATION OF BREAST LESIONS ON DYNAMIC CONTRAST ENHANCED MR MAMMOGRAPHY So Hee Cho, M.D., Byung Gil Choi, M.D., Hak Hee Kim, M.D., Euy Neyng Kim, M.D., Bum-soo Kim, M.D., Kyu Ho Choi, M.D., Ji Youn Han, M.D. 1, Sang Seol Chung, M.D. 2, Tae Kim 3, Kyung Sub Shinn, M.D. Department of Radiology, College of Medicine, The Catholic University of Korea 1 Department of Internal Medicine, College of Medicine, The Catholic University of Korea 2 Department of General Surgery, College of Medicine, The Catholic University of Korea 3 Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea Purpose: To evaluate new subtraction algorithms for detection of enhancing lesion on dynamic contrast-enhanced MR mammography (CE-MRM). Materials and Methods: This prospective study included 25 patients with suspicion of breast disease. All patients underwent CE-MRM using fast low-angle shot three dimension sequence including whole breasts. The scout images were obtained and then repeated six times after bolus injection of contrast medium (3mm-slice thickness, no gap, 34-48 slices, every 60-90 seconds). Modified serial subtraction (CE image minus scout image), step-by-step subtraction (CE image minus just previous image), and reverse subtraction (CE image minus the last CE image) were obtained. Two radiologists analyzed subtraction images by agreement on the differentiation of benign from malignant lesions. The diagnostic criteria were dynamic and morphologic pattern. Results: All cases underwent new subtraction algorithms. Mean post-processing time was 9 minutes. Subtraction images of all cases permitted better visualization of contrast enhancement and enhancing pattern. Eleven of all cases histopathologically confirmed as 7 malignant and 4 benign lesions. The sensitivity, specificity, and accuracy on confirmed cases were 85.7 %, 100 %, and 90.9 %. Conclusion: For the evaluation of malignant lesion, new subtraction algorithms can be a valuable adjunct to the standard sequences and as a practical alternative to dynamic study with contrast medium.

A-060 MRI OF BREAST IMPLANT-RELATED COMPLICATIONS Seung-Hae Chung, M.D., Shin-Ho Kook, M.D., Young-Uk Lee, M.D., Hae-Won Park M.D. Deptment of Radiology, Kangbuk SamSung Hospital, School of Medicine, SungKyun Kwan University, Seoul, Korea Purpose: To assess the usefulness of MRI in the preoperative diagnosis of breast implantrelated complications. Materials and Methods: Thirty-four breast implants in 17 patients were examined. Eight breasts had a history of repeated surgery due to rupture and in eight others, simultaneous interstitial silicone injection had been performed. MR images of the 34 implants were prospectively analyzed for implant-related complications, without prior clinical information, and the findings were compared with the results of surgery. ResuIts: The implant-related complications seen on MRI were infections in three cases, seromas in two, and implant malposition in two. The linguine sign was seen in eight cases and intraparenchymal silicone in 17. Among the 32 removed implants, rupture was genuine in ten cases (nine, extracapsular: one, intracapsular). In evaluating the MR findings of implant rupture, the linguine sign showed 80% sensitivity, 100 % specificity and 93.8 % accuracy. Intraparenchymal silicon also, evealed high sensitivity (90 %), but relatively low specificity and accuracy (63.7 % and 71.9%, respectively): this was due to the difficulty in differentiating granulomas after a previous rupture from injected silicone material. MRI was useful for visualization of implant migration, the direct relationship of extended or extruded silicone in extracapsular rupture and the localization of silicone granulomas, as seen on multiplanar images. The extent of infection was clearly demonstrated on contrast-enhanced scan. There was relatively good correlation between the degree of contracture seen on physical examination and that seen on MRI. Conclusion: MRI was an effective and useful method for the preoperative evaluation of implant-related complications: degree of contracture was successfully predicted.

A-059 MR GALACTOGRAPHY USING THREE-DIMENSIONAL FAT-SUPPRESSED T2-WEIGHTED SINGLE SHOT FAST SPIN ECHO TECHNIQUE: COMPARISON WITH CONVENTIONAL GALACTOGRAPHY AND SONOGRAPHY Yeon Hyeon Choe, M.D., Boo-Kyung Han, M.D. Department of Radiology, Samsung Medical Center, Sunkyunkwan University School of Medicine, Seoul, Korea Purpose: To evaluate the ability of MR galactography in comparison with conventional galactography and sonography. Materials and Methods: In 28 patients with nipple discharge, 3-dimensional fat-suppressed T2- weighted imaging using single shot fast spin echo technique was prospectively performed (axial and sagittal scans, TR/TE = 61891/190, 256X192 matrix, 2 mm thickness, 14 cm FOV) without intraductal injection of MR contrast medium. All patients subsequently underwent conventional X-ray galactography (two views) after intraductal injection of 0.5-1.5 ml iodinated contrast medium and sonography. Findings of MR galactography, conventional galactography, and sonography were compared by two radiologists. Pathological confirmation was made in 13 patients. Results: MR galactography depicted intraductal lesions in 5 patients. Pathologic findings revealed intraductal papilloma in 8 patients, ductal dilatation and fibrocystic change in 4, intraducal carcinoma in 1. Sensitivity, specificity, and diagnostic accuracy of MR galactography based on findings of conventional galactography and sonography were 27.8%, 100%, and 53.6% respectively. Sensitivity, specificity, and diagnostic accuracy of MR galactography based on pathologic findings were 33.7%, 75%, and 46.2% respectively in 13 patients, while sensitivity, specificity, and diagnostic accuracy of conventional galactography and sonography based on pathologic findings were 77.8%, 25%, 61.5% for conventional galactography and 33.3%, 0%, 63.6% for sonography respectively. Conclusion: Three-dimensional MR galactography using single shot fast spin echo technique is not sensitive, but more specific in detection of intraductal abnormalities compared with conventional galactography and sonography.

A-054 MRI OF MULTIPLE FIBROADENOMA IN BREASTS: COMPARISION WITH COLOR DOPPLER IMAGES AND HISTOLOGIC FINDINGS Kyung Won Lee M.D., Soo Young Chung M.D., Ik Yang M.D., Hong Dae Kim M.D., Bong Wha Chung M.D. 1 Department of Radiology, 1 Surgery, Hallym University, College of Medicine, Seoul, Korea Purpose: To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenomas of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. Materials and Methods: MRI (1.0 Tesla, T1WI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenomas in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow was compared. Results: The observed degree of signal intensity was classified into three groups, as follows : negative, 8.3%, mild to moderate, 54.2% ; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Conclusion: Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

A-055 DIAGNOSTIC VALUE OF 3D-GRADIENT ECHO DYNAMIC CONTRAST ENHANCED MRI IN BREAST CANCER Ik Yang M.D., Soo Young Chung M.D., Kyung Won Lee M.D., Hong Dae Kim M.D., Bong Wha Chung M.D. 1 Department of Radiology, 1 Surgery, Hallym University, College of Medicine, Seoul, Korea Purpose: To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D- DMRI) in diagnosis (Dx) of breast cancer. Materials and Methods: 3D-DMRI with Gd-DTPA were obtained in 38 breast cancers, 22 fibroadenomas and three normal volunteers on a 1.0T MR unit. We retrospectively evaluated DMRI findings according to the speed, contrast enhancement (CE) on delayed phase, and compared the diagnostic accuracy. Results: There was no significant difference of signal intensity between fibroadenoma (FA) and carcinoma on conventional MRI. Rapid CE (within one minute) was noted in 35 lesions (92.1%) of cancer, but relatively low and slow CE (after five minutes) was noted in three lesions (7.9%) of cancer. Gradual CE was noted in 21 lesions (95.5%) of FA, but moderate degree of rapid CE was noted in one case (7.9%) of FA. The maximal amount of CE showed no significant difference between FA and cancer on delayed enhanced phase of 3D-DMRI. On 3D-DMRI, irregular, spiculated border with high CE was noted in all cases of cancer. Especially, irregular thick peripheral CE with central necrosis is noted 11 cases (28.9%) of cancer. Conclusion: 3D-DMRI is a useful technique in diagnosis of breast cancer. On DMRI, morphologic change after CE was the most useful parameter for diagnosis of breast cancer.