C30 ISOMERS HAVE MET THEIR MATCH

Similar documents
ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Analytical and Preparative SFC Columns

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

Roc On with These Dependable LC Columns

Sepax Technologies, Inc.

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Reversed-Phase Columns (Other than ODS)

Hyper-fast & Super-rugged

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Ultra Columns. also available. ordering note

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Ultimate Core Performance to Maximize Your Investment

Ultra Columns HPLC COLUMNS

Core-Shell Technology for Proteins and Peptides

A Versatile Detector for the Sensitive and Selective Measurement of Numerous Fat-Soluble Vitamins and Antioxidants in Human Plasma and Plant Extracts

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Restek Ultra II HPLC Columns

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Paper No.: 01. Paper Title: FOOD CHEMISTRY. Module 25: Fat soluble vitamins: Properties, stability and. modes of degradation

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Agilent Technologies Prep LC Columns

LC Columns with Liquid Separation Cell Technology

Acclaim C30 Column. Standards in Isopropanol. Saponified Chicken Fat Minutes

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

HPLC Column for Structural Isomers COSMOSIL Cholester

ACE C18-AR Use the Power!

Studies on Stationary Phase Selectivity for Solid-Core Particles

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

The Raptor HILIC-Si Column

Natural Product Preparative HPLC Purification from Complex Crude Extraction Mixtures by Granular Bonded and Unbonded Silica Gel

176 YMC Chiral Columns

Fused-Core Particles:

Thermo Scientific. Acclaim C30 Columns. Product Manual. P/N: February Part of Thermo Fisher Scientific

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Physical Properties. Silica

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

A New Era in SFC Column Technology

YMC HILIC Columns for Polar Analytes

Extended Application Note

SeQuant ZIC -HILIC For all who expect more...

Choosing Preparative Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

Fortis Method Development Options

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

SeQuant ZIC -HILIC For all who expect more...

New HPLC Column Options for UHPLC

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

Vitamin Analysis by HPLC

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC

Impurity Profiling of Carbamazepine by HPLC/UV

Barry Boyes 1,2, Shujuan Tao 2, and Ron Orlando 2

GlycanPac AXR-1 Columns

Unequalled durability against water elution. % tr

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

SUMMARY, CONCLUSION & RECOMMENDATIONS

Step 3: muscle, nasal sprays and drops or used as topical

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

TSKgel Size Exclusion Chromatography Columns

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

Title Revision n date

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Am I getting the very best value from my UHPLC analyses?

HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

HxSil C18, 4.6 x 150mm, 5um (P/N 79868) 1. Oxybenzone 2. Octocrylene 3. Octyl Methoxycinnamate 4. Avobenzone (Parsol 1789) 5.

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Normal Phase Chemistries

VertiSep TM PRP. HPLC Columns. VertiSep TM PRP HPLC Columns

CONCENTRATION OF MINOR COMPONENTS IN CRUDE PALM OIL

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Raptor HILIC-Si: Simplify the Switch to HILIC

The LC Column Playbook

Lutein Esters from Tagetes Erecta

Applications Summary Waters Corporation 1

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

Columns for HPLC. Columns for HPLC

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

UHPLC / HPLC Columns Developed for Mass Spectrometry

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

Transcription:

C30 ISOMERS HAVE MET THEIR MATCH

INTRODUCING THE NEW! Built on proven Fused-Core particle technology, the is designed to deliver fast separations ideal for lipids and isomers compared to your C18. FEATURES OF High shape selectivity for hydrophobic, long-chain structurally related isomers Highly reproducible bonded phase coverage resulting in fast, highly efficient, rugged separations 100 % Aqueous Compatibility Best Applications: Fat/Water Soluble Vitamins Carotenoids Lipids Steroids QUALITY YOU CAN COUNT ON The exhibits reliable stability providing you assurance in your separations injection to injection. Column: HALO 160 Å C30, 2.7µm, 2.1 x 150mm Isocratic: 50-50 ACN/H2O Flow Rate: 1.1 ml/min. Back Pressure: 602 bar Temperature: 60 C Injection Volume: 1 µl test mix containing uracil, phenol, 1-chloro-4-nitrobenzene, and naphthalene Instrument: Shimadzu Nexera Detection: UV 254 nm, PDA

ISOMERS HAVE MET THEIR MATCH Tocopherols, a form of vitamin E, known for their antioxidant properties contain many isomers which are easily baseline separated on the compared to a C18 due to the shape selectivity property of the phase. STRUCTURE HALO C18 4 Tocopherol R1 R2 Alpha (α) CH₃ CH₃ Beta (β) CH₃ H Gamma (γ) H CH₃ Delta (δ) H H 1. δ-tocopherol 2. γ- tocopherol 3. β- tocopherol 4. α- tocopherol Columns: HALO 160 Å C30 and 90 Å C18, 2.7 µm, 4.6 x 150mm Mobile Phase A: Water Mobile Phase B: Methanol Isocratic: 95% B Flow Rate: 1.5 ml/min Temperature: 10 C Injection Volume: 1.5 μl Instrument: Agilent 1200 SL Detection: UV 290 nm, PDA CAROTENOID SEPARATION These seven carotenoids and related isomers from a commercially available vitamin formulation are easily resolved under simple mobile phase conditions. STEROID SEPARATIONS USING Glucocorticoids are a powerful form of steroid hormone both naturally produced and prescribed as a means to control a number of conditions caused by inflammation. In the example below six glucocorticoids are separated within three minutes and demonstrate excellent peak shape. Column: HALO 160 Å C30, 2.7 µm, 3.0 x 150 mm Mobile Phase A: Methanol Mobile Phase B: Ethanol Gradient: 100% A with gradient to 40% B at 20 min. Flow Rate: 0.65 ml/min Temperature: 38 C Data acquisition rate: 2.5 Hz Injection volume: 0.60 µl Instrument: Agilent 1100 Detection: UV 471 nm, PDA Data courtesy of Nature s Sunshine Products. 1. Lutein 2. cis-carotenoid 1 3. cis-carotenoid 2 4. α-carotene 5. β-carotene 6. cis-lycopene 7. Lycopene Column: HALO 160 Å C30, 2.7 µm, 4.6 x 150 mm Mobile Phase A: Water Mobile Phase B: 50/50 Acetonitrile/ Methanol Isocratic: 50% B Flow Rate: 1.5 ml/min Back Pressure: 309 bar Temperature: 60 C Injection Volume: 0.5 μl Instrument: Shimadzu Nexera X2 Detection: UV 220 nm, PDA 1. Prednisone 2. Cortisone 3. Prednisolone 4. Hydrocortisone 5. Dexamethasone 6. Corticosterone advanced-materials-tech.com

ENHANCED SELECTIVITY AND RESOLUTION FOR FAT SOLUBLE VITAMINS For a panel of fat soluble vitamins, the demonstrates superior resolution and selectivity in comparison with a commonly employed RP-Amide phase. 1. Retinyl acetate (A) 2. Delta tocopherol (E) 3. Ergocalciferol (D2) 4. Cholecalciferol (D3) 5. Alpha tocopherol (E) 6. DL-alpha-tocopherol acetate (E) 7. 2,3-trans-phylloquinone (K) 8. Retinyl palmitate (A) HALO RP-Amide Columns: HALO C30, RP-Amide, 2.7 µm, 4.6 x 150 mm Isocratic: 100% Methanol Flow Rate: 1.5 ml/min. Temperature: 30 C Injection: 2 µl Instrument: Nexera 062 Detection: UV 280 nm, PDA COMPETITIVE ADVANTAGE A column shows increased retention and baseline resolution of vitamin K1 trans and cis isomers compared to a SPP C30 column. Since the cis isomer of K1 is biologically inactive, it is important to know how much of each isomer is present in vitamin enriched products. 1. Menadione (K3) 2. Menaquinone 4 (K2) 3. 2,3-trans-phylloquinone (K1) 4. cis-phylloquinone (K1) Fully Resolved SPP C30 Unresolved 3,4 SPP C30 Columns: HALO 160 Å C30, 2.7 µm, 4.6 x 150 mm; SPP C30, 2.6 μm, 4.6 x 150 mm Mobile Phase A: Water Mobile Phase B: Methanol Isocratic: 95% B Flow Rate: 1.5 ml/min Temperature: 25 C Injection Volume: 1 μl Instrument: Shimadzu Nexera Detection: UV 280 nm, PDA

SPECIFICATIONS Ligand: Triacontyldimethyl Particle Size: 2.7 μm Pore Size: 160 Å USP Designation: L62 Carbon Load: 4.5 % Surface Area: 90 m 2 /g Endcapped: Yes Low ph Limit /Max T: 2/60 C High ph Limit/Max T: 9/40 C PART NUMBERS ANALYTICAL COLUMNS Dimensions: ID x Length (in mm) Part Number 2.1 x 20 92112-230 2.1 x 30 92112-330 2.1 x 50 92112-430 2.1 x 75 92112-530 2.1 x 100 92112-630 2.1 x 150 92112-730 2.1 x 250 92112-930 3.0 x 20 92113-230 3.0 x 30 92113-330 3.0 x 50 92113-430 3.0 x 75 92113-530 3.0 x 100 92113-630 3.0 x 150 92113-730 3.0 x 250 92113-930 4.6 x 20 92114-230 4.6 x 30 92114-330 4.6 x 50 92114-430 4.6 x 75 92114-530 4.6 x 100 92114-630 4.6 x 150 92114-730 4.6 x 250 92114-930 10.0 x 50 92110-402 10.0 x 75 92110-502 10.0 x 100 92110-602 10.0 x 150 92110-702 CAPILLARY COLUMNS Dimensions: ID x Length (in mm) Part Number 0.075 x 50 91219-402 0.075 x 100 91219-602 0.075 x 150 91219-702 0.1 x 50 91218-402 0.1 x 100 91218-602 0.1 x 150 91218-702 0.2 x 50 91217-402 0.2 x 100 91217-602 0.2 x 150 91217-702 0.3 x 50 91216-402 0.3 x 100 91216-602 0.3 x 150 91216-702 0.5 x 50 91215-402 0.5 x 100 91215-602 0.5 x 150 91215-702 1.0 x 30 92111-302 1.0 x 50 92111-402 1.0 x 75 92111-502 1.0 x 100 92111-602 1.0 x 150 92111-702 GUARD COLUMNS Dimensions: ID x Length (in mm) Guard columns, 3-pack Part Number 2.1 x 5 92112-130 3.0 x 5 92113-130 4.6 x 5 92114-130 Guard Column Holder 94900-001 INNOVATION YOU CAN TRUST PERFORMANCE YOU CAN RELY ON

FIND YOUR DISTRIBUTOR AT advanced-materials-tech.com AMT19_01_C30 HALO and Fused-Core are registered trademarks of Advanced Materials Technology, Inc.