With the ongoing evolution of ever faster and more. Coronary CTA. Image Acquisition and Interpretation SYMPOSIA

Similar documents
Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Cardiac Computed Tomography

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

CT angiography techniques. Boot camp

General Cardiovascular Magnetic Resonance Imaging

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Index. radiologic.theclinics.com. Note: Page numbers of article titles are in boldface type.

Dual Energy CT of the Heart: Perfusion and Beyond

b. To facilitate the management decision of a patient with an equivocal stress test.

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

Cardiac Imaging Tests

ROLE OF MULTISLICE COMPUTED TOMOGRAPHY IN CARDIAC IMAGING

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Adapted Transfer Function Design for Coronary Artery Evaluation

Banding and Step-Stair Artifacts on the Cardiac-CT Caused By Pseudo-Ectopic Beats

THE ROLE OF HIGH END MULTI DETECTOR CT IN CORONARY IMAGING ESSAY

Combined Anatomical and Functional Imaging with Revolution * CT

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

NIH Public Access Author Manuscript Acad Radiol. Author manuscript; available in PMC 2009 September 16.

Coronary artery bypass grafting has been a historically. Multislice CT Evaluation of Coronary Artery Bypass Graft Patients SYMPOSIA

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Studies with electron beam computed tomography (EBCT) Imaging

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

What every radiologist should know about cardiac CT: A case-based pictorial review

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Low Dose Era in Cardiac CT

Angio-CT: heart and coronary arteries

Recent developments in cardiac CT

An Introduction to Dual Energy Computed Tomography

Calcium Scoring and Cardiac CT

Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA)

Radiation dose of cardiac CT what is the evidence?

Fulfilling the Promise

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Cardiac CT Angiography

Cardiac CT Lowering the Dose Dramatically

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Non-invasive Coronary Angiography: the Role, Limitations and Future of 64-Slice Spiral Computed Tomography Coronary Angiography

Disclosure Information

Patient preparation and coronary CTA techniques. Gregory Kicska, M.D. Ph.D. University of Washington, Thoracic Imaging

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

Multisclice CT in combination with functional imaging for CAD. Temporal Resolution. Spatial Resolution. Temporal resolution = ½ of the rotation time

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

Interpreting CT Angiography: Three-Dimensional Reconstruction Techniques

MR Advance Techniques. Cardiac Imaging. Class IV

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Coronary CT Angiography

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Computer Aided Detection and Diagnosis: Cardiac Imaging Applications

Cardiac CT: Your chest pain patient CAN be discharged from the Emergency Department

Noninvasive Coronary Angiography with 16 Detector Row CT: Effect of Heart Rate 1

Coronary Artery Anomalies from Birth to Adulthood; the Role of CT Coronary Angiography in Sudden Cardiac Death Screening

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

Computed Tomography of the Coronary Arteries

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

2 Cardiovascular Computed Tomography: Current and Future Scanning System Design

Noncoronary Cardiac MDCT

Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

Pushing the limits of cardiac CT. Steven Dymarkowski Radiology / Medical Imaging Research Centre

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

Cardiac CT Techniques in Neonates (and infants)

CORONARY ANATOMY WITH MULTIDETECTOR COMPUTED TOMOGRAPHY ANGIOGRAPHY*

Case 47 Clinical Presentation

ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

X-Ray & CT Physics / Clinical CT

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Cardiac MRI in ACHD What We. ACHD Patients

Pulmonary Embolism. Thoracic radiologist Helena Lauri

A Noninvasive Assessment of CAD

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Purpose. Methods and Materials

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

Coronary angiography is the standard way of visualizing

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

Managing Radiation Risk in Pediatric CT Imaging

Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

Multidetector CT Angiography for the Detection of Left Main Coronary Artery Disease. Rani K. Hasan, M.D. Intro to Clinical Research July 22 nd, 2011

Coronary artery disease remains

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Imaging Strategies for Endovascular Cardiovascular Procedures and Percutaneous Aortic Valves. Roy K Greenberg, MD

Case Report. Heon Lee, MD, PhD 1, Seok-Yeon Kim, MD 2, U. Joseph Schoepf, MD 3 CASE REPORT INTRODUCTION

Protocols in Cardiac CT Dr. Bruce Precious Dalhousie University Friday, April 15, 2016

TITLE: Multi-Slice Computed Tomography Coronary Angiography for Coronary Artery Disease: A Review of the Clinical Effectiveness and Guidelines

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

MSRS 6473 Vascular Noninvasive Imaging Procedures

Transcription:

SYMPOSIA Image Acquisition and Interpretation Josef Matthias Kerl, MD,*w Lars K. Hofmann, MD,z Christian Thilo, MD,*y Thomas J. Vogl, MD,w Philip Costello, MD,* and U. Joseph Schoepf, MD*y Abstract: Computed tomography (CT) of the heart, because of ongoing technical refinement and intense scientific and clinical evaluation, has left the research realm and has matured into a clinical application that is about to fulfill its promise to replace invasive cardiac catheterization in some patient populations. By nature of its target, the continuously moving heart, CT coronary angiography is technically more challenging than other CT applications. Also, rapid technical development requires constant adaptation of acquisition protocols. Those challenges, however, are in no way insurmountable for users with knowledge of general CT technique. The intent of this communication is to provide for those interested in and involved with coronary CT angiography a step-by-step manual, introducing our approach to performing coronary CT angiography. Included are considerations regarding appropriate patient selection, patient medication, radiation protection, contrast enhancement, acquisition and reconstruction parameters, image display and analysis techniques and also the radiology report. Our recommendations are based on our experience which spans the evolution of multidetector-row CT for cardiac applications from its beginnings to the most current iterations of advanced acquisition modalities, which we believe herald the entrance of this test into routine clinical practice. Key Words: coronary CTA, multidetector-row CT (J Thorac Imaging 2007;22:22 34) With the ongoing evolution of ever faster and more sophisticated multidetector-row computed tomography (MDCT) technology, CT of the heart has evolved into an examination that is applied to a broad variety of clinical indications. 1 With the advent of the latest iterations of MDCT technology, both temporal and From the *Department of Radiology; ydivision of Cardiology, Department of Medicine, Medical University of South Carolina, SC; winstitute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Frankfurt; and zsiemens Medical Solutions, Division CT, Forchheim, Germany. U. Joseph Schoepf is a medical consultant to Berlex, Bracco, General Electric, Siemens, and TeraRecon and receives research support from Berlex, Bracco, General Electric, Medrad, and Siemens. Reprints: U. Joseph Schoepf, MD, Department of Radiology, Medical University of South Carolina, 169 Ashley Avenue, Charleston, SC 29425 (e-mail: schoepf@musc.edu). Copyright r 2007 by Lippincott Williams & Wilkins spatial resolution of coronary CT angiography (CTA) have improved to a point where the threshold to routine noninvasive assessment of the coronary arteries for atherosclerotic disease may have been crossed. Imaging of the heart has always been technically challenging, because of the heart s continuous motion. The development of electrocardiography (ECG)-synchronized MDCT scanning and reconstruction techniques 2 4 has provided fast volume coverage and high spatial and temporal resolution as a prerequisite for successful cardiac imaging. 5 The exceedingly powerful technology which enables performance of coronary CTA, however, transcends routine CT applications and needs to be used in a manner to provide optimized results with the least degree of invasiveness for the patient. Our experience performing contrast enhanced coronary CTA has evolved over the years since the introduction of MDCT and has encompassed every single evolutionary step of this technology up to the most current generation of dualsource CT (DSCT). The purpose of this communication is to share our experience with those interested in and involved with coronary CTA to facilitate the beneficial application of this procedure. PATIENT PREPARATION IV Access Intravenous access is preferably established in a cubital vein. Especially, if a left internal mammary arterial bypass graft is to be assessed, an access site in the right arm should be chosen to prevent streak artifacts arising from dense contrast material in the left subclavian vein from interfering with the evaluation of left internal mammary arterial origin. Because of the fairly fast injection rates of 4 to 5 ml/s, an 18-G catheter or larger should be used, whenever possible. ECG Lead Attachment Ordinarily, a 3-lead ECG is used for cardiac CT. A stable reading of the patient s ECG with clear identification of the QRS-Complex is a prerequisite for successful retrospective ECG-gating. To establish good electrical contact and prevent lead detachment with consecutive signal loss during scan acquisition, use of additional conductive gel and shaving of overly hairy attachment sites are recommended. 22 J Thorac Imaging Volume 22, Number 1, February 2007

J Thorac Imaging Volume 22, Number 1, February 2007 Rate Control Rate Control for Improving Image Quality For a variety of reasons, slow heart rates are highly desirable for cardiac CT using 4-slice to 64-slice scanners: Slow heart rates relatively prolong the cardiac phases with little cardiac motion, that is, end-diastolic relaxation and end-systolic contraction, so that a reconstruction interval of a defined duration can be safely placed within these phases without inclusion of preceding or consecutive portions of the heart cycle that contain motion. In our practice, we aim at a target heart rate of between 50 and 65 beats per minute (bpm) for our 64-slice CT scanners. With DSCT, the newest scanner generation, heart rate control might not be necessary anymore. In our experience, DSCT allows scanning patients with high (ie, 120 to 140 bpm) and irregular heart rates with diagnostic results (Fig. 1). These scanners employ 2 x-ray sources and 2 corresponding detectors offset by 90 degrees, thus providing a temporal resolution equivalent to a quarter of the gantry rotation time (ie, 83 ms), independent of the patient s heart rate. 6 Rate Control for Single-segment Reconstruction in Single-source CT Scanners As a direct consequence of this high temporal resolution, image reconstruction can be ordinarily performed using single-segment reconstruction, that is, based on the projections that are acquired during a single heartbeat. Single-segment reconstruction has theoretical advantages over multisegment reconstruction algorithms that are implemented on all available cardiac CT scanners. At multisegment reconstruction, the projections that are needed to form a single section are sampled over 2 to 4 consecutive heart beats. 5 Although this approach improves temporal resolution, which is beneficial for faster heart rates, it requires that the heart follows the exact same motion pattern for each of the 2 to 4 heart beats during which projection sampling for reconstruction of a single section occurs. This, however, is unreasonable to expect, given the variability of cardiac motion patterns even under physiologic conditions so that spatial inconsistencies within the data inevitably occur with the use of multisegment reconstruction. In our practice, we strive to avoid the use of multisegment reconstruction algorithms by appropriately reducing the heart rate with 64-slice CT and use it exclusively in patients with heart rates >80 bpm, above which, in our experience, the benefits of improved temporal resolution outweigh the risk of spatial inconsistency. Rate Control for Radiation Protection Up to the generation of 64-slice CT, rate control has been directly related to patient radiation exposure at cardiac CT. Significant dose savings can be realized with ECG-gated dose-modulation ( ECG-pulsing ). 5,7 With this approach, the nominal tube output is only applied FIGURE 1. Contrast enhanced, retrospectively ECG-gated dual-source coronary CTA in a 62-year-old man with persistent atrial fibrillation and tachyarrhythmia after pulmonary vein ablation therapy. The heart rate during the CT scan varied between 67 and 150 bpm (A). Despite this high and irregular heart rate, the stable temporal resolution of 83 msec enabled by this technology resulted in a data set of sufficient diagnostic quality. Volume rendered displays both, during diastole (B) and systole (C) are of comparable image quality and do not show motion or misregistration artifacts. r 2007 Lippincott Williams & Wilkins 23

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 during the particular phase of the cardiac cycle at which images are most likely to be reconstructed. Over the rest of the cardiac cycle, the tube output is reduced. However, the use of ECG-gated dose-modulation is limited to patients with slow and steady heart rates, in whom the optimal time-point for image reconstruction predictably occurs during diastole (Fig. 2). At faster heart rates, ECG-gated dose-modulation increasingly looses its efficacy, as the period of reduced tube output becomes progressively shorter relative to the cardiac cycle. More importantly, with faster heart rates, the optimal timepoint for image reconstruction becomes more difficult to predict and, in the case of 64-slice CT frequently occurs during the end-systolic phase of total myocardial contraction (Fig. 3). Because with ECG-gated dosemodulation the radiation level is typically reduced during systole, diagnostic quality will inevitably be compromised during image reconstruction so that use of ECG-gated dose-modulation is not recommendable for faster heart rates. This way, rate control has become a crucial factor in the endeavor of keeping radiation exposure at cardiac CT within reasonable limits. In our practice, with 64-slice CT, we used ECG-gated dose-modulation in patients with steady heart rates <65 bpm. We feel that in patients with faster and more irregular heart rates ECG-gated dosemodulation limits, our options with regard to the selection of the optimal reconstruction time-point too much as to recommend its general use. These rules do not apply for the use of DSCT. Because of a temporal resolution window of only 83 ms, ECG dose-modulation can be applied much more effectively. Full energy windows covering only a 10% window of the cardiac cycle are feasible. Additionally, DSCT allows the adaptation of the pitch to the patient s heart rate, because multisegment reconstruction for higher heart rates will not be required. The table feed can be efficiently adapted to the patient s heart rate and significantly increased at higher heart rates. 6 As shown by McCollough et al, 8 this may reduce radiation dose in cardiac CT by up to 50% compared with single-source CT. Rate Control: Practical Aspects In our practice, we routinely used intravenous b-blocker (Metoprolol Tartrate, Lopressor, Novartis, East Hanover, NJ) for controlling our patients heart rate with very satisfactory results and without complications to date. Contraindications for the use of b-blockers include chronic obstructive pulmonary disease, asthma, sensitive to b-agonists, second-degree or third-degree heart block; hypotension (<100 mm Hg systolic). In the absence of contraindications, we inject an initial bolus of 5 mg of Metoprolol while the patient is already on the scanner table and preparations for scanning ensue. If the ventricular response is unsatisfactory, that is, the average heart rate remains >70 bpm, we inject up to 2 additional doses (15 mg total maximum) of Metoprolol. After administration of 3 doses, we commence scanning, regardless of the heart rate that is eventually achieved after b-blocker administration. Oral administration of b-blockers is an alternative means of rate control, which compared with our intravenous protocol, exerts higher demands on operational logistics. If oral administration is preferred, ideally, the regimen should be commenced the night before the scan with an initial dose of 50 to 100 mg of Metoprolol. Thirty to sixty minutes before the scan, FIGURE 2. Contrast enhanced, retrospectively ECG-gated 64-slice coronary CTA in a 60-year-old man, referred for patency evaluation of a left internal mammary artery bypass graft to the left anterior descending artery (LAD) and 3 saphenous vein grafts to the 3 major coronary territories. Display in volume rendering technique (left upper panel) seen from an anterior perspective. A slow and steady heart rate of E60 bpm enables successful use of ECG-pulsing for the radiation protection. Full nominal tube current (indicated in red in the patient s ECG, lower panel) is only applied during diastole, the cardiac phase which is subsequently used for image reconstruction at 60% RR, which results in full image quality with high signal-to-noise ratio (right upper panel). During other cardiac phases, which are not used for image reconstruction, the tube current is lowered to 20% of the nominal output (indicated in blue in the patient s ECG, lower panel). 24 r 2007 Lippincott Williams & Wilkins

J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 3. Contrast enhanced, retrospectively ECG-gated 64-slice coronary CTA in a 70-year-old woman, referred for equivocal perfusion abnormalities at cardiac single photon emission CT. Because of the fast and irregular heart rate of E120 bpm (lower panel), the optimal reconstruction interval cannot reliably be predicted, and ECG-pulsing technique was not used. Different from the patient in Figure 2, in whom the optimal reconstruction interval was predictably found during diastole, image reconstruction at 60% RR in this patient (A) results in considerable cardiac motion, which blurs the RCA on transverse images (right upper panel in A) and entirely prevents visualization of the vessel on volume rendered images (left upper panel in A), while the LAD is contorted. However, as full tube current is maintained throughout the scan (indicated in red in the patient s ECG, lower panel), flexibility is maintained to reconstruct data during any phase of the cardiac cycle. Subsequent reconstruction of the same data set during full systolic contraction (B) at 25% RR results in nearly motion-free transverse images (right upper panel in B), which enables clear display of the LAD and RCA at volume rendering (left upper panel in B). another dose is given, followed by a third dose in the absence of adequate ventricular response. There is less experience with alternative rate-controlling medications. However, if there are contraindications for use of b-agonists (see above), an attempt with calcium channel blockers may be worthwhile. Calcium channel blockers can be administered either intravenously [0.25 mg/kg bodyweight (up to 25 mg total) Diltiazem, Cardizem Monovial, Hoechst Marion Roussel, Kansas City, MO] or as an oral regimen with 30 mg of regular release Diltiazem (Cardizem, Biovail, Toronto, Canada). In our practice, all patients who receive rate-controlling medications or nitroglycerin (NTG) (see below) are monitored for 30 minutes after administration of the last dose. Blood r 2007 Lippincott Williams & Wilkins 25

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 pressure measurements are performed before administration of the drug and before discharge. Patients who receive more than 1 dose of b-blockers are instructed not to drive or operate machinery for 3 hours after the administration of the drug. NTG No systematic studies are available to support the use of NTG in the context of cardiac CT. In patients referred for coronary CTA for suspected coronary artery disease, we administer a 0.4 mg NTG tablet (NitroQuick, Ethex, St Louis, MO) sublingually 2 minutes before the scan with the theoretical rationale of widening the coronaries for better visualization and suppressing coronary artery spasms that may mimic stenosis at coronary CTA especially in younger individuals. Sublingual spray can be used alternatively. Contraindications for NTG comprise hypotension, early myocardial infarction, severe anemia, increased intracranial pressure, and known hypersensitivity to NTG. We also do not give NTG to patients who recently took nitrate-based medication (Viagra, Cialis, Levitra) for erectile dysfunction. SCANNING PARAMETERS Gantry Rotation Speed and Collimated Section Width At coronary CTA, the target anatomy is minute, tortuous, and moving rapidly. Accordingly, as a universal rule that applies to MDCT scanners of all manufacturers, for optimally performing coronary CTA one can never slice too thin or spin too fast. Thus, at coronary CTA, regardless of the scanner type used, the thinnest possible collimation and the fastest gantry rotation time should be chosen. An exception is the rare situation where the patient s heart rate is so slow (typically <50 bpm), that use of a somewhat slower gantry rotation with slower pitch is required to avoid gaps in the acquired data set. 9 Another scenario where choice of a somewhat slower gantry rotation speed may be considered is the severely obese patient, where slower gantry rotation may be helpful to enhance the photon flux and improve the signal-to-noise ratio at coronary CTA. DSCT, with its 2 x-ray tubes, is considerably better suited than singlesource CT for suppressing image noise in obese patients. A reduction in gantry rotation speed with this latter technology is generally not necessary. Rather, a heart rate range can be selected that is lower than the patient s actual heart rate which results in an artificially lower table speed and accumulation of dose to suppress image noise. Tube Current and Voltage Issuing general recommendations for the selection of tube current settings is challenging, as the appropriate tube current level depends on several scanner specific variables, such as the collimated section width and the gantry rotation speed. As with all CT applications, the ALARA (As Low As Reasonably Achievable) principle applies, that calls for patient specific adjustment of the scanner settings to the patient s body habitus so that the lowest possible tube current setting is chosen that still results in a diagnostic study. When scanning normal sized adults for suspected coronary artery disease with 0.6 mm collimation and 330 msec gantry rotation, we ordinarily adjust the tube current to 750 to 800 mas eff w with singlesource CT, always employing all means available for reducing radiation exposure to the patient (ie, ECGpulsing, see above). With DSCT, scanning parameters of 120 kv per tube with a current of 560 ma and the use of anatomic tube current modulation is ordinarily chosen. The gantry rotation time is usually set to 0.330 seconds and the pitch ranges from 0.2 to 0.43 depending on heart rate. As the x-ray absorption of iodine is inversely proportional to the tube potential, very high tube voltage settings (ie, 140 kv) are generally not recommendable for contrast enhanced CTA. When scanning normal sized or larger adults for suspected coronary artery disease, we ordinarily employ a tube potential of 120 kv. Substantial dose savings can be realized by lowering the tube voltage to 100 or 80 kv, while the level of vascular attenuation increases. Thus, in slim adults the tube voltage can be safely lowered to 100 kv with very satisfactory results in our experience. Similarly, depending on the size of the patient, we routinely use 100 or 80 kv, when performing cardiac CT in adolescent or pediatric patients for suspected coronary artery anomalies or other congenital cardiovascular disorders. 10 CONTRAST ENHANCEMENT Level of Enhancement High and consistent vascular enhancement within the vessel lumen is a prerequisite for successful coronary CTA. Adequate enhancement is needed for visualization of the vessel wall, of small side branches of the coronary tree and, especially in obese patients, to compensate for increased levels of image noise that limit contrast resolution at thin-section coronary CTA. In addition, high and homogenous enhancement serves as the basis for threshold-dependent 3-dimensional visualization techniques. To achieve the desired high vascular enhancement, we use high concentration 350 to 370 mgi/ml nonionic contrast media with a fast injection rate of 5 to 6 ml/s. It has been argued that exceedingly high intralumenal contrast may interfere with the detection of calcified atherosclerotic plaque. In our experience, this pitfall can be easily avoided by appropriately adjusting window center and width (CE100 HU; WE700 HU) according to the level of enhancement hat was achieved in the individual patient. Saline Chasing Technique Significant scientific effort is currently directed at understanding and optimizing contrast dynamics at CTA. 11,12 Insights gained from ongoing investigations are continuously implemented in commercially available automated injectors. One such implementation that has 26 r 2007 Lippincott Williams & Wilkins

J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 4. Contrast enhanced, retrospectively ECG-gated CT coronary angiography without saline chasing technique. Display as transverse section (A) and volume rendering (B), seen from a left anterior oblique perspective. A streak artifact emanating from dense contrast material in the right heart (arrow in A) overlies the RCA and causes artifactual stenosis (arrow in B) of the proximal RCA. become imperative for coronary CTA is the use of a saline chaser enabled by dual-syringe injection systems. Use of a saline chaser aims at better utilization of the injected contrast media by prolonging the plateau-phase of contrast. More importantly, use of a saline chaser reduces the occurrence of streak artifact from dense contrast media in the superior vena cava and the right heart chambers. At coronary CTA, such streak artifacts have the potential to significantly limit the evaluation of the right coronary artery (RCA), and may simulate stenosis especially at 2-dimensional and 3-dimensional image postprocessing (Fig. 4). However, the occurrence of streak artifacts may be reduced or entirely avoided, if at the time of image acquisition the contrast material is flushed from the right heart by use of saline chaser technique. On the other hand, a complete void of contrast r 2007 Lippincott Williams & Wilkins 27

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 5. Contrast enhanced, retrospectively ECG-gated CT coronary angiography in 3 different patients. Use of a monophasic injection (left) of iodine only, using a single syringe injector, results in dense streak artifacts in the right heart. Use of a biphasic injection (middle) with a dual-syringe injector and saline chasing technique flushes residual contrast from the right heart and avoids artifacts; however, the right cardiac chambers can no longer be assessed. A triphasic injection, also using a dual-syringe injector, with simultaneous flow (right) from 2 syringes administers a mixture of contrast and saline during the second injection phase. This provides sufficient enhancement for assessment of the right heart while streak artifacts from dense contrast material can generally be avoided. in the right heart is undesirable, as right heart analysis is precluded. We aim at improving right heart visualization by using the 3 phases of injection where the initial iodine bolus is followed by a saline/contrast mixture enabled by simultaneous injection from both syringes (Dual Flow Technology, Medrad, Pittsburgh, PA) and a final saline chaser (see below). This strategy provides sufficient enhancement for assessment of the right heart (Fig. 5) for detection of thrombo-emboli, tumors, etc, while streak artifacts from dense contrast material can generally be avoided. Contrast Protocol In our practice, the individual delay time is determined by injection of a 20 ml contrast media test bolus at 5 ml/s (64-slice CT) or 6 ml/s (DSCT), followed by 50 ml of saline using a dual-syringe injector (Stellant D, Medrad). Repeated scanning at the same z-position at the level of the aortic root is performed to monitor the arrival and passage of the test bolus. The peak time of test bolus enhancement is used as the delay time. The contrast volume for the actual coronary CTA scan is individually computed according to the following formula: Volume (ml) = scan time (s) 5 (64-slice CT) or 6 (DSCT). The injector is preprogrammed to deliver 50 ml of a 30% contrast media/70% saline mixture during the second phase of injection, followed by a final 30 to 50 ml saline chaser, all injected at 5 ml/s (64-slice CT) or 6 ml/s (DSCT), respectively. IMAGE RECONSTRUCTION Single-segment Versus Multisegment Reconstruction Algorithms For considerations regarding use of single-segment versus multisegment reconstruction, please see above discussion on rate control ( Rate Control for Single- Segment Reconstruction with Single Source CT Scanners section). In general, we avoid the use of multisegment reconstruction in patients with heart rates of less than 80 bpm with 64-slice CT and entirely with DSCT. Choosing the Optimal Reconstruction Interval For the assessment of cardiac morphology, a phase with minimal cardiac motion is preferably chosen for placement of the image reconstruction interval. To define the starting point of the reconstruction interval within the cardiac cycle, absolute and relative approaches are available on most cardiac CT scanner types. With an absolute approach, each image reconstruction interval is placed in the cardiac cycle with a predefined temporal distance (eg, 400 ms) before or after an R-peak in the ECG. With a relative approach, the starting point of the image reconstruction interval is defined as a certain percentage (eg, 60%) of the duration of the cardiac cycle. We use the relative, percentage-based approach for 64-slice CT and an absolute approach for DSCT. If available, a preview function is preferably used for determining the optimal reconstruction phase with the least cardiac motion. Typically, the preview series consists 28 r 2007 Lippincott Williams & Wilkins

J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 6. Contrast enhanced, retrospectively ECG-gated DSCT coronary angiography. Same patient as in Figure 9. Use of a preview function identifies the most suitable cardiac phase for the image reconstruction. Shown are 6 representative transverse sections at the same z-position at the level of the aortic valve, out of a series of 20 reconstructions at different RR positions in 5% increments (0% to 95% RR), covering the entire cardiac cycle. Image reconstructions during full cardiac contraction at end systole (45% RR) and during full relaxation during diastole (60% RR) are suitable to sufficiently suppress cardiac motion and enable clear assessment of the stenosed RCA origin, whereas this area is blurred during other phases of the cardiac cycle. Image reconstruction during early (15%) and late (90%) phases of the cardiac cycle also show higher levels of image noise, owing to our routine use of ECG-pulsing techniques during these phases with DSCT. of 20 images (Fig. 6), reconstructed at 20 different RR positions in 5% increments (0% to 95% RR) at the same z-position at the mid-level of the heart. The phase that shows the least motion artifacts in both, the left and RCA system is chosen for the image reconstruction. In cases where the right and left coronary artery show diverging motion patterns, more than one reconstruction is performed for optimized visualization of both arterial systems. If a preview function is not available, a first image reconstruction of the data set can be performed at 60% RR (Fig. 2), which has been shown to result in diagnostic image quality in most patients, 13 especially at slower, regular heart rates. With the improved temporal resolution of newer scanners, late systole with total cardiac contraction (ie, 30% to 40% RR) has emerged as a second suitable time-point for image reconstruction (Fig. 3), where cardiac motion is at a minimum. In our experience, image reconstruction during late systole yields diagnostic results in most patients with a faster heart rate and is especially well suited for visualization of the RCA. Reconstruction Parameters Field of View To maximize spatial resolution, the smallest possible field of view should be chosen that encompasses the entire anatomy of the heart, for performing image reconstruction at CT coronary angiography. In addition, for each coronary CTA study, we perform a full field of view reconstruction of the entire chest along the acquired z-volume with 3-mm section thickness and a lung algorithm, to assess for incidental lung pathology. For specialized applications, such as triple rule-out scanning, we perform the 2 reconstructions described above and a third reconstruction with 1-mm section thickness, a vascular algorithm and a field of view that encompasses the entire chest, to evaluate for vascular pathology of the pulmonary circulation and the thoracic aorta. Section Thickness Generally, to avoid artifacts, thin-section MDCT data should be reconstructed with a section width that is r 2007 Lippincott Williams & Wilkins 29

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 7. Contrast enhanced, retrospectively ECG-gated 64-slice coronary CTA in a 27-year-old woman status postmyocardial infarction and subsequent LAD stent placement referred for noninvasive disease surveillance because of desired pregnancy. Three-dimensional volume rendered display of the entire cardiac volume (A) and of the automatically extracted coronary artery tree (B) show the location of the stent (arrow) in the proximal LAD. Reconstruction of the same data set with a routine coronary CTA algorithm (C) and a more edge enhancing algorithm (D) dedicated to the assessment of coronary artery stents and segments with dense calcification. Display of the LAD as curved MPR (C, D) show the stent (arrow) in the proximal portion of the vessel. The dedicated stent reconstruction algorithm (D) enables somewhat more detailed assessment of the metallic stent struts and the patent lumen, particularly in the more distal portion of the stent. slightly wider than the collimated section width. 14 For example, if the scan was acquired with 0.6-mm collimated section width, the next higher available reconstruction thickness (eg, 0.75 mm) should be chosen for the image reconstruction. Forty to sixty percent increment is ordinarily used for the image reconstruction at coronary CTA, which in our experience results in a somewhat crisper and sharper delineation of the coronary artery tree but does not necessarily improve diagnostic accuracy compared to contiguous image reconstruction without overlap. Reconstruction Algorithm ( Kernel ) Most CT scanners used for coronary CTA offer a dedicated reconstruction filter (kernel) for the image reconstruction of cardiac CT studies. Typically, these kernels maintain a degree of edge enhancement, to provide the spatial resolution necessary to visualize small vascular detail. Ideally, the kernels are also optimized to suppress image noise as much as possible, to improve the visual impression and maintain contrast resolution for evaluation of the myocardium and the vessel wall. For the evaluation of coronary artery stents, it is recommendable to use a kernel with even stronger edge enhancing characteristics and greater spatial resolution. This approach suppresses beam hardening artifacts to some extent and provides better delineation of metallic stent struts (Fig. 7) than the algorithms which are routinely used at coronary CTA. This approach may also somewhat increase the diagnostic yield in the presence of heavy calcifications, which pose a similar problem as dense stent struts for the evaluating luminal integrity. Although dedicated reconstruction algorithms improve visualization of coronary artery stents, our ability to assess for stent patency with CT is extremely variable and depends on the overall quality of the data set and the size and material of the stent. Because of this variability, reliable assessment of stents cannot be expected on a routine basis and we discourage use of CT for dedicated stent follow-up. 30 r 2007 Lippincott Williams & Wilkins

J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 8. Contrast enhanced, retrospectively ECG-gated dual-source CTA in a 69-year-old man after LAD infarction. The transverse section (A) shows myocardial thinning and calcification (arrow) of the LAD myocardial perfusion territory predominantly in the anterior wall of the left ventricle. Three-dimensional volume rendered display (B) shows the full extent of dystrophic calcification owing to chronic ischemia. CT-based assessment of cardiac function (C) shows akinesis of the anterior wall, indicated by dark cold spectrum colors in an automatically generated functional model of the left ventricle. IMAGE DISPLAY FOR LESION DETECTION AND GRADING Diagnostic Strategies For cardiac applications, the role of advanced, dedicated image display, and analysis tools is considerably greater than for general CT applications. Review of the individual transverse source images, however, cannot be abandoned and must be a part of the diagnostic process in each case. The transverse source images are richest in information regarding incidental mediastinal findings, artifacts (Fig. 4), and the overall atherosclerotic plaque burden within the coronary artery tree. Every postprocessing step necessarily and by design reduces the available information for the sake of more intuitive image visualization. Depending on the particular indication for performing cardiac CT, we employ slightly different strategies for our diagnostic approach. When assessing bypass grafts or the left atrium and pulmonary veins in the context of ablation therapy for cardiac arrhythmia, a 3-dimensional volume rendered model is used for quick initial orientation, for example regarding the type and course of bypass grafts or the general configuration of the pulmonary venous return. This is followed by the review of transverse source images for the detection and grading of graft lesions or pulmonary vein stenosis and also additional or alternative findings in the chest. For suspected coronary artery stenosis, the transverse source images are initially reviewed, to obtain general information on the presence, location, and composition (calcified vs. noncalcified) of atherosclerotic lesions 15 and also consequences of ischemic disease, such as myocardial perfusion deficits or scarring (Fig. 8). Once lesions are detected, stenosis severity is evaluated by using simple visualization tools that enable a more comprehensive, condensed display of the data set. Multiplanar reformats (MPRs, see below) are easy to use basic tools and are available on most CT scanners. For improved detection and grading of coronary artery lesions, we use dedicated visualization and analysis tools (see below), whenever interpreting a scan performed for suspected stenotic disease. Different from the evaluation of bypass grafts and pulmonary veins, there is a little diagnostic value in performing 3-dimensional volume rendered displays for suspected coronary artery disease, as lesions are frequently obscured or overestimated, depending on the rendering parameters. In our practice, 3-dimensional rendering is exclusively used for intuitive communication of our findings to referring physicians and patients. MPRs For visualization of the coronary artery tree at contrast enhanced CT coronary angiography, MPRs 16 are widely used and recommended as a robust and easy to perform secondary visualization tool for data viewing. Because of the isotropic (equal voxel dimensions in x-axis, y-axis and z-axis) or near isotropic nature of r 2007 Lippincott Williams & Wilkins 31

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 9. Contrast enhanced, retrospectively ECG-gated dual-source CTA in a 72 year old woman with atypical chest pain. Same patient as in Figure 6. The axial source images (left in A) and the sagittal MPR (middle in A) clearly demonstrate a moderate ostial stenosis (arrow) of the RCA, adjacent to dense calcifications in the right coronary sinus of the aorta. The lesion is more difficult to detect in the coronal reformat (right in A). Display as automatically generated curved MPR (B) is best suited for stenosis detection and grading, whereas display as 3-dimensional volume rendering (C) fails to show the full extent of the lesion. high-resolution CT acquisitions, image data can be rearranged in arbitrary imaging planes with comparable image quality as in the original transverse section. MPRs serve the purpose of enabling views of coronary artery lesions from different angles and perspectives, which enables better assessment of stenosis severity and residual perfused lumen than can be appreciated by only a single projection. This is of particular importance in the presence of severe calcifications, where a single view often fails to display residual lumen in the vicinity of a heavily calcified plaque (Fig. 9). Advanced Visualization Tools Advanced software tools have become available and are being continuously refined that facilitate viewing and analysis of large volume data sets. The common rationale 32 r 2007 Lippincott Williams & Wilkins

J Thorac Imaging Volume 22, Number 1, February 2007 FIGURE 10. Contrast enhanced, retrospectively ECG-gated 64-slice coronary CTA in a 59-year-old man with atypical chest pain. Illustrated is the workflow of coronary CTA analysis, using dedicated visualization platforms. A circumscribed, short segment high degree stenosis (arrow) in the proximal LAD is difficult to detect on transverse, sagittal, or coronal MPRs (A). Postprocessing consists in automated sculpting of the chest wall to enable an unobstructed view of the heart (B), displayed as volume rendering. Automated extraction of the coronary arteries from the contrast enhanced data set is performed (C). The extracted coronary artery is displayed as an automatically generated MPR (D), which affords intuitive visualization of the entire vessel and the circumscribed lesion. Automated assessment of stenosis severity (E) at the level of the lesion shows 78% luminal obstruction (diameter measurement). Catheter angiography (F) later confirms the site and severity of the LAD lesion (arrow). of most of these software platforms is to provide a means for rapid analysis of the coronary artery tree for the detection and grading of stenosis. Typically, the first step of postprocessing after review of the transverse sections and MPRs (Fig. 10A) consists in automated sculpting of the chest wall to enable an unobstructed view of the heart (Figs. 9C, 10B). Threshold-dependent or contour-dependent extraction of the coronary arteries from the contrast enhanced data set is then performed (Fig. 10C). Most software applications enable unraveling of the tortuous course of the extracted coronary artery, which affords intuitive visualization of the entire vessel, typically as an automatically generated MPR (Figs. 9B, 10D). Lastly, most available software platforms provide tools for quantitative evaluation of stenosis severity (Fig. 10E) based on cross-sectional measurements of vessel diameter or area. Naturally, the accuracy of such tools for stenosis grading is directly related to the image quality and spatial resolution of the original acquisition and subject to the inherent limitations of coronary CTA for assessing stenosis severity. Therefore, as with any automated assessment in medicine, the measurement results of vessel analysis tools should not be trusted blindly, but the experience and acumen of the physician is still required to validate the results in the appropriate clinical context. THE REPORT We use a standardized template for reporting findings at coronary CTA. With the exception of a more detailed discussion of the coronary arteries and other cardiac structures, our coronary CTA reports are not fundamentally different from general radiology reports and include all pathology, variations, and changes that are visible on the different reconstruction series. In the Procedure section, we include the items that are pertinent to appropriate billing in our local health care environment. These items may be different in other geographical areas, but generally include the section thickness, use of retrospective ECG-gating, contrast volume and injection speed, medications used, and image postprocessing methods, such as MPRs or 3-dimensional reconstructions. In the Findings section, we begin with describing general cardiac and great vessel anatomy, commenting on the myocardium (thickness, areas of infarction, scars etc), the cardiac chambers, valves, pericardium, pulmonary veins, pulmonary arteries, and aorta. A section is dedicated to incidental findings in the chest wall, mediastinum, and lung, for example, the description and classification of lung nodules including recommendations for the follow-up according to standard clinical practice. 17 In the cardiac section, we report on the r 2007 Lippincott Williams & Wilkins 33

Kerl et al J Thorac Imaging Volume 22, Number 1, February 2007 presence and location of cardiac devices, catheters etc. When coronary artery bypass grafts are present, we describe the type, origin, course, site of anastomosis, the presence, location, and degree of graft stenosis and also the quality of the run-off within the grafted vessel distal to the anastomosis. The presence and course of anomalous coronary arteries is noted, and also the coronary supply type (right-dominant, left-dominant or codominant). Finally, each coronary artery (left main, left anterior descending artery, circumflex, RCA) is separately commented on with regards to the presence and type of atherosclerotic plaque burden (calcified vs. noncalcified). For reporting the site of stenosis, use of the American Heart Association/American College of Cardiology segmental model, which is widely employed for research purposes, has proved less useful for routine clinical interpretation. We rather use the common terminology found in routine catheter reports, that describe lesions as located in the proximal, mid, or distal portion of the respective main coronary arteries or their side branches (left anterior descending artery: diagonals and septals, circumflex: obtuse marginals, RCA: acute marginals). We use our visualization methods (see above) to determine the severity of stenosis as the percentage of luminal obstruction, on the basis of cross-sectional measurements of vessel diameter or area. REFERENCES 1. Schoepf U. CT of the Heart: Principles and Applications. Totowa, NJ: Humana Press; 2004. 2. Ohnesorge B, Flohr T, Becker C, et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology. 2000;217:564 571. 3. Flohr T, Schoepf U, Kuettner A, et al. Advances in cardiac imaging with 16-section CT systems. Acad Radiol. 2003;10:386 401. 4. Ohnesorge BM, Hofmann LK, Flohr TG, et al. CT for imaging coronary artery disease: defining the paradigm for its application. Int J Cardiovasc Imaging. 2005;21:85 104. 5. Schoepf UJ, Becker CR, Ohnesorge BM, et al. CT of coronary artery disease. Radiology. 2004;232:18 37. 6. Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256 268. 7. Jakobs TF, Becker CR, Ohnesorge B, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol. 2002;12:1081 1086. 8. McCollough CH, Primak A, Saba O, et al. Hot topic: dose performance of a new 64-channel dual-source (DSCT) scanner. RSNA Annual Meeting. 2005:SSE16 06. 9. Ohnesorge B, Becker C, Flohr T, et al. Multislice CT in Cardiac Imaging: Technical Principles, Clincal Application and Future Developments. Berlin, Heidelberg, London, New York: Springer; 2002. 10. Siegel MJ, Schmidt B, Bradley D, et al. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology. 2004;233:515 522. 11. Fleischmann D, Hittmair K. Mathematical analysis of arterial enhancement and optimization of bolus geometry for CT angiography using the discrete fourier transform. J Comput Assist Tomogr. 1999;23:474 484. 12. Bae KT, Tran HQ, Heiken JP. Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: pharmacokinetic analysis and experimental porcine model. Radiology. 2000;216:872 880. 13. Hofmann LK, Zou KH, Costello P, et al. Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression. Radiology. 2004;233:927 933. 14. Flohr TG, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image-reconstruction techniques. Radiology. 2005;235: 756 773. 15. Vogl T, Abolmaali N, Diebold T, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology. 2002;223:212 220. 16. Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003;107: 664 666. 17. MacMahon H, Austin JH, Gamsu G, et al. Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology. 2005;237: 395 400. 34 r 2007 Lippincott Williams & Wilkins