Angle Stable Distal Radial Plate System WINSTA-R

Similar documents
Dieter Marquardt Medizintechnik GmbH 10 Hand System

WINSTA-R. Distal Radius System

WINSTA-C. Clavicle Plating System

Angle-stable Foot plate system Pedus-O and Pedus-U

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

PipTree. Arthrodesis of the PIP joint

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Distal Ulnar Locking Plate

Aesculap Orthopaedics Targon DR

Instrument and Implant for wrist fracture

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

Distal Radius Plate 2.4/2.7 dorsal and volar

PEDUS-L. Locking Plantar Lapidus Plate

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Complex process High costs

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

NCB Distal Femur System. Surgical Technique

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Humerus Block. Discontinued December 2016 DSEM/TRM/0115/0296(1) Surgical Technique. This publication is not intended for distribution in the USA.

Wrist Fixation System

2.4 mm LCP Radial Head Plates. Part of the Synthes LCP Distal Radius Plate System.

LCP Distal Humerus Plates

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

LCP Distal Tibia Plate

Introduction Basics MIS Screw 2 System Characteristics 2 Indication 2

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

NCB Proximal Humerus Plating System

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

PROXIMAL TIBIAL PLATE

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

VariAx TM Distal Radius Locking Plate System

VariAx Distal Radius Locking Plate System

Open reduction; plate fixation 1 Principles

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Conventus CAGE PH Surgical Techniques

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

3.5 mm LCP Distal Humerus Plates

Acu-Loc Wrist Plating System. Surgical Technique

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

2.4 mm Variable Angle LCP Dorsal Distal Radius Plate

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Aesculap Targon FN. Head Preserving Solution for Medial Femoral Neck Fractures. Aesculap Orthopaedics

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

Olecranon Osteotomy Nail. For simple fractures and osteotomies of the olecranon.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

2.4 mm LCP Distal Radius System

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

NCB Proximal Humerus System. Surgical Technique

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

2.4 mm Variable Angle LCP Volar Rim Distal Radius Plates

3.5 mm LCP Olecranon Plates

Pre-Operative Planning. Positioning of the Patient

Surgical Technique. Elbow Plating System

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

VariAx. Hand & Wrist. Distal Radius Locking Plate System

Elbow Plating System Surgical Technique

3.5 mm LCP Extra-articular Distal Humerus Plate

Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.

Extron External Fixator

Surgical Technique. Olecranon Locking Plate

Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

3.5 mm LCP Hook Plate

Clavicle Hook Locking Plate

Ixos. Radius Plating System Simply clever!

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

Olecranon Locking Plate II

Surgical Technique. Proximal Humerus Locking Plate

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

AcUMEDr. FoREARM ROD SYSTEM

Femur Condylar Plate System Procedural Steps.

Technique Guide. Small Fragment Locking Compression Plate (LCP) System. Stainless steel and titanium.

LCP Wrist Fusion Set. Anatomic plates for total wrist fusion.

Surgical Technique. Targeter Systems Overview

Surgical Technique. Distal Humerus Locking Plate

MetaCun DuoMetaCun. Midfoot Fusion Locking Plate System. Surgical Technique and Ordering Information

3.5 mm LCP Clavicle Hook Plates

Biomet Large Cannulated Screw System

Elbow Plating System

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

The Locking Calcaneal Plate Instrument and Implant Sets

SWEMAC CHS. Compression Hip Screw System

Transcription:

Angle Stable Distal Radial Plate System WINSTA-R Priv.-Doz.Dr.med. Martin Walz Dr. med. Felix Menzinger Prof.Dr.med. Jürgen Rudigier www.marquardt-medizintechnik.de

General The problem posed by metaphyseal and intra-articular fractures lies in the fact that even though implants can be well-anchored in the distal section of the shaft, fixation stability is however limited in the spongiose bones of the fragment close to the joint. Multifragmentary, intra-articular fractures as well as senile osteoporosis exacerbate this problem. In relation to the long proximal shaft section, the lever arm of the short distal joint fragment mechanically unfavourable during functional treatment places high demands on the stability of the implant itself as well as on its fixation in the distal fragment. In contrast to conventional implants, angle stable ones enable early functional treatment (especially desirable in the case of fractures close to joints), which is of great importance for the rapid restoration of a joint's functional integrity. Adaptation of the plate form and of the direction of the distal angle stable plate screws or pins to the physiological articular surface axes and curvatures facilitates correct reposition as well as the ideal repositioning of the implant components, thus increasing postoperative fracture stability. Product Characteristics High stability in the case of small implant dimensions. Anatomically correct form with volar bending to reconstruct the "palmar tilt", and secure support of the volar contour of the distal radius. The four distal plate holes are adjusted to the radioulnar curvature of the articular surface, and enable secure fixation of the distal radius even in the case of intra-articular fractures via subchondral positioning of the stabilization screws and pins. The given direction of the four angle stable screws or pins at the distal plate end corresponds to the physiological dorsovolar inclination of the articular surface, and enables the screws or pins to be placed in the ulnar fragment as well as in the styloid process of the radius. For fixation in the distal fragment, either self-cutting angle stable Ø 3.0 mm stabilization screws or angle stable Ø 2.0 mm stabilization pins are available. For fixation of the plate, self-cutting Ø 2.7mm corticalis screws are available. In the case of osteoporotic bones, angle stable Ø 3.0 stabilization screws can be used as an alternative. Precision drilling and length measurement for angle stable screws/pins via screw-in drill sleeve. For all screws and pins, only a Ø 2.0 mm drill is required. A cross-oval plate-hole enables reposition of intra-articular fragments as well as possible defect filling with spongiosa or bone substitute after plate fixation. The clearly laid-out instrumentarium facilitates handling. Various different plate lengths also suit the requirements of multiple metaphyseal fractures. Special surface treatment of plates and angle stable screws and pins byanodisation typeii(dotize ) Properties of processed products: - reduced tendency of cold welding of Titanium implants by screw in the angle stable pins and screws. - hardened Titanium surface. - increased fatigue resistance of implants. - significant reduction of AL and V release. 0 02 Reconstruction of the palmar tilt Anatomical radioulnar curvature Page

Indications Extra-articular fractures of AO-Type 23-A2 and A3 Partial intra-articular fractures of AO-Type 23-B and B3 Total intra-articular fractures of AO-Type 23-C to C3 03 Radiological Procedure, Case Study 0 AO-TYP 23-A3 Radiological Procedure, Case Study 2 05 AO-TYP 23-C Radiological Procedure, Case Study 3 AO-TYP 23-C3 Page 2

Operative Technique Two different techniques of volar bone-plate osteosynthesis can be applied: Possibility I: Primary fixation of the plate on the radius shaft. Reposition of the joint fragment on the distal plate section. 06 Possibility II: Primary fixation of the plate on the joint fragment. Reposition via fixation of plate onto radius shaft. 07 Possibility I Possibility II Access / Reposition of Fracture After partial deprivation of blood supply to the upper arm, a straight, volar skin incision of 5 to 0 cm is made parallel to the flexor carpi radialis as far as the antebrachial fascia. The ensuing procedure can either be radial, along the flexor carpi radialis, or medial. Radially, the A. radialis must be protected, and medially the N. medianus. Detach the M. pronator quadratus on the radial side from the radius shaft. Note that the distal fragment should only be displayed in so far as it is necessary for attaching the plate. If the joint fragment is multifragmentary, the fragments should be left together to facilitate ligamentotaxis. Then, reposition of the fracture, whereby the accident mechanism has to be repeated one more time. In the case of an extension fracture this results in extension at first, then in traction with transition to flexion; in the case of a flexion fracture, initial flexion is followed by traction with transition to extension. An image intensifier check of the reposition then results in two planes. Positioning and Fixation of the Plate on the Radius Shaft 08 After allocation of the correct plate length and the respective plate side, the plate is placed centrally onto the radius shaft, with image intensifier check. Make sure here that the longitudinal axis of the radius shaft and the plate match each other. Now position the plate, with image intensifier check, in the proximal-distal direction under preliminary fracture reposition via extension and volar flexion of the wrist, in order to estimate the original length of the radius. Here, the distal plate-end should be placed only a few millimetres proximally to the volar radial labrum, in order to achieve optimal support of the articular surfaces via subchondral screw positioning. Page 3

A Ø 2.7 mm corticalis screw is now placed into the oblong hole of the plate shaft. This results in the following procedure: Central placement of the double drill bush (REF: 02.20060.027) in the oblong hole of the plate shaft. Using the Ø 2.0 mm twist drill (REF: 0.2000.020), drill the core hole through the double drill bush (REF: 02.20060.027) Determine screw length by means of depth gauge (03.2000.060) Screw in the Ø 2.7 mm corticalis screw with the 2.5 mm hexagonal screwdriver. (REF: 03.2000.025) 09 Note here that the screw must not yet be tightened completely, so that the plate position can still be adjusted distally and proximally. Check again, and correct the plate position if necessary, with image intensifier check. Once the plate is correctly positioned, tighten the screw, thus fixing the plate to the shaft of the radius. If definitive fixation of the plate to the radius shaft is now required, a screw can also be applied through the other screw-holes in the shaft area. Use of the Distal Plate-Holes By means of pulling at the fingers and volar flexion of the wrist, the fracture is reduced until the joint fragment lies on the distal plate-end. In the case of a dorsal fracture zone it can be helpful to dorsally exert pressure with a finger on this zone while using the distal plate-holes, in order to secure the retention of these fragments in anatomical position by means of the applied stabilization screws or pins. It is recommended to begin by using the marginal ulnar platehole. This fixes the ulnar bone fragment and guarantees the congruence of the distal radioulnar joint. This results in the following procedure: Screw the drill sleeve (REF: 0.20060.06) into the marginal ulnar plate-hole. Using a Ø 2.0 mm twist drill (REF: 0.2000.020), drill the core hole through the drill sleeve (REF: 0.20060.06), during optimal reposition. Determine screw length by means of depth gauge (REF:0.2000.050) through the screwed-on drill sleeve (REF: 0.20060.06). Screw in the angle stable stabilization screw or pin with the 2.5 mm hexagonal screwdriver (REF: 03.2000.025) during optimal reposition. 0 With an image intensifier check, check the implant location in two planes as well as the reposition result. If necessary, and if no definite fixation of the plate on the radius shaft has been undertaken, correction of plate location and reposition can be carried out by loosening the screw in the oblong plate-hole. Page

The recommended next step is to make use of the terminal radial plate-hole. This generally means that the distal joint fragment is adequately fixed, so that the fingers no longer need to be pulled. One now has the choice of using either stabilization screws or pins in the two central plate-holes. As a result of this depending on the type of fracture a further stabilization of intermediate fragments can be achieved, if necessary by repositioning them separately, via the crossoval plate-hole. Defect filling can also be carried out through this if necessary. Follow with an image intensifier check in two planes. The remaining holes in the shaft region now have to be filled if this has not occurred already with Ø 2.7 mm corticalis screws. However there is also a possibility, especially in the case of bad bones, to use angle stable corticalis screws in the remaining holes. This is left to the surgeon to decide, on the basis of the respective bone quality. 2 Follow with an image intensifier check in two planes, plus a function check with regard to free mesial rotation of the forearm, upward turning of the palm, extension and flexion. Now bathe the operating site thoroughly, if necessary adding wound drainage proximally to the skin incision, and follow with subcutaneous and cutaneous sutures. Any required immobilization in plaster needs to be decided in individual cases. As a rule this is unnecessary, both because of the degree of stability achieved and because of any intended postoperative functional therapy. During the first few days, an elastic pressure bandage above cotton-wool padding is frequently all the protection that is required. 3 Additional Information In the case of a very broad distal radius, use the form of the intra-articular fracture components to ascertain whether the plate position should be more radial or more ulnar, in order to guarantee retention either of an ulnar bone fragment or a fractured styloid process of the radius. Here the correspondence between the longitudinal axes of the radius shaft and the plate shaft should be retained, in order not to change the screw direction adapted to the anatomical form especially where the marginal radial and ulnar plate-holes are involved. In the case of a very narrow distal radius, by screwing in each drill sleeve onto the terminal radial and ulnar plate-hole and using image intensification with orthograde focus, check to see whether the relevant screw or stabilization pin is lying in a secure intraossal position. Should this not be the case, one of the marginal plate-holes can remain unused. Page 5

Angle stable supporting pins Ø 2.0 mm 0.03520.06 0.03520.08 0.03520.020 0.03520.022 0.03520.02 0.03520.026 0.03520.028 0.03520.030 Screw length 6 mm 8 mm 20 mm 22 mm 2 mm 26 mm 28 mm 30 mm Corticalis screws Ø 2.7 mm, self-cutting 03.03527.00 03.03527.02 03.03527.0 03.03527.06 03.03527.08 03.03527.020 03.03527.022 03.03527.02 Screw length 0 mm 2 mm mm 6 mm 8 mm 20 mm 22 mm 2 mm Angle stable cortical screws Ø 3.0mm, self-cutting 0.03530.02 0.03530.0 0.03530.06 0.03530.08 0.03530.020 0.03530.022 0.03530.02 0.03530.026 Screw length 2 mm mm 6 mm 8 mm 20 mm 22 mm 2 mm 26 mm 0.03530.028 28 mm 0.03530.030 30 mm Angle stable radial plates right / left No. of holes in head (without oblong hole) No. of holes in shaft (without oblong hole) 0.95.02 3 2 Right 0.95.202 3 2 Left 0.95.0 0.95.20 0.95.302 3 3 2 Right Left Right 0.95.02 2 Left 0.95.30 0.95.0 Right Left 0.95.308 8 Right 0.95.08 8 Left 0.95.702 6 2 Left 0.95.802 6 2 Right 0.95.70 6 Left 0.95.80 6 Right Page 6

Angle Stable Distal Radial Plate System WINSTA-R GRAPHICS CASSETTE Item description Graphics cassette + implant rack empty Graphics cassette + implant rack with contents Implant rack empty Container, only, empty Lid for container 0.2230.000 0.2230.005 0.2230.002 0.2230.00 0.2230.003 INSTRUMENTS IN SET 2 02.2020.05 Quantity 0.2000.020 03.2000.025 03.2000.026 2.20060.07 0.20060.06 0.2000.050 03.2000.060 02.2020.05 03.2000.060 0.2000.050 0.20060.06 2.20060.07 03.2000.026 03.2000.025 0.2000.020 Item description Twist drill Ø 2.0 mm, 2 mm Screwdriver 2.5 mm hexagonal Screw holding sleeve Double drill sleeve.7 mm / 2.0 mm Drill sleeve Depth gauge 50 mm Depth gauge 60 mm Screw-retaining forceps Dieter Marquardt Medizintechnik GmbH Robert-Bosch-Str. 7859 Spaichingen Telephone: +9 (0) 72 / 9580 Telefax: +9 (0) 72 / 50 info@marquardt-medizintechnik.de www.marquardt-medizintechnik.de Date: 08.09.2008 Rev. C