Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system

Similar documents
Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

Early Results of Total Knee Replacements:

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

Analysis of factors affecting range of motion after Total Knee Arthroplasty

15-Year Follow-up Study of Total Knee Arthroplasty in Patients With Rheumatoid Arthritis

Investigation performed at the Department of Orthopedics, Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Total Knee Replacement: 12 Years Retrospective Review and Experience

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

Range of Motion of Standard and High-Flexion Posterior Stabilized Total Knee Prostheses A PROSPECTIVE, RANDOMIZED STUDY

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

Modularity in tibial components for total knee

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY

Total Knee Arthroplasty in a Patient with an Ankylosing Knee after Previous Patellectomy

Clinical Performance of the Optetrak Total Knee Prosthesis: A 11-year Follow-up Study

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

The Journal of Arthroplasty

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

Clinical Results of Genesis-I Total Knee Arthroplasty

A DISSERTATION SUBMITTED TO THE UNIVERSITY

The Egyptian Journal of Hospital Medicine (January 2019) Vol. 74 (7), Page

Both Knee Re-revision Operations with Different Types of Endoprosthesis after Septic Complications

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

Functional Outcome of Uni-Knee Arthroplasty in Asians with six-year Follow-up

ISSN X (Print) Original Research Article. *Corresponding author Dr Shaival Chauhan

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year

The Result of PFC (press-fit condylar) Total Knee Replacement Arthroplasty*

Durability of a Cruciate-retaining TKA With Modular Tibial Trays at 20 Years

Genu Recurvatum versus Fixed Flexion after Total Knee Arthroplasty

Unicondylar Knee Vs Total Knee Replacement: Is Less Better In the Middle Aged Athlete

Complications of Total Knee Arthroplasty

Title of the article: the epidemiology of revision knee arthroplasty at a tertiary care center in india.

Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F

H.P. Teng, Y.J. Chou, L.C. Lin, and C.Y. Wong Under general or spinal anesthesia, the knee was flexed gently. In the cases of limited ROM, gentle and

Original Article. Introduction. Materials and Methods

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

Kinematic vs. mechanical alignment: What is the difference?

Outcome After Isolated Polyethylene Tibial Insert Exchange in Revision Total Knee Arthroplasty

Full Function, Faster Medial-Pivot

Knee Revision. Portfolio

BIOMECHANICAL EVALUATION OF DEGREE OF FREEDOM OF MOVEMENTS OF AN NOVEL HIGH FLEXION KNEE FOR ITS SUITABILITY IN EASTERN LIFESTYLES

Total Knee Replacement

Clinical Results of Lateral Unicompartmental Knee Arthroplasty: Minimum 2-Year Follow-up

Clinical evaluation of 292 Genesis II posterior stabilized high-flexion total knee arthroplasty: range of motion and predictors

We reviewed the outcome of 422 primary

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

Fixed bearing versus high flexion RP total knee arthroplasty (TKA): midterm results of a randomized controlled trial

Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee Arthroplasty System at Implant Cement Interface

Condylar constrained system in primary total knee replacement: our experience and literature review

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

NexGen CR Total Knee Arthroplasty: Ten Year Clinical Results

Medium term results of the Miller-Galante unicompartmental knee arthroplasty with 10 year survivorship

Functional and radiological outcome of total knee replacement in varus deformity of the knee

Stefan Rahm MD University Hospital Balgrist

TOTAL KNEE ARTHROPLASTY (TKA)

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

The effect of leg alignment on the outcome of unicompartmental knee replacement

The St. Leger total knee replacement: a false economy Westwood M J, White S P, Bannister G C

Why precision is powerful

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Original Article Clinics in Orthopedic Surgery 2015;7:

Scandinavian Journal of Surgery 0: 1 8, Department of Surgery, North Karelia Central Hospital, Joensuu, Finland 2

Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplasty

Triathlon Tritanium Knee System

Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty

Case Report Total Knee Arthroplasty in a Patient with Bilateral Congenital Dislocation of the Patella Treated with a Different Method in Each Knee

The prosthetic implant of MBA Optetrak in the treatment of knee osteoarthritis: 5 years of experience

art h ro plasty Heterotopic ossification after total knee 54/61 5 cases after 1-6 years follow-up

The UniSpacer : correcting varus malalignment in medial gonarthrosis

1 Introduction. 2 Data and method

Dora Street, Hurstville 160 Belmore Road, Randwick

Biomechanics of. Knee Replacement. Mujda Hakime, Paul Malcolm

International Journal of Pharma and Bio Sciences ABSTRACT

Mædica - a Journal of Clinical Medicine

Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis

Hospital for Joint Diseases

Clinical Results of Bone Ingrowth TKA in Patients with Rheumatoid Arthritis

Unicompartmental or total knee replacement

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Short Term Clinical and Radiographic Results of the Salto Mobile Version Ankle Prosthesis

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty

Augmented Glenoid Component for Bone Deficiency in Shoulder Arthroplasty

Instrumentation Options

A Systematic Review on Performance of the Vanguard Complete Knee System

Ju-Yeong Kwak, MD, Jae-Heon Jeong, MD*, Sang-Hak Lee, MD, Ho-Joong Jung, MD, Young-Bok Jung, MD

Bilateral Total Knee Replacements using Two Different Implant Designs - Preliminary Report

Anterior knee pain following total knee replacement caused by isolated Paget's disease of patella

There have been conflicting results reported in the

Mid-Term Results of Oxford Medial Unicompartmental Knee Arthroplasty

Knee Replacement Implants

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

Knee Surg Relat Res 2011;23(3): pissn eissn Knee Surgery & Related Research

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY

Insert dissociation after fixed bearing PS constrained Genesis II total knee arthroplasty. A case series of nine patients

Coronal Instability after Total Knee Arthroplasty using Bi-Surface type 3 : An Averaged 10 Year Follow-up Study

Design modifications of high-flexion TKA do not improve short term clinical and radiographic outcomes

Validation of a French version of the Oxford knee questionnaire

Transcription:

Journal of Orthopaedic Surgery 2005:13(3):280-284 Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system S Asif, DSK Choon Department of Orthopaedic Surgery, University of Malaya Medical Centre, Kuala Lumpur, Malaysia ABSTRACT Purpose. To evaluate the midterm results of 50 patients who underwent total knee replacement using Press Fit Condylar (PFC) Sigma system. Methods. We retrospectively reviewed 87 consecutive cases (50 patients with 37 bilateral cases) of PFC Sigma total knee replacement performed between January 1998 and December 1999. Patients were evaluated clinically and radiographically by an independent observer. The Society Score, Oxford Knee Score, and Knee Society radiographic assessment were used to rate knee function and to determine the satisfaction level of each patient. Results. The mean age of the patients at the time of operation was 65 years (range, 41 85 years). The mean follow-up period was 5.4 years (range, 4.5 6.4 years). 44 patients (79 knees) were available for follow-up, 3 patients (3 knees) were lost to follow-up, and 3 patients (5 knees) died of unrelated causes. At the final follow-up, the mean Oxford Knee Score was 22. Using the Society Score, 88% of the knees were rated excellent, 4% good, 2% fair, and 6% poor. Five knees required revision surgery, the indications being infection in 4 knees and aseptic loosening in one knee. The survival rate of the implants was 94% at 6 years. Conclusion. The PFC Sigma total knee arthroplasty system has demonstrated good midterm results at our institution. Key words: arthroplasty, replacement, knee; knee prosthesis; prostheses and implants; prosthesis design INTRODUCTION Total knee replacement is becoming increasingly popular worldwide due to improvements in the Address correspondence and reprint requests to: Dr DSK Choon, Associate Professor, Department of Orthopaedic Surgery, University of Malaya Medical Centre, Lembah Pantai 59100, Kuala Lumpur, Malaysia. E-mail: dchoon@yahoo.com

Vol. 13 No. 3, December 2005 Midterm results of PFC Sigma total knee arthroplasty system 281 technology and durability of implants. In the United States, the number of knee replacements has surpassed the number of hip replacements. 1 The prevalence of arthritis, including osteoarthritis and rheumatoid arthritis, continues to increase with age for people 65 years or older. Clinical decisions for selecting one implant over another must be supported by clinical results. 2 The design of the Press Fit Condylar (PFC) Sigma (DePuy, Warsaw [IN], US) total knee arthroplasty (TKA) prosthesis was based on the earlier PFC implant. Design features include modularity to improve intra-operative adaptability, and a deep and extended trochlear groove with a matching single radius dome patella, allowing the patellar component to maintain maximum contact of up to and beyond 90 Ο of flexion. This implant was introduced to our institution in late 1997. This study evaluates the midterm clinical and radiological results of TKA using the PFC Sigma prostheses. The Oxford Knee Score 5 is a patient-based outcome assessment of patient response to surgery. It consists of 12 questions, each with 5 items. The highest score is 12 points and the lowest is 60. Patients are asked to complete a questionnaire about their symptoms with the assistance of a nurse. Radiographic evaluation Weight-bearing radiographs of the knees were analysed for loosening and evidence of failure according to the Knee Society radiographic assessment. 6 This assessment includes evaluation for radiolucent lines on anteroposterior and lateral radiographs, and of alignment of the prosthesis. A radiolucent line of greater than 2 mm around the entire circumference of the prosthesis, subsidence of the component, or a change in alignment from a previous radiograph signified a radiographically loose prosthesis. METHODS We retrospectively reviewed 87 TKAs performed by a number of surgeons in 50 patients (46 women and 4 men) using the PFC Sigma prostheses at the University of Malaya Medical Centre between January 1998 and December 1999. All cases used cemented fixation. Clinical evaluation Knees were stratified into 3 categories according to Halley and Charnley 3 : 36 in category A (unilateral or bilateral TKA), 8 in category B (one knee symptomatic but not replaced), and 6 in category C (multiple arthritis or medical infirmity). At follow-up, patients were evaluated clinically by an independent observer using the Society Score 4 and the Oxford Knee Score. 5 The Society scoring system 4 comprises a knee score and a functional score. Knees are examined for range of motion, flexion contractures, extension lag, alignment, and stability in the anteroposterior and mediolateral plane. The maximum score for each of the knee and functional scores is 100 points. The knee score includes pain (50 points), range of motion (25 points), and anteroposterior and mediolateral stability (25 points). Deductions are made for flexion contracture, extension lag, and alignment. The functional score includes walking (50 points) and stair climbing (50 points). Deductions are given for walking aids. Scores of 80 to 100 were rated as excellent, 70 to 79 good, 60 to 69 fair, and less than 60 poor. RESULTS Of the 50 patients (46 women and 4 men), 37 underwent simultaneous bilateral TKA. The mean age of the patients at the time of index operation was 65 years (range, 41 85 years). The indications for surgery were osteoarthritis in 44 patients and rheumatoid arthritis in 6 patients. 44 patients (79 knees) were able to return for clinical evaluation. Three patients (5 knees) died of unrelated causes and 3 patients (3 knees) were lost to follow-up. The mean follow-up period was 5.4 years (range, 4.5 6.4 years). The posterior cruciate ligament (PCL) retaining implant was used in 53 knees, while the PCLsubstituting implant was used in 26 knees. The patella was resurfaced in 34 knees and was not resurfaced in 45 knees. The implant survival rate was 94% at 6 years. Clinical results At the final clinical assessment, using the American Knee Society scoring system, the mean knee score was 87 points (range, 48 99; standard deviation [SD], 11.06). The mean functional score was 72 points (range, 0 100; SD, 20.27); 88% of knees were rated excellent, 4% good, 2% fair, and 6% poor. Five knees in 3 patients were rated poor. Two of these patients had undergone bilateral TKA for rheumatoid arthritis, and both were homebound because of multiple joint problems and medical illness. The third patient had a functioning unilateral knee but remained homebound because

282 S Asif and DSK Choon Journal of Orthopaedic Surgery Table 1 Oxford Knee Score Oxford Knee Score No. of patients, n=44 12 17 10 (766.) 18 23 23 (766.) 24 29 26 (766.) 30 35 22 (766.) 36 41 21 (766.) 42 47 22 (766.) Table 2 Comparison between patients with osteoarthritis and rheumatoid arthritis* Osteoarthritis Rheumatoid p value arthritis 0Knee score 88 (10) 79 (14) 0.100 0Functional score 73 (19) 57 (25) 0.030 Oxford Knee Score 21 (6)0 30 (10) 0.006 Table 3 Comparison between patients with and without resurfaced patella* Resurfaced patella p value No Yes 0Knee score 88 (9)0 85 (13) 0.26 0Functional score 72 (16) 71 (25) 0.76 Oxford Knee Score 22 (7)0 22 (7)0 0.90 Table 4 Comparison between posterior cruciate ligament retaining and substituting implants* PCL PCL p value retaining substituting 0Knee score 88 (9)1 85 (14) 0.43 0Functional score 75 (17) 66 (24) 0.38 Oxford Knee Score 21 (6)1 24 (8)1 0.21 of severe spinal stenosis. The mean Oxford Knee Score was 22 (range, 16 46; SD, 6.76) [Table 1]. We compared the Society knee and functional scores and the Oxford score between patients diagnosed with osteoarthritis and rheumatoid arthritis using the Student s t test. No significant difference was found between the 2 groups on knee score (p=0.10) or functional score (p=0.03); the only statistically significant difference was found with the Oxford Knee Score (p=0.006) [Table 2]. When comparing patients who underwent resurfacing of the patella with those who did not, no significant difference was found between the 2 groups on knee score (p=0.26), functional score (p=0.76), or Oxford Knee Score (p=0.90) [Table 3]. When comparing patients who received PCL-retaining implants with those who received PCL-substituting implants, again, no significant difference was found between the 2 groups on knee score (p=0.43), functional score (p=0.38), or the Oxford Knee Scores (p=0.21) [Table 4]. At the most recent follow-up, relief of pain was excellent in most patients: 82% had no pain or very mild pain, 13% had pain while climbing stairs, and 5% had moderate pain; 59% could walk farther than 10 blocks or more than one hour, and 91% did not use assistive devices for ambulation. At final clinical assessment, the mean active flexion was 105 Ο (range, 20 Ο 130 Ο ). The mean flexion contracture was 0.6 Ο (range, 0 Ο 15 Ο ). 21 knees had more than 5 Ο of mediolateral instability, and only one knee had more than 10 mm of anteroposterior instability. Radiographic results The tibiofemoral angle was 5 Ο to 8 Ο valgus in 64 knees, 0 Ο to 4 Ο valgus in 8 knees, and 0 Ο to 8 Ο varus in 7 knees. The mean femoral component alignment from the anteroposterior view was 96 Ο (range, 94 Ο 99 Ο ; SD, 0.97 Ο ), and the mean tibial component alignment from the anteroposterior view was 90 Ο (range, 87 Ο 95 Ο ; SD, 2.19 Ο ). The mean posterior slope of the tibia was 1.03 Ο (range, 0 Ο 7 Ο ; SD, 1.75 Ο ). No knees were found to have aseptic loosening of the tibial, femoral, or patellar components by American Knee Society criteria at final follow-up. Radiolucent lines of 1-mm thick were present around zones 1 and 2 in 6 tibial components, and around zone 1 in 4 femoral components.

Vol. 13 No. 3, December 2005 Midterm results of PFC Sigma total knee arthroplasty system 283 Revision operations Five knees (4 patients) required revision surgery: 4 knees (3 patients) because of deep infection and one knee due to aseptic loosening of the tibial component. Of patients with deep infection, one presented with swelling and erythema around the knee at postoperative 2 months. A 2-stage revision was performed after 6 months. At the final follow-up, the patient s knee and functional scores were 76 and 60 points, respectively. The second patient presented with a history of pain in both knees for more than one year and was scheduled for simultaneous bilateral TKA. During the surgery, slough was found in the left knee. The knee surgery was aborted and tissue was sent for culture and histopathology. The cultures were negative, and the histopathology report indicated chronic inflammatory disease. The operation was resumed 4 weeks later. One week postoperatively, the patient developed fever and had discharge from the left knee. An arthrotomy and washout was performed, and tissue was taken for culture. The cultures grew methicillin-resistant Staphylococcus aureus (MRSA). The patient was given intravenous vancomycin for 6 weeks, and was then discharged and received oral fusidic acid and rifampicin for 3 months. After 2 years, the patient presented with pain in the left knee, this time with loosening of the implant. A one-stage revision was carried out after infection was ruled out by intra-operative frozen section and gram stain. At final follow-up, the patient s knee and functional scores were 78 and 60 points, respectively. The third patient also underwent simultaneous bilateral TKA, and presented at postoperative one month with a discharging sinus on the left knee; aspirate cultures grew MRSA. A 2- stage revision was performed. The patient presented again 2 years later with swelling of the right knee; aspirate culture grew MRSA. A 2-stage revision was subsequently performed on the right side as well. At final follow-up, this patient s knee score was 87 for the left side and 89 for the right side, and his functional score was 90. One patient with rheumatoid arthritis required revision of the tibial component after 2 years because of aseptic loosening; the tibial component had been inserted in 8 Ο of varus at the primary surgery. At final follow-up, the patient s knee and functional scores were 69 and 55 points, respectively. DISCUSSION TKA can provide excellent pain relief and restoration of function for patients. The success of the prosthesis is based on implant survival, in addition to pain relief and restoration of function. This study found good-to-excellent midterm results with the PFC Sigma implant: 88% of the knees were rated excellent. There was only one failure because of technical problems: the tibial component was implanted in 8 Ο of varus, which resulted in early aseptic loosening. Infection was the major cause of failure. The high rate of infection can be attributed to the fact that the University of Malaya Medical Centre is a teaching university hospital with large turnover of medical personnel at all levels. The surgeries were performed by a number of surgeons with different levels of expertise. The infection rate has subsequently been improved with better training and the use of body exhaust suits. All 4 cases of infection arose in patients undergoing simultaneous bilateral knee replacements. It is difficult to say if bilateral operations resulted in higher rate of infection, because only 13 of the 50 patients underwent unilateral procedures. Bilateral knee replacements have been common at our hospital because these allow us to better cope with the demand for TKA. It has been shown that patients undergoing bilateral knee replacement are subjected to a minimally increased morbidity. 7 In spite of this, many of our patients with severe bilateral symptoms were grateful that they needed to endure only one admission, an attitude that has been noted in other studies. 8 The overall infection rate in this series was comparable with those reported in other studies. Font-Rodriguez et al. 9 reported 3 failures, all due to infection, among 49 implants (Insall-Burstein II prostheses), with an overall 10-year success rate of 89%. In a series of 94 knees replaced with anatomic graduated component total knee implants, Alemparte et al. 10 reported 3 knees requiring revision, 2 due to infection, over a follow-up period of 2 to 8 years. Respectively, Society mean knee and functional scores in the present study were 87 and 72 points with a mean follow-up period of 5.4 years, whereas Martin et al. 11 reported 88 and 72 points with a mean follow-up period of 6.5 years, Alemparte et al. 10 reported 89 and 64 points, and Buehler et al. 12 reported 96 and 68 points with a mean follow-up period of 9 years. The mean Oxford Knee Score of this series was 22. The patients scores were reduced largely because of their inability or unwillingness to kneel. Patients were routinely advised by their surgeons not to do so. The mean score on question 7 (Have you been able to kneel in the last 4 weeks?) was 5 (impossible). There was also some confusion between simple

284 S Asif and DSK Choon Journal of Orthopaedic Surgery kneeling (as during prayer in church) and kneeling with deep knee bends (as in the mosque) and squatting. In this retrospective study, we did not have preoperative knee scores to compare with the final knee scores. Polyethylene wear was not reported because we were not able to confidently measure the liners due to rotation of some radiographs. Nonetheless, visual inspection of radiographs showed little discernable wear of the polyethylene liners. No evidence of osteolysis was seen. Three (6%) patients were lost to follow-up despite extensive efforts to contact them; Tooma et al. 13 reported 31% of patients lost to follow-up over 2.5 years, Martin et al. 11 reported 5% over 6.5 years, and Alemparte et al. 10 reported 3.2%. Because the current failure rate of primary TKA was small, this small percentage of missing patients could have markedly affected the final results. CONCLUSION The PFC Sigma total knee prosthesis continues to function well during a mean follow-up period of 5.4 years. These results are comparable to those of other midterm studies. We plan to continue monitoring this cohort for long-term analysis. REFERENCES 1. Millar WJ. Hip and knee replacement. Health Rep 2002;14:37 50. 2. Ritter MA. Session I: long-term followup after total knee arthroplasty. Clin Orthop Relat Res 2002;404:32 3. 3. Halley DK, Charnley J. Results of low friction arthroplasty in patients thirty years of age or younger. Clin Orthop Relat Res 1975;112:180 91. 4. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 1989; 248:13 4. 5. Dawson J, Fitzpatrick R, Murray D, Carr A. Questionnaire on the perceptions of patients about total knee replacement. J Bone Joint Surg Br 1998;80:63 9. 6. Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 1989;248:9 12. 7. Ritter MA, Harty LD, Davis KE, Meding JB, Berend M. Simultaneous bilateral, staged bilateral, and unilateral total knee arthroplasty. A survival analysis. J Bone Joint Surg Am 2003;85:1532 7. 8. Leonard L, Williamson DM, Ivory JP, Jennison C. An evaluation of the safety and efficacy of simultaneous bilateral total knee arthroplasty. J Arthroplasty 2003;18:972 8. 9. Font-Rodriguez DE, Scuderi GR, Insall JN. Survivorship of cemented total knee arthroplasty. Clin Orthop Relat Res 1997; 345:79 86. 10. Alemparte J, Cabezas A, Azocar O, Hernandez R, Acevedo M. Mid-term results of an AGC total knee arthroplasty system survival and function analysis: 2- to 8-year follow-up results. J Arthroplasty 2003;18:420 5. 11. Martin SD, McManus JL, Scott RD, Thornhill TS. Press-fit condylar total knee arthroplasty. 5- to 9-year follow-up evaluation. J Arthroplasty 1997;12:603 14. 12. Buehler KO, Venn-Watson E, D Lima DD, Colwell CW Jr. The press-fit condylar total knee system: 8- to 10-year results with a posterior cruciate-retaining design. J Arthroplasty 2000;15:698 701. 13. Tooma GS, Kobs JK, Thomason HC 3rd, Kelley SS. Results of knee arthroplasty using the cemented press-fit condylar prosthesis. Based on a preliminary report. Am J Orthop 1995;24:831 4.