LC/QTOF Discovery of Previously Unreported Microcystins in Alberta Lake Waters

Similar documents
LC/QTOF Identification of Microcystin Variants in Cell- Bound Algae from the San Francisco Estuary

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

Ultra High Definition Optimizing all Analytical Dimensions

Sue D Antonio Application Chemist Cedar Creek, TX

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Agilent s LC/MS Portfolio and Applications Examples

Metabolomic and Proteomics Solutions for Integrated Biology. Christine Miller Omics Market Manager ASMS 2015

Metabolite identification in metabolomics: Database and interpretation of MSMS spectra

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Metabolite identification in metabolomics: Metlin Database and interpretation of MSMS spectra

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry

Edgar Naegele. Abstract

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Characterization of an Unknown Compound Using the LTQ Orbitrap

Dividing up the data

For personal use only. Please do not reuse or reproduce

Comparison of mass spectrometers performances

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows.

MS/MS Scan Modes. Eötvös University, Budapest April 16, MS/MS Scan Modes. Árpád Somogyi. Product Ion Scan Select. Scan. Precursor Ion Scan Scan

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides

Simultaneous Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

How to Use TOF and Q-TOF Mass Spectrometers

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Introduction to the Oligo HTCS Systems. Novatia, LLC

Towards High Resolution MS in Regulated Bioanalysis

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

SYNAPT G2-S High Definition MS (HDMS) System

Amadeo R. Fernández-Alba

High Performance Gas Chromatography Mass Spectrometry in Addressing the Challenges of Metabolomic Studies Separation in Time and Mass

METABOSCAPE A METABOLITE PROFILING PIPELINE DRIVEN BY AUTOMATIC COMPOUND IDENTIFICATION

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

ANALYTICAL REPORT 1, 2

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

Mass spectra of peptides and proteins - and LC analysis of proteomes Stephen Barnes, PhD

SimLipid 3.5. Manual PREMIER. Biosoft International Corina Way, Palo Alto, CA Tel: (650) FAX: (650)

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

ANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one

Lecture 3. Tandem MS & Protein Sequencing

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.

Comprehensive Food Profiling Combining High Resolution LC/MS and GC/MS Analyses

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Sample Preparation is Key

Supporting information

Introduction to Peptide Sequencing

Conflict of Interest Statement

ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine.

Mass Spectrometry Infrastructure

New Developments in LC-IMS-MS Proteomic Measurements and Informatic Analyses

MS/MS APPROACHES TO CLINICAL TESTING FOR INBORN ERRORS OF METABOLISM

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

The New 6495 Triple Quadrupole LC/MS

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

ANALYTICAL REPORT 1, 2

Biological Mass spectrometry in Protein Chemistry

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Sunil Kulkarni Product Specialist Agilent Technologies

ANALYTICAL SCALE AGILENT LCMS SYSTEMS OPERATIONAL QUALIFICATION

Components of a Mass Spectrometer

Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Nature Biotechnology: doi: /nbt Supplementary Figure 1

Use of RapidFire/MS for Metabolomics. - from untargeted to targeted and Pathway driven analysis. RapidFire/MS. Moritz Wagner Agilent Technologies

The use of mass spectrometry in lipidomics. Outlines

Real-time PK Measurement of the Chemotherapeutic Drug Melphalan in Whole Blood by a Novel PaperSpray Mass Spectrometry

Identification of Imidacloprid Metabolites in Onions Using High Resolution Accurate Mass Spectrometry (LC/Q-TOF MS) and Accurate Mass Tools

Quantification with Proteome Discoverer. Bernard Delanghe

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Kazusa DNA Res Inst. Daisuke Shibata

The Evolution GC-MS/MS Triple Quadrupole System

Comparison of Relative Quantification of Monoclonal Antibody N-glycans Using Fluorescence and MS Detection

Research to Routine Workflows for Large and Small Molecules using the Q Exactive HR/MS

A Very Unusual Doubly Charged Ion in the Mass Spectrum of a Phosphate (James Little*, T. Huret, Bob Hale)

One Gene, Many Proteins. Applications of Mass Spectrometry to Proteomics. Why Proteomics? Raghothama Chaerkady, Ph.D.

Measuring Lipid Composition LC-MS/MS

Biomolecular Mass Spectrometry

Multiple Reaction Monitoring for Direct Quantitation of Intact Proteins using a Triple Quadrupole Mass Spectrometer

Moving from targeted towards non-targeted approaches

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Learning Objectives. Overview of topics to be discussed 10/25/2013 HIGH RESOLUTION MASS SPECTROMETRY (HRMS) IN DISCOVERY PROTEOMICS

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid

Transcription:

LC/QTOF Discovery of Previously Unreported Microcystins in Alberta Lake Waters Ralph Hindle Vogon Laboratory Services Ltd. Cochrane, Alberta, Canada Xu Zhang David W. Kinniburgh Alberta Centre for Toxicology 1

Vogon Laboratory Services Ltd. Calgary, Alberta, Canada

Vogon Laboratory Services Ltd. Calgary, Alberta, Canada

Vogon Laboratory Services Ltd. Cochrane, Alberta, Canada

Kananaskis Provincial Park

Confirmation Request 1. Identify and quantitate targeted microcystins (7 compounds) in lake water 2. Identify unknown peak in lake waters: a) Lake Water A (corresponding to nominal mass of YR) b) Lake Water B (corresponding to nominal mass of LY)

General Microcystin Structure Over 70 microcystins have been identified in the literature Microcystin Provided by ACFT X Z Formula Neutral Mass LR Leucine Arginine C 49 H 74 N 10 O 12 994.5488 Desmethyl LR Leucine Arginine C 48 H 72 N 10 O 12 980.5331 RR Arginine Arginine C 49 H 75 N 13 O 12 1037.5658 YR Tyrosine Arginine C 52 H 72 N 10 O 13 1044.5280 LW Leucine Phenylalanine C 54 H 72 N 8 O 12 1024.5270 LF Leucine Tryptophan C 52 H 71 N 7 O 12 985.5161 HtyR Homotyrosine Arginine C 53 H 74 N 10 O 13 1058.5437

Microcystin-LR Structure (Most common microcystin reported) C 49 H 74 N 10 O 12 Mass = 994.5488 Glu Mdha Adda O CH 3 CH 3 H 3 C O HO HN NH C O O H N O CH 3 N O NH O CH 2 H 3 C CH 3 HN H N C HO O O O CH 3 CH 3 Ala Leucine (L) HN NH MeAsp Arginine (R) NH 2

QQQ MRM Parameters a Microcystin Precursor b (m/z) Product Ion (m/z) LR 995.6 135.2 213.2 Desmethyl-LR 981.5 135.2 213.2 RR 520.0 135.2 213.2 YR 1045.5 135.2 213.2 LW 1025.5 135.2 213.2 LF 986.5 135.2 213.2 HtyR 1059.5 135.2 213.2 Collision Energy (V) 80 80 80 80 30 40 80 70 80 60 70 50 80 70 a These patterns are useful, as they show that all supplied MCs fragment to the same 2 diagnostic ions b RR readily shows a doubly charged precursors. Depending on source conditions, other MCs can show either singly or doubly charged ions. 10

Common Microcystin Fragments m/z = 135.2 and 213.2 Glu + Mdha = C 9 H 13 N 2 O 4 + m/z = 213.0870 C 9 H 11 O + m/z = 135.0804

LC-QTOF Instrumentation HPLC Mass Spectrometer 1290 Binary Pump 6540B QTOF 1200 Degasser Jet Stream Electrospray Source 1290 Autosampler 1290 TCC 13

Transforming Data Acquire Data LC/MS Find Compounds Compare Compounds Identify Compounds TOF MS Q TOF MS/MS QQQ MS/MS Single Q MS Trap MS n Find Compounds MFE Find Compounds LMFE (Proteins) Find Compounds Auto MS/MS Compare compounds between samples Metabolite ID Mass Profiler Compare compounds between 2 sample sets Mass Profiler Mass Profiler Professional Protein DB Search Spectrum Mill Mascot Others (via mzxml, mzdata) Accurate Mass and RT (AMRT) Database Search Endogenous Metabolites (METLIN) Food, Forensics, Environmental Find Compounds Targeted MS/MS Find Compounds By Formula Compare compounds between >2 sample sets Mass Profiler Professional Molecular Formula Generation (MFG) Via accurate mass MS and MS/MS MS/MS Structural Correlation (MSC) via accurate mass Future Tools Fully or Partially Automated 14

Find By Formula Parameters 16

Level 3 Calibrator (10 ng/ml) 17

Time of Flight MS Spectra

Database Score Monoisotopic mass (varies in ppm) Isotope distribution (varies in %) Isotope spacing (varies in ppm) Score based on: Mass match measured versus given. Abundance score abundance pattern of measured isotope cluster compared with values predicted from the proposed formula. Spacing match how the m/z spacing between the lowest m/z ion and the A+1 and A+2 ions compared with the values predicted from the proposed formula.

Score Evaluation for Find by Formula RT Name Mass m/z Score Diff from Tgt (ppm) Ions Flags (Tgt) Flag Severity (Tgt) 4.60 HtyR 1058.5429 1059.5505 98.4 0.7 14 Pass 4.62 YR 1044.5275 1045.5347 99.3 0.5 18 Pass 4.68 LR 994.5487 995.5560 99.2 0.1 15 Pass 4.80 RR 1037.5654 519.7900 99.2 0.4 16 Pass 4.87 dm LR 980.5332 981.5404 99.7 0.1 13 Pass 5.27 LW 1024.5265 1025.5340 99.3 0.5 8 Pass 5.40 LF 985.5159 986.5232 99.8 0.2 12 Pass Scores range from 98.4 99.8 Mass error all < 1 ppm; up to 18 ions found to help confirm molecular formula MassHunter table includes Flags and Severity ratings to help interpret results (no flags identified in this data)

Compounds-at-a-Glance (20 ul) 0.1 ng/ml 1 ng/ml 10 ng/ml HtyR YR LR RR

Calibration Curves

Calibration Accuracies Creating a Quant method is easy: Review the data in Qual Export a Compound Exchange Format (CEF) file Select New Method from File in Quant Add calibration levels That s it!

Water Sample Results Lake A HtyR YR LR RR Cal 1 Cal 2 Cal 3 Lake A Lake B

Lake A YR Investigation in Qual The raw spectrum shows that the unknown contains a distinct A ion at 1045.5342 This is 0.5 ppm mass error and score of 99.4 for YR formula: C 52 H 72 N 10 O 13 Because RT is wrong, suspect structural isomer Run Targeted MS/MS on each sample (next slide)

YR vs Unknown Compound: MS/MS Notable ions missing from Lake A compound: 127.0862 155.0803 157.1094 213.0864 Notable ions present in Lake A compound: 150.0904 361.1730 Conclusion: Unknown peak is not YR

Zoom in on common MC fragments - 135 135.0804 = C 9 H 11 O + De methylation is common in microcystins Two 135 ions are present in both YR and in unknown compound in Lake A, from 2 different fragments Indicates that Adda group is intact and not de methylated O CH 3 H 3 C CH 3 135.1168 = C 10 H 15 + HO C O HN O NH Z O CH 3 O N O CH 2 H 3 C CH 3 HN C HO O NH X O

Zoom in on common MC fragments - 213 Glu + Mdha = C 9 H 13 N 2 O 4 + m/z = 213.0870 De methylation can also occur on Mdha group 213.0870 ion is very low in Lake A unknown Indicates a de methylated microcystin

Zoom in on common MC fragments - 199 Predict: C 8 H 11 N 2 O 4+ fragment ion from [Mdha CH 2 ] de methylation Result: Found in Unknown, not in YR Des methyl HtyR has same formula as YR, and so is a strong candidate If 1045.5 > 213.1 is monitored as qualifier ion by QQQ, ratio will be low compared to YR standard

Additional unknowns detected Lake A MS only PCD of 52 microcystins (in house) Mass Tolerance: 5 ppm Min Score: 70 H + adduct required

Additional unknowns detected Lake B MS only PCDL of 52 microcystins (in house) Mass Tolerance: 5 ppm Min Score: 70 H + adduct required

1. All calibrators were detected at 0.1 ng/ml on 6540 QTOF 2. Calibration curves were linear (R 2 > 0.998) 3. Microcystins confirmed: 1. Lake A: dm-lr = 15.8 ng/ml 2. Lake B: LR = 0.4 ng/ml 4. Identify unknown peak in lake waters: I. Lake Water A II. Summary i. HtyR tentatively identified, corresponding to nominal mass of YR ii. 7 additional MCs were tentatively identified Lake Water B i. suspected LY confirmed to be different compound ii. 7 additional MCs were tentatively identified 5. In-house PCDL of 52 compounds was created from WHO list and used to tentatively identify previously unreported microcystins

Acknowledgements ACFT sample prep staff