HiFFUT A New Class of Transducer

Similar documents
Available online at ScienceDirect. Physics Procedia 87 (2016 ) 35 41

HiFFUT A New Class of Transducer

warwick.ac.uk/lib-publications

Evaluation of heavy wire bond tools with ceramic tip technology

A micro ultrasonic motor using a micro-machined cylindrical bulk PZT transducer

New ultrasonic technologies for food dehydration process intensification

MATCHING LAYER DESIGN OF AN ULTRASONIC TRANS- DUCER FOR WIRELESS POWER TRANSFER SYSTEM

The Do s and Don ts of Pressure Transducers

Descriptions of NDT Projects Fall 2004 October 31, 2004

Modelling and Fabrication of High Frequency Ultrasound Transducer Arrays for Medical Applications

Technical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives

High-frequency Doppler Ultrasound Transducer for the Peripheral Circulatory System

Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator

Exploring Cavitating Phenomenon With and Without Ultrasonic Transducer

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

771. Ultrasonic systems for liquid pulverizer

Li, Li (2017) A surgical bone biopsy needle using ultrasonic-sonic frequency vibration. PhD thesis.

MODELING USING THE FINITE ELEMENT METHOD OF AN ULTRASONIC STACK USED FOR ULTRASONIC WELDING STAKING PROCESS

Ultrasonic Transducer. Piezoelectric ceramics / Piezoelectric polymer film / Piezoelectric thin film

Figure 1 The Human Heart

Fundamentals of Pressure Transducers

Tru-Fit 10k Fittings

RLS /M MX SERIES

RLS /M MX SERIES

Dynamic Hollow Cylinder System Proposal

CORESTA RECOMMENDED METHOD N 22

Ultrasonic Transducer for the Hydrothermal Method

Development of novel ultrasonic transducers for microelectronics packaging

Liquid ring vacuum pumps single-stage

Development of innovative transducer designs for NDT applications: From 1-3 piezocomposite definition to 2D array probe manufacture

STUDY ON STRUCTURE OF PZT PILES BASED TRANSDUCER FOR HARVESTING ENERGY FROM ASPHALT PAVEMENT

Test Setup to Measure Gains of the Angra Photomultipliers Using the Single Photoelectron Technique

A Study of Applications of Medical Piezoelectrical Ultrasonic Transducer Materials and the Transducers

Invasive Measurement of Blood Pressure

Can you believe that the ultrasonic waves are used for cleaning purpose???

Ultrasonically-assisted Hydrothermal Method for Ferroelectric Material Synthesis

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

ROTARY UNION 9000 SERIES GENERAL PURPOSE MODELS ADDED MODELS ADDED. Operating Parameters FEATURES & BENEFITS MEDIA PRESSURE* TEMPERATURE* SPEED*

Test Procedure for Piezoelectric Accelerometer Ice Thickness Measurement

PZT/ZnO EXPERIMENT MODELLING

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories

(12) United States Patent (10) Patent No.: US 6,691,578 B1

AN EXPERIMENTAL STUDY ON TRANSDUCER FOR THE DDS TECHNOLOGY DEMONSTRATOR ANDRZEJ ELMINOWICZ, WALDEMAR LIS*, WŁADYSŁAW MĘCIŃSKI

DESIGN AND MODELING OF THE POWER ULTRASONIC TRANSDUCERS

(all beam angles defined as, -3dB or half power inclusive)

BGS MODEL HP-165M FLUID END PARTS LIST

AK FIXATOR SYSTEM AK1

DC Unbalance Tolerance Testing in PSE s

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Quick Sealing with a Twist to Connect Actuation Method

Effects of Magnetic field on Voltage response of PMT

P SERIES. 250 psi NFPA Pneumatic Cylinder TECHNICAL BROCHURE. Bore Sizes from 11/2 to 14

w. D. Jolly, F. A. Bruton, and C. Fedor

Custom-Made Products / Scientific Research Instruments

Detection. at first sight. One of the newest trends

Multielement ultrasonic probes for projection imaging of biological media

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

RLS /E-EV MX SERIES

Oil Transmission Pipelines Condition Monitoring Using Wavelet Analysis and Ultrasonic Techniques

FasMate Quick Connectors Industry Applications:

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL

Characteristics of Liquids Atomization Using Surface Acoustic Wave

Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

COST, PROCESS & QUALITY IMPROVEMENT

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

Wire bonding is a widely used method of chip interconnection

RiGO801 Laboratory Requirements

Ultrasonic Instruments for Non-Destructive Testing

Two Modified IEC Ear Simulators for Extended Dynamic Range

Texas A&M University Electrical Engineering Department. ELEN 665 RF Communication Circuits Laboratory Fall 2010

Feng Xiujuan National Institute of Metrology (NIM),China

This is the accepted version. Published version available: /TUFFC

A STUDY ON HIGH FREQUENCY VIBRATION FOR TOOTH EXTRACTION

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Environmental Submersible Pumps

RUBBER WATERBLAST HOSES

Intra-Arterial Blood Pressure Monitoring

DURASEAL. High Integrity, Double Block and Bleed Plug Valve.

This is the author s final accepted version.

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Development of Ultrasonic Sensor for Visualisation under Heavy Liquid Metal

API. Generic Procedure. for the. Ultrasonic Examination. Ferritic Welds

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

DEVELOPMENT OF ULTRASONIC METHOD OF RADIAL CLEARANCE ASSESSMENT FOR BOLTED JOINTS AT RESTRICTED ACCESS

ULTRASONIC TRANSDUCERS FOR SODIUM COOLED REACTORS..F.Saillant, O.Martin, S.Charrier, J.Sibilo, AREVA, France F.Baqué, CEA - DEN, France

J350, J360 and J370 PLUMBING PARTS CATALOG

Nondestructive Testing Procedure: Liquid Penetrant Testing

Operator s Manual Development of a Pulsatile Left Heart Simulator

ULTRASONIC DETECTION OF SIMULATED CORROSION IN 1 INCH DIAMETER STEEL TIEBACK RODS

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

Active Thermography NDT Method for Structural Adhesive and Mechanical Joints

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

SIMULATOR FOR TESTING THE FRICTION TORQUE OF THE FEMORAL HEAD OF A HIP PROSTHESIS

External Skeletal Fixation (ESF)

NETAFIM FLEXIBLE PIPES FLATNET

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

IEC 87: Ultrasonics Overview update July 2002

Transcription:

HiFFUT A New Class of Transducer Project Meeting April 2017 Dr Andrew Feeney

Study of the electro-mechanical behaviour of flexural ultrasonic transducers This work will help us to design HiFFUTs for particular applications, and be able to control the response during operation by expediently tuning to the resonance frequency of the transducer. Research conducted with MPhys candidates Michael Ginestier and Chris Wells. Commercial transducer used for the research, the schematic for which is shown. Research submitted to Applied Physics Letters Expanded version being produced for Ultrasonics Commercial transducer schematic (not to scale) 2 Analysis of electro-mechanical transducer behaviour

Experimental setup shown opposite, consisting of a function generator and oscilloscope. The function generator is used to drive the transducer, and the oscilloscope is used to measure the voltage across the electrical contacts of the flexural transducer. The mechanical vibrations are recorded by the laser Doppler vibrometer. The response of the transducer can therefore be monitored for different input signal frequencies, amplitudes, and number of cycles. Experimental setup 3 Analysis of electro-mechanical transducer behaviour

Once the driving voltage is terminated, the flexural transducer response decays to zero, which is a ringdown at resonance. The measurements demonstrate that the transducer vibrates at its resonance frequency almost instantly after the driving excitation signal is switched off, giving a useful and fast indicator of transducer resonance frequency, just with an oscilloscope and function generator. When the drive signal is switched off, a discontinuity in the measured voltage signal occurs due to a phase difference between the driving signal and the vibration displacement of the membrane However, this is only true for driving frequencies close to resonance, with a deviation of a few percent. For driving frequencies further from resonance, the effective vibration frequency oscillates before converging on the resonance frequency of the transducer. Transducer response for a 45kHz drive excitation, with (inset) the resonant ring-down response 4 Analysis of electro-mechanical transducer behaviour

Amplitude-frequency response of the FUT 5 Analysis of electro-mechanical transducer behaviour

Effective frequency as a function of time for a range of drive frequencies around resonance 6 Analysis of electro-mechanical transducer behaviour

A mechanical analogue has been developed for the analysis of transducer response. This analogue, whilst not providing physical understanding, can be used, for example, to fit with experimental data to assess the quality of a flexural transducer. The flexural transducer is modelled on a simple spring-dashpot configuration. Three response regions have been assumed. The first is the build-up to steady-state, where the drive signal is applied to the transducer at rest. The transducer takes time to reach steady-state, which is the second region. The third region appears after the cessation of the drive frequency, and characterised by exponential decay, or ring-down at resonance. Region 1 Mx ሷ + Cx ሶ + Kx = Fsinωt. H(t 0 t) Region 2 Mx ሷ + Cx ሶ + Kx = Fsinωt Region 3 X(t) = Fe ζω nt cos(ω d t + θ) Analogue schematic of the transducer 7 Analysis of electro-mechanical transducer behaviour

Experimental versus analogue results for a 40kHz drive signal Experimental versus analogue in Stage 1 8 Analysis of electro-mechanical transducer behaviour

Laser welding chosen as a new approach to the fabrication of flexural transducers, and hence HiFFUTs. Efficiency, repeatability and precision of transducer manufacture. Titanium (Grade 2 ASTM) chosen as the base material, to produce a cap of 13.70mm total diameter, side-wall support length of 4.00mm with wallthickness of 2.24mm, and membrane thickness of 1.00mm. Bismuth titanate (BiT) ceramic, 0.89mm thick, 6.35mm in diameter. Bolts which can accommodate a torque wrench Plates to hold ceramic and cap membrane in place Disc, cut from Ti sheet, with BiT ceramic bonded on top, forming the membrane Weld zones, in notches cut into tubing Ti tubing to act as transducer side-wall Supports to fix bolts in place Curing rig designed for the controlled bonding of piezoelectric ceramic discs to transducer cap membranes 9 Laser Welding for HiFFUT Fabrication

Transducer designed to operate in the (0,0) mode at high frequency, calculated to be 78887Hz. Bismuth titanate has a Curie temperature of 650 C (Ferroperm), thereby permitting high-temperature operation. High-temperature epoxy resin used as the bonding agent (Epo-Tek 353ND). This agent can be used at 250 C (continuous) or 350 C (intermittent). From Physik Instrumente (PI) GmbH & Co. guidelines, a bonding pressure of 5-7bar should be applied. Simulated resonance frequency spectrum for the laser-welded flexural transducer, from PZFlex finite element analysis Laser Welding for HiFFUT Fabrication 10

More detailed understanding is required of the influence of applied bonding pressure in the fabrication of flexural transducers. The curing rig shown on the right can be used, designed for the laser-welded flexural transducer, with a cylindrical insert to apply pressure to the ceramic surface only. Different pre-load pressures can be studied, and the transducers then characterised using an impedance gain/phase analyser (Agilent 4294A), for example to determine electromechanical coupling performance. Further analysis using laser Doppler vibrometry and radiation pattern measurement will also be important. Acquired piezoelectric ceramics (PMN-PT(30%)), with thickness of 2.00mm, diameter of 9.97mm. Titanium cap designed for a (0,0) mode at 25948Hz, with total diameter of 17.80mm, side-wall length of 6.00mm, side-wall thickness of 0.90mm, and a membrane thickness of 1.00mm. Bolts which can accommodate a torque wrench Plates to hold ceramic and cap membrane in place Supports to fix bolts in place Curing rig designed for the controlled bonding of piezoelectric ceramic discs to transducer cap membranes 11 Influence of bonding pressure

Simulated resonance frequency spectrum for the flexural transducer for bonding pressure analysis, from PZFlex finite element analysis 12 Influence of bonding pressure

Correspondence with Gilwood (Fabricators) Company Ltd. And FlexEJ Limited for manufacture. The main vessel will be manufactured to 4 Sch120 pipe, where the general dimensions are shown in the table. The vessel is designed in accordance with ASME VIII Div.1 (NCMS) and certified to the PED 2014/68/EU. Membrane temperature limit: 140 C, vessel temperature limit: 300 C. Gland specification: Seals multiple wires, supplied by Thermal Detection Limited. High Pressure Insulated Wire Sealing Gland (HPPL) Seals up to 2070bar (at 20 C) Grade 316L stainless steel MK4 Hill Air Pump 1/8 BSP Connection Rated up to 4000psi (276bar) Removable panels for positioning transducers Nominal size [inches] Flange securing rubber membrane for pressurisation of fluid Outside diameter [inches] Pressure gland ports for throughcabling Panel with bleed-valve, pressurisation port for connection to the pump system, and pressure-release valve Outside diameter [mm] Wall thickness [inches] Wall thickness [mm] Supports Weight [lb/ft] Weight [kg/m] 4 4.500 114.3 0.438 11.13 19.00 28.32 Pressure vessel body 13 Progress in Pressurisation System Design

Carbolite Gero Compact Horizontal Split Tube Furnace - EST / EZS Maximum operating temperature of 1200 C Fully-integrated temperature controller Customisation options available, including for overtemperature protection Can operate for a range of modified atmospheres including vacuum and gas It is proposed that a separate cylinder is fabricated for testing HiFFUTs in liquid, similar to the vessel for the pressure testing This cylinder will incorporate measurement cabling access, and correspondence with Carbolite Gero on this will be essential for safety assessment The volume of liquid tested at particular temperatures will need to be closely monitored due to pressure increases Chamber accommodates a range of sample lengths and diameters Temperature controller Furnace vessel 14 Progress in Temperature Vessel Design

Next Steps Conduct laser welding to fabricate the Titanium caps. Fabrication of a laser-welded flexural transducer with BiT piezoceramic driver, followed by a characterisation process comprising: Measurement of electrical properties of the transducer, including admittance loops to quantify the quality and coupling in the device. This method can be used to monitor transducer impedance, phase and resonance frequency as a function of temperature, to determine performance at high-temperature levels. Laser Doppler vibrometry to verify the mode shapes of the transducer. Radiation pattern measurement to quantify the output of the transducer. Report on the influence of bonding pressure level on the performance of flexural transducers. Finalise acquisition of the pressure vessel. Design of candidate transducers for testing in a pressurised environment, around 200bar. Agree on the date of the next meeting. 15

Project Gantt Chart 16