Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Similar documents
Advanced in vitro exposure systems

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Cigarette Smoke Generator

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE

FEATURES AND PERFORMANCE OF THE HPP SMOKING MACHINE. Dritan Xhillari

CORESTA RECOMMENDED METHOD N 25

CyBio Felix Your Automated Application Starts Here

CORESTA RECOMMENDED METHOD N 22

CAD/CAM TECHNOLOGY. DC7 Milling System

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Regulatory Support for Tobacco Products. Feeling daunted by the regulatory process for tobacco products? Don t worry Battelle can help.

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Sleep diagnostics systems

HI Total Acidity Mini Titrator for Water Analysis

Description. Modell-Nr Airless ProfessionalLine. According to ISO 1167 ASTM D 1598 ASTM D Simple and safe operation. Reliable test results

CORESTA RECOMMENDED METHOD NÄ 9

ÜBERCLEAN! Introducing the new STATMATIC PLUS.

Cigarette Smoking Machine CSM-SCSM. User s Manual

RLS /M MX SERIES

ASSEMBLY AUTOMATION FOR PERFECT CANNUL A BONDING

Tel. : / Fax :

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

Simple. Stress-free. The Newtron Ultrasonics Series

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

A NEW, ADVANCED HIGH- THROUGHPUT SYSTEM FOR AUTOMATED INHALER TESTING

THS74/75 Industrial Temperature & Humidity Transmitter. Operation Manual

Effective Treatment for Obstructive Sleep Apnoea

V2 NOTEBOOK-CIG AND/OR V2 POWER-CIG

cigarettedesigner 4.0

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

INTERNATIONAL STANDARD

The Chemical characterisation of E-device Aerosols

Xstress 3000 G3/G3R. X-ray Stress Analyzer. Portable X-ray diffractometer specially designed for residual stress and retained austenite measurements

The Comprehensive Treatment Management System

THYROID UPTAKE SYSTEMS

Solutions at GE Inspection Technologies

HI Total Alkalinity Mini Titrator for Water Analysis

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Filament Fusion Splicing Workstation

VMA Demo Unit. Introduction. This document provides information on how to set up and operate the VMA Demo Unit. Figure 1: VMA Demo Unit

HI Total Alkalinity Mini Titrator for Water Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Isn t it worth two bags?

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

LMT-Goniophotometer GO-H 1400 Goniophotometer System for Measurement of Automotive Lamps

Case Study. Complex Components Demand Innovative Ultrasound Solution

Dynamic Hollow Cylinder System Proposal

Cleveland Clinic Home Monitoring Pilot

Controlling noise from compressed air systems

INTRAORAL IMAGING ACCORDING TO YOUR NEEDS Intraoral X-rays

ERS 2 CARDIAC REHABILITATION M O V I N G T O H E A L T H

AMS 200. Goniophotometer for small to medium-sized lamps and modules

mardtb Goniostat for X-ray crystallography

CORESTA Recommended Method No. 78

ASCO Power Control Systems Overview

autosamplers ASI-100 and ASI-100T Autosamplers

RLS /M MX SERIES

Granulation SyStEmS For waxes & oleochemicals

Volumetric Infusion Pumps - Delivering Volume with Accuracy

DÜRR X-RAY FILM PROCESSING. The development goes on and on DÜRR XR 24 PRO

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

Dialysis System DBB-07

Suffolk Wide - Various locations (Ipswich, Bury St. Edmunds and Waveney) regular travel across Suffolk will be required

How to Use the myhearing App on Apple/iOS devices

Solutions for Language Services in Healthcare

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

SAFETY DATA SHEET Dry Apple Ade (WM)

Effective Treatment for Obstructive Sleep Apnoea

Ultrasound & Laser Therapy

Sanako Lab 100 STS USER GUIDE

Head to new heights with your imaging SCANORA 3D

AK 200 S AK 200 ULTRA S. A better way to better care

Company Products Automation Service References. 1 Copyright SCHNUTZ GmbH

Commercial Ave., Northbrook, IL phone: (844)

COIL PROCESSING SOLUTIONS

Boehringer Ingelheim BioXcellence. Producing Value. Global Contract Manufacturing Excellence

ESWL Based on Experience + Innovation

CORESTA RECOMMENDED METHOD N 8

Evolve 3 & 5 Service Manual

Cortex Gateway 2.0. Administrator Guide. September Document Version C

Product Portfolio Medical Training Devices

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Veterinary Infusion Solutions

Reliable, flexible & precise

NC DOUBLE OPPOSING HEAD DRILL

Volumetric Infusion Pumps INFUSIONMANAGEMENT

2YEARS. three-phase kVA. Digital voltage stabiliser Orion Plus. Standard features. Voltage stabilisation PC selectable output voltage

POINT OF CARE DIAGNOSTICS

High Grade Universal Testing Machines

MilkoScan FT1. Milk standardisation with in-built abnormality screening. Dedicated Analytical Solutions

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

Transcription:

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Options for e-cigarettes VITROCELL VC 1 SMOKING MACHINE Manual smoking machine with high tech features square puff profiles higher puff volumes button actuator Objective The manual smoking machine VC 1 is specifically designed and manufactured to fulfill the requirements of in vitro experiments. Suitable for conventional and electronic cigarettes. Optimal when researching side- and mainstream smoke, it offers significant advantages over other commercial smoking machines. Generation of smoke with the shortest distance to cell cultures For the success of an experiment with mainstream tobacco smoke it is vital that the distance between the smoke generation (cigarette holders) and the VITROCELL cell exposure system is as short as possible to avoid aging and to guarantee authentic smokecomposition. Open and flexible system / incorporation of other analytical tools The VC 1 machine is designed to allow easy access to all tubes, filters and the pumping system. Additional analytical equipment relevant to the experiment can be easily and individually installed. Freely programmable parameters The computer system facilitates highly flexible programming of the smoking process. All parameters of the smoking process like puff duration, puff volume, puff frequency and exhaust duration can be defined according to experiment requirements. High flexibility for all smoking regimes ISO, Health Canada Intense, Massachusetts, Square and Human Puff Profile regimes (option) can be smoked. An upgrade for Shisha smoking is available.

Exposure Systems Dose Supply Dilution Racks & Carts Dose Monitoring Skin Exposure Auxiliary Equipment Statistics Smoking process data are logged into an Excel sheet for further processing. Machine dimensions are suitable for constrained lab workplaces The VC 1 machine is divided into 2 major components: computer, control box with smoking platform. All components are easy to clean In particular the work with unfiltered mainstream smoke demands frequent cleaning of all machine parts which come into contact with smoke. Cleaning must take place after each experiment to avoid any residual product contamination with subsequent experiments. Easy access to all component parts ensures quick and efficient cleaning. Components Top View Human puff profile capability This optional feature offers the possibility to upload human puff- profile data registered by Smoking Puff Analyzers to the machine controls. Compatibility with existing lab systems The VC 1 machine can be integrated with and connected to other lab systems, e.g. analytical systems. Compliance with ISO 3308 The VC 1 machine meets the requirements of ISO 3308, which assures compatibility with data generated for quality assurance purposes on other smoking machines. Compliance with Health Canada / CRM 81 Conditions The VC 1 machine meets the requirements of 55 ml/30 sec puff frequency for smoking combustion as well as electronic cigarettes. Quality The VC 1 machine is built to the highest standards using reliable and durable components. Precision of the process is ensured by a linear motor drive for the piston. Service All VC 1 machines are specifically designed to be exceptionally servicefriendly and have a secure internetbased remote servicing module. Software Control Input is communicated via PC with flat screen monitor or laptop (part of delivery). Scalability Pooling to multiple machines possible. 13 1 2 12 11 10 9 8 7 6 3 4 5 1 Main Switch and Power Supply 2 Compressed Air Connector 3 Piston Pump Unit 4 Smoke Exhaust 5 Manometer 6 System Off Button 7 System On Button 8 Emergency Stop 9 Smoking Start Button 10 Butt Length Sensor 11 Cigarette Holder 12 Smoke Extraction Fan 13 Exhaust Tube

State of the art controls for highest precision Software & Controls The operation is controlled by Beckhoff software in conjunction with Microsoft Windows 10. This setup offers extensive possibilities for integration with common Microsoft Office applications and the exchange of data with Excel -sheets. Smoking parameters The following parameters can be adjusted according to the needs of the experiment: Puff and exhaust duration Puff frequency Puff volume Puff profile Flow rate Clearing puff number Puff duration hold time Butt length via sensor Technical Data Dimensions: 605 x 455 x 533 mm (L x W x H) Voltage: Compressed air: Remote service module: 1 x 208-240 V, 50/60 Hz, 4 A 4 bar (58 psi) min. Included / Internet access mandatory

Human Puff Profiles For Smoking Machine VC 1 / VC 1 S-TYPE and Smoking Robots VC 10 / VC 10 S-TYPE Direct Reading from Puff Analyzer Data Files Human puff profile capability This optional feature for the VC 1 and VC 1 S-TYPE smoking machine, VC 10 and VC 10 S-TYPE smoking robots offers the possibility to feed data of human puff profiles registered by Smoking Puff Analyzers to the machine controls. Puff time precision of replication * Inter puff time precision of replication * Puff volume precision of replication * Flow versus time precision of replication * * ) Data from smoker compared with 2 channels of VC 10 smoking robot (VC 1 is using same technology).

COMPARISON VITROCELL SMOKING MACHINES # Criteria Smoking Machine VC 1 Smoking Machine VC 1 S-TYPE Smoking Machine VC 1/7 and VC 1/8 Smoking Robot VC 10 Smoking Robot VC 10 S-TYPE 1 Smoking Ports 1 Up to 5 Up to 8 10 10 2 Loading Manual Manual Manual Automatic/Option: Manual Automatic/Option: Manual 3 Lighting Manual Manual Manual Automatic by plate Automatic by hot air 4 Butt Extraction Manual Manual Manual Automatic Automatic 5 Butt Lenth Sensor Yes Yes Yes Yes Yes 6 Cylinder Volume 200 ml 200 ml 200 ml 50 ml 100 ml Option 1 300 ml - - 100 ml 200 ml Option 2 600 ml - - 200 ml - 7 Puff Exhaust Exits 1 Up to 3 7 and 8 1 5 Option 1 - - - 2 10 Option 2 - - - 4 15 Option 3 - - - 5-8 Cambridge Filter for Gas Phase Yes Yes Yes Yes Yes 9 Puff Profile ISO/Bell/Square Shaped ISO/Bell/Square Shaped ISO/Bell/Square Shaped ISO/Bell/Square Shaped ISO/Bell/Square Shaped Human Puff Profiles Option Option Option Option Option 10 Smoke Recipe Storage Yes Yes Yes Yes Yes 11 Purging after last puff Option Option Option Option Option 12 Chemcontrol - - - Option - 13 Puffs parameter logging Yes Yes Yes Yes Yes 14 Platform concept - - - - Yes 15 Docking stations - - - - Yes 16 Size cigarette magazine - - - 20/50 300 17 Holders for e-cigarettes Yes Yes Yes Yes Yes 18 Button actuator option for 1 / 7 e-cigerettes for 5 e-cigarettes for 7 or 8 e-cigarettes for 1 e-cigarette for 10 e-cigarettes 19 Heated smoke path - Option Option - Yes 20 Max. syringe drives 1 / 7 1 1 1 3 21 Cleaning procedure very easy very easy very easy easy very easy

About VITROCELL VITROCELL exclusively concentrates on the developing, producing, installing, training and servicing of advanced in vitro exposure systems. The VITROCELL Systems team is driven by their vision for new in-vitro standards through state-of-the-art technology, highly qualified workmanship and absolute client dedication. VITROCELL has successfully collaborated with clients from leading research institutes, contract research organizations, regulatory authorities or industrial laboratories across the world. Working with our team experts, all modules have been tailored to create durable and complete turnkey-systems for in vitro inhalation toxicology. Gases, environmental atmospheres, nano particles and complex mixtures are analyzed on lung cells at the air/liquid interface using these systems. VITROCELL technologies are also applicable to solutions for skin research. Over a decade of devotion to research in this specific field has given our team of design & precision manufacturing specialists the opportunity to mentor highly diversified and complex projects from conception to completion. We strive to become a constructive member of each research team, providing support when it is needed, advice when it is required and modules of the highest quality, which are even polished by hand before leaving here to be integrated into your workspace. Every piece of our German engineered equipment is manufactured to the highest of standards yours. VITROCELL Systems GmbH Fabrik Sonntag 3 79183 Waldkirch Germany Tel. +49 7681 497 79-50 Fax +49 7681 497 79-79 Email: info@vitrocell.com www.vitrocell.com