Spirometry and Flow Volume Measurements

Similar documents
UNIT TWO: OVERVIEW OF SPIROMETRY. A. Definition of Spirometry

DIAGNOSTIC ACCREDITATION PROGRAM. Spirometry Quality Control Plan

SPIROMETRY. Marijke Currie (CRFS) Care Medical Ltd Phone: Copyright CARE Medical ltd

S P I R O M E T R Y. Objectives. Objectives 2/5/2019

PULMONARY FUNCTION TEST(PFT)

Content Indica c tion Lung v olumes e & Lung Indica c tions i n c paci c ties

6- Lung Volumes and Pulmonary Function Tests

Respiratory Physiology In-Lab Guide

2.0 Scope: This document is to be used by the DCS staff when collecting participants spirometry measurements using the TruFlow Easy-On Spirometer.

What do pulmonary function tests tell you?

Spirometry in primary care

Analysis of Lung Function

Getting Spirometry Right It Matters! Performance, Quality Assessment, and Interpretation. Susan Blonshine RRT, RPFT, AE-C, FAARC

S P I R O M E T R Y. Objectives. Objectives 3/12/2018

Breathing and pulmonary function

Cardiovascular and Respiratory Systems

How to Perform Spirometry

PULMONARY FUNCTION. VOLUMES AND CAPACITIES

BETTER SPIROMETRY. Marijke Currie (CRFS) Care Medical Ltd Phone: Copyright CARE Medical ltd

Spirometry Training Courses. Spirometry for. Thoracic Society of Australia and New Zealand. June Developed in partnership with

2.0 Scope: This document is to be used by the DCS staff when collecting participants spirometry measurements using the TruFlow Easy-On Spirometer.

SPIROMETRY TECHNIQUE. Jim Reid New Zealand

Office Based Spirometry

PULMONARY FUNCTION TESTING. By: Gh. Pouryaghoub. MD Center for Research on Occupational Diseases (CROD) Tehran University of Medical Sciences (TUMS)

Quality Assurance Mapping Your QC Program Equipment and Test Quality. Susan Blonshine RRT, RPFT, FAARC, AE-C

PULMONARY FUNCTION TESTS

Spirometry: Introduction

#7 - Respiratory System

Patient assessment - spirometry

MSRC AIR Course Karla Stoermer Grossman, MSA, BSN, RN, AE-C

Understanding the Basics of Spirometry It s not just about yelling blow

Spirometry: FEVER DISEASE DIABETES HOW RELIABLE IS THIS? 9/2/2010 BUT WHAT WE PRACTICE: Spirometers are objective tools

Physiology lab (RS) First : Spirometry. ** Objectives :-

Spirometric protocol

PULMONARY FUNCTION TESTING. Purposes of Pulmonary Tests. General Categories of Lung Diseases. Types of PF Tests

3.0 METHODS. 3.1 Participants

behaviour are out of scope of the present review.

SPIROMETRY. Performance and Interpretation for Healthcare Professionals. Faculty of Respiratory Physiology IICMS. Version 1 April 2015

RESPIRATORY PHYSIOLOGY Pre-Lab Guide

You Take My Breath Away. Student Information Page 5C Part 1

Teacher : Dorota Marczuk Krynicka, MD., PhD. Coll. Anatomicum, Święcicki Street no. 6, Dept. of Physiology

EVect of breathing circuit resistance on the measurement of ventilatory function

Spirometry: an essential clinical measurement

Pulmonary Function Testing

#8 - Respiratory System

PFT Interpretation and Reference Values

Purpose Of This Guide

Pulmonary Function Testing. Ramez Sunna MD, FCCP

Performing a Methacholine Challenge Test

Pulmonary Function Laboratory ATS Accreditation Are you prepared? Susan Blonshine RRT, RPFT, FAARC, AE-C

SPIROMETRY METHOD. COR-MAN IN / EN Issue A, Rev INNOVISION ApS Skovvænget 2 DK-5620 Glamsbjerg Denmark

Spirometry. Obstruction. By Helen Grim M.S. RRT. loop will have concave appearance. Flows decreased consistent with degree of obstruction.

Pulmonary Function Tests. Mohammad Babai M.D Occupational Medicine Specialist

COMPREHENSIVE RESPIROMETRY

THE SOUTH AFRICAN SOCIETY OF OCCUPATIONAL MEDICINE

Lung function testing

Pulmonary Function Testing: Concepts and Clinical Applications. Potential Conflict Of Interest. Objectives. Rationale: Why Test?

Independent Health Facilities

Peak expiratory flow and the resistance of the mini-wright peak flow meter

Spirometry Workshop for Primary Care Nurse Practitioners

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

Anyone who smokes and/or has shortness of breath and sputum production could have COPD

In order to diagnose lung diseases doctors

Exercise 7: Respiratory System Mechanics: Activity 1: Measuring Respiratory Volumes and Calculating Capacities Lab Report

BiomedicalInstrumentation

Assessment of accuracy and applicability of a new electronic peak flow meter and asthma monitor

File: Spirometry-Vimeo 720p-MP3 for Audio Podcasting.mp3 Duration: 0:07:09 Date: 05/02/2014 START AUDIO

DESIGN, ANALYSIS AND IMPLEMENTATION OF SPIROMETER

Original Contributions

Standardisation of spirometry

Respiratory Training. Standard Operations Manuel For Outcome Measures Version 2.0 April Page 1 of 11

Respiratory Disease. Dr Amal Damrah consultant Neonatologist and Paediatrician

I. Subject: Medication Delivery by Metered Dose Inhaler (MDI)

GENERAL INFORMATION. Page 1 z 11

P01. Title of Guideline (must include the word Guideline (not protocol, policy, procedure etc) P01 Guideline for Peak flow recording

CIRCULAR INSTRUCTION REGARDING ESTABLISHMENT OF IMPAIRMENT DUE TO OCCUPATIONAL LUNG DISEASE FOR THE PURPOSES OF AWARDING PERMANENT DISABLEMENT

Pulmonary Function Testing

Cough Assist. Information for patients, families and carers Therapy Services

South African Thoracic Society Standards of Spirometry Committee: E M van Schalkwyk, C Schultz, J R Joubert, N W White. S Afr Med J 2004; 94:

Facility Information for Initial Assessment

Comparison of patient spirometry and ventilator spirometry

19 LUNG FUNCTION USING NDD EASY ON-PC

ADASUVE (LOXAPINE) INHALATION POWDER. EDUCATION PROGRAM for HEALTHCARE PROFESSIONALS

Office Spirometry Guide

Pulmonary Function Test

Paul M Williams*, David Honeybourneb, David S Josty*, Alan Mooreb and Keith Butterfield6

Technical Assessment of Spirometers Connected in Series

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

Coexistence of confirmed obstruction in spirometry and restriction in body plethysmography, e.g.: COPD + pulmonary fibrosis

PomPom SHOOTER. Activity Background: Common Obstructive Lung Disorders:

Angela Lorenzo MS, RRT, RPFT Adjunct Faculty, Respiratory Care Long Island University, Brooklyn

Spirometry Training Courses

ISO INTERNATIONAL STANDARD

The respiratory system

1.40 Prevention of Nosocomial Pneumonia

Chapter 3. Pulmonary Function Study Assessments. Mosby items and derived items 2011, 2006 by Mosby, Inc., an affiliate of Elsevier Inc.

Ch 16 A and P Lecture Notes.notebook May 03, 2017

Individual Study Table Referring to Part of the Dossier. Volume:

Top 5 Pitfalls of Spirometry And How to Avoid Them

Using an Inhaler and Nebulizer

Transcription:

Spirometry and Flow Volume Measurements Standards & Guidelines December 1998 To serve the public and guide the medical profession

Revision Dates: December 1998 Approval Date: June 1998 Originating Committee: Advisory Committee on Pulmonary Function Laboratories

Table of Contents 1.0 Preamble...1 2.0 Equipment...2 3.0 Procedure/Instructions for Spirometry & Flow-Volume Measurements...3 3.1 Pre-test Instructions...3 3.2 Instructions during the Patient s Performance of the Test...3 3.3 Recording Results...3 3.4 Cautionary Note...3 4.0 Calibration and Quality Control...4 4.1 Calibration for...4 4.2 Quality Control for...7 5.0 Equipment Maintenance/Repairs...8 6.0 Cleaning/Sterilization...9 7.0 Records...10 8.0 Reference Values...11 9.0 Interpretation...12 Appendix A...1 Appendix B...1 Appendix C...1 - Standards & Guidelines i CPSA: December 1998

1.0 Preamble Spirometry Spirometry is a medical test that measures the volume of air an individual inhales or exhales as a function of time. An estimate of flow, or the rate at which the volume is changing as a function of time can also be calculated with spirometry. Spirometry provides many parameters, two important ones being Forced Vital Capacity (FVC) and Forced Expiratory Volume in the first second (FEV 1 ). FVC is defined as the maximal volume of air exhaled with maximally forced effort from a position of maximal inspiration. FEV 1 is defined as the volume of air exhaled in the first second of FVC. Spirometry provides FVC, FEV 1, ratio and an estimate of flow. Flow Volume Measurements refers to systems that measure flow using a pneumotach or a heated wire system. Pneumotachs and heated wire systems are flow sensing devices that are used to integrate flow into volume. Integration is a process whereby flow (ie: volume per unit of time) at small intervals (time) is converted into volume and the volume from each interval is summed. These flow based systems provide a graphic analysis of the flow generated during the FVC maneuver and measure FVC and FEV 1 as well as other parameters. Both inspiration and expiration are measured in a flow volume loop. Indications for Spirometry or Flow Volume Measurements: To assist in the assessment of respiratory diseases such as COPD, asthma, chronic bronchitis, chest wall abnormalities, scoliosis, pulmonary fibrosis and occupational lung disease To assist in monitoring the course of some respiratory problems, the response to therapy or changes with growth/aging To provide a baseline value pre-op or pre-employment in occupations at high risk of respiratory problems Spirometry is one test of pulmonary function that does not require physician accreditation for its use or interpretation when performed in the physician s office on his or her own patients. When offered as a service to other physicians and patients however, accreditation to ensure compliance with adequate standards of performance is required. Spirometry, a test of timed vital capacity, is a useful measure of response to treatment and is one of the tests that should be part of the medical monitoring of patients with asthma and chronic lung diseases. However, the accuracy and reproducibility of spirometry results are affected by calibration and maintenance of the machine, operator technique, and effort provided by the patient. Each physician utilizing spirometry in the office is ultimately responsible to ensure that: Patient results are accurate There is a quality control program Equipment is properly maintained, calibrated and sterilized Patient results are properly recorded Staff who administer the test are properly instructed Flow Volume Measurements This procedure is not recommended as an office procedure, as the calibration of the equipment is difficult. Like all tests, the accuracy of the flow-volume loop depends on the machine s capabilities and on its calibration. Moreover, the accuracy of the flow-volume loop is affected by the person performing the test, the effort provided by the patient and, for some patients, the testing procedure itself. - Standards & Guidelines 1 CPSA: December 1998

2.0 Equipment A variety of equipment can be used to measure forced vital capacity but, regardless of the equipment used, it must meet American Thoracic Society (ATS) standards. Range and accuracy: Test Range (BTPS) Accuracy (BTPS) Flow Range (L/s) Time (s) FVC 0.5 to 8 L ± 3% of reading or ± 0.050 L, whichever is greater FEV 1 0.5 to 8 L ± 3% of reading or ± 0.050 L, whichever is greater PEF* ± 10% of reading or 0.400 L/s, whichever is greater zero to 14 15 zero to 14 1 zero to 14 * PEF Peak Expiratory Flow the maximum expiratory flow achieved with effort from a position of maximum inspiration. - Standards & Guidelines 2 CPSA: December 1998

3.0 Procedure/Instructions for Spirometry & Flow-Volume Measurements Some equipment requires that the patient first inhale to total lung capacity (TLC) before the mouthpiece is inserted and the forced expiration initiated. Other equipment functions by having the patient insert the mouthpiece prior to inhaling to TLC for the forced expiration. Regardless of the type of machine used, the patient must be actively coached to obtain accurate results. To obtain maximal values for FEV 1 and FVC, you must ensure the patient first inhales to his/her TLC and then performs the forced expiration with maximal effort. The following is an example of instructions to the patient. 3.1 Pre-test Instructions This is a test which will require your maximal effort. I am first going to ask you to fill your lungs as much as you can. Then I will tell you to completely empty your lungs as fast as you can. This will require you to use the muscles in your chest and stomach I will then repeat the instructions as you go through the test. 3.2 Instructions during the Patient s Performance of the Test With the patient breathing normally, say: After the next breath I want you to fill your lungs as much as you can. Take a big breath in-in-inkeep inhaling. At TLC say: Blow-blow-blow, keep blowing, keep blowing, keep blowing, you re almost empty, keep blowing. That s good. Come off the mouthpiece and rest. We will be doing this a few more times. 3.3 Recording Results Repeat the test until the two highest FEV 1 and FVC results agree within 200 ml. For patients with moderate to severe airway obstruction, a forced expiration can take more than 10 seconds. It is important to continue until the expiration is complete. At least three FVC tests should be done and two of these should have FEV 1 and FCV values which agree with the other FEV 1 and FVC values to within 200 ml. It is acceptable to select the highest FEV 1 and the highest FVC from different tests, but with some automatic machines you may not be able to do this. Sometimes more than three tests must be done to satisfy yourself that you have obtained the maximal effort from the patient. 3.4 Cautionary Note Some patients with asthma may develop bronchospasm during FVC testing. These patients show a progressive decrease in FEV 1, and usually in FVC as well, as repeat tests are done. In these patients the first test will usually give the best results and you will not be able to achieve reproducibility. If you suspect test-induced bronchospasm, give the patient without contraindications a ß 2 agonist and, 15 minutes later, repeat the FVC test. You should see an improvement in FEV 1 over the lowest prebronchodilator value but FEV 1 might not reach the highest prebronchodilator value. - Standards & Guidelines 3 CPSA: December 1998

4.0 Calibration and Quality Control Quality control of spirometers is closely tied to calibration, the distinction being that calibration (adjustment) may or may not be needed, but quality control must be applied on a routine basis. Calibration implies adjustment or compensation is performed whereas quality control is a means of checking the accuracy and/or precision of the device (and software) after calibration. If a known quantity of air measured by the spirometer approximates the known value then the instrument is considered accurate. If the same parameter is measured repeatedly and the consequent values are similar, then the instrument is precise. 4.1 Calibration for All devices used for both spirometry and flow volume measurements should be calibrated using a large spirometry syringe (usually 3 L) each day the machine is used. If 3 L is injected into the spirometer then the output should read 3 L± 3% or ± 90 mls. If adjustment is necessary, this is done either by software correction or by adjustment of the analog output signal. (Review the operating manual.) NOTE: The only value that can be measured accurately is FVC. The FEV 1 value will depend on how rapidly you empty the syringe through, or into the machine. When using a calibrating syringe, the manufacturer s instructions must be followed carefully. It is important that the spirometer be in Calibration Mode when calibrating so that the spirometer does not convert the volume of dry room temperature gas to that at body temperature (37 C) and saturated with water vapour. The result will be an overestimation of 4% and 9% of the volume injected. (FORM-APPENDIX A Record of Calibration) Syringe accuracy: The syringe used to check the volume calibration of spirometers must have an accuracy of at least 0.5% of full scale (15 mls for a 3 L syringe). Calibration syringes should be leak-tested periodically by trying to empty them with the outlet corked. Spirometry devices need to be checked routinely for leaks. Refer to the manual or to distributor for further information. A leak in the volume chamber will result in volume loss and inaccurate results until repairs are made. If a volume loss occurs and a leak in the volume chamber has been detected, the spirometer cannot be relied upon to give accurate results until repairs are made. Another common problem with bellows spirometers is inaccuracy resulting from sticking of the folds of the bellows. The bellows should be visually assessed during expansion with the calibration syringe to be sure the bellows inflate smoothly and evenly. If it does not, the bellows should be thoroughly rinsed and dried, or replaced with a new one. Linearity: Pneumotach systems, at extremes of flow (both high and low), may become inaccurate (i.e. 3 L injected at a high speed or a low speed may produce an inaccurate reading as opposed to 3 L injected at a moderate speed). An instrument is considered linear if its output is directly proportional to its input. Pneumotach systems must have their linearity determined whenever calibration is done. This is done by injecting the volume from a 3 L syringe at several different speeds. Most pneumotach systems compensate for this nonlinear flow signal electronically or through software corrections. The linearity is considered acceptable if the volume injected does not vary by more than ± 3%. Pneumotachs must be visually checked for moisture or other debris. This can alter its flow sensing characteristics and interfere with the spirometer s ability to detect the start or end of a test. - Standards & Guidelines 4 CPSA: December 1998

4.2 Quality Control for Checks must be done to test your technique and equipment. This is done using Standard Subjects, someone who is readily available (eg: a co-worker) and who has stable and reasonably normal lung function. The chosen standard subject must be capable of generating a peak expiratory flow of at least 550 lpm in order to test the instrument s linearity at high flows. The standard subjects should be tested every three months and records kept on the values of FEV 1 and FVC. (FORM-APPENDIX C Equipment Checks using Standard Subjects) Prior to performing these periodic standard subject tests, you must determine the normal range for the standard subject. This is done by doing at least 10 acceptable tests over a period of several days. After the tests have been done, the mean and standard deviation (SD) for FEV 1 and FVC are determined (FORM-APPENDIX B Standard Subject Normal Range). - Standards & Guidelines 7 CPSA: December 1998

5.0 Equipment Maintenance/Repairs Spirometers should have a routine maintenance schedule and records should be kept indicating the dates and description of maintenance. There should be a record of all repairs of the equipment. - Standards & Guidelines 8 CPSA: December 1998

6.0 Cleaning/Sterilization If your spirometer permits inspiration through it or through any of its parts, then the portions of the inspired pathway that are exposed to expired air must be sterilized between tests on different patients. If the machine itself is not conducive to sterilization then you must use an exchangeable filter assembly between the mouthpiece and the equipment. If mouth pieces are re-used, there must be an established protocol for cleaning that will prevent the transmission of disease. - Standards & Guidelines 9 CPSA: December 1998

7.0 Records Records should be kept for: 1. Calibration results name of person performing the calibration 2. Quality Control results from standard subjects 3. Equipment maintenance 4. Patient results: Date and time of the procedure Name of the person performing the procedure NOTE: All patient results should be filed on the patient s chart - Standards & Guidelines 10 CPSA: December 1998

8.0 Reference Values Modern microchip-containing equipment relies on a variety of normal reference values for FEV 1 and FVC. The most popular reference manuals are: Adults (>18 years old) Children (<18 years old) 1. Morris, Koski and Johnson 1. Polgar and Wang Am Rev Respir Dis Am Rev Respir Dis 1971; 103:57-67. 1979; 120: 625-695. 2. Knudson et al. 2. Hsu et al. Am Rev Respir Dis J Pediatr 1983; 127: 725-734. 1979; 95: 14-23. These predicted equations are for the caucasian population. Ethnic groups, especially of East Indian, Oriental or Polynesian descents require adjustment of the predicted equation by multiplying the predicted value for FEV 1 and FVC by 0.90. - Standards & Guidelines 11 CPSA: December 1998

9.0 Interpretation Significant Reversibility of Airway Obstruction a change of 12% and > 200 ml in the FEV 1 or FVC following bronchodilator. - Standards & Guidelines 12 CPSA: December 1998

Appendix A - Record Of Calibration Syringe Volume =. L Date FVC Date FVC Slow Medium Fast Slow Medium Fast 1. Empty the calibration syringe into the machine using slow, medium and fast emptying rates. 2. Record the resultant FVC values for the three rates of emptying. Different speeds are necessary only for instruments making flow volume measurements. If the results are outside 3% of the true value or if the rate of emptying causes values to vary by more than 3%, the machine must be serviced or replaced. - Standards & Guidelines A1 CPSA: December 1998

Appendix B - Standard Subject Normal Range Name Age Height Name Age Height Date FVC (L) FEV 1 (L) Date FVC (L) FEV 1 (L) MEAN SD MEAN +2 SD MEAN SD MEAN +2 SD For assistance in establishing a normal range for standard subjects, you may fax your data to the College at (780) 420-0651 Attention: Quality of Care Department. - Standards & Guidelines B1 CPSA: December 1998

Appendix C - Equipment Checks Using Standard Subjects Standard Subject, Name: Standard Subject, Name: FVC (L) FEV 1 (L) FVC (L) FEV 1 (L) Expected Mean ±2 SD Date Expected Mean ±2 SD Date - Standards & Guidelines C1 CPSA: December 1998