Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography

Similar documents
Comparative Sensitivity Assessment of Cone Beam Computed Tomography and Digital Radiography for detecting Foreign Bodies

Reza Javadrashid 1, Farzaneh Kaviany 2, Zahra Shahmorady 3, Mahdi Niknamy 2, Masoud Golamian 4, Shohreh Sadrarhami 4, Mohammad Taghi Niknejad 4

I. Introduction ORIGINAL ARTICLE. Mehrdad Abdinian 1,2, Maedeh Aminian 2, Samad Seyyedkhamesi 3

International Journal of Research in Health Sciences ISSN: Available online at: Case Study

Is Bedside Ultrasound a Reliable Method for Detecting Soft Tissue Foreign Bodies in Upper Extremity Penetrating Trauma Patients?

Retained Metallic Foreign body- A Diagnostic and Surgical Challenge

International Journal of Case Reports in Medicine

Conventional radiograph verses CT for evaluation of sagittal fracture of mandibular condyle

Computed tomography. Department of Radiology, University Medical School, Szeged

Current status of diagnostic imaging in dental university hospitals in Japan

Managing Cone Beam CT Dose in Paediatric Dental Imaging

COMPUTED TOMOGRAPHY COURSE

The diagnostic value of Computed Tomography in evaluation of maxillofacial Trauma

Ethan M. Braunstein, M.D. 1, Steven A. Goldstein, Ph.D. 2, Janet Ku, M.S. 2, Patrick Smith, M.D. 2, and Larry S. Matthews, M.D. 2

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

Practical CT and MRI Anthony J. Fischetti, DVM, MS, DACVR Department Head of Diagnostic Imaging The Animal Medical Center, New York OBJECTIVE:

2

Role of High Frequency Ultrasonography for Detection of Radiolucent Foreign Bodies and Their Surgical Management

CT Imaging at the Point-of-Care

B. CT protocols for the spine

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

Advances in Emergency Imaging

Extraoral Radiology October 10th, 2008

Different Radiological Findings in Turkish Edentulous Patients

CT Scanning Protocol For V2R Guided Surgery Solutions

BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM

Radiographic Evaluation of Bone Formation and Density Changes after Mandibular Third Molar Extraction: A 6 Month Follow up

X-ray (Radiography) - Bone

The frequency and characteristics of idiopathic osteosclerosis and condensing osteitis lesions in a Turkish patient population

Clinical Applications

Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy.

Two- and Three-dimensional Orthodontic Imaging Using Limited Cone Beam Computed Tomography

Original Research THE USE OF REFORMATTED CONE BEAM CT IMAGES IN ASSESSING MID-FACE TRAUMA, WITH A FOCUS ON THE ORBITAL FLOOR FRACTURES

Head to new heights with your imaging SCANORA 3D

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

Keywords: Mandible, Maxilla, Teeth, Cone Beam CT, Implants, Tumor and tumor-like conditions

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Basic Abdominal and Pelvic Imaging Concepts. David L. Smith, MD Assistant Professor of Radiology

ORIGINAL PAPERS. Revista Română de Anatomie funcţională şi clinică, macro- şi microscopică şi de Antropologie. Vol. XV Nr

Clinical details: Details of scan: CONE BEAM CT REPORT: Name: H. B. Gender: Reason for referral: Referred by:

Introduction to Radiology

Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography

UNIVERSITY OF MEDICINE AND PHARMACY GR. T. POPA - IASI FACULTY OF DENTAL MEDICINE

Management of Penetrating Wrist Injuries in the Emergency Department

AUA Guidelines for Imaging Known or Suspected Ureteral Calculi. Michael Ferrandino, MD Assoc Professor of Urology Duke University Medical Center

Computed Tomography (CT) - Sinuses

Radiology. General radiology department. X-ray

Normal Radiographic Anatomy Maxillary Central Area

Message of the Month for GPs June 2013

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

The Use of Ultrasound as an Adjunct to X-Ray For the Localization and Removal of Soft Tissue Foreign Bodies in an Urgent Care Setting

Scientific Affairs. Scientific Affairs

Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature:

Optimization of Radiological Diagnostics of Developmental Dysplasia of Hip (DDH)

Role of the Radiologist

Cone Beam 3D Imaging

Mædica - a Journal of Clinical Medicine. Interobserver variability of the diagnosis of apical periodontitis on panoramic radiography assessment

Digital tomosynthesis (DT) has been well described as a

Diagnostic Tools: Equine Dentistry. Dr. Chris Blevins Equine Field Service Clinician

Australian and New Zealand College of Veterinary Scientists. Fellowship Examination. Veterinary Radiology Paper 1

Test Bank CHAPTER 1. Multiple Choice. 1. Who was awarded the first Nobel Prize for physics in 1901, for his experimental work with. radiation?

RADIOLOGY (MEDICAL IMAGING)

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet

Medical Diagnostic Imaging

PERSPECTIVES OF THE TOOTH RESTORATION TECHNOLOGY BASED ON THE COMPUTED TOMOGRAPHY DATA

Dental Cone Beam CT. What is Dental Cone Beam CT?

The Quality Leader in 3D Cone Beam CT

EVALUATION OF MODIFIED EXTRAORAL TECHNIQUE IN ZYGOMATIC ARCH EXAMINATION

X-Ray & CT Physics / Clinical CT

Digital Imaging from a new perspective

Sang-Sun Han, 1 Kwang-Min Lee, 2 and Kee-Deog Kim Introduction

Computed Tomography (CT) - Abdomen and Pelvis

Normal Radiographic Anatomy Maxillary Lateral Area. Carmen Elena Georgescu1, Gabriela Tãnase 2, Augustin Mihai 3. Objectives.

Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan

Imaging Choices in Occult Hip Fracture

Acute renal colic Radiological investigation in patients with renal colic

Postmortem Computed Tomography Finding of Lungs in Sudden Infant Death.

The treatment protocol for replacing

IONISING RADIATION REGULATIONS 99

Implant Imaging JCD /jp-journals REVIEW ARTICLE ABSTRACT

For true visualisation

Inter-Observer and Intra-Observer Variability In the Assessment of The Paranasal Sinuses Radiographs

Effect of Spatial Position in the Field of View on Dimensional Changes in Cone Beam Computed Tomography

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

Pediatric Imaging Spine MRI and Spine CT Test Request Tip Sheet

Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study

E.A.O. Guidelines for the use of Diagnostic Imaging in Implant Dentistry

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Ultrasound assessment of T1 Squamous Cell Carcinomas of the Tongue.

RADIOLOGIC TECHNOLOGY (526)

Texas A&M College of Dentistry Oral and Maxillofacial Radiology

Diagnostic Tools: Equine Dentistry. Dr. Chris Blevins Equine Field Service Clinician

Death due to Hypothermia: Postmortem Forensic Computed Tomography.

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

Low-dose CT Lung Cancer Screening Guidelines for Pulmonary Nodules Management Version 2

Interpretation Basics of Cone Beam Computed Tomography COPYRIGHTED MATERIAL

Transcription:

(2010) 39, 72 78 2010 The British Institute of Radiology http://dmfr.birjournals.org RESEARCH Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography MH Aras 1, O Miloglu*,2, C Barutcugil 3, M Kantarci 4, E Ozcan 5 and A Harorli 2 1 Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gaziantep University, Gaziantep, Turkey; 2 Department of Oral Diagnosis and Radiology, Faculty of Dentistry, Ataturk University, Erzurum, Turkey; 3 Department of Conservative Dentistry, Faculty of Dentistry, Ataturk University, Erzurum, Turkey; 4 Department of Radiology, Faculty of Medicine, Ataturk University, Erzurum, Turkey; 5 Department of Endodontics, Faculty of Dentistry, Ataturk University, Erzurum, Turkey Objective: The purpose of this study was to compare the sensitivity for detecting foreign bodies among conventional plain radiography, CT and ultrasonography in in vitro models. Methods: Seven different materials were selected as foreign bodies with dimensions of approximately 16160.1 cm. These materials were metal, glass, wood, stone, acrylic, graphite and Bakelite. These foreign bodies were placed into a sheep s head between the corpus mandible and muscle, in the tongue and in the maxillary sinus. Conventional plain radiography, CT and ultrasonography imaging methods were compared to investigate their sensitivity for detecting these foreign bodies. Results: Metal, glass and stone can be detected with all the visualization techniques used in the study in all of the zones. In contrast to this, foreign bodies with low radiopacity, which could be detected in air with CT, became less visible or almost invisible in muscle tissue and between bone and muscle tissue. The performance of ultrasonography for visualizing foreign bodies with low radiopacity is relatively better than CT. Conclusions: Ultrasonography detects and localizes superficial foreign bodies with low radiopacity in the tissues of the body more effectively than CT and conventional plain radiography. However, CT is a more effective technique for visualization of foreign bodies in air than ultrasound and conventional plain radiography. (2010) 39, 72 78. doi: 10.1259/dmfr/68589458 Keywords: computerized tomography; foreign body; plain radiography; ultrasonography Introduction are any objects originating outside the body. They frequently occur due to various accidental injuries such as traffic accidents, explosions or bursts, and gunshot injuries in the maxillofacial region. Depending on the type of trauma, the composition and location of the foreign bodies can vary considerably. 1 Infection, inflammation and pain are potential complications after impact of foreign bodies. Superficial foreign bodies are usually easy to remove if seen. However, penetrating foreign bodies are more difficult to remove. It is necessary to determine whether the foreign body is *Correspondence to: Dr Ozkan Miloglu, Department of Oral Diagnosis and Radiology, Faculty of Dentistry, Ataturk University, Erzurum, 25240, Turkey; E-mail: omiloglu@hotmail.com Received 9 December 2008; revised 30 January 2009; accepted 5 April 2009 near a vital structure or not. The most common retained objects are wood splinters, glass fragments and metallic objects. 2 Localizing and retrieving foreign bodies can be complicated. Conventional plain radiographs, CT, ultrasonography and MRI can be used to identify foreign bodies. 2 The purpose of this study is to investigate the sensitivity of conventional plain radiography, CT and ultrasonography for detecting foreign bodies in in vitro models. Materials and methods Seven different materials were prepared as foreign bodies with dimensions of about 16160.1 cm for this

MH Aras et al 73 Table 1 Radiopacity of the investigated foreign bodies and their surroundings HU Metal 3863 15363 Glass 540 1740 Wood 50 80 Stone 2200 2900 Acrylic 80 130 Graphite 750 1036 Bakelite 85 170 Bone 80 110 Muscle 55 65 Air 21024 in vitro study. The most frequently retained foreign body materials were selected as metal (made up of iron), glass, wood, stone, acrylic, graphite and Bakelite. As a benchmark for the substances radiopacity, the foreign bodies were scanned using a spiral CT scanner. Radiopacities of substances and surrounding areas were measured in HU (Table 1). Specimen (sheep s head): Only one specimen (sheep s head) was used in this study. The applications on the specimen were done 1 day after death. All of the images were taken in the same day. on bone surface: were placed between the corpus mandible and muscle in a sheep s head. With a scalpel, a slot was prepared in the muscle and the foreign body was placed vertically onto the bone s surface. in muscular tissue: were placed into the sheep s tongue. With a scalpel, a tunnelling gap was prepared in the tongue and the foreign body was placed horizontally in the middle of the sheep s tongue. in air: were placed into the maxillary sinus of the sheep s head. With a sharp osteotome, a triangular window was opened in the crestal ridge of the maxilla and the foreign body was placed directly into the sinus. The window was closed before imaging. Imaging Three different imaging methods were compared to investigate their sensitivity for detecting foreign bodies in the in vitro models. Conventional plain radiography: Conventional plain film imaging was performed using the lateral cephalometric mode of a Planmeca Proline CC 2002 (Helsinki, Finland). Lateral cephalometric radiography has been used for monitoring unknown objects. An apparatus was used to position the specimen with the mid-sagittal plane vertical and Frankfurt plane horizontal. Exposure settings were 65 kvp, 2 ma and 0.8 s. CT: Multidetector spiral CT was performed with a 16 detector-row CT scanner (Aquillon; Toshiba Medical Systems, Tokyo, Japan). Scans were obtained by using a collimation of 1 mm, 16 rows, with a helical pitch of 3, a gantry rotation speed of 0.75 s per round, voltage of 120 kv and current of 300 ma. To ensure standardization in all imaging techniques, the sheep s head was fixed during scanning and was not moved while changing foreign bodies. Ultrasonography Ultrasound scanning was performed using an ultrasound system (Toshiba Aplio SSA-770A, 7.5 MHz linear probe for visualizing superficial tissues; Toshiba, Tokyo, Japan). The ultrasound probe was placed to obtain images of the dorsal aspect of the tongue. Scanning parameters were obtained by one of the authors, a radiology specialist with 10 years experience (MK), at Ataturk University, Faculty of Medicine and Department of Radiology, on a real-time basis. Analysis The imaging methods were investigated to assess each foreign body s visibility on a four-point scale with the anchors no image (0) and excellent image (4+) (Table 2). The images were independently assessed by six different observers, three of whom were qualified to PhD level (one maxillofacial surgeon and two radiologists) and three research assistants (one studying oral diagnosis and radiology, one studying endodontics and one studying conservative dentistry). The observers were aware of the existence of the foreign bodies; however, they were not aware of the composition of the foreign bodies. The average of the results was recorded after the observations. Results Conventional lateral plain radiography Table 3 summarises the visibility of the foreign bodies in conventional plain radiographs. The conventional plain radiography images showed no artefacts. Metal, Table 2 Basic criteria used for image interpretation Grade Assessment Definition ++++ Excellent image Excellent resolution of details and excellent visibility, good demarcation from surrounding +++ Good image Good resolution of details, demarcation from surrounding, clear visibility ++ Fair image Insufficient resolution of details, insufficient visibility, insufficient demarcation + Bad image Details not resolved, bad demarcation from surrounding, bad visibility 0 No image Invisible

74 MH Aras et al Table 3 Image quality of foreign bodies in various regions observed via conventional plain radiography Conventional plain on bone in muscle in air Metal ++++ +++ +++ Glass ++ ++ ++ Wood 0 0 0 Stone +++ ++ +++ Acrylic 0 0 0 Graphite 0 ++ 0 Bakelite 0 0 0 glass and stone foreign bodies were clearly detected between bone and muscle, whereas wood, acrylic, graphite and Bakelite were not detected at all. Metal, glass, stone and graphite foreign bodies were clearly detected in the muscle, whereas wood, acrylic and Bakelite were not detected at all. Metal, glass and stone foreign bodies were clearly detected in the maxillary sinus, whereas wood, acrylic, graphite and Bakelite were not detected at all (Figures 1a, 2a and 3a). CT Table 4 summarises the visibility of the foreign bodies in the CT images. The image of the metallic foreign a b c Figure 1 of foreign body on bone. (a) Conventional plain radiography. (b) CT. (c) Ultrasonography. 1, dry wood; 2, stone; 3, acrylic; 4, Bakelite

MH Aras et al 75 a b c Figure 2 of foreign body in muscle. (a) Conventional plain radiography. (b) CT. (c) Ultrasonography. 1, glass; 2, dry wood; 3, acrylic; 4, graphite body showed artefacts during imaging with CT; however, these artefacts did not cause localization errors. Metal, glass, stone and graphite foreign bodies were clearly detected between bone and muscle, whereas acrylic and Bakelite were not demonstrated Table 4 Image quality of foreign bodies in various regions observed via CT CT on bone in muscle in air Metal ++++ ++++ ++++ Glass +++ ++++ ++++ Wood 0 + ++ Stone ++++ ++++ ++++ Acrylic + ++ ++ Graphite +++ ++++ ++++ Bakelite ++ ++ ++++ clearly. Moreover, wood could not be seen at all. Metal, glass, stone and graphite foreign bodies were clearly detected in the muscle, whereas wood, acrylic and Table 5 Image quality of foreign bodies in various regions observed via ultrasonography Ultrasonography on bone in muscle in air* Metal +++ ++++ 0 Glass +++ ++++ 0 Wood ++ +++ 0 Stone +++ +++ 0 Acrylic ++ + 0 Graphite +++ +++ 0 Bakelite + +++ 0 *It is not possible to evaluate the foreign bodies visibility in the air with ultrasonography.

76 MH Aras et al a b c Figure 3 of foreign body in air. (a) Conventional plain radiography. (b) CT. (c) Ultrasonography. 1, metal; 2, dry wood; 3, graphite; 4, Bakelite. Note that it is not possible to evaluate the foreign bodies visibility in air with ultrasonography. For this reason, only one figure was submitted to represent all bodies. Bakelite were demonstrated with difficulty. All foreign bodies placed into the sinus were detected clearly with CT (Figures 1b, 2b and 3b). Ultrasonography Table 5 summarises the visibility of the foreign bodies in the ultrasonography images. The images of the metal and glass foreign bodies show artefacts at the time of ultrasonography; however, these artefacts did not cause localization errors. Metal, glass, stone and graphite foreign bodies were clearly detected between bone and muscle, whereas wood, acrylic and Bakelite were not shown clearly. Metal, glass, wood, stone, graphite and Bakelite foreign bodies were clearly detected in the muscle, whereas acrylic was demonstrated with difficulty. All foreign bodies placed into the sinus were not demonstrated with ultrasonography (Figures 1c, 2c and 3c). Discussion When a foreign body accidentally enters a human body, it may locate in any of the three different regions. It may locate in an air-filled cavity such as the maxillary sinus, in soft tissue such as the tongue or between bone and muscle. 3 This study investigated these three different relevant situations in in vitro models. were placed between the corpus mandible and muscle in the sheep s head, in the sheep s tongue and in the maxillary sinus of the sheep s head. Different foreign bodies exhibit different physical properties when displayed via different visualization techniques. A foreign body might be overlooked with one method and successfully detected with another. Generally, the selection of the visualization technique to detect a foreign body should depend on its position,

MH Aras et al 77 composition and size. 3,4 Metal, glass, wood, stone, acrylic, graphite, Bakelite, thorns and sand foreign bodies have been reported in the literature. 2 Various imaging modalities, such as conventional plain radiographs, CT, MRI and ultrasonography are used to detect foreign bodies. Conventional plain radiography is usually the preferred imaging method for detecting foreign bodies. Conventional plain radiographs can determine a foreign body s position and help radiologists to determine whether the object is in a critical location or not. Although it is used frequently, additional imaging modalities may be needed for exact location. 1 CT is a standard method for imaging and localizing foreign bodies because their shape and size are accurately reproduced. It also enables the exact localization of a foreign body in the patient s body as a prerequisite to being removed surgically. 3 However, metallic artefacts are an important source of error when detecting foreign bodies with CT imaging. If a foreign body s composition is initially unknown, MRI cannot be used as the first diagnostic tool, because artefacts related to the foreign body s composition hinder the clear demonstration of iron, glass, graphite and even plastic. 5 Ultrasonography might be useful for locating superficial foreign bodies; however, it might be unsuitable for those located deep and inside the air-filled cavities. 6 In the present study, metal images in CT visualization, and metal and glass images in ultrasonography visualization showed metallic artefacts; however, these artefacts did not affect the localization. A non-radiopaque foreign body does not produce a signal on X-ray-based imaging. Hence, the composition of a foreign body determines whether it is visible on the image or not, and whether its size can influence the intensity and dimensions on imaging or not. Thus, a foreign body might be overlooked with one method and successfully detected with another method. A foreign body becomes visible when the grey-scale level at its location differs sufficiently from that of the surroundings. However, it may be invisible when its size get smaller. 1 Seven different foreign bodies were used with the dimensions of about 16160.1 cm in the study. In spite of the fact that the size of the foreign bodies used in the study were not too small, some of them were invisible in some imaging techniques. Metallic materials, except aluminium, and glass of all types are opaque on radiographs, so visualizing these materials is easier than non-opaque ones. 2 Metal, glass and stone foreign bodies can be detected with all visualization techniques in all the zones examined in this study because they are opaque on radiography. Diagnosing non-opaque objects may be more difficult. In selected cases, CT and ultrasonography offer hope for visualizing suspected non-opaque foreign objects in the body. 2 Wood, acrylic and Bakelite could not be observed with conventional plain radiography because of their insufficient opacity. However, graphite in the muscle was visible with conventional plain radiography although it could not be observed in the air and on the bone surface in this study. Usually the preferred visualizing technique is conventional plain radiography for detecting foreign bodies. 6 But this study shows that this method is not effective for observing most of the non-opaque materials. There are many advantages of ultrasonography. It causes no radiation exposure, provides real-time imaging and is relatively inexpensive. Moreover, it is easily available and can be done at the bedside. Ultrasound has shown promising results, particularly in detecting radiolucent foreign bodies. 7,8 Ultrasonography has a reported sensitivity of 95% for detection of foreign bodies. 8 Although all non-opaque materials except graphite could not be seen clearly between muscle and bone and in muscle with conventional plain radiography, and also the non-opaque materials (except graphite) were not detected clearly with CT between bone and muscle or in the muscle, ultrasonography showed a clear image of all of the tested non-opaque materials except acrylic in the muscle and Bakelite on the bone in this study. This result shows that ultrasonography is more efficient than the other methods at exploring superficial foreign bodies. However, the major disadvantage of ultrasonography occurs in the visualization of air. It is not possible to evaluate the foreign bodies visibility in air with ultrasonography. Additionally, Manthey and colleagues 9 have suggested that ultrasound should not be relied on to rule out the possibility of a retained foreign body in the distal extremities. Because location, position, size and shape of the foreign body can be reproduced accurately, CT can be used especially to deepen foreign body imaging. 1 Therefore, some authors have suggested that CT is the standard imaging technique for observing foreign bodies. 3 Nevertheless, all foreign bodies were visible in air with CT visualization in the present study; interestingly, wood could almost not be observed clearly between bone and muscle with CT. In summary, N radiopaque foreign bodies are detected with all the visualization techniques N CT is the best imaging technique for visualization of foreign bodies in air among CT, ultrasonography and conventional plain radiography N most foreign bodies with low radiopacity become less visible or almost invisible in muscle tissue and between bone and muscle tissue with CT or conventional plain radiography N ultrasonography visualizes foreign bodies with low radiopacity better, relatively, than CT does. In other words, if a foreign body is in superficial body tissue, ultrasonography can detect and localize it more efficiently than CT or conventional plain radiography.

78 MH Aras et al References 1. Eggers G, Welzel T, Mukhamadiev D, Wortche R, Hassfeld S, Muhling J. X-ray-based volumetric imaging of foreign bodies: a comparison of computed tomography and digital volume tomography. J Oral Maxillofac Surg 2007; 65: 1880 1885. 2. Hunter TB, Taljanovic MS.. Radiographics 2003; 23: 731 757. 3. Eggers G, Mukhamadiev D, Hassfeld S. Detection of foreign bodies of the head with digital volume tomography. Dentomaxillofac Radiol 2005; 34: 74 79. 4. Oikarinen KS, Nieminen TM, Makarainen H, Pyhtinen J. of foreign bodies in soft tissue in plain radiographs, computed tomography, magnetic resonance imaging, and ultrasound. An in vitro study. Int J Oral Maxillofac Surg 1993; 22: 119 124. 5. Lagalla R, Manfre L, Caronia A, Bencivinni F, Duranti C, Ponte F. Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes. Eur Radiol 2000; 10: 1338 1341. 6. Stockmann P, Vairaktaris E, Fenner M, Tudor C, Neukam FW, Nkenke E. Conventional radiographs: are they still the standard in localization of projectiles? Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: e71 75. 7. Orlinsky M, Knittel P, Feit T, Chan L, Mandavia D. The comparative accuracy of radiolucent foreign body detection using ultrasonography. Am J Emerg Med 2000; 18: 401 403. 8. Jacobson JA, Powell A, Craig JG, Bouffard JA, van Holsbeeck MT. Wooden foreign bodies in soft tissue: detection at US. Radiology 1998; 206: 45 48. 9. Manthey DE, Storrow AB, Milbourn JM, Wagner BJ. Ultrasound versus radiography in the detection of soft-tissue foreign bodies. Ann Emerg Med 1996; 28: 7 9.