Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis

Similar documents
Compressive Stress, Shear Stress, and Displacement Study on Different Structured Dental Implant: 3-Dimensional Finite Element Analysis

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

Effect of Screw Profile on Stress Distribution Pattern of Dental Implants by FEA

Evaluation of Stress Distribution in Bone of Different Densities Using Different Implant Designs: A Three-Dimensional Finite Element Analysis

Dental Research Journal

Three-dimensional optimization and sensitivity analysis of dental implant thread parameters using finite element analysis

Comparative study of single-thread, double-thread, and triple-thread dental implant: a three-dimensional finite element analysis

Research Article Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

ABSTRACT INTRODUCTION

Influence of Different Angulations of Force in Stress Distribution in Implant Retained Finger Prosthesis: A Finite Element Study

Experimental and Numerical Comparison of Stresses Level between Titanium and Novel Composite Single Tooth Implant

STUDYING THE EFFECT OF THE PRELOAD INDUCED BY SCREW TIGHTENING ON STRESS DISTRIBUTION OF A DENTAL IMPLANT

A review: Mechanical Design of Dental Implants to Reduce Stresses around Implant-Bone Interface

Finite Element Analysis of Dental Implant as Orthodontic Anchorage

Three-dimensional finite element analysis of the application of attachment for obturator framework in unilateral maxillary defect

Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis

Influence of Bone Implant Contact on Biomechanical Performance of Short Implant Placed in Atrophic Posterior Mandible

Influence of Bone Implant Contact on Biomechanical performance of Short Implant Placed in Atrophic Posterior Mandible

JCAMECH Vol. 46, No. 2, July 2015, pp

Modelling of temporomandibular joint and FEM analysis

INFLUENCE OF CANTILEVER ON STRESS DISTRIBUITION IN BONE AROUND DENTAL IMPLANTS: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

IS THE PALATE AN OPTIMAL SITE FOR MINISCREW PLACEMENT?

Three dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone

MECHANISM OF LOAD TRANSFER ALONG THE BONE- DENTAL IMPLANT INTERFACE

Optimizing Dental Implant Model by Comparison of Three Dimensional Finite Element

An effort is made to analyse the stresses experienced by the human femur. In order

Student Presentation # 3 Biomechanics

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

AnyRidge Internal System

EVALUATION OF STRESS DISTRIBUTION AND MICROMOTION OF DENTAL IMPLANT: IN VIVO CASE STUDY

The fundamental biomechanics of oral implants. Dr. Szűcs Attila

Three dimensional finite element analysis of immediate loading mini over denture implants with and without acrylonitrile O ring

Finite element analysis of prosthetic knee joint using ANSYS

Journal of Dental Research, Dental Clinics, Dental Prospects. Original Article

Objective: The occlusal patterns are key requirements for the clinical success of oral

Biomechanical Analysis of Jaw Bone with Cyst Using CT-Image Based Finite Element Method

IJPCDR INTRODUCTION ABSTRACT

Available online at ScienceDirect

Stress Analysis of an Endosseus Dental Implant by BEM and FEM

Since the introduction of the Branemark

Stress in the Mandible with Splinted Dental Implants caused by Limited Flexure on Mouth Opening: An in vitro Study

Where technology meets dentistry INNOVATION. at a GLANCE

FEM analysis of the mandibular first premolar with different post diameters

Keywords: Angioplasty, Explicit finite elements method, Tube hidroforming, Stents.

Improved Processing Research on Arc Tooth Cylindrical Gear

Design and Analysis of Dental Surgical Fixture

Research on defects and control method based on thread shaft forming Huajun Yan1, 2, a, Shuangjie Zhang1, 2, b, Shibo Ma1, 2, c

International Journal of Engineering Research and Development e A Mathematical Model to Calculate Contact Stresses In Artificial Human Hip Joint

Comparative analysis of the stress distribution in five anatomical types of maxillary central incisor

Fatigue Life Analysis of Spur Gears with Precise Tooth Profile Surfaces

Dental Implants: Hex or Conical Connection?

STRESS ANALYSIS OF DENTAL IMPLANT INSERTED IN THE MANDIBLE

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A mimic osseointegrated implant model for three-dimensional finite element analysis

Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method

Australian Dental Journal

Numerical predicting of contact and pressure sore of lower extremity parts caused by prosthetic and orthotic

Effect of alveolar bone support on zygomatic implants in an extra-sinus position an FEA study

Topology optimisation of hip prosthesis to reduce stress shielding

Performance Assessment of Various Molar Crown Designs

Biomechanical Analysis of Different Knee Prosthesis Biomaterials Using Fem

Finite Element Analysis of Radius and Ulna. Eli Pavlatos April 24, 2013

JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH

BENDABLE VS. ANGULATED DENTAL IMPLANTS: CONSIDERATION OF ELASTIC AND PLASTIC MATERIAL PROPERTIES BASED ON EXPERIMENTAL IMPLANT MATERIAL DATA AND FEA

Peri-Implant Stress Analysis of Immediate Loading and Progressive Loading Implants in Different /jp-journals

Mechanical and technical risks in implant therapy.

[ICESTM-2018] ISSN Impact Factor

On the feasibility of speckle reduction in echocardiography using strain compounding

Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis.

There had been controversies concerning how to achieve maximum anchorage in the first premolar extraction cases.

Effect of the femoral stem size on femur bone quality towards THR

Modal analysis of maxillary central incisor tooth

Design and Implementation of Software Planning System for Dental Robot

ACCURATE NUMERICAL ANALYSIS OF GEAR STRENGTH BASED ON FINITE ELEMENT METHOD

Anuradha Borse 1* Rubina Tabassum 2 Omkar Shetty 3

Dental Implants Resistance: Computational Analysis

More than pure esthetics. The natural and strong solution.

Comparison of Platform Switched and Sloping Shoulder Implants on Stress Reduction in various Bone Densities: Finite Element Analysis

Evaluation of Effect of Connector Designs in Implant Tooth-supported Fixed Partial Denture: A Two-dimensional Finite Element Analysis

Summer Workshop of Applied Mechanics. Influence of implant length and diameter on stress distribution

NUMERICAL STUDY OF STRESSES IN DENTAL MATERIALS BY USING FINITE ELEMENT ANALYSIS

Osseointegrated dental implant treatment generally

Effects of Mesiodistal Inclination of Implants on Stress Distribution in Implant-Supported Fixed Prostheses

While the high rate of success of dental

education, Uzhgorod Engineering, Department of Dynamics and Resistibility of Materials, Kyiv Zaporizhzhya

FINITE ELEMENT ANALYSIS OF PERIODONTAL STRESSES IN FIXED PROSTHODONTICS

Case study for quality control & quality assurance in metal additive manufacturing: A dental bridge

Genome-wide association study of esophageal squamous cell carcinoma in Chinese subjects identifies susceptibility loci at PLCE1 and C20orf54

3D-Guide. Scanbody for high-precision implant position transfer INTERNATIONAL PATENT BENEFITS: APPLICATION: TECHNICAL DETAILS:

Shrikar R. Desai, I. Karthikeyan, and Rika Singh. 1. Introduction

A fresh look at implantology

SHAPE OPTIMIZATION AND TOLERANCE ANALYSIS OF DENTAL IMPLANTS BY MEANS OF VIRTUAL MODELS

STRESS ANALYSIS OF THE RADIAL HEAD REPLACEMENTS IN AN ELBOW ARTICULATION

Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant - a 68 month follow-up study

ISO INTERNATIONAL STANDARD. Dentistry Implants Dynamic fatigue test for endosseous dental implants

Study on Mechanical Characteristics of Lumbar Spine for Snatch Action in Weight Lifting Based on Finite Element Method

Evaluation Of Contact Pressure On Total Surface Bearing And Patellar Tendon Bearing Sockets During Stair Ascent And

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

Summer Workshop of Applied Mechanics. Theoretical Analysis of Total Hip Joint Replacement of Sandwich design by FEM

Transcription:

1 Research Article Stress and Displacement Analysis of Dental Implant Threads Using Three-Dimensional Finite Element Analysis Aswin Yodrux* Department of Materials Handling and Logistics for Engineering, Faculty of Engineering, King Mongkut s University of Technology North Bangkok, Bangkok, Thailand Nantakrit Yodpijit Center for Innovation in Human Factors Engineering and Ergonomics, Department of Industrial Engineering, Faculty of Engineering, King Mongkut s University of Technology North Bangkok, Bangkok, Thailand Manutchanok Jongprasithpornt Department of Industrial Engineering, Faculty of Engineering, King Mongkut s Institute of Technology Ladkrabang, Bangkok, Thailand * Corresponding author. E-mail: aswin.y@eng.kmutnb.ac.th DOI: 10.14416/j.ijast.2018.09.002 Received: 3 August 2017; Accepted: 15 November 2017; Published online: 6 September 2018 2019 King Mongkut s University of Technology North Bangkok. All Rights Reserved. Abstract Dental implant is one of the most common ways to replace a missing tooth. The objective of this research project is to analyze the compressive stress, shear stress, and displacement of prosthetic tooth. This research is conducted using a three-dimensional finite element method to analyze biomechanical characteristics on dental implant systems at four different areas: abutment, implant, cortical bone, and cancellous bone. This research focuses on a variety of patents of dental implant threads from the United States Patent and Trademark Office. Findings reveal a new conceptual design of dental implant thread model. It is found that the maximum stress concentration is found at cortical bone but is still lower than the yield strength of materials. The new design of dental implant tread provides the minimum compressive stress, shear stress, and displacement for dental implant systems. Keywords: Biomechanical analysis, Dental implant systems, Three-dimensional finite element method 1 Introduction Dental implants have been extensively used during the last few decades as replacements for missing natural teeth [1]. Titanium metals has become the preferred materials for dental implants owing to their good biocompatibility, excellent corrosion resistance and suitable mechanical properties [2]. Three-dimensional finite element analysis is a useful tool that has been applied to simulate behavior biomechanical characteristics on dental implant systems under comprassive loading [3]. This research focuses on a variety of patents of dental implant threads from the United States Patent and Trademark Office to new design model of implant prosthetics [4] [6]. The result of comprassive stress, shear stress and displacements have been studied. 2 Material and Methods 2.1 Three-dimension model design Three-dimensional geometrical model of dental implant prosthetics and the surrounding bone was created by Please cite this article in press as: A. Yodrux, N. Yodpijit, and M. Jongprasithpornt, Stress and displacement analysis of dental implant threads using three-dimensional finite element analysis, Appl. Sci. Eng. Prog., (2019). DOI: 10.14416/j.ijast.2018.09.002

2 Abutment Cortical bone 1.0 mm 1.0 mm Implant Cancellous bone 4 (a) Model A: New design thread A with a pitch of 1.0 mm (d) Model D: New design thread B with a pitch of 1.0 mm Figure 1: Three-dimensional geometrical model of dental implant prosthetic and the surrounding bone. the Computer Aided Design (CAD) modelling for testing by three-dimensional finite element analysis. All the CAD models in this study are made, using CATIA program by solid modelling (Figure 1). For the three-dimensional finite element analysis models generation, the implant thread was placed in a simplified jaw segment, a cancellous bone core surrounded by a 1.5 mm thick cortical bone layer was designed around the implant. The dimensions of the simulated bone block were 24.2 mm high and 16.3 mm wide [7], [8]. This research focuses on six implant prosthetics model of dental implant systems, from Figure 2 illustrated 3D thread category of implant prosthetics. 2.2 Materials properties In the study, Titanium (Ti6Al-4V) was used as implant and abutment materials. The mechanical properties of materials were taken from the literature, as shown in Table 1 [9] [14]. Table 1: Mechanical properties of materials Materials Young s modulus, E (MPa) Poisson s Ratio, υ Cortical Bone 13,000 0.3 Cancellous Bone 1,370 0.3 Implant (Ti6Al-4V) 102,000 0.35 Abutment (Ti6Al-4V) 102,000 0.35 2.3 Loading and boundary condition The dental implant system is treated as isotropic homogeneous elastic materials. All material of the 4 Figure 2: 3D thread category of six implant prosthetics model. dental implant was assumed to be isotropic and linearly elastics. Three-dimensional finite element analysis was performed on dental implant models with compressive forces of 100 N, and a shear force of 50 N with the force angle of 45 with the normal line respectively [15], [16]. Figure 3 show Loading conditions applied on dental implant system model. The shape of the three-dimensional finite element analysis model of the dental implant prosthetics model is shown in Figure 4. After loading, the result of comprassive stress, shear stress and displacements were calculated by three-dimensional finite element analysis for each of the different regions of the dental implant prosthetics model: abutment, implant, cortical bone, and cancellous bone. 3 Results 1.5 mm (b) Model B: New design thread A with a pitch of 1.5 mm 4 2.0 mm (c) Model C: New design thread A with a pitch of 2.0 mm 1.5 mm 2.0 mm (e) Model E: New design thread B with a pitch of 1.5 mm (f) Model F: New design thread B with a pitch of 2.0 mm The compressive stress, shear stress and displacement

3 z 100 N 50 N 45 x 1.5 mm 24.2 mm 16.3 m m Figure 5: The stress distribution of abutments. 16.3 mm Figure 3: Loading conditions applied on dental implant system model. Figure 6: The stress distribution of implants. Figure 4: The three-dimensional finite element analysis model of the dental implant systems. analysis were conducted at four different areas, including abutment, implant, cortical bone, and cancellous bone. 3.1 Stress distribution As show in Figure 5, the resulting stress distribution in three-dimensional finite element analysis of abutments of dental implant prosthetics under compressive force Figure 7: The stress distribution of cortical bone. Figure 6 illustrates the stress distribution in three-dimensional finite element analysis of implants of dental implant prosthetics under compressive force. Figure 7 illustrates the stress distribution in threedimensional finite element analysis of cortical bone under compressive force. Figure 8 illustrates the stress distribution in threedimensional finite element analysis of cancellous bone under compressive force.

4 Figure 8: The principal stress of cancellous bone. 20 15 10 5 0 Figure 9: The Von Mises stress of abutments. 35.00 3 25.00 2 15.00 5.00 4.63 14.73 Figure 10: The Von Mises stress of implants. 3.2 Von mises stress 8.21 Results of the Von mises stress in three-dimensional finite element analysis of abutments of dental implant prosthetics under a compressive force are given in Figure 9. It reveals that the maximum stress of 16.21 MPa is found at thread E and the minimum stress of 4.63 MPa is found at thread A. Results of the stress in three-dimensional finite element analysis of implants of dental implant prosthetics under a compressive force are given in Figure 10. It reveals that the maximum stress of 28.51 MPa is found at thread D and the minimum stress of 11.26 MPa is found at thread E. Results of the stress in three-dimensional finite element analysis of cortical bone under a compressive 6.62 16.21 11.24 25.86 14.68 16.31 28.51 11.26 25.86 Figure 11: The Von Mises stress of cortical bone. Figure 12: The Von Mises stress of cancellous bone. 4 35.00 3 25.00 2 15.00 5.00 2.50 1.50 1.00 0.50 8.00 6.00 4.00 28.85 Figure 13: Shear stress of abutments. force are given in Figure 11. It reveals that the maximum stress of 36.36 MPa is found at thread B and the minimum stress of 7.86 MPa is found at thread F. Results of the stress in three-dimensional finite element analysis of cancellous bone under a compressive force are given in Figure 12. It reveals that the maximum stress of 1.91 MPa is found at thread B and the minimum stress of 0.58 MPa is found at thread E. 3.3 Shear stress 36.36 15.14 22.43 10.03 Results of shear stress in 3D-FEA of abutments under a shear force are given in Figure 13. It reveals that the maximum shear stress of 5.73 MPa is found at thread B and the minimum shear stress of 0.77 MPa is found 7.86 1.55 1.91 1.46 0.87 0.58 0.59 1.80 5.73 1.49 0.77 1.73 4.03

5 18.00 16.00 14.00 1 8.00 6.00 4.00 8.96 6.03 16.29 13.26 4.46 Figure 14: Shear stress of implants. 8.88 0.0120 80 60 40 20 00 66 82 93 72 89 Figure 17: Displacement of abutments. 76 10 9 8 7 6 5 4 3 2 2.50 1.50 1.00 0.50 88.44 25.71 13.47 47.03 86.75 Figure 15: Shear stress of cortical bone. 30.20 2.26 1.18 1.20 Figure 16: Shear stress of cancellous bone. at thread D. Results of shear stress in three-dimensional finite element analysis of implants under a shear force are given in Figure 14. It reveals that the maximum shear stress of 16.29 MPa is found at thread C and the minimum shear stress of 4.46 MPa is found at thread E. Results of shear stress in three-dimensional finite element analysis of cortical bone under a shear force are given in Figure 15. It reveals that the maximum shear stress of 88.44 MPa is found at thread A and the minimum shear stress of 13.47 MPa is found at thread C. Results of shear stress in three-dimensional finite element analysis of cancellous bone under a shear force are given in Figure 16. It reveals that the maximum shear stress of 2.26 MPa is found at thread A and the minimum shear stress of 0.87 MPa is found at thread D. 0.87 1.46 1.30 80 60 40 20 00 21 Figure 18: Displacement of implants. 3.4 Displacement 51 44 41 47 51 Results of displacement in three-dimensional finite element analysis of abutments under compressive force are given in Figure 17. It reveals that the maximum displacement of 93 mm is found at thread C and the minimum displacement of 66 mm is found at thread A. Results of displacement in three-dimensional finite element analysis of implants under compressive force are given in Figure 18. It reveals that the maximum displacement of 51 mm is found at thread B, F and the minimum displacement of 21 mm is found at thread A. Results of displacement in three-dimensional finite element analysis of cortical bone under compressive force are given in Figure 19. It reveals that the maximum displacement of 78 mm is found at thread B, E and the minimum displacement of 07 mm is found at thread D. Results of displacement in three-dimensional finite element analysis of abutments under compressive force are given in Figure 20. It reveals that the maximum displacement of 92 mm is found at thread C and the minimum displacement of 09 mm is found at thread D.

6 80 60 40 20 00 80 60 40 20 00 72 Figure 19: Displacement of cortical bone. 56 53 92 09 62 25 Figure 20: Displacement of cancellous bone. 4 Disccussions and Conclusions The purpose of this research study was to analyze the compressive stress, shear stress, and displacement of prosthetic tooth. This research is conducted using a three-dimensional finite element method to analyze biomechanical characteristics on dental implant systems at four different areas: abutment, implant, cortical bone, and cancellous bone. In the study, Titanium (Ti6Al-4V) was used as implant and abutment materials. It was considered as the yield strength of Titanium grade 4 a value of 550 MPa. This resarch have focused on six different threads shape of dental prosthetics model. From this research, The maximum compressive stress occurred in four different areas, including abutment, implant, cortical bone, and cancellous bone are less than the yield strength of materials. The study of minimum shear stress and minimum displacement analysis occurred in four different areas, including abutment, implant, cortical bone, and cancellous bone are found at new design thread B with a picth of 1 mm. Hence the design is safe. Acknowledgments 78 45 07 78 38 Authors would like to express our sincere appreciation to researchers and staff at the Center for Innovation in Human Factors Engineering and Ergonomics, Department of Industrial Engineering, Faculty of Engineering, King Mongkut s University of Technology North Bangkok (KMUTNB) for technical supports. References [1] Y. Gao, Y.-F. Li, B. Shao, T. Li, N. Xia, L.-X. Xu, Z.-Y. Wang, and L. Kong, Biomechanical optimisation of the length ratio of the two endosseous portions in distraction implants: A three-dimensional finite element analysis, British Journal of Oral and Maxillofacial Surgery, vol. 50, pp. e86 e92, 2012. [2] C. Liang-jian, H. Hao, L. Yi-min, L. Ting, G. Xiao-ping, and W. Rui-fang, Finite element analysis of stress at implant-bone interface of dental implants with different structures, Transactions of Nonferrous Metals Society of China, vol. 21, pp. 1602 1610, 2011. [3] L. Zheng, J. Yong, X. Hu, and J. Luo, The dimensional finite element analysis of a novel osteointegrated dental implant designed to reduce stress peak of cortical bone, Acta of Bioengineering and Biomechanics, vol. 16, no. 3, pp. 21 28, 2014. [4] H. Zipprich, Dental Implant System, U.S. Patent 20140212844A1, Jul. 31, 2014. [5] Bo-Wei Peng, Dental Implant, U.S. Patent 0140816800A1, July 3, 2014. [6] T. Buurlage, Dental Implant, U.S. Patent 20140147808A1, May 29, 2014. [7] C.-L. Lin, Y.-C. Kuo, and T.-S. Lin, Effects of dental implant length and bone quality on biomechanical responses in bone around implants: A 3-D nonlinear finite element analysis, Biomedical Engineering Applications Basis and Communications, vol. 17, no. 1, pp. 44 49, 2005. [8] M. Mangalvedhekar and M. Herekar, The influence of location of oeelusal loading on stresses transferred to implant-supported prostheses and supporting bone: A three dimensional finite element study, Asian Journal of Midical and Clinical Sciences, vol. 3, pp. 63 67, 2014. [9] L. Kong, Y. Zhao, K. Hu, D. Li, H. Zhou, Z. Wu, and B. Liu, Selection of the implant thread pitch for optimal biomechanical properties: A threedimensional finite element analysis, Advances

7 in Engineering Software, vol. 40, pp. 474 478, 2009. [10] L. Kong, Z. Gu, K. Hu, H. Zhou, Y. Liu, and B. Liu, Optimization of the implant diameter and length in type B/2 bone for improved biomechanical properties: A three-dimensional finite element analysis, Advances in Engineering Software, vol. 40, pp. 935 940, 2009. [11] Y. Sun, L. Kong, K. Hu, C. Xie, H. Zhou, Y. Liu, and B. Liu, Selection of the implant transgingival height for optimal biomechanical properties: A three-dimensional finite element analysis, British Journal of Oral and Maxillofacial Surgery, vol. 47, pp. 393 398, 2009. [12] J.-R. Xiao, Y.-F. Li, S.-M. Guan, L. Song, L.-X. Xu, and L. Kong, The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants: A 3-dimensional finite element analysis, Bitish Journal of Oral and Maxillofacial Surgery, vol. 69, pp. e273 e281, 2011. [13] Y. Gao, Y.-F. Li, B. Shao, T. Li, N. Xia, L.-X. Xu, Z.-Y. Wang, and L. Kong, Biomechanical optimisation of the length ratio of the two endosseous portions in distraction implants: A three-dimensional finite element analysis, British Journal of Oral and Maxillofacial Surgery, vol. 50, pp. e86 e92, 2012. [14] T. Li, X. Yang, D. Zhang, H. Zhou, J. Shao, Y. Ding, and L. Kong, Analysis of the biomechanical feasibility of a wide implant in moderately atrophic maxillary sinus region with finite element method, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, vol. 114, pp. e1 e8, 2012. [15] M. Mangalvedhekar and M. Herekar, The influence of location of occlusal loading on stresses transferred to implant-supported prostheses and supporting bone: A three dimensional finite element study, Asian Journal of Medical and Clinical Sciences, vol. 3, no. 2, pp. 63 67, 2014. [16] H. Abuhussein, G. P agin, A. Rebaudi, and H.-L. Wang, The effect of thread pattern upon implant osseointegration, Clinical Oral Implants Research, vol. 21, pp. 129 136, 2010.