High-performance Liquid Chromatographic Determination of Urinary Trans, Trans-Muconic Acid Excreted by Workers Occupationally Exposed to Benzene

Similar documents
Determination and pharmacokinetics of manidipine in human plasma by HPLC/ESIMS

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Biomarker Concentration Acting as the Indicators for Chemicals Health Risk Assessment The Case Study in Thailand

Title Revision n date

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of propranolol in dog plasma by HPLC method

Bioequivalence Studies of Two Formulations of Famciclovir Tablets by HPLC Method

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

HPLC method for Pharmacokinetics of cis and trans isomer of cefprozil diastereomers in human plasma

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Screening of Antihistamine Agents (Diphenhydramine) with Blood and Urine Samples by REMEDi-HS System

Sheikh R J et al. IRJP 1 (1)

A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ASSAY FOR LERCANIDIPINE HYDROCHLORIDE

HPLC-UV Determination of Abacavir Sulphate in Pharmaceutical Dosage Forms

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

SIMPLE AND VALIDATED RP-HPLC METHOD FOR THE ESTIMATION OF CARBOPLATIN IN BULK AND FORMULATION DOSAGE FORM. Subhashini.Edla* B.

RP- HPLC and Visible Spectrophotometric methods for the Estimation of Meropenem in Pure and Pharmaceutical Formulations

Lutein Esters from Tagetes Erecta

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS

SIMULTANEOUS DETERMINATION OF ATORVASTATIN AND EZETIMIBE BY RP-HPLC IN PURE AND PHARMACEUTICAL DOSAGE FORM

Determination of Bath Salts (Pyrovalerone Analogs) in Biological Samples

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Simultaneous determination of triacetin, acetic ether, butyl acetate and amorolfine hydrochloride in amorolfine liniment by HPLC

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

CHAPTER 3: ANALYTICAL METHOD DEVELOPMENT AND VALIDATION

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Development and Validation of HPLC-UV Method for Simultaneous Determination of Nevirapine, 2-OH Nevirapine and 3-OH Nevirapine in Human Plasma.

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

SUPPLEMENTARY MATERIAL

This revision also necessitates a change in the table numbering in the test for Organic Impurities.

Scholars Research Library

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

Tenofovir disoproxil fumarate (Tenofoviri disoproxili fumaras)

Analysis of Phenolic Antioxidants in Edible Oil/Shortening Using the PerkinElmer Altus UPLC System with PDA Detection

DEVELOPMENT, VALIDATION AND APPLICATION OF THE HPLC METHOD FOR DETERMINATION OF MIANSERIN IN HUMAN SERUM

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

ASSAY AND IMPURITY METHOD FOR DURACOR TABLETS BY HPLC

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Available online Research Article

Development of a Validated RP-HPLC Method for the Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Significant Positive Correlation of Plasma BPDE-Albumin Adducts to Urinary 1-Hydroxypyrene in Coke Oven Workers 1

Pelagia Research Library

Development, Optimization and Validation of HPLC Method for Determination of Pravastatin Sodium in Tablets

Fig.1. Denatonium benzoate (DB) chemical structure

AN HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF RISPERIDONE AND TRIHEXYPHENIDYL HYDROCHLORIDE FROM BULK AND DOSAGE FORMS.

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Research and Reviews: Journal of Pharmaceutical Analysis

CORESTA Recommended Method No. 78

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

DETERMINATION OF OXYCODONE CONTENT AND RELATED SUBSTANCES IN OXYCODONE AND ACETAMINOPHEN CAPSULE BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

Journal of Chemical and Pharmaceutical Research

Necessity of Monitoring HPLC by a X-R Control Chart on Measurement of Serum Fat-Soluble Vitamins

Analysis of HMF by HPLC

Application Note. Author. Abstract. Introduction. Food Safety

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

World Journal of Pharmaceutical Research

Flupyradifurone. HPLC Method

National Standard of the People s Republic of China. National food safety standard. Determination of pantothenic acid in foods for infants and

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

International Journal of Pharma and Bio Sciences

Quetiapine Tablets. Expert Committee Monographs Chemical Medicines 4 Reason for Revision Compliance

A high-performance liquid chromatography (HPLC) method for determination of chlorogenic acid and emodin in Yinhuang Jiangzhi Tea

DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

A Sensitive and Simple High Performance Liquid Chromatographic Method for Quantification of Tadalafil in Human Serum

Corresponding Author:

Transcription:

BIOMEDICAL AND ENVIRONMENTAL SCIENCES 19, 292-296 (2006) High-performance Liquid Chromatographic Determination of Urinary Trans, Trans-Muconic Acid Excreted by Workers Occupationally Exposed to Benzene XIA-MIN HU *,1, SHI-ZHEN SONG #, FANG-LI YE #, AND LI-WEN LIU # * Departments of Pharmacology, # Occupational Health, Medical College of Wuhan University of Science and Technology, Wuhan 430080, Hubei, China Objective To investigate the relationship between trans, trans-muconic acid (ttma) as benzene metabolite of occupational workers and benzene concentration in air. Methods A rapid and sensitive high-performance liquid chromatography was developed to determine the level of urinary ttma. ttma was extrated from urinary samples in liquid-liquid phase a ODS (2) (5u) column (Φ4.6 mm 150 mm) and detected at wavelength 264 nm in a UV detector using vanillic acid as an internal standard. The mobile phase was acetaticacid/tetrahydrofuran/methanol/water (v/v, 1:2:10:87). The method was validated with 56 urine samples collected from occupationally benzene-exposed individuals. Results A correlation coefficient (r = 0.9963 ) was found for ttma ranging 0.10-10.00 μg/ml. The limit of detection was 0.10 µg/ml. The recovery and reproducibility were generally over 90%. There was a positive correlation between ttma and benzene level in air. The equation was Y=0.859+0.108C (before work, r=0.6200) or Y=1.980+0.179C (after work, r=0.7930). Conclusion This method can be used to determine and control the level of urinary ttma in those who are occupationally exposed to benzene. Key words: Benzene; Trans; Trans-muconic acid; High-performance liquid chromatography INTRODUCTION Benzene exists ubiquitously as an environmental contaminant to which the general population are exposed, due to its occurrence in mineral oil and formation in many combustion processes [1]. It is mutagenic and carcinogenic in animal models and interrelates to bone marrow toxicity and leukemia [2-4]. The risk of developing leukaemia has been estimated in approximately six cases per million people who experience lifelong exposure to benzene concentrations of 1 μg/m 3 in air [5]. So monitoring and control of benzene exposure are of great importance [6-8]. The main route for the uptake of benzene at workplace and from environment is via inhalation. Benzene is primarily metabolized in the liver to a series of ring-hydroxylated and conjugated metabolites as well as ring-opened products, which are excreted in urine [9]. Benzene is metabolized in vivo by transforming to phenol, hydroquinone, and catechol [10-11]. These metabolites are mainly excreted in urine after conjugation with glucuronide and sulphate or undergo further metabolism to 1,4-benzoquinone and 1,2,4-trihydroxybenzene. Benzene is also transformed to trans, trans-muconic acid (1, 3-butadiene-1, 4-dicarboxylic acid, ttma) after the ring-opened oxidation process. Among these benzene metabolic products, ttma, a short-chain dicarboxy acid as a main metabolite of benzene ring cleavage, has been used as a potential biomarker for benzene exposure. ttma as a marker is also determined by gas chromatography-mass spectrometry (GC-MS) [12] and liquid chromatography-mass spectrometry (LC-MS) [13]. Although these methods are highly sensitive, they are not suitable for the routine analysis in industry. The aim of this study was to develop a simple, rapid, sensitive HPLC method for evaluating the level of urinary ttma excreted by workers occupationally exposed to benzene. Drugs and Reagents MATERIALS AND METHODS ttma and vanillic acid (internal standard, IS) 1 Correspondence should be addressed to Xia-Min HU, Tel: 86-27-68862040. Fax: 86-27-68862154. E-mail: huxiaming@163.com Biographical note of the first author: Xia-Min HU, born in 1965, female, associate professor, majoring in pharmacokinetics and toxicology. 292 0895-3988/2006 CN 11-2816/Q Copyright 2006 by China CDC

HPLC DETERMINATION OF ttma IN WORKERS URINARY 293 were purchased from Sigma (St. Louis. Mo. USA). Methanol, acetic acid and tetrahydrofuran were of HPLC grade. Ten mg of ttma were dissolved in 8 ml of methanol and then deionzed water was added to 10 ml of ttma solution (1 mg/ml). One ml of ttma solution (1 mg/ml) was poured in a volumetric flask, and then dilute hydrochloric acid 1/10(v/v) was added to make 10 ml ttma solution (100 μg/ml). The stock solution was obtained by diluting 5 times the above solution with deionzed water. Vanillic acid stock solution (IS solution, 100 μg/ml) was prepared by the same method. These solutions were stored at 4. Apparatus and Conditions A Hitachi SPD 6A HPLC system consisting of L-6000 pumps, Nanjing Qianpu system controller, SPD6A ultraviolet spectrophotometer detector, ODS(2)(5u) column (Φ4.6mm 150mm) (Dalian Yilite) was used in this study. The data were analyzed by Sigma Plot 2000 Microsoft Excel98 software (USA). The mobile phase components were acetate-acid/ tetrahydrofuran/methanol/water (v/v, 1/2/10/87). Ultraviolet wavelength was 264 nm. The flow-rate was 0.9 ml/min. Study Design Workers in iron and steel factory in China occupationally exposed to benzene and other aromatic solvents were enrolled in this study. Controls were selected from those not exposed to benzene and matched by age and sex. The amount of benzene inhaled by the workers for a full work shift was collected with passive dosimeters (TMP 1500) and determined by gas chromatography (Asilent G1540A). The urinary samples were obtained from each volunteer twice a day, at 8:00 AM (second urination, work shift beginning) and at 16:00 PM. Twenty to 50 ml of urine were collected and 3 ml samples were stored at -18 until analysis. The level of urine creatinine was determined by the WS/T 97-1996 method. Extraction Procedures In brief, 0.5 ml of urine sample, 50 μl of IS (vanillic acid solution, 100 μg/ml) and 100 μl of 2 mmol/l HCl were mixed in a 10 ml tube for 10 s. Then 4 ml of ethyl acetate was added and the tube was vortex-mixed for 20 min followed by centrifugation at 2500 rpm for 15 min. Five ml of organic layer were transferred to another tube and evaporated to dryness below 40 under a gentle stream of nitrogen. The residue was dissolved in 500 µl of mobile phase and mixed for 30 s, 10 μl of the above solution were injected into the HPLC system for analysis. Preparation of Calibration Curve The working solutions at concentrations of 0.10, 0.50, 1.00, 2.50, 5.00, and 10.00 µg/ml were obtained by further diluting the working stock solution with blank urine, and then 100 μl of 0.05 mol/l HCl were added to the above solutions. The solution of vanillic acid at the concentration of 100 μg/ml was prepared as internal standard. These solutions were used to prepare the calibration curves and for quality control. Determination was carried out based on internal standardization. The calibration curves were drawn by plotting peak area ratio (Y) of the analyte to the internal standard against the concentration (C) of the analyte. Sample Analyses ttma was extracted from urinary samples collected from 56 workers exposed to benzene and 24 volunteers not exposed to benzene and was determined according to the above method. RESULTS Chromatographic Separation The chromatogram of determined ttma is shown in Fig. 1. ttma and the internal standard were completely with the rention time of 5.5 min and 13.5 min. There was no interference of impurities. All results showed that the method was specific for determination of ttma in urine. Calibration, Recovery, and Reproducibility The calibration curve of ttma was in good linearity over the concentration range of 0.10-10.00 μg/ml, and the coefficient of correlation was 0.9963. The calibration equation was Y=0.014+0.271C (Y, peak areas of samples -peak areas of blank urine/peak areas of IS; C, concentrations of ttma). The limit of detection was 0.10 µg/ml, and the recovery and reproducibility were generally over 90%. The intra-day and inter-day coefficients of variation were below 10% (Table 1). Stability of ttma in Urine ttma was stable in urine for at least 4 months when stored at -18 without any chemical preservative, while the same samples stored at room temperature were stable for a week.

294 HU ET AL. TABLE 1 Recovery and Precision Studies of Urine Samples for ttma in Urine Concentration Precision Recovery ( x ± s, %) (μg/ml) Intra-day Inter-day Extraction Relative 0.5 2.5 5 8.3 4.9 6.0 9.0 6.4 6.7 Urinary Concentrations of ttma 86.8±5.1 87.7±6.6 86.1±4.6 104.6±0.1 95.1±4.0 96.5±4.5 On the basis of the developed method, the urinary excretion of ttma in 56 workers occupationally exposed to benzene was determined. The values of ttma /creatinine in urine before or after work and the correlation of ttma /creatinine-benzene level exposed in air are shown in Table 2 and Fig. 2. In the present study, the 56 workers occupationally exposed to benzene were divided into three groups according to their benene-exposure levels: <20 mg/m 3 (n=21), >20-60 mg/m 3 (n=18), and >60 mg/m 3 (n=17). The urinary ttma /creatinine under different levels of benzene-exposure are shown in Table 2 and Fig. 2. In the mean time, the results illustrated that there was a positive correlation between ttma and benzene exposure level in air, and the equations were Y=0.859 + 0.108C (before work, r=0.6200) and Y=1.980+0.179C (after work, r=0.7930) (Fig. 2). TABLE 2 Urinary ttma Levels in Volunteers Under Different Benzene Levels Level of Benzene (mg/m 3 ) <20 20-60 >60 Workers (n) 21 18 17 ttma Level (mg/g Creatinine) ( x ± s ) Before Work 1.23±1.17 4.85±3.40 11.21±7.02 After Work 2.78±3.13 10.03±4.59 17.28±6.74 Note. Level of benzene: the amount of benzene from the environment via inhalation. The urinary samples were collected from each volunteer twice a day, at 8:00 AM (second urination, work shift beginning) and 8 h later. The levels of urinary ttma were determined by the above HPLC method. FIG. 1. HPLC of determined ttma (ttma:5.4 min; I.S:13.5 min). A, blank urine; B, standard sample of ttma in blank urine; C, urinary sample of volunteer.

HPLC DETERMINATION OF ttma IN WORKERS URINARY 295 FIG. 2. Correlation between ttma and benzene level in air before (A) or after work (B) in 56 volunteers occupationally exposed to benzene. DISCUSSION Occupational exposure to benzene has been causally associated with the increasing risk of aplastic anaemia, myelodysplastic syndrome, and acute non-lymphocytic leukaemia. The method to estimate the biological limit for exposure to occupational or environmental benzene is important for many countries, especially for the developing countries. Excretion of urinary ttma has been widely recommended as a biomarker for estimation of occupational or non-occupational exposure to benzene. Although the analytical method of LC/MS or GC/MS can provide a better detection mode with high sensitivity, the expensive equipment and complicated techniques limit its application in routine analysis. In the present study, a rapid, sensitive and accurate method was developed, which can be used to monitor the biological limit value for occupational exposure to benzene. Fifty-six volunteers exposed to benzene and other aromatic solvents were included in this study. The results showed that ttma in urine was closely correlated with benzene in air (Y=0.859+ 0.108C, before work, r=0.6200) and (Y=1.980 + 0.179C, after work, r=0.7930). On the basis of above results, we draw the conclusion that in these workers the median excretion of ttma is 3.05 mg/g creatinine after work and 1.50 mg/g creatinine before work. These experiments provide a linear extrapolation between excretion of ttma and benzene level, which can determine the excretion of ttma according to the inhaled benzene concentration. In summary, our method can be applied to the determination of ttma in urine in workers occupationally exposed to benzene. ACKNOWLEDGEMENTS We thank Professor De-Long YANG in Tongji Medical College of Huazhong University of Science and Technology for his interest in this study. REFERENCES 1. Hecht S S (2002). Human urinary carcinogen metabolites: biomarkers for investigating tobacco and cancer. Carcinogenesis 23, 907. 2. Scherer G T, Renner M M (1998). Analysis and evaluation of trans, trans-muconic acid as a biomarker for benzene exposure. J Chromatogr B Biomed Sci Appl 717, 179. 3. Lee B L, New A L, Kok, P W, et al. (1993). Urinary trans, trans-muconic acid determined by liquid chromatography: application in biological monitoring of benzene exposure. Clin Chem 39, 1788. 4. Yin S N, Hayes R B, Linet M S, et al. (1996). An expanded cohort study of cancer among benzene-exposed workers in China. Benzene Study Group. Environ Health Perspect 104, 1339-1341. 5. Working Group (1996). Updating and Revision of the Air Quality Guidelines for Europe; Report on the WHO Working Group on Volatile Organic Compounds. EUR/ICP/EHAZ 94 05/MT12. 6. Inoue O, Seiji K, Nakatsuka H, et al. (1989). Urinary t,t-muconic acid as an indicator of exposure to benzene. Br J Ind Med 46, 122. 7. Choon-Nam, O, Bee-Lan L. Determination of benzene and its metabolites: Application in biological monitoring of environmental and occupational exposure to benzene. J Chromatogr B 660, 1. 8. Rauscher D, Scherer G K H, Schaller J (1993). Angerer. t,t-muconic acid as a biomarker for an occupationally and environmentally caused benzene exposure; Poster presented at The 24th International Congress on Occupational Health, September 9-October 1, Nice. 9. Gobba F, Rovesti S, Borella P, et al. (1997). Inter-individual variability of benzene metabolism to trans, trans-muconic acid and its implications in the biological monitoring of occupational exposure. Science of the Total Environment 199, 41-48. 10. Daniel Goon, James Matsuura, David Ross (1993). Metabolism and cytotoxicity of trans,trans-muconaldehyde and its derivatives: Potential markers of benzene ring cleavage reactions. Chemico-Biological Interaction 88, 37-53. 11. T Valente L, Medico D (2002). Chiapperini and A.D. Bonsignore. Determination of urinary t-t muconic acid as biomarker of environmental benzene intake and its interference factors. Ann Chim 92, 911. 12. Thomas Renner, Michaela Baer-Koetzle, Gerhard Scherer

296 HU ET AL. (1999). Determination of sorbic acid in urine by gas chromatography-mass spectrometry. J of Chromatography A 847, 25(1-2), 127-133. 13. Gerhard Scherer, Thomas Renner, Michael Meger (1998). Analysis and evaluation of trans, trans-muconic acid as a biomarker for benzene exposure. Journal of Chromatography B: Biomedical Sciences and Applications 717(1-2), 179-199. (Received July 28, 2005 Accepted July 23, 2006)