Instruction for use of Foley Catheter General Description: Foley Catheter for single use consists of a thin, sterile tube made of Natural latex 100% coated with medical solid Silicone, ended with soft rounded closed tip with Safe and symmetrical balloon inflation. Intended Use: Foley Catheter for single use is a thin, sterile tube inserted into bladder to drain urine. Because it can be left in place in the bladder for a period of time, it is also called an indwelling catheter. It is held in place with a balloon at the end, which is filled with sterile water to hold it in place. The urine drains into a bag and can then be taken from an outlet device to be drained). There are two types of Foley catheter 2way that consist of tube has two lumens one lumen for urinary drainage which is to be connected to urine collection container, one lumen with one-way valve for inflation/deflation of Foley balloon, it used for people who have mobility issues, such as quadriplegia and 3 way consist of The tube has three lumens, one lumen for urinary drainage which is to be connected to urine collection container, one lumen with two-way valve for inflation/deflation of Foley balloon and one lumen for irrigation of bladder are used to help remove tissue chips, blood clots and other debris from the bladder after surgery, it used for people who need more protection against infection. Insertion of Foley catheter: The Foley catheter may introduce an infection into the bladder. The risk of infection in the urine increases with the number of days the catheter is in place. If the balloon is opened before the Foley catheter is completely inserted into the bladder, bleeding, damage and even rupture of the urethra can occur. Material: Foley Catheter consists of flexible tube made of Natural latex 100% coated with medical solid Silicone. Indications: Include providing relief when there is urinary retention, monitoring urine output for critically ill persons, managing urination during surgery, and providing end-of-life care. Foley catheters are used during the following situations:... On patients with acute urinary retention. Warning: Do not use ointments or lubricants having a petrolatum base. They will damage the catheter Visually inspect the product for any imperfections or surface deterioration prior to use. Inflate the balloon with sterile water to the volume stated on the inflation lumen of the catheter by using a water-filled Luer tip syringe. Do not use needle. Do not exceed recommended capacities. This is a single use device. Do not resterilize any portion of this device. Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient. - Do not use by unskilled and untrained personnel
NOTE: This device is single use for short term (less than 30 days) and not to be replaced with similar device as continuous use Precautions: To deflate catheter balloon: Gently insert a Luer slip tip syringe in the catheter valve. Never use more force than is required to make the syringe stick in the valve. Allow the pressure within the balloon to force the plunger back and fill the syringe with water. If you notice slow or no deflation, re-seat the syringe gently. Use only gentle aspiration to encourage deflation if needed. Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation. If necessary, contact adequately trained professional for assistance, as directed by hospital protocol. Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient. Packaging Artwork and Label Artwork: Package description Single unit sterilized by EtO gas placed in single Pouch made of PE/PP & Medical Paper, then each 20 unit are packed in small box then Each 40 boxes are packed in master carton. Type and Size
# Product Ref. No. Size 1 021 Foley Catheter 2 way (size 6) 2 022 Foley Catheter 2 way (size 8) 3 023 Foley Catheter 2 way (size 10) 4 024 Foley Catheter 2 way (size 12) 5 025 Foley Catheter 2 way (size 14) 6 026 Foley Catheter 2 way (size 16) 7 027 Foley Catheter 2 way (size 18) 8 028 Foley Catheter 2 way (size 20) 9 029 Foley Catheter 2 way (size 22) 10 030 Foley Catheter 2 way (size 24) 11 079 Foley Catheter 3 way (size 14) 12 080 Foley Catheter 3 way (size 16) 13 081 Foley Catheter 3 way (size 18) 14 082 Foley Catheter 3 way (size 20) 15 083 Foley Catheter 3 way (size 22) 16 084 Foley Catheter 3 way (size 24) Storage Condition The Temperature limit from -10 C to 40 C Sterilization: Tracheal Tube is sterilized by Euromed for Medical Industries. EtO sterilization, biological indicator testing and aeration process are performed by Euromed for Medical Industries Company.
Symbol: Euromed For Medical Industries Area No. (10), Block (i), Nasr City, Cairo, Egypt 0120 Tel: +20222725952/3 E-mail: euromed@euromed.com.eg MDSS GmbH Schiffgraben41 30175 Hannover, Germany Page 1 Of 1 Rev.no. Issue Date 01 8/03/2018