Precisely Maximize Dose, side effects, Patient

Similar documents
CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort

PRECISE, ROBOTIC TREATMENT AS INDIVIDUAL AS EVERY PATIENT

typical IMRT fraction time and expand high definition radiotherapy anywhere in the body with the widest range of motion of the

CONFIDENCE IN THE OUTCOMES THAT MATTER MOST TO YOU

XSIGHT LUNG TRACKING SYSTEM

S Y N C H R O N Y R E S P I R A T O R Y T R A C K I N G S Y S T E M

BREAST CANCER CLINICAL ADVANTAGES

02 CyberKnife: System Overview

A UNIQUELY SMART RADIATION THERAPY SYSTEM

02 CyberKnife: Treatment Delivery

A UNIQUELY SMART RADIATION THERAPY SYSTEM

What is the CyberKnife System?

A N E W S T A N D A R D O F C A R E

Elekta Synergy Digital accelerator for advanced IGRT

Stereotactic Radiosurgery. Extracranial Stereotactic Radiosurgery. Linear accelerators. Basic technique. Indications of SRS

Cyberknife Stereotactic Treatment

EXACTRAC HIGHLY ACCURATE PATIENT MONITORING

New CyberKnife M6 Service at HKSH for Cancer Patients Shorter Treatment Time, Fewer Side Effects and Improved Patient Outcomes

Advanced tumor treatment. Precise. Comfortable. Convenient.

Advanced tumor treatment. Precise. Comfortable. Convenient. Richard & Kathy Aquebogue

CyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

The High-End Solution for Real-Time Patient Tracking

Elekta Infinity Digital accelerator for advanced treatments

Mitsubishi Heavy Industries Technical Review Vol. 51 No. 1 (March 2014)

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

CYBERKNIFE TREATMENT DELIVERY SYSTEM. Technical Specifications

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018

The future of radiation therapy. Safe and innovative options, including the CyberKnife System

Hong Kong Sanatorium & Hospital Introduces First-in-Asia TomoHD System

Introducing the TrueBeam STx system with Novalis Radiosurgery.

Advanced Tumor Treatment

The TomoTherapy System as a Tool of Differentiation in Quality and Marketability

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

Trilogy Stereotactic System Stereotactic, IMRT, and 3D CRT in one system

Delivery Quality Assurance with a High Resolution Liquid Filled Ion Chamber Array for Robotic Radiosurgery

Fiducial-Free Lung Tracking and Treatment with the CyberKnife System: A Non-Invasive Approach

Radiotherapy and Radiosurgery

A Patient s Guide to SRS

Intensity modulation techniques for spinal treatments and on-line VolumeView TM guidance

IGRT/Adaptive Gating

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

PROSTATE CANCER TREATMENT

Overview of Advanced Techniques in Radiation Therapy

Margins in SBRT. Mischa Hoogeman

Credentialing for the Use of IGRT in Clinical Trials

Advances in external beam radiotherapy

IMAGE-GUIDED RADIATION THERAPY

The role of Radiation Oncologist: Hi-tech treatments for liver metastases

Cyberknife of Long Island Robotic Radiosurgery at North Shore Radiation Therapy

Jean Pouliot, PhD Professor and Vice Chair, Department of Radiation Oncology, Director of Physics Division

Online Care, Online Control, Online Confidence

Elekta - a partner and world-leading supplier

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

2016 Billing and Coding Reference. Stereotactic Treatment Delivery

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

A method to improve dose gradient for robotic radiosurgery

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

CyberKnife robotic spinal radiosurgery in prone position: dosimetric advantage due to posterior radiation access?

TomoTherapy. Michelle Roach CNC Radiation Oncology Liverpool Hospital CNSA. May 2016

Protura Robotic Patient Positioning System. for efficiency + performance

The CyberKnife Robotic Radiosurgery System in 2010

Asynchronization. (aka MLC interplay effect with tumor motion)

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

A growing body of clinical evidence is demonstrating the benefits of delivering high doses in a small number of fractions*. Starting from classical

ABAS Atlas-based Autosegmentation

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

Monte Carlo for CyberKnife Incise TM MLC

Lung tumor motion prediction using data learned offline and during treatment

IMRT Planning Basics AAMD Student Webinar

SBRT REQUIRES: STEREOTACTIC BODY RADIOTHERAPY STEREOTACTIC BODY RADIOTHERAPY (SBRT) (SBRT) What s s in a name? Stereotactic Body Radiotherapy

Motion gating and tracking techniques: overview and recent developments

Elekta Innovation and Growth. ESTRO 2012 Capital Markets Presentation

Implementation of advanced RT Techniques

SRS Uncertainty: Linac and CyberKnife Uncertainties

See it! Trust it! Treat it!

Unrivaled, End-to-End

Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients

Radiology Oncology Surgical Robots Market Shares, Strategies, and Forecasts, Worldwide, 2016 to 2022

New Radiation Treatment Modalities in the Treatment of Lung Cancer

Subject: Image-Guided Radiation Therapy

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Treatment Planning & IGRT Credentialing for NRG SBRT Trials

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

X-Ray Guided Robotic Radiosurgery for Solid Tumors

Leksell Gamma Knife Icon A New User s Perspective

The Journey of Cyberknife Commissioning

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

LOGIQ E9 with XDclear

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

SBRT TREATMENT PLANNING: TIPS + TRICKS. Rachel A. Hackett CMD, RT(T)


Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

SRS/SRT Treatment Planning for Skull Base Meningioma

LOGIQ E9 with XDclear

Transcription:

Precisely Maximize Dose, Minimize side effects, Maximize Patient Comfort

Key Differentiators: The CyberKnife M6 Series Industry-leading precision and patient comfort Enables full-body robotic radiosurgery, SBRT and IMRT Utilizes the industry s widest range of motion for treatment in a 3D treatment space -The CyberKnife System features robotic precision and ability to deliver a wide range of non-coplanar beams accurately, without the innate restrictions of C-arm designs The CyberKnife System is the #1 recognized radiation therapy brand in the U.S. among cancer patients and caregivers* *Source: Online market research conducted in July 2013. Data on file. Images courtesy of European CyberKnife Center, Munich, Germany. 2

Key Differentiators: The CyberKnife M6 Series Precisely delivers dose with sub-millimeter accuracy, even to moving targets Hundreds of clinical papers and user testimonials attest to the CyberKnife System s capability Published studies of quality of life (QOL) post-cyberknife treatment have shown improvements in spine and lung cancer patients Spine Intra-Fraction Target Motion Dynamic tracking system moves the beam with the motion of the tumor in real-time. The CyberKnife System Image Guidance Typical IGRT System Image Guidance 1 1 Target movement (mm).5 0 -.05-1 -1.5-2 Tracking and alignment throughout treatment Target movement (mm).5 0 -.05-1 -1.5-2 Limited to only pre-treatment alignment -2.5-2.5-3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15-3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Time (minutes) Time (minutes) Target Image Capture Beam Delivery Target Shift Correction Source: Hoogeman, Mischa, ErasmusMC, Daniel den Hoed Cancer Center, Rotterdam, The Netherlands 3

Key Differentiators: The CyberKnife M6 Series Anatomy-specific tracking and treatment delivery solutions for brain, spine, lung and prostate In each case the patient lies comfortably without the discomfort of head frames, gating apparatus, breath-holding or abdominal compression The CyberKnife System offers fiducial-based and fiducial-free options for various disease sites Existing CyberKnife tracking solutions are also routinely utilized for disease sites such as liver (including metastatic disease), pancreas and other indications in the pelvis and thoracic area 4

Key Differentiators: The CyberKnife M6 Series Adjusts automatically in real-time to respiration and other changes in tumor position No patient re-alignment, no gating and no breath-hold are necessary, enabling the CyberKnife M6 System to minimize margins, spare healthy tissue and minimize side effects The robotic precision and flexibility of the CyberKnife System, along with the Synchrony Respiratory Tracking System, provide the industry s only proven technology to track, and automatically adjust in real-time to tumors that move 5

Key Differentiators: The CyberKnife M6 Series Comparison of maximum posterior angle Template Original The CyberKnife M6 System Iris & Fixed Collimator InCise Multileaf Collimator Cranial Path 18º 24º 23º Body Path 11.5º 18º 18º Cranial Original Coverage Extended Coverage with the CyberKnife M6 System Anterior View Patient Right View Patient Left View Body Original Coverage Extended Coverage with the CyberKnife M6 System Anterior View Patient Right View Patient Left View 6

Key Differentiators: The CyberKnife M6 Series Patient throughput advancements Workflow-based User Interface -Designed to improve efficiency and enhance usability, simplifying even the most complex treatments -Enables parallel tasking and visual workflow guidance Fast Treatment Planning -Anatomy-specific auto-segmentation -Performance enhancements Enhanced Image Review -Remote review with web-based TxView application -Electronic signature capability 7

Key Differentiators: The CyberKnife M6 Series InCise Multileaf Collimator (MLC): High-resolution MLC-based SBRT Accelerated treatment times and robotic tracking and correction Fine leaf projection, coupled with precise positioning accuracy and flexible conformal field shaping, can result in fewer needed beams while maintaining industry-leading treatment quality The optional InCise MLC with 10 cm x12 cm field size and full interdigitation, coupled with tracking and non-coplanar delivery, provides clinicians with even greater flexibility Robotic IMRT planning and treatment delivery MLC-based IMRT planning and treatment delivery for the InCise MLC is supported in the MultiPlan Treatment Planning System and the CyberKnife treatment delivery interface 8

The CyberKnife M6 System is a superb radiation oncology solution for treating and tracking moving targets with extreme precision and accuracy. Dwight E. Heron, MD, FACRO, FACR UPMC Cancer Center 9

UPMC Cancer Center CyberKnife user with >5,000 patients treated The CyberKnife M6 Series installed August 2013 System utilization (as of 2012): Intracranial (n=2,709) Head/Neck (n=393) Spine (n=1,049) Lung (n=450) Liver (n=12) Bone (n=38) Colon (n=4) Pancreas (n=86) Other (n=166) *CyberKnife System utilization data is obtained on a monthly basis directly from the customer. 10

We have been pleased with the efficiency of Accuray s team to replace our old CyberKnife System with the new CyberKnife M6 System. Since then, we have been able to treat patients more efficiently. Prof. Dr. med. Alexander Muacevic European CyberKnife Center Munich 11

European CyberKnife Center Munich First CyberKnife treatment: July 2005 >4,500 treatments since 2005 First CyberKnife M6 treatment: January 21, 2013 (replaced older CyberKnife unit) >400 patients have been treated on the CyberKnife M6 System since it has been commissioned Average treatment time decreased by 20% over previous CyberKnife unit Data provided courtesy of European CyberKnife Center in June 2013 Intracranial 72% Extracranial 28% Annual Average % of Disease Sites Treated A Global Summary for the CyberKnife System >57% of CyberKnife Usage is Extracranial Head/Neck 3.7% Lung 20.6% Spine 7.1% Liver 7% Pancreas 2.3% Colon 1.3% Intracranial 42.7% Other 5.8% Prostate 9.5% *CyberKnife System utilization data is obtained on a monthly basis directly from the customer (January 2011 December 2011). Not all the sites participate in this data sharing activity. 12

Summary: The CyberKnife M6 Series Industry-leading precision and patient comfort Precisely delivers dose with sub-millimeter accuracy, even to moving targets Anatomy-specific tracking and treatment delivery solutions for brain, spine, lung and prostate Existing CyberKnife tracking solutions are also routinely utilized for other disease sites, such as liver (including metastatic disease), pancreas and other indications in the pelvis and thoracic area Adjusts automatically in real-time to respiration and other changes in tumor position Extended posterior coverage Greater efficiency Patient throughput advancements Reduced treatment time Flexible configurations Scalability InCise Multileaf Collimator option: High-resolution MLC-based SBRT Supports current and future Diamond and upgrade programs including the InCise Multileaf Collimator 13

CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort CyberKnife M6 FIM System Unmatched possibilities in full-body robotic radiosurgery and radiation therapy Precisely maximize dose, minimize side effects and maximize patient comfort Advanced system geometry Enhanced design 2 MultiPlan Treatment Planning system workstations Fiducial tracking Fixed collimators Iris Variable Aperture Collimator InCise Multileaf Collimator CNS clinical package Prostate clinical package Lung and prone clinical package Clinical efficiency package OIS interface 14

CyberKnife M6 FM System Advanced full-body robotic radiosurgery with added flexibility and efficiency Advanced system geometry Enhanced design 2 MultiPlan Treatment Planning system workstations Fiducial tracking Fixed collimators InCise Multileaf Collimator CNS clinical package CyberKnife M6 FI System The premier solution for full-body robotic radiosurgery Advanced system geometry Enhanced design 2 MultiPlan Treatment Planning system workstations Fiducial tracking Fixed collimators Iris Variable Aperture Collimator CNS clinical package 15

Unmatched Precision and Patient Comfort UNITED STATES ASIA EUROPE Accuray Corporate Headquarters 1310 Chesapeake Terrace Sunnyvale, CA 94089 USA Tel: +1.408.716.4600 Toll Free: 1.888.522.3740 Fax: +1.408.716.4601 Email: sales@accuray.com Accuray Incorporated 1240 Deming Way Madison, WI 53717 USA Tel: +1 608 824 2800 Fax: +1 608 824 2996 Accuray Japan K.K. Shin Otemachi Building 7F 2-2-1 Otemachi, Chiyoda-ku Tokyo 100-0004 Japan Tel: +81.3.6265.1526 Fax: +81.3.3272.6166 Accuray Asia Ltd. Suites 1702-1704, Tower 6 The Gateway, Harbour City 9 Canton Road, T.S.T. Hong Kong Tel: +852.2247.8688 Fax: +852.2175.5799 Accuray Accelerator Technology #39 Huatai Road, Longtan Industrial Zone, Section 2 East, 3rd Ring Road, Chengdu, Sichuan 610051 People's Republic of China Accuray International Sarl Route de la Longeraie 9 (3rd floor) CH 1110 Morges Switzerland Tel: +41.21.545.9500 Fax: +41.21.545.9501 2013 Accuray Incorporated. All Rights Reserved. Accuray, the stylized logo, CyberKnife, Synchrony, Xsight, Xchange, RoboCouch, TomoTherapy, Hi Art, and TomoHD are among the trademarks and/or registered trademarks of Accuray Incorporated in the United States and other countries. TomoTherapy is a wholly owned subsidiary of Accuray. 501127.A