Medical Review Approaches to the Diagnosis of Liver Fibrosis

Similar documents
Preliminary clinical experience with Shear Wave Dispersion Imaging for liver viscosity

Byung Ihn Choi, M.D. Department of Radiology Seoul National University Hospital

iu22 Liver Shear Wave ElastPQ

PROPOSTA DI UN NUOVO ALGORIMO PER LA DIAGNOSI ECOGRAFICA DELLE MALATTIE CRONICHE DEL FEGATO

shear wave elastography

Non-Invasive Assessment of Liver Fibrosis. Patricia Slev, PhD University of Utah Department of Pathology

Ultrasound elastography in abdominal imaging

Liver elastography ultrasound cpt code

Simplifying liver assessment in internal medicine

The role of non-invasivemethods in evaluating liver fibrosis of patients with non-alcoholic steatohepatitis

Improved Hepatic Fibrosis Grading Using Point Shear Wave Elastography and Machine Learning

NONINVASIVE IMAGING METHODS FOR ASSESSMENT OF LIVER DAMAGE IN NASH

Making Waves to Detect Illness. How elastography is helping doctors avoid the biopsy needle

Evaluation of Liver Fibrosis using ShearWave Elastography on Aixplorer

Non-Invasive Testing for Liver Fibrosis

Intuitive. Intelligent. Innovative. General Imaging

Pretreatment Evaluation

Intuitive. Intelligent. Innovative. General Imaging

LOGIQ E9 Shear Wave Elastography

Evaluation of liver and spleen stiffness using a ultrasound guided method: Accuracy of ARFI(R) measurements in liver disease patients

Research Elastography: Liver

Pretreatment Evaluation

Quantitative Imaging Biomarkers in Ultrasound Elasticity Imaging. Timothy J Hall Medical Physics Department University of Wisconsin AIUM 2012

Intuitive. Intelligent. Innovative. General Imaging

Elastography in the. technically difficult patient. EPIQ ultrasound system. Ultrasound

The role of ARFI and APRI in diagnosis of liver fibrosis on patients with common chronic liver diseases

Evaluation of liver and spleen stiffness using a ultrasound guided method: Accuracy of ARFI(R) measurements in liver disease patients

HEP DART 2017, Kona, Hawaii

Pretreatment Evaluation

Augmentation of the In Vivo Elastic Properties Measurement System to include Bulk Properties

DISCLOSURES. This activity is jointly provided by Northwest Portland Area Indian Health Board and Cardea

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Ultrasound Committee Activities

Seeing the Unseen Clinical advances and future directions of SMI

MR Elastography of Liver

LOGIQ S8 XDclear 2.0 Liver Procedures

Evolution and Revolution of System Architecture with New Generation Technology

Transient elastography the state of the art

Diagnostic TRUS Elastography of the Prostate

Seeing the Unseen Clinical advances and future directions of SMI

Does elastography change the indication to biopsy? IBDC

Acoustic Radiation Force Based Imaging: An Overview

ULTRASOUND IN CHRONIC LIVER DISEASE

Tissue Strain Analytics Virtual Touch Tissue Imaging and Quantification

NONINVASIVE TECHNIQUES FOR EVALUATION AND MONITORING OF CHRONIC LIVER DISEASE

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

LOGIQ E9 Shear Wave Elastography

LOGIQ S8 XDclear 2.0. Simply Amazing

CASES FOR DISCUSSION. Yohannes B

Medical technologies guidance Published: 23 September 2015 nice.org.uk/guidance/mtg27

MRI OF LIVER FIBROSIS

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Hepatic Imaging: What Every Practitioner Should Know

LOGIQ E9 Shear Wave Elastography

JPGN Journal of Pediatric Gastroenterology and Nutrition Publish Ahead of Print

Prediction of Hepatocellular Carcinoma Incidence Risk by Ultrasound Elastography

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Performance Evaluation of Ultrasound Systems: Advanced Methods and Applications

Acoustic radiation force impulse elastography in distinguishing hepatic haemangiomata from metastases: preliminary observations

Elastography. White Paper

Diabetes Liver Screen

Liver Disease Assessment Among PWID: The Role of Transient Elastography

Non-invasive diagnosis of hepatitis B virus-related cirrhosis

What effects will proximal or distal disease have on a waveform?

Pushing the boundaries

Dr Emma Chung. Safety first - Physical principles for excellent imaging

New Tools for Assessing Disease Sererity, progression and regression in HBV and HCV

In Search of New Biomarkers for Nonalcoholic Fatty Liver Disease

Elastography to Assess the Stage of Liver Fibrosis in Children: Concepts, Opportunities, and Challenges

Daily inspiration. Ultrasound system HS70A SAMSUNG MEDISON CO., LTD. Scan code or visit to learn more

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

NON INVASIVE ASSESSMENT OF LIVER FIBROSIS : FIBROSCAN

Ultrasonic Tissue Strain Imaging

Liver Ultrasound - Beyond the Basics. Pamela Parker Lead Sonographer

New York State HCV Provider Webinar Series

Real-time elastography as a noninvasive assessment of liver fibrosis in chronic hepatitis C Egyptian patients: a prospective study

Innovations in Ultrasound & Breast Cancer Imaging

Transient elastography in chronic liver diseases of other etiologies

Liver Stiffness in Patients After the Fontan Procedure is Correlated with Age at Time of Surgery and Time since Surgery

DISCLOSURE. Myocardial Mechanics. Relevant Financial Relationship(s) Off Label Usage

National Horizon Scanning Centre. Enhanced Liver Fibrosis Test (ELF) for evaluating liver fibrosis. June 2008

Transient elastography in chronic viral liver diseases

Clinical Medicine Review

Muscle-Tendon Mechanics Dr. Ted Milner (KIN 416)

Blood Pressure Monitor PASESA

Hepatology for the Nonhepatologist

Noninvasive Diagnosis and Staging of Liver Disease. Naveen Gara, MD

DISCLOSURES. This activity is jointly provided by Northwest Portland Area Indian Health Board and Cardea

Modern liver imaging techniques - A new era in liver ultrasound

Functional liver imaging Bernard Van Beers

Aixplorer MultiWave Ultrasound System An Innovation in Breast Ultrasound Imaging

Faculty Disclosure. Objectives. Cirrhosis Management for the Family Physician 18/11/2014

A Comparative Study of Shear-Wave Elastography and Strain Elastography on a Breast Phantom for Diagnosis of Tumor and Cyst

Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography

Learning Objectives. After attending this presentation, participants will be able to:

Biomarkers of PSC. Steve Helmke, Ph.D.

Elastosonography. Prof. Massimo Midiri Direttore Istituto di Radiologia Policlinico Universitario Paolo Giaccone Diagnostica per Immagini, - Palermo

Soft tissue biomechanics

Review Article. JSUM Ultrasound Elastography Practice Guidelines Breast

Transcription:

Medical Review Approaches to the Diagnosis of Liver Fibrosis Hiroko Iijima Department of Hepatobiliary and Pancreatic Disease Ultrasound Imaging Center, Hyogo College of Medicine

Hiroko Iijima Department of Hepatobiliary and Pancreatic Disease, Ultrasound Imaging Center, Hyogo College of Medicine Dr. Hiroko Iijima graduated from Hyogo College of Medicine in 1983 and joined the Third Department of Internal Medicine of Hyogo College of Medicine as a clinical fellow in the same year. She was appointed assistant in the Third Department of Internal Medicine of Hyogo College of Medicine in 1996 and lecturer in the Fourth Department of Internal Medicine of Tokyo Medical University in 2000. In 2003, Dr. Iijima was appointed clinical professor in the Department of Radiology at Toronto General Hospital of the University of Toronto and visiting professor in the Department of Medical Biophysics at the Sunnybrook Research Institute of the University of Toronto. She was appointed associate professor in the Medical Imaging Center and associate professor in the Division of Hepatobiliary and Pancreatic Disease of the Department of Internal Medicine of Hyogo College of Medicine in 2005. Since 2008, Dr. Iijima has served as the director of the Ultrasound Imaging Center and a professor in the Department of Hepatobiliary and Pancreatic Disease. INTRODUCTION The conventional methods employed in diagnostic ultrasound examinations for chronic liver diseases include the assessment of B-mode images, the evaluation of nonuniformity in the Rayleigh distribution (ASQ*), and the estimation of disease progression based on indices of congestion as well as hepatic vein waveforms obtained by Doppler scanning. Following the introduction of ultrasound contrast agents, estimation of the severity of liver diseases based on the times required for contrast agent to reach the hepatic arteries, portal vein, and hepatic veins and functional diagnosis based on the phagocytic activity of Kupffer cells have also been performed. * Available outside of the USA In this paper, I would like to discuss the assessment of liver stiffness using shear waves, which is one of the recently developed elastography methods that is attracting a great deal of interest. BACKGROUND OF THE DEVELOPMENT OF ELASTOGRAPHY When conventional methods based on the observation of speckle patterns in B-mode images are used for the diagnosis of liver diseases, the diagnosis of F2 and F1 stages is very difficult. There have been attempts to perform tissue diagnosis using images of the liver surface, but these are morphologic methods and provide no more information than the estimation of liver stiffness by manual palpation. Poke one point and observe the vibration at another point. Pressure needed to induce 100% strain in the target = Modulus of elasticity (Young's Modulus) E [kpa] Shear wave propagation velocity = Shear velocity Vs [m/s] Figure 1: Relationship between shear velocity and tissue stiffness. 2 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

Toshiba Medical Systems Corporation has implemented a method known as Acoustic Structure Quantification (ASQ) for the assessment of nonuniformity within the liver in their diagnostic ultrasound system Aplio TM. However, this function only analyzes the uniformity of the liver parenchyma. Currently, the gold standard for the diagnosis of liver diseases is considered to be liver biopsy. However, liver biopsy suffers from a number of problems and limitations, including the risk of complications, invasiveness, high cost, and the possibility of sampling error. Blood chemistry examinations are also employed, but their diagnostic accuracy is not particularly high. Clinically, it is important to determine the risk of cancer and the need for antiviral treatment in each individual patient. For patients with hepatitis C, it is also necessary to determine whether treatment can be postponed until direct-acting antiviral (DAA) agents become available on the market. Assessment of the degree of fibrosis and inflammation is important for these clinical applications. Given this background, elastography, which can be used to assess hepatic fibrosis and stiffness noninvasively, has been developed and is increasingly employed in the clinical setting. TWO MAIN TRENDS IN ELASTOGRAPHY There are two types of elastography: strain elastography, which assesses the degree of strain when a given amount of force is applied to the liver, and shear wave elastography, which assesses the velocity of shear wave propagation within the liver. If shear waves are explained using an earthquake as an example, the longitudinally vibrating P waves propagate more quickly and the transversely vibrating S waves propagate more slowly. In the human body as well, the transversely vibrating shear waves propagate slowly, at a velocity of 1 m/s to 10 m/s. In addition, the propagation velocity differs significantly depending on the tissue stiffness. These characteristics make it possible to detect shear waves using a diagnostic ultrasound system. The pressure that is needed to induce 100% strain in the target tissue is represented by the modulus of elasticity (kpa), and the velocity of shear wave a b a: A part of the tissue is deformed by a push pulse. b: The shear velocity is higher in a stiff obstacle such as a tumor. Figure 2: Changes in shear velocity in SWE. a b c Figure 3: Tracing of shear waves in SWE. The depth direction represents time. A tracing of shear wave propagation is shown. The blue lines indicate that the shear wave has passed. 3 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

propagation that is obtained by poking one point and then observing the vibration at another point is referred to as the shear velocity (Fig. 1). In the new Shear Wave Elastography (SWE) method that has been developed by Toshiba, a part of the tissue is deformed by a push pulse, the velocity of the shear waves propagating within the tissue is detected, and the stiffness of the tissue is assessed based on the detected shear velocity (Fig. 2a). If an obstacle such as a tumor is present in the tissue, the shear velocity in that area differs from the shear velocity in the surrounding areas. If the obstacle is stiffer than the surrounding tissues, the shear waves propagate faster (Fig. 2b), and if the obstacle is softer, the shear waves propagate slower. The propagating shear waves are detected by transmitting search pulses. When the time at which the shear waves have reached each distance is plotted with the horizontal axis representing the propagation distance and the vertical axis representing time, a tracing showing the propagation of shear waves within the liver is obtained (Fig. 3). In uniform tissue, the shear velocity does not change and the tracing is a straight line. But if the shear velocity changes, the slope of the tracing also changes. For example, if a stiff tumor is present in the liver, the area in which the shear velocity is higher (i.e., the area that is determined to be stiffer) is displayed in red on the screen. One of the major features of SWE is that it is possible to select continuous scan, in which the frame rate can be selected in three steps, or one-shot scan, in which image quality is given higher priority. Continuous scan is advantageous for evaluating areas that are likely to be affected by cardiac motion, but at our institution, we select one-shot scan in order to obtain higher image quality. Another major feature of SWE is that images can be viewed using three different display modes after freezing: Speed (shear velocity) mode (m/s), Elasticity mode (kpa), and Propagation (arrival time contour) mode (Fig. 4). USEFULNESS OF SHEAR WAVE ARRIVAL TIME CONTOURS In conventional elastography methods, there is no means for determining whether or not the shear waves propagate properly based on the displayed color images. With SWE, it is possible to observe whether the shear waves propagate properly through the tissue in a single still image displayed in Propagation (arrival time contour) mode (Fig. 5). The intervals between the displayed contour lines are wider in stiff tissues and narrower in soft tissues. In diffuse diseases with no obstacles, the shear velocity does not change and the intervals between the contour lines should be constant. In areas where the contour lines are parallel, the shear waves propagate properly and the reliability of the obtained data is high. In areas where the contour lines are distorted and not parallel to one another, the Switching among three display modes is possible after freezing. Shear velocity : Speed mode [m/s] Modulus of elasticity : Elasticity mode [kpa] Arrival time contour : Propagation mode Display in Propagation mode Background and purpose To determine whether the shear waves propagate properly. To measure the stiffness in areas where the shear waves propagate properly. Propagation display shows whether the shear waves are generated and propagate as expected in a single still image. speed [m/s] elasticity [kpa] propagation Stiff target Soft target Figure 4: Features of SWE. Switching among three display modes is possible after freezing. Figure 5: Arrival time contours in SWE. Display in Propagation mode. 4 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

reliability of the obtained data is low. In other words, the reliability of the data can be verified by observing the contour lines (Fig. 6). SWE is designed so that no color is displayed in areas where data reliability is low due to the influence of blood vessels in Speed mode as well, but shear wave propagation can be observed more clearly in contour display. In addition, contour display makes it possible to verify the data reliability in deeper regions where shear waves are difficult to generate. As discussed above, arrival time contour display is very useful for verifying the reliability of the data and for selecting suitable areas for shear velocity measurement. For example, even in a patient with severe fatty liver and a skinfold thickness of 3 cm, it was possible to obtain data with verified reliability by determining the area in which the shear waves propagate uniformly using contour display and measuring the shear velocity within this area (Fig. 7). CLINICAL DATA FOR SWE Clinical data obtained at our institution in the period from January 31 to April 3, 2014, is shown. The targets were 236 cases in which liver stiffness was measured using two or more ultrasound system models and 64 cases in which liver biopsy was performed. Case 1 was diagnosed as F1 and A1 (chronic hepatitis) based on the liver biopsy findings. It can be confirmed that in the areas displayed in clear blue in Speed mode, the shear waves propagate uniformly in Propagation mode (Fig. 8). The blood vessels are displayed in black. Propagation display Clinical experience with arrival time contour display High reliability Distorted and not parallel to one another Low reliability Lines nearly straight and parallel to one another High reliability Example of a patient who was difficult to examine (thick abdominal wall and fatty liver) A thick abdominal wall and fatty liver are both factors that interfere with focusing of the push pulse. As a result, it is difficult to generate shear waves. Such patients are difficult to examine using SWE. Even in this case, parallel contour lines are observed in the upper-right part of the image in Propagation display mode. The measurement data can be verified to be reliable in such areas. Figure 6: Reliability of propagation display based on the contour lines. Figure 7: Verifying data reliability based on arrival time contour display. Mean: 1.51 m/s Mean: 2.30 m/s Figure 8: Case 1: F1, A1 (chronic hepatitis). Figure 9: Case 2: F3, A1. 5 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

Case 2 was diagnosed as F3 and A1 based on the liver biopsy findings. The color tone of the image is more yellowish than in case 1 (Fig. 9). The intervals between the contour lines are slightly wider, and the shear velocity measurement is 2.3 m/s. Case 3 was diagnosed as liver cirrhosis (F4). The image appears significantly more yellowish than in case 2 (Fig. 10). Red areas are also observed, clearly indicating stiff tissues. The intervals between the contour lines are even wider than in case 2. The platelet count was 7.8 10 4 µl-1 and the serum albumin level was 3.5 g/dl. The shear velocity measurement is 3.32 m/s. At our institution, we use diagnostic ultrasound systems manufactured by three different companies in addition to the Toshiba Aplio. The correlation coefficients between the measurement values obtained using Aplio and those obtained using the systems from each of the other companies were 0.884, 0.852, and 0.938, suggesting that the reliability of the measurement values obtained using SWE developed by Toshiba is comparable to that of conventional products. In the 64 cases in which liver biopsy was performed, the correlation coefficients for the Aplio compared with the systems 72-year-old man, CH (C), SI: 26.9, esophageal varices F1, gastric varices F1 5 4.5 0.883 0.046 0.001 B-mode CT Blood chemistry data TSW Toshiba VTQ Siemens SSI SWE Echosens TE Blood chemistry data TSW SWE VTQ SWE FibroScan TE AST 42 U/l 3.38 2.55 3.53 3.53 ALT 34 U/l 3.05 3.43 3.43 PLT 7.8 10 4 μl 3.47 2.13 3.20 3.20 T-bil 0.7 mg/dl 3.23 2.59 3.20 3.20 ALB 3.5 g/dl 3.47 2.50 3.08 3.08 PT 78.8 % 3.32 3.04 3.04 Hyaluronic acid ng/dl 3.33 3.33 3.43 3.43 3.38 3.38 3.04 3.04 Mean 3.32 2.38 3.27 3.27 Figure 10: Case 3: F4 (liver cirrhosis) TOSHIBA_A500 4 3.5 3 2.5 2 1.5 1 F1 F2 F3 F4 N 21 13 16 14 Mean 1.646 1.762 2.213 2.862 Figure 11: Comparison with liver biopsy findings. 64-year-old woman, CH (C), F1, A1, SI: 24.8, esophageal varices F1, gastric varices F1 64-year-old woman, CH CH (C), CH (C), F1, (C), F1, A1, F1, A1, SI: A1, SI: 24.8, SI: 24.8, 24.8, esophageal varices F1, F1, F1, gastric varices F1 F1 F1 1.00 Cutoff value (F1-F3 Vs F4) 0.80 Blood chemistry data Toshiba Siemens SSI Echosens Blood chemistry data data data TSW SWE TSW TSW VTQ VTQ VTQ SWE SWE SWE TE TEFibroScan AST AST AST 124 124 U/l 124 U/l U/l 2.24 2.24 2.24 1.88 1.88 1.88 2.5 2.5 2.52.18 2.18 2.18 ALT ALT ALT 106 106 U/l 106 U/l U/l 2.19 2.19 2.19 1.93 1.93 1.93 2.3 2.3 2.3 PLT PLT PLT 7.0 7.0 7.0 10 10 4 μl 10 4 μl 4 μl 2.21 2.21 2.21 1.77 1.77 1.77 2.5 2.5 2.52.07 2.07 2.07 Reason for for for mismatch T-bil T-bil T-bil 0.9 0.9 0.9 mg/dl 2.22 2.22 2.22 1.80 1.80 1.80 2.3 2.3 2.32.03 2.03 2.03 Clinically LC LC LC ALB ALB ALB 3.4 3.4 g/dl 3.4 g/dl g/dl 2.23 2.23 2.23 1.86 1.86 1.86 2.5 2.5 2.52.00 2.00 2.00 2.26 2.26 2.26 2.3 2.3 2.32.16 2.16 2.16 PT PT PT 89.0 89.0 89.0 % % % 2.24 2.24 2.24 Hyaluronic acid acid acid 325 325 325 ng/dl 1.98 1.98 1.98 2.09 2.09 2.09 Mean 2.23 2.23 2.23 1.85 1.85 1.85 2.40 2.40 2.40 2.11 2.11 2.11 Measurement value value 0.60 0.40 0.20 0.00 0.00 Cutoff value = 2.23 0.20 0.40 0.60 0.80 1.00 Figure 12. Case 4: F1, clinically diagnosed as liver cirrhosis. Figure 13: Cutoff value for the diagnosis of liver cirrhosis using SWE. (2.23 m/s) F1-F3 Vs F4 = 'F4' is assumed to be positive. Area under the ROC curve = 0.90143 6 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

from each of other companies were obtained. The results were 0.927, 0.916, and 0.959, indicating statistically significant high correlations. When the relationships between the liver biopsy findings and shear velocity values obtained using Aplio were analyzed, the box plots showed that the diagnostic capabilities for F4 were high, although there were several extreme outliers (Fig. 11). The mean shear velocity was 1.646 m/s in cases diagnosed as F1, 1.762 m/s in cases diagnosed as F2, 2.213 m/s in cases diagnosed as F3, and 2.862 m/s in cases diagnosed as F4, indicating that the measurement values increased in parallel with the degree of fibrosis. With regard to the cases in which significant mismatch was observed between the liver biopsy findings and the measurement values, these cases had, for example, been diagnosed as F1 based on the liver biopsy findings but clinically found to have liver cirrhosis complicated by gastric and esophageal varices (Fig. 12). In case 4, high measurement values were obtained by systems other than Aplio. The tissue specimens obtained by liver biopsy contained wide areas of fibrosis, but this case was diagnosed as F1 by the pathologist. Since the image displayed in Speed mode of SWE is yellowish and the intervals between the contour lines are wide, it appears possible to diagnose this case as liver cirrhosis. Based on the results obtained at our institution, the cutoff value for cirrhosis in SWE was calculated to be 2.23 m/s, although the number of cases was small (Fig. 13). Cases in which the shear velocity is 2.23 m/s or higher can be diagnosed as having liver cirrhosis. The area under the ROC curve was 0.9, which is excellent. CONCLUSION The liver stiffness measurement function of the new elastography method known as SWE developed by Toshiba Medical Systems Corporation was found to have diagnostic capabilities for fibrosis comparable to the analogous functions of systems manufactured by other companies. It was confirmed that the shear velocity measured by SWE tends to increase in parallel with the degree of fibrosis. Arrival time contour display, which is a major feature of SWE, makes it possible to observe whether the shear waves propagate properly, allowing the reliability of the obtained data to be verified. With systems other than Aplio, when images are displayed with mottled colors in elastography images, the reliability of the data may be questionable and it is often necessary to repeat the examination several times. With Aplio, it is expected that reliable data can be obtained in a single examination by observing the shear wave arrival time contours. 7 Medical Review: Approaches to the Diagnosis of Liver Fibrosis

Toshiba gives you a voice. What s yours? toshibamedicalsystems.com Toshiba Medical Systems Corporation 2014. All rights reserved. Design and specifications are subject to change without notice. Printed in Japan TUS-A500 MOIUS0074EA 2014-09 TME/D