CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Similar documents
Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Understanding Hip Implant Options

ACETABULAR CUP SURGICAL TECHNIQUE

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

Metasul LDH Large Diameter Head

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

A Proven Concept. Alloclassic Zweymüller Stem

Ceramic Femoral Heads and Acetabular Cup Liners

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Your BIOLOX Multimedia Tools. Anywhere. Anytime.

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

CERAMIC-ON-METAL. References: Cat No: version 2

Duraloc CONSTRAINED LINER

TriboFit Hip System. Issue 3 - August 2013 English

Presented by : Frank Filice (PT) London Health Sciences Centre

TOTAL HIP REPLACEMENT:

POLARCUP Dual Mobility System. General Safety Instructions. Instructions for Use. Duty to inform the patient. Implant passport

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Lubinus Classic Plus Hip Prosthesis System

Does the self-centering mechanism of bipolar hip endoprosthesis really work in vivo?

Shoulder Joint Replacement

CeramTec Medical Products. BIOLOX OPTION The First Choice for Hip Revision. With Case Reports

Product Information. *smith&nephew POLARCUP Dual Mobility System

Lubinus Classic Plus Hip Prosthesis System

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

Optimum implant geometry

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Progeny Hip Stem. Surgical Protocol and Product Specifications

The information contained in this document is intended for healthcare professionals only.

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

Bone Bangalore

Important Notice to Users in the United States: General Safety Instructions

Allofit /Allofit -S Alloclassic Acetabular Cup System

PediLoc Extension Osteotomy Plate (PLEO)

Trinity. Advanced Bearing Acetabular System Surgical technique

Robotic-Arm Assisted Surgery

Total Hip Replacement. Find out why the Anterior Approach may be right for you.

Optimum implant geometry

Hip Product Brochure

Peggers Super Summaries: THR and Revision Concepts

The information contained in this document is intended for healthcare professionals only.

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

GENESIS II/ LEGION Total Knee System

Total hip replacement

Bi-Polar 22.2mm & 28mm System - Operative technique

CONSENSUS ORTHOPEDICS INC.

Dual Mobility System Evaluation surgical technique

A Patient s Guide to Transient Synovitis of the Hip in Children

Dual Mobility System Surgical technique

Optimizing function Maximizing survivorship Accelerating recovery

Operating Instruction. Müller Hip Stem

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

Zimmer Maxera Cup. Surgical Technique. This device is not available for commercial distribution in the United States.

Manza Cup HA SURGICAL TECHNIQUE.

Optimum implant geometry

CeramTec Medical Products Neck Taper and Compatibility

DIRECT ANTERIOR APPROACH

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

Cemented femoral stem - type CSC

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

PMMA Spacer. X-ray Marker

BiMobile Dual Mobility System Cementless & Cemented. Surgical Technique

Total Hip Replacement Surgery

MULTIPOLAR BIPOLAR CUP. Surgical Technique

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

*smith&nephew POLARCUP Dual Mobility System. Product Information

Cementless femoral stem type SF

Important Notice to Users in the United States: General Safety Instructions

Furlong H-A.C. THR System

SL-PLUS MIA Stem, SL-PLUS MIA Stem Lateral, SL-PLUS/ INTEGRATION-PLUS MIA Stem with Ti/HA, SL-PLUS/INTEGRATION-PLUS MIA Stem Lateral with Ti/HA

Modular Unipolar Femoral Head Replacement. Surgical Technique

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Anterior Approach to Hip Replacement Surgery

MetaFix Cementless Total Hip Replacement Product overview

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

TOTAL KNEE ARTHROPLASTY (TKA)

PINNACLE REVISION CUP SYSTEM

I want that next-generation knee

BIOLOX delta Option Ceramic Femoral Head System. Product Features and Instructions for Use

All Ceramic Tripolar THA to Prevent Dislocations in Risky Patients

Total Hip Replacement

Part Two: Hip Resurfacing vs Conventional Total Hip Replacement

Hip Replacement - Anterior

The Leader in Orthopaedic Innovation

Effect of Femoral Head Size to Contact Stress at Pure Titanium Femoral Ball Head Outer Surface of Hip Joint Implant

Surgical technique MkII instrumentation

Osteoarthritis of the Hip

Scan Bi-Polar 22/28. Operative Technique

What Are Hip and Knee Replacement Implants Made Of?

Exeter. Technical Guide

Featuring. Technology. Product Rationale

Expand your Options. REX cement stop System

NCB Proximal Humerus Plating System

PediLoc Tibia Surgical Technique

Transcription:

CeramTec Medical Products BIOLOX DUO Ceramic Bipolar System Bone-sparing joint reconstruction with a maximum range of motion

2

BIOLOX DUO Ceramic Bipolar System Less is more BIOLOX DUO is an alternative to total hip replacement. The self-centering bipolar system leaves the acetabulum intact, thus allowing better proprioception. It provides a very large range of motion. The ceramic-ceramic wear couple drastically reduces polyethylene and metal wear debris. Consequently metal sensitivity and the risk of aseptic loosening due to polyethylene particles are also nearly prevented. The implant is particularly suitable for younger, more active patients and for patients with a sensitivity to metal. BIOLOX DUO combines the proven advantages of a modern bipolar prosthesis with the BIOLOX ceramic wear couple. 3

Alternative to Total Hip Replacement Compared with conventional hip replacements a bipolar system offers many important advantages: Conservation of the acetabulum Better proprioception Lower risk of dislocation Possibility of earlier mobilization Reduced surgical trauma Shorter operating time Easier surgical technique Lower risk of complications Faster rehabilitation possible Reduced cost as no acetabular shell is required Wider range of revision options 4

BIOLOX DUO permits a high degree of flexion with a lower risk of dislocation. 5

Sparing Bone, Protecting Cartilage Conservation of the acetabulum The BIOLOX DUO system is the treatment of choice for hip joint disease in which the acetabulum is intact and worth conserving. It can be used, for example, in the treatment of osteoarthritis, femoral head necrosis or femoral neck fracture. Better proprioception Minimization of surgical trauma to the joint capsule, the limbo and to the acetabulum helps to retain proprioception. This facilitates a rapid return to a physiological gait, along with the clear advantage of load bearing and muscle rehabilitation. Wider range of revision options Conservation of the acetabulum permits a wider range of revision options on the acetabular side and provides a good starting point for a revision operation, should one be needed. This increases the likelihood that the well fixed femoral stem can be left in place during a revision. 6

The BIOLOX DUO system is easy to assemble in situ. 7

The self-centering principle: The separation of the centers of rotation ensures that the bipolar shell does not tilt into an extreme varus position. Under load the shell gradually returns to its correct position. 8

Biomechanically Natural and Safe Stable with lower risk of dislocation The system has been designed to remain centered during normal walking and loading. The majority of the joint motion takes place in the inner bearing, between the ball head and the bipolar shell. Only at the extreme ranges of motion, for example in maximum flexion, will the bipolar shell also move. Under load the shell will gradually return to its neutral position. The extremely low friction of the articulating surface ensures that only a small amount of the motion takes place in the acetabulum, which is well-protected against erosion as a result. The large range of motion provided by the implant reduces the risk of dislocation. 9

Lasting Wear Resistance Wear-resistant and biocompatible BIOLOX ceramic is extremely resistant to abrasion and wear, which proves the material s suitability for use in joint replacement. Its advantages are in the bone and soft-tissue sparing design of the BIOLOX DUO system. In both the outer bearing against acetabular cartilage and the inner bearing against ceramic it creates articulations which provide long-term wear-resistance. Surface finish The outer surface of the bipolar shell articulates against the natural acetabulum; the inner surface articulates against the BIOLOX ball head. All of these ceramic surfaces are highly polished and possess extremely low surface roughness (Ra < 0.02 μm). Due to the smoothness of these surfaces and to the formation of an effective lubrication film, ceramic bearings are almost frictionless. 10

With conventional wear couples consisting of metal and polyethylene the release of metal ions or a material adverse reaction may occur. Ceramic-on-ceramic is extremely wear-resistant. Material adverse reactions are not known. Metal ion release is below the detection limit of analytical methods and is not clinically significant. Extremely smooth surface of a BIOLOX delta ball head. Source: CeramTec GmbH 11

Optimal Lubrication Excellent wettability Hydrogen bonds form between the ceramic surface and the synovial fluid. The excellent wettability of BIOLOX ceramic permits the formation of an effective lubrication film, which continuously maintains a low coefficient of friction. This property optimizes the sliding ability of the inner and outer bearings of the BIOLOX DUO system. Coupled with the self-centering design of the system, this ensures that only a small part of the joint motion is transferred to the acetabulum. Metal: 86 Ceramic: 45 The wetting angle for metal and polyethylene (left) is about twice as large as that for BIOLOX ceramic (right). The smaller the wetting angle, the better the wettability. Source: CeramTec GmbH Source: CeramTec GmbH 12

Well-Tolerated by the Human Body Excellent biological behavior In the long-term clinical application no adverse body reactions to ceramic particles are known. Ceramic is bioinert and biocompatible. Clinical results After more than 40 years of clinical use in total hip replacements a large number of long-term clinical reports are available for BIOLOX ceramic. With regards to the solution of the osteolysis problem, BIOLOX ceramic has prevailed as a proven alternative to metal and polyethylene wear couples. The ceramic bearing couples BIOLOX forte / BIOLOX delta have excellent wear properties. This 48 year old female patient suffered from bilateral femoral head necrosis. She was operated on in 1994. The picture shows the two BIOLOX DUO systems 11 years after implantation. 13

BIOLOX DUO Product Range The BIOLOX DUO system consists of three components which are assembled intraoperatively. A 28 mm BIOLOX forte ball head or a 28 mm BIOLOX delta ball head A BIOLOX forte bipolar shell with outer diameter from 42 mm to 56 mm (in 1 mm increments) A polyethylene fixation ring The BIOLOX DUO system can be combined with all hip stems, which are approved for use with the 28 mm BIOLOX forte ball heads or with the 28 mm BIOLOX delta ball heads. If necessary, the polyethylene fixation ring can be removed easily and the system can be disassembled. More Information More information about the BIOLOX DUO system including ani mated handling instructions and illustrations of biomechanics as well as abrasive and wear processes in hip replacements can be found in the BIOLOX inside App. The App is available in the App Store as well as in Google Play for Android devices. Download the BIOLOX inside App for Windows XP, Vista, 7 or 8, and Apple OS X devices at www.biolox.com/app. 14

42 43 44 45 46 47 48 49 50 51 52 28 53 54 55 BIOLOX delta BIOLOX forte UHMW-PE 56 15

CeraNews App for Apple and Android tablets and smartphones Scan the QR code CeramTec GmbH to learn more about Medical Products Division the BIOLOX DUO CeramTec-Platz 1 9 bipolar system D-73207 Plochingen Tel. +49 7153 611 828 Fax +49 7153 611 950 E-Mail: medical_products@ceramtec.de www.biolox.com This document is intended exclusively for experts in the field, i.e. physicians in particular, and is expressly not for the information of laypersons. The information on the products and / or procedures contained in this document is of a general nature and does not represent medical advice or recommendations. Since this information does not constitute any diagnostic or therapeutic statement with regard to any individual medical case, individual examination and advising of the respective patient are absolutely necessary and are not replaced by this document in whole or in part. The information contained in this document was gathered and compiled by medical experts and qualified CeramTec employees to the best of their knowledge. The greatest care was taken to ensure the accuracy and ease of understanding of the information used and presented. CeramTec does not assume any liability, however, for the up-to-dateness, accuracy, completeness or quality of the information and excludes any liability for tangible or intangible losses that may be caused by the use of this information. In the event that this document could be construed as an offer at any time, such offer shall not be binding in any event and shall require subsequent confirmation in writing. BIOLOX delta and BIOLOX forte ball heads and BIOLOX DUO are registered by CeramTec s customers. They are not registered / available in all countries. MT-00152-1708-EN-01 Printed 8.2017