Automatic classification of mammographic breast density

Similar documents
Deep-Learning Based Semantic Labeling for 2D Mammography & Comparison of Complexity for Machine Learning Tasks

Mammographic Breast Density Classification by a Deep Learning Approach

Bianca den Dekker, MD - PhD student. Prof dr R.M. Pijnappel Prof dr H.M. Verkooijen Dr M. Broeders

Mammography limitations. Clinical performance of digital breast tomosynthesis compared to digital mammography: blinded multi-reader study

Corporate Medical Policy

Management of Palpable Abnormalities in the Breast Katerina Dodelzon, MD July 31, 2018, 7:00pm ET

The Radiology Aspects

Does the synthesised digital mammography (3D-DM) change the ACR density pattern?

Ruud Pijnappel Professor of Radiology, UMC Utrecht. Chair Dutch Expert Centre for Screening Board EUSOBI

Dense Breasts. A Breast Cancer Risk Factor and Imaging Challenge

Current Status of Supplementary Screening With Breast Ultrasound

Assessment of extent of disease: digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM)

Epworth Healthcare Benign Breast Disease Symposium. Sat Nov 12 th 2016

PGMI classification of screening mammograms prior to interval cancer. Comparison with radiologists' consensus classification.

High-Resolution Breast Cancer Screening with Multi-View Deep Convolutional Neural Networks

BI-RADS 3 category, a pain in the neck for the radiologist which technique detects more cases?

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

arxiv: v2 [cs.cv] 8 Mar 2018

Additional US or DBT after digital mammography: which one is the best combination?

Amammography report is a key component of the breast

Breast tomosynthesis reduces radiologist performance variability compared to digital mammography

CHAPTER 2 MAMMOGRAMS AND COMPUTER AIDED DETECTION

Automating Quality Assurance Metrics to Assess Adequate Breast Positioning in Mammography

A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

Digital Breast Tomosynthesis

Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection

3D Total Breast Ultrasound

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

FALSE NEGATIVES IN MAMMOGRAPHY

Since its introduction in 2000, digital mammography has become

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Screening Options in Dense Breasts. Donna Plecha, M.D. Co-Director UHCMC Breast Centers Associate Professor of Radiology Director of Breast Imaging

Emerging Techniques in Breast Imaging: Contrast-Enhanced Mammography and Fast MRI

Breast Density into Clinical Practice

Screening mammography: benefit of double reading by breast density

FDA Executive Summary

Contrast-Enhanced Spectral Mammography

Investigating the performance of a CAD x scheme for mammography in specific BIRADS categories

Digital breast tomosynthesis (DBT) occult breast cancers: clinical, radiological and histopathological features.

Digital Breast Tomosynthesis

Updates in Mammography. Dr. Yang Faridah A. Aziz Department of Biomedical Imaging University Malaya Medical Centre

Breast density: imaging, risks and recommendations

Women s Imaging Original Research

Survey of Mammography Facilities

Breast asymmetries in mammography: Management

Practitioner compression force variation in mammography : a 6 year study

Session 4: Test instruments to assess interpretive performance challenges and opportunities Overview of Test Set Design and Use

«àπ π â Õ μ «å «π Áß μâ π π ßæ π ª

Purpose. [Purpose] [Introduction] Architectural distortion on mammography

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Current Strategies in the Detection of Breast Cancer. Karla Kerlikowske, M.D. Professor of Medicine & Epidemiology and Biostatistics, UCSF

The value of the craniocaudal mammographic view in breast cancer detection: A preliminary study

Observer Agreement Using the ACR Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, First Edition (2003)

Challenges to Delivery of High Quality Mammography

Women s Imaging Original Research

GE Healthcare. Look differently. Invenia ABUS Automated Breast Ultrasound

Electrical impedance scanning of the breast is considered investigational and is not covered.

MAMMOGRAM AND TOMOSYNTHESIS CLASSIFICATION USING CONVOLUTIONAL NEURAL NETWORKS

Why it matters and what to do

The GE Breast Health Advantage

Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A Comparison

Women s Imaging Original Research

Breast Imaging Donald L. Renfrew, MD

Breast Density. Information for Health Professionals

CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

Breast cancer detection: radiologists performance using mammography with and without automated whole-breast ultrasound

Jing Zhang, PhD, Lars J. Grimm, MD, MHS, Joseph Y. Lo, PhD, Karen S. Johnson, MD,

Breast Tomosynthesis. What is breast tomosynthesis?

Disclosures. Breast Cancer. Breast Imaging Modalities. Breast Cancer Screening. Breast Cancer 6/4/2014

COMPUTERIZED CALCULATION OF BREAST DENSITY: OUR EXPE- RIENCE FROM ARCADIA MEDICAL IMAGING CENTER

BI-RADS classification in breast tomosynthesis. Our experience in breast cancer cases categorized as BI-RADS 0 in digital mammography

Digital Breast Tomosynthesis Ready for Routine Screening?

Fuzzy logic in computer-aided breast cancer diagnosis: analysis of lobulation 1

Women s Imaging Original Research

TOMOSYNTHESIS: WORTH ALL THE HYPE?

Population Prospective. Big Picture

Fundamentals of Breast Tomosynthesis

Assessing Viewing Pattern Consistency in Mammogram Readers

Outline. Digital Breast Tomosynthesis: Update and Pearls for Implementation. Tomosynthesis Dataset: 2D/3D (Hologic Combo Acquisition)

Effect of Mammographic Screening Modality on Breast Density Assessment: Digital Mammography versus Digital Breast Tomosynthesis

Breast Density. Update 2018: Implications for Clinical Practice

POSITIONING ACR REQUIREMENTS IMAGE REVIEW CATEGORIES DEFICIENCIES IN POSITIONING ACR REQUIREMENTS 3/28/2016 NUMBER 1 REASON FOR ACR FAILURE

Financial Disclosures

Automated Breast Density Assessment

Title: Breast Screen Reader Assessment Strategy (BREAST): UK Collaboration

Localization of Breast Lesion Using Mammographic-Basic Views

Can Digital Breast Tomosynthesis(DBT) Perform Better than Standard Digital Mammography Workup in a Breast Cancer Assessment Clinic?

Mammographic Density Estimation by Volpara software: Comparison with Radiologists' visual assessment and relationship with BI-RADS category

BIRADS 3 and 4 lesions viewed by ultrasound and not seen in digital mammograms and tomosynthesis.

The Dilemma of Breast Density in Screening

now a part of Electronic Mammography Exchange: Improving Patient Callback Rates

SCREENING FOR BREAST CANCER BREAST IMAGING

High Risk Screening: A Multimodality Approach

Radiologist Assessment of Breast Density by BI-RADS Categories Versus Fully Automated Volumetric Assessment

HEALTHCARE AI DEVELOPMENT CYCLE

ACR PRACTICE GUIDELINE FOR THE PERFORMANCE OF DIAGNOSTIC MAMMOGRAPHY

In multiple published papers digital breast

Research summary. European Congress of Radiology 2015

Role of ultrasound in breast cancer screening. Daerim St. Mary Hospital Department of Surgery, Breast care center Dongwon-Kim, M.D.

Policy Library Clinical Advantages of Digital Breast Tomosynthesis in Symptomatic Patients

Transcription:

Deep Learning Day 2018 Automatic classification of mammographic breast density PD Dr. Cristina Rossi cristina.rossi@usz.ch Institute of Diagnostic and Interventional Radiology, University Hospital Zurich

Deep Learning Day 2018 Automatic classification of mammographic breast density Alexander Ciritsis, Cristina Rossi, Ilaria De Martini, Matthias Eberhard, Magda Marcon, Anton S. Becker, Nicole Berger, Andreas Boss Institute of Diagnostic and Interventional Radiology, University Hospital Zurich

Contents Machine Learning on Medical Imaging Data - Radiologists Perspective Automatic classification of mammographic breast density Can we apply this science?

Machine Learning on Medical Imaging Data - Radiologists Perspective Courtesy of Christian Blüthgen, MD MSc

Machine Learning on Medical Imaging Data - Radiologists Perspective Acquire Patient Information Select Adequate Modality Acquire Images Describe Findings Integrate Knowledge Classify Act/Recommend Courtesy of Christian Blüthgen, MD MSc

Machine Learning on Medical Imaging Data - Radiologists Perspective Understand the clinical problem Target those tasks that profit from standardization are tedious (but still require a long training period) Provide transparent solutions that mimic the human decision making process are adaptable to the clinical workflow

Contents Machine Learning on Medical Imaging Data - Radiologists Perspective Automatic classification of mammographic breast density Can we apply this science?

Automatic classification of mammographic breast density (BD) Women with high BD have a 2- to 6-fold increased risk of developing breast cancer 1 For dense breast the sensitivity of the screening mammography drops from 87% to 63% 2 Patients with high BD require additional imaging, such as tomosynthesis, ultrasound or breast MR to increase the cancer detection chances 3 www.ncbi.nlm.nih.gov/pubmedhealth 1 Boyd et al. Mammographic density and the risk and detection of breast cancer. N Engl J Med. 2007;356(3):227-36 2 Boyd NF. Mammographic density and risk of breast cancer. Am Soc Clin Oncol Educ Book. 2013. 3 Berg et al. Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer. JAMA. 2008;299(18):2151-63

Automatic classification of mammographic breast density (BD) Mammographic Breast density ACR a-d. American College of Radiology BIRADS catalogue, 5th edition ACR-BD classification is observer-dependent (inter-reader agreement ranging between 0.43 and 0.89) 1 Radiologists routinely reading mammographies perform better 2 1 Ekpo et al. Assessment of Interradiologist Agreement Regarding Mammographic Breast Density Classification Using the Fifth Edition of the BI-RADS Atlas. AJR Am J Roentgenol. 2016;206(5):1119-23. 2 Berg et al. Breast Imaging Reporting and Data System: inter- and intraobserver variability in feature analysis and final assessment. AJR Am J Roentgenol. 2000;174(6):1769-77

Automatic classification of mammographic breast density (BD) Data: 20,578 diagnostic mammography views from 5,221unique patients (age = 58±12 years) acquired between 2012 and 2013 Labeling: views of the single patient were linked to the ACR BI-RADS density from the corresponding radiological report using a home-written text searching MATLAB script (Release 2013b, MathWorks, Natick, MA, USA). Balanced dataset: 12, 932 labeled mammography views were successfully linked to the ACR BI-RADS density from the corresponding radiological report. After data augmentation (ImageDataGenerator Keras) a balanced training and validation dataset subdivided into 4 classes composed of n = 22,414 MLO projections and n = 22,439 CC projections was available.

Automatic classification of mammographic breast density (BD) Hardware and software: consumer-grade desktop computer equipped with an Intel i7-7700 CPU with 16 GB RAM and an NVIDIA 1080 GTX graphics processing unit with 8 GB graphics RAM. The computer was running Ubuntu Linux 16.04 with Tensorflow 1.0.1.

Automatic classification of mammographic breast density (BD) Performance over the validation dataset View Accuracy Number of epochs Computation time Mediolateral Oblique 90.9 % 91 20.3 hours Cranio-Caudal 90.1 % 94 21.6 hours

Automatic classification of mammographic breast density (BD) Test against the expert readers consensus: CC view ROC space Cohen s kappa Confusion Matrix A B C D A 94.7% 5.3% 0.0% 0.0% B 20.7% 79.3% 0.0% 0.0% C 0.0% 2.7% 75.7% 21.6% D 0.0% 0.0% 0.0% 100.0%

Automatic classification of mammographic breast density (BD) Test against the expert readers consensus: MLO view ROC space Cohen s kappa Confusion Matrix A B C D A 89.5% 10.5% 0.0% 0.0% B 9.1% 87.9% 3.0% 0.0% C 0.0% 0.0% 100.0% 0.0% D 0.0% 0.0% 8.7% 91.3%

Automatic classification of mammographic breast density (BD) The dcnn allows for accurate classification of breast density based on the ACR BI-RADS system. The performance of the dcnn are comparable to those of experienced radiologists The proposed technique may allow accurate, standardized, and observer independent breast density evaluation of mammographies.

Contents Machine Learning on Medical Imaging Data - Radiologists Perspective Automatic classification of mammographic breast density Can we apply this science?

False Can we apply this science? Mammography MD>c True Ultrasound Imaging Data http://www.diagnosticimaging.com/radiology-comics/ Diagnosis

Can we apply this science? Applied sciences: sciences that are put to practical use. (Collins) Standardized assessment of high BD allows the prompt schedule of the US Number of recall examinations Efficient workflow improves patient s perception of the safety and efficiency of the provided care Efficiency radiographer s workflow The reduction of recall examinations is cost saving and relives the psychological burden on patient Patient satisfaction

Project name Artificial Intelligence in oncological Imaging Network Thank you Grazie mille