SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Similar documents
SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

Variable Frequency Drives

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

Cerus P-Series General Specifications Section 15172

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

Trane TR150 Variable Frequency Drive Guide Specification Section GENERAL II. PRODUCTS

RDP/DDP REDUNDANT/DUPLEX DRIVE PACKAGE

SPECIFICATION GUIDE. Phoenix EX AC Drive Closed Loop AC Vector Control 3 HP to 3500 HP 200 to 600 VAC Input

MS MS Manual Motor Starter. Generell informasjon. Ordering. Popular Downloads. Dimensions. Technical MS Extended Product Type

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

System Multiplexer / Permissive Module

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

VLT HVAC Drive. Variable Frequency Drive w/ Electro-Mechanical Bypass Guide Specification. Section 15172

VLT HVAC Drive. Variable Frequency Drive w/ Electronically Controlled Bypass Guide Specification. Section 15172

DIVISION 15 - MECHANICAL. Section Variable Frequency Drives. Introduction

McQuay. Enclosed Variable Frequency Drive MED. Replacement Parts List No New 09/2008

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

user manual VFD 4X control panel INSTALLATION - OPERATION

Variable Frequency Drives Lessons Learned

Geräteblatt Pallazza III PGI

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Installation Instructions

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

E-Link Gateway Installation Instructions

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

General Information. Ordering. Popular Downloads. Dimensions. Technical

Technical support: +49 (0)7223 /

HPS Centurion R Iron Core Reactors

RiGO801 Laboratory Requirements

Armstrong IVS 102 Drive Specification

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC

Installation Instructions

Fuse Combination Switches & Switch Disconnectors Dimensions

MicroSwitcher TMS Series 6, 10, 15, 25 Watt

Dr FuelCell Load Measurement Box

RLS /M MX SERIES

Frequently Asked Questions

Mounting and Wiring VMA1200 Series Controllers

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

Bosch BOVA Split System Heat Pump

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution

ULTR A SERIES G7-S75

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

Product Guide. NH Fuse System

Side Channel R ing Blower

FITNESS #1 HOME

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

Technical Tip: How to Connect and Troubleshoot Transducer Feedback. Product(s): iqpump1000 and iqpump Micro Drives

XRS-5/XRS-5CTRANSDUCER

E2 Programming Start Up Guide for the M400 drive.

Input Load (ma) Typ.

Meter Equipment Group

GRUNDFOS DATA BOOKLET. BM, BMhp. Booster Modules 50/60 Hz

SEW-EURODRIVE Service Series Changing Stator Voltage

Motorised Treadmill Model No: JI1625

Lexium 05 motion control

Variable Speed Drive Specification

Sep2018 Rev B1

RLS /M MX SERIES

SlideDriver 50VF. Modbus Controlled VFD Replacement Kit (MX4210, MX4211) REQUIRED TOOLS PARTS WORK SAFELY!

RLS /E MX SERIES

MOTOR STARTING AUTOTRANSFORMERS

The Do s and Don ts of Pressure Transducers

Instruction Manual January 2001 PS 10/15 F SERIESTRANSDUCER

ATyS D10 & D20. Notice d utilisation - Operating instructions AFFICHEURS DÉPORTÉS - REMOTE INTERFACES MAKE YOUR BUSINESS SAFE

AJAX TABLE OF CONTENTS. R/KBM and R/KBC Series. Rotary Electric Vibrators

PROBE CONDITIONING SYSTEM- P/N FOR BATCH FURNACES

ULTR A SERIES G7-S23

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

Fittings & Accessories

ULTR A SERIES G7-S13

ALERT SERVICE BULLETIN Alert Service Bulletin No. 072

BH Fitness T4 / T6 SPORT Treadmill Owner s Manual

Lexium 05 Servo Drives. Motion control The high concentrate solution for your machines

Quick Selections. How to Use Service Factor. Worm Gear Reducers. Single Reduction

Low Row. User manual E S S E N T I A L S T R E N G T H

Signet 2850 Conductivity/Resistivity Sensor Electronics

Portable Grain Drying

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

ALERT SERVICE BULLETIN Alert Service Bulletin No. 072 Rev. A

130-TYPE TELETYPEWRITER SUBSCRIBER SET DESCRIPTION. c. Line Relay Operation 3 3. REFERENCES. 4. BELL SYSTEM PRACTICES Plant Series

CAUTION: Health related injuries may result from incorrect or excessive use of exercise equipment.

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

OWNER S MANUAL and INSTALLATION INSTRUCTIONS

Ultrasonic Transducers

VIAVI IFR6000 DME Mode Signal Generator Reply Pulse Width Output Frequency Echo Reply Output Level Reply Pulse Rise and Fall Times (all pulses)

Electric Desk Adjustable

TWO STAGE DUAL FUEL BURNERS

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

Transcription:

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency Drives (VFDs). Product Numbers VBA SED2 VFD Conventional Bypass Options Contents The SED2 C-Bypass Option consists of a SED2 VFD and a bypass enclosure which includes Step-down power transformer Contactors: Bypass, Output, Input (optional) Overload (current) relay Reactor (optional) Disconnect switch (or optional circuit breaker) Fuses (optional) Warning/Caution Notations WARNING: CAUTION: Personal injury/loss of life may occur if you do not follow the procedures as specified. Equipment damage, or loss of data may occur if you do not follow the procedures as specified. Expected Installation Time 45 minutes Prerequisites Mounting clearance: Leave six-inches (154 mm) of space at top and bottom for equipment access. If fitted with a protective shield, allow 12 inches (305 mm) of space between the sides of each VFD to allow for sufficient heat dissipation. Inverter duty motors are recommended. Install motors within their guidelines. Use dvd/dt filters, output reactors, or other load conditioners as applicable as applicable or as specified by the motor manufacturer. If a disconnect is mounted on the load side of your drive, it is desirable to wire an auxiliary contact to the drive that will disable drive operation when the disconnect opens. (The wiring for this contact must not be run in the same conduit as the drive output wires.) CAUTION: Installation If installing a SED2 VFD after prolonged storage, see the SED2 VFD Startup, Operation and Maintenance Manual for Mechanical Installation procedures. (Document Number 125-3201). CAUTION: Height above sea level: If installing a SED2 VFD at an altitude higher than 3,280 ft (1000 m), de-rating is required. CAUTION: : Never run control or drive input wires in the same conduit as the drive output wires Cable Length Cable length is given to ensure performance of only the drive, not the suitability of the motor when connected to a drive at this distance. Maximum cable length is 164 ft (50 m). A load reactor is recommended for cable distances greater than 164 ft (50 m). Keep the distance from the drive to the motor as short as possible to maximize motor life. Item Number 129-374, Rev. DA http://www.siemens.com/hvp/drives Page 1 of 11

Dimensions Figure 1. C-Bypass Mounting and Overall Dimensions in Inches (Centimeters). Table 1. C-Bypass Approximate Weights. Frame Size Wt. lb (kg) A 45 (20) B 55 (25) C 75 (34) D 150 (68) E 180 (82) F 470 (213) NOTE: Exact weight will be affected by actual horsepower/voltage and selected power options. Page 2 of 11 http://www.siemens.com/hvp/drives Siemens Industry, Inc.

Dimensions, Continued Figure 2. Frame Sizes A through C Conduit Location. Viewed from Bottom; Dimensions in Inches (Centimeters). Figure 3. Frame Sizes D and E Conduit Locations. Viewed from Bottom; Dimensions in Inches (Centimeters). Figure 4. Frame Size F Conduit Locations. Viewed from Top; Dimensions in Inches (Centimeters). Siemens Industry, Inc. http://www.siemens.com/hvp/drives Page 3 of 11

Power Wiring NOTES: (#3 Drive parameters removed) 1. Branch circuit protection to be provided by installer, per UL508A, if not provided with drive. 2. If needed, use SBT-specified input line reactors to ensure a good impedance match with your drive. 3. Control and communication wiring should be 300V UL minimum. 4. Communication wiring should be run with maximum separation possible from all other wiring. 5. Essential service mode operates the motor full speed (bypass) with no protection for the motor or system. 6. See Siemens Publication SED2 Conventional ByPass Options Operating Instructions (125-3215) for proper fuse and wire sizes. 7. See Siemens Publication SED2 Variable Frequency Drives Startup, Operation and Maintenance Manual (125-3201) for SED2 VFD input/output signal wiring details. Figure 5. C-Bypass Power Circuit. Page 4 of 11 http://www.siemens.com/hvp/drives Siemens Industry, Inc.

Power Wiring, Continued Figure 6. Routing of Power and Control Wiring for Frame Sizes A and B. Figure 7. Routing of Power and Control Wiring for Frame Sizes C, D, and E. Figure 8. Routing of Power and Control Wiring for Frame Size F. Siemens Industry, Inc. http://www.siemens.com/hvp/drives Page 5 of 11

Wiring Diagrams Figure 9. C-Bypass 120 Vac Control Logic Page 6 of 11 http://www.siemens.com/hvp/drives Siemens Industry, Inc.

Wiring Diagrams, Continued Figure 10. C-Bypass Terminations. Siemens Industry, Inc. http://www.siemens.com/hvp/drives Page 7 of 11

Part Number Bypass Frame Size Table 2. Sizes and Tightening Torques for E-Bypass with 208V Drive. HP kw Circuit Breaker Disconnect Switch VBE10.5---- A 0.5 0.37 2.3 Cu 32 (3.6) 18-10 VBE10.7---- A 0.7 0.55 3.0 Cu 32 (3.6) 18-10 VBE11.0---- A 1.0 0.75 3.9 Cu 32 (3.6) 18-10 VBE11.5---- B 1.5 1.1 5.5 Cu 32 (3.6) 18-10 VBE12.0---- B 2.0 1.5 7.4 Cu 32 (3.6) 18-10 VBE13.0---- B 3.0 2.2 10.4 Cu 32 (3.6) 18-10 VBE15.0---- C 5.0 4.0 16.7 Cu 32 (3.6) VBE17.5---- C 7.5 5.5 22.0 Cu VBE110.---- C 10 7.5 28 Cu VBE115.---- D 15 11.0 42 Cu VBE120.---- D 20 15.0 54 Cu VBE125.---- D 25 18.5 68 3-3/0-3 Cu 80 (9) VBE130.---- E 30 22.0 80 3-3/0-3 Cu 80 (9) VBE140.---- F 40 30.0 104 VBE150.---- F 50 37.0 130 VBE160.---- F 60 45.0 154 kcmil Cu kcmil Cu kcmil Cu (14-31.1) (14-31.1) (14-31.1) kcmil kcmil (13.5-31.1) (13.5-31.1) Overload Range, Max Backup Fuse, Ground Lug Torque, 1.8-2.5 10 14-2 2.2-3.2 12 14-2 2.8-4 16 14-2 4.5-6.3 25 14-2 5.5-8.0 30 14-2 7-10 40 14-2 (2-25) 14-20 80 14-2 (2-25) 20-25 100 14-2 22-32 125 14-2 40-50 200 14-2 45-63 250 14-2 57-75 300 14-2 70-90 350 14-2 * Size in AWG unless noted otherwise. Use Copper (Cu) wire that is rated 167 F (75 C) minimum, 600 Vac. Page 8 of 11 http://www.siemens.com/hvp/drives Siemens Industry, Inc.

Part Number Bypass Frame Size Table 3. Sizes and Tightening Torques for C-Bypass with 230V to 240V Drive. HP kw Circuit Breaker Disconnect Switch VBA20.5--- A 0.5 0.37 2.2 Cu 32 (3.6) 18-10 VBA20.7--- A 0.7 0.55 3.0 Cu 32 (3.6) 18-10 VBA21.0--- A 1.0 0.75 3.9 Cu 32 (3.6) 18-10 VBA21.5--- B 1.5 1.1 5.5 Cu 32 (3.6) 18-10 VBA22.0--- B 2.0 1.5 6.8 Cu 32 (3.6) 18-10 VBA23.0--- B 3.0 2.2 9.6 Cu 32 (3.6) 18-10 VBA25.0--- C 5.0 4.0 15.2 Cu 32 (3.6) VBA27.5--- C 7.5 5.5 22 Cu VBA210---- C 10 7.5 28 Cu VBA215---- D 15 11.0 42 Cu VBA220---- D 20 15.0 54 Cu VBA225---- D 25 18.5 68 3-3/0-3 Cu 80 (9) VBA230---- E 30 22.0 80 3-3/0-3 Cu 80 (9) VBA240---- F 40 30.0 104 kcmil Cu (14-31.1) VBA250---- F 50 37.0 130 kcmil Cu (14-31.1) kcmil (13.5-31.1) VBA260---- F 60 45.0 154 kcmil Cu (14-31.1) kcmil (13.5-31.1) (2-25) (2-25) Overload Range, * Size in AWG unless noted otherwise. Use Copper (Cu) wire that is rated 167 F (75 C) minimum, 600 Vac. Max Backup Fuse, Ground Lug 1.8-2.5 10 14-2 2.2-3.2 12 14-2 2.8-4 16 14-2 4.5-6.3 25 14-2 5.5-8.0 30 14-2 7-10 40 14-2 14-20 80 14-2 20-25 100 14-2 22-32 125 14-2 40-50 200 14-2 45-63 250 14-2 57-75 300 14-2 70-90 350 14-2 Siemens Industry, Inc. http://www.siemens.com/hvp/drives Page 9 of 11

Part Number Bypass Frame Size Table 4. Sizes and Tightening Torques for C-Bypass with 380V to 480V Drive. HP kw Circuit Breaker Disconnect Switch VBA30.5---- A 0.5 0.37 1.1 Cu 32 (3.6) 18-10 VBA30.7---- A 0.7 0.55 1.6 Cu 32 (3.6) 18-10 VBA31.0---- A 1.0 0.75 2.1 Cu 32 (3.6) 18-10 VBA31.5---- A 1.5 1.1 3.0 Cu 32 (3.6) 18-10 VBA32.0---- A 2.0 1.5 3.4 Cu 32 (3.6) 18-10 VBA33.0---- B 3.0 2.2 4.8 Cu 32 (3.6) 18-10 VBA35.0---- B 5.0 4.0 7.6 Cu 32 (3.6) 18-10 (.8-1.2) VBA37.5---- C 7.5 5.5 11 Cu 32 (3.6) 18-10 VBA310---- C 10 7.5 14 Cu 32 (3.6) 18-10 13 to17 (2-2.5) VBA315---- C 15 11.0 21 Cu (2-2.5) VBA320---- C 20 15.0 27 Cu VBA325---- D 25 18.5 34 Cu VBA330---- D 30 22.0 40 Cu VBA340---- D 40 30.0 52 Cu VBA350---- E 50 37.0 65 Cu VBA360---- E 60 45.0 77 3-3/0 Cu 80 (9) VBA375---- F 75 55.0 96 3-3/0 Cu 80 (9) VBA3100--- F 100 75.0 124 - kcmil Cu (14-31.1) kcmil (13.5-31.1) VBA3125--- F 125 90.0 156 - kcmil Cu (14-31.1) kcmil (13.5-31.1) VBA3125--- F 90.0 178 HA1 kcmil Cu (14-31.1) kcmil (13.5-31.1) Overload Range,.7-1.0 1.1-1.6 1.4-2.0 2.2-3.2 2.8-4 3.5-5 7-10 9-12 11-16 22-32 28-40 28-40 40-50 57-75 70-90 80-100 * Size in AWG unless noted otherwise. Use Copper (Cu) wire that is rated 167 F (75 C) minimum, 600 Vac. Max Backup Fuse, Ground Lug 4 14-2 6 14-2 8 14-2 12 14-2 16 14-2 20 14-2 40 14-2 45 14-2 60 14-2 80 14-2 125 14-2 150 14-2 150 14-2 200 14-2 300 14-2 350 14-2 400 14-2/0 50 (5.6) Page 10 of 11 http://www.siemens.com/hvp/drives Siemens Industry, Inc.

Part Number Bypass Frame Size Table 5. Sizes and Tightening Torques for C-Bypass with 500V to 600V Drive. HP kw Circuit Breaker Disconnect Switch Overload Range, Max Backup Fuse, Ground Lug VBA40.5---- C 0.5 0.37.9 Cu 32 (3.6) 18-10.7-1.0 4 14-2 VBA40.7---- C 0.7 0.55 1.3 Cu 32 (3.6) 18-10.9-1.25 5 14-2 VBA41.0---- C 1.0 0.75 1.4 Cu 32 (3.6) 18-10 1.1-1.6 6 14-2 VBA41.5---- C 1.5 1.1 2.1 Cu 32 (3.6) 18-10 1.8-2.5 10 14-2 VBA42.0---- C 2.0 1.5 2.7 Cu 32 (3.6) 18-10 2.2-3.2 12 14-2 VBA43.0---- C 3.0 2.2 3.9 Cu 32 (3.6) 18-10 2.8-4 16 14-2 VBA45.0---- C 5.0 4.0 6.1 Cu 32 (3.6) 18-10 4.5-6.3 25 14-2 VBA47.5---- C 7.5 5.5 9 Cu 32 (3.6) 18-10 7-10 40 14-2 VBA410.---- C 10 7.5 11 Cu 32 (3.6) 18-10 9-2 45 14-2 VBA415.---- C 15 11.0 17 Cu 32 (3.6) (2-2.5) 14-20 80 14-2 VBA420.---- C 20 15.0 22 Cu (2-2.5) 80 14-2 VBA425.---- C 25 18.5 27 Cu 22-32 125 14-2 VBA430.---- D 30 22.0 32 Cu 28-40 150 14-2 VBA440.---- D 40 30.0 41 Cu 36-45 175 14-2 VBA450.---- E 50 37.0 52 Cu 40-50 200 14-2 VBA460.---- E 60 45.0 62 Cu 45-63 250 14-2 VBA475.---- F 75 55.0 77 3-3/0 Cu 80 (9) 70-90 350 14-2/0 VBA4100--- F 100 75.0 99 3-3/0 Cu 80 (9) - 80-100 400 14-2/0 VBA4125--- F 125 90.0 125 - kcmil Cu (14-31.1) kcmil (14-31.1) 50-200 800 14-2/0 * Size in AWG unless noted otherwise. Use Copper (Cu) wire that is rated 167 F (75 C) minimum, 600 Vac 50 (5.6) 50 (5.6) 50 (5.6) Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Printed in the U.S.A. Page 11 of 11