Preliminary technical data

Similar documents
Technical data TECHNICAL DATA

Lunar idxa. The intelligent DXA. gehealthcare.com

Lunar Prodigy Advance

Healthy aging. It s vital.

Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT

Dual-energy Vertebral Assessment

QDR Series. Discovery and Explorer Advanced Health Assessment

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

The Bone Densitometry Examination

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

2013 ISCD Official Positions Adult

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

THYROID UPTAKE SYSTEMS

Lunar idxa. The intelligent DXA. gehealthcare.com

Documentation, Codebook, and Frequencies

Bone Densitometry Radiation dose: what you need to know

week by week in the Training Calendar. Follow up graphics, sort, filter, merge, and split functions are also included.

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

DC-6. Diagnostic Ultrasound System

2013 ISCD Combined Official Positions

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Lunar Prodigy Advance

SURETEST Torque Calibration System

Bone Densitometry Equipment Operator

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

SURETEST Torque Calibration System

The Key to Confidence

Versatility And Expandability In One Panoramic.

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

Norland Densitometry A Tradition of Excellence

Use of DXA / Bone Density in the Care of Your Patients. Brenda Lee Holbert, M.D. Associate Professor Senior Staff Radiologist

Digital Dentistry Solution

True Low Dose. Exact time to display image on screen may vary upon computer and network configuration.

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

Innovations 2017 & 2018

CT SCAN PROTOCOL. Shoulder

Features and Benefits

9 Quality Assurance in Bone Densitometry section

Powerful images. Clear answers.

CS 9300 Family. The power of flexibility

A Web based Computer aided Diagnosis Tool for Bone Age Assessment:

Head to new heights with your imaging SCANORA 3D

Digital Dentistry Solution

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA)

Premium solution for your health

ACTIVITY SCANNER NEW. 3D Dental Scanner made in Germany.

DELPHI. The standard in point-of-care fracture risk assessment. Now with Image Pro.

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

MEDILINK PEGASUS Smart. The New Portable ultrasound Bone densitometer

Accuracy of DEXA scanning & other methods for determining BMD.

WITH. The Next Step in Office MRI

Segmentation of vertebrae in lateral lumbar spinal X-ray images

BC310. Body Composition Analyzer. Medical Diagnostic Device

Sectra Orthopaedic Solutions

Orthopedic Pre-operative Planning and Templating with Digital X-ray Images

THE WAIT IS OVER CS D. 3D imaging is now available for everyone

CT Imaging at the Point-of-Care

SCALING Radiographic Technique

medical software for trauma and ortopedic surgery planning

English. Perfect Vision

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

The New Frontier in Hip Preservation Preoperative CT-based Planning for FAI correction

SpiderX. Portable Residual Stress X-Ray Diffractometer.

AD226 Diagnostic Audiometer

Atomlab. Thyroid Uptake System BIODEX. A complete, mobile, Medical Spectrometer. The Clinical Advantage.

CT Imaging of skeleton in small animals. Massimo Marenzana

I AM DEMANDING Type CMOS Flat Panel CMOS CMOS ø 40 x 40 mm, ø 60 x 60 mm, ø 80 x 80 mm, ø 110 x 80 mm

The Definitive Dental 3D Printing Solution

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Version Date: 2015-OCT-29. Effective Date: 2015-NOV-19

Diagnostische Präzision von DXL im Vergleich zu DXA bei pmp Frauen mit Frakturen

Clinical Densitometry

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

BC ACCUNIQ BC310 Specifications. Body Composition Analyzer. Medical Diagnostic Device

The Bone Wellness Centre - Specialists in Dexa Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Desktop Fitting Guide for Phonak Brio 3

DWS, Additive Manufacturing. Smart, Effective and Italian.

Health Care & Human Care

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

PAN CEPH 3D CONE BEAM

For Convenient Use

Annotations Part III Vertebral Fracture Initiative. International Osteoporosis Foundation March 2011

chapter Bone Density (Densitometry) RADIOPHARMACY INDICATIONS Radionuclide Localization Quality Control Adult Dose Range Method of Administration

Xperius Ultrasound System Responsive Advanced Simple NEW

BC510. Body Composition Analyzer. Medical Diagnostic Device

Now offering a Real-time dose measurement system featuring RaySafe i3. Powered by

3D Cone beam CT & Digital Radiography Dedicated to Otorhinolaryngology

Planmeca ProMax 3D s Planmeca ProMax 3D ENGLISH

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

Transcription:

Preliminary technical data 2D-FanBeam Whole Body Densitometer PROGRESS THROUGH INNOVATION

2D-Fan Beam Whole Body Densitometer Acquisition chain parameters Dual Emission X-ray Absorptiometry (DEXA) 2D-FanBeam with X and Y kinematics Generator X-ray continuous generator Manufacturer Cooling system High voltage Maximum tube current High frequency monoblock IMD Immersion in oil + cooling fans 110 kv 2.4 ma X-ray tube Type Tungsten fixed anode Localization Under the patient Anode angle 12 Anode-cathode direction Horizontal X-ray beam fan type Focal point dimension 0.6 x 0.6 mm Energy splitting Filtering: samarium 200 µm + aluminium 2mm Tube Collimator Material Size Collimator-patient distance Tube-patient distance Shutter Lead 18 mm 2.5 mm 77 mm 270 mm 4 mm lead Detector Collimator Material Height Size Brass 30 mm 72mmx8 mm Detector Quantity Type of detection Material Specification Detector pixel pitch Localization 1( 2D array: 4 x 64 pixels) Direct detection cdte (1mm) Photon counting, energy sensitive 1.1 mm x 1.6 mm Above the patient Scanner Scanning method Maximum scan area Scanning type Table type Rectilinear scan 200 x 65 cm Motorized arm with X and Y kinematics Fixed for all exams including the Whole Body mode Acquisition method Type Method 2D Fan Beam technology Dual Energy X ray Absorptiometry (90/110 kv) Acquisition windows Scan window size Multisite (L x W) Whole Body (L x W) Isotropic image without magnification Adjustable to patient s morphology Customizable scan area 200 x 65 cm maximum Page2 on 8

2D-Fan Beam Whole Body Densitometer Advanced Morphometrictools Fracture risk information using Hip Structural Analysis (HSA) Diagnostic tools Examination sites AP spine (L1- L4) Forearm: Ultradistal, Mid-radius and Distal (1/3) Hip: Total Hip, Femoral neck, trochanter, intertrochanter, Ward zone Total Hip: Combined examination of the left and right hip In-Row Scan: Combined examination of the lumbar spine and of the left or right hip Whole body: total or local (left arm, right arm, left ribs, right ribs, t spine, l spine, pelvis, left leg, right leg, head) Twin Hip Diagnostic tools Calculation of Bone Mineral Density (BMD), Bone Mineral Content (BMC), surface, T-score and Z-score Advanced Morphometric tools (surface, distance and angle): Bone can be measured on every type of examination (spine, hip, forearm) Automated Hip Structural Analysis (HSA): Hip Axis Length (HAL), Femoral Neck Axis Length (FNAL), Intertrochanter to Femoral Head Center Distance (IH) and Femoral axis versus Neck axis Angle (FNA) Fracture risk information using Hip Structural Analysis (HSA) FRAX tool to evaluate probability of osteoporotic fractures Fracture risk information Diagnostic tools Whole body examination: Total BMD, Total BMC, surface, local BMD, local BMC, Tscore, Zscore and body composition Digital Vertebral Assessment (DVA): Provides a low dose, lateral image of the spine (to view all the vertebrae of the spine).the deformation or compression is precisely diagnosed, measured and classified. This analysis can be either automatic using the Genant s semi-quantitative classification, or manual using the Genant s visual classification (L4 - T2) Lateral spine BMD: To measure the bone density of the vertebrae of the lumbar spine from a lateral angle and without spinal backbone Paediatrics: To measure the BMD (spine and whole body) and the whole body composition Orthopaedics: To measure the BMD around the prosthesis (ex: Gruen zone selection). Enables a smart implant management. Available for hand, forearm, elbow, shoulder, spine, hip, AP knee, lateral knee, feet. Automatic detection of ROI for hip, knee and lateral knee examinations Page3 on 8

2D-Fan Beam Whole Body Densitometer Analysis Manual and automatic analysis for all exams Parameters available on final medical report Multisite Bone Mineral Density (BMD) expressed in g/cm 2, stands for the mineral density of the bones Bone Mineral Content (BMC) expressed in g, stands for the mineral mass of the bones Area expressed in cm 2, 2D projection of the bone T-score = Difference between the patient s values and the mean value of a young population of healthy subjects of the same gender and from the same ethnic background as the patient, divided by the standard deviation of a young population of healthy subjects Z-score = Difference between the patient s value and the mean value of a population of healthy subjects of the same age, divided by the standard deviation Whole body Total Bone Mineral Density (BMDt) Local Bone Mineral Density (BMDl) Area Body Composition Fat mass Leanmass Bone mineral mass Total and local body composition Color mapping for visualizing the fat areas T-score Z-score Orthopaedic Bone Mineral Density (BMD) Bone Mineral Content (BMC) Area Automatic ROI selection (ex: Gruen zone), for hip, knee and lateral knee Paediatric Bone Mineral Density (BMD) Bone Mineral Content (BMC) Area Body composition Z-score Skeletal age comparison Reference curve Displays the BMD according to the age for the examined region(s). It enables to supply T-score and Z-score values as diagnosis values Morphometry Specification of the clinical data Bone Mineral Density (BMD) Quantitative morphometry (areas, lengths, angles). ex: Automatic Hip Structural Analysis (HSA) ± 1.0% in vivo (± 0.5% in vitro) Page4 on 8

2D -Fan Beam Whole Body Densitometer Software New user friendly interface Evolutionary software Software tools Patient follow-up graphs Advanced Morphometric tools (distance, angle and area) ex: hip length axis Calculation of standardized BMD (comparison to NHANES III normative data) Easy scan repositioning from PC method Customizable user interface (colours, trend, results, print - out, etc.) Multi-user (different profiles can be configured: operator, physician, etc.) Reference population (reference normality curve): Caucasian, Asian, NHANES-III, African, Turkish, Hispanic,,Japanese and Korean Personalized multiple reference populations (normality curves editor) Patient s data follow-up: Data base importation from another device + Previous data input Customizable automatic/semi automatic database archiving Multi-report for comparative purposes Customizable reports (header, footer, predefined forms,letters, etc.) Detailed colour print out of reports (bone + reference curve + analysis report + operator comments + patient and physician letters + followup), configurable by the physician Email reports sending Automatic and customizable letter (patient and physician) Image display tools: Contrast, brightness and zoom Density display in colour scale Multi-language software: Chinese simplified, Czech, German, English, Spanish, French, Italian, Polish and Turkish (other languages can be translate) Help menu DVO recommendations (Certified by DachVerband Osteologie) Multi report Optional software tools Telemaintenance software: network connection required Touch screen Storage CD, DVD or external hard drive Connectivity DICOM compatibility (Output HIS, RIS, PACS (options)) Push & Print : Storing, printing and transferring patient s data Worklist (option): To manage the patient list Workstation mode (option): Possibility to connect from multiple distant workstations and access to device data Multi-user mode (option) : Login, logout and rights management Formatused to export image data:.jpg or.pdf Page5 on 8

2D-Fan Beam Whole Body Densitometer Examination parameters Automatic and manual selection of the Region Of Interest (ROI) Low dose adapted to patient morphology Doses Examination time and pixel size Hip Pixel size Examination time Scanning speed Fast 1 mm2 30 s 220 mm/s Accuracy 0.5 mm2 60 s 220 mm/s AP Spine Pixel size Examination time Scanning speed Fast 1 mm2 30 s 280 mm/s Accuracy 0.5 mm2 60 s 280 mm/s Lateral Spine Pixel size Examination time Scanning speed Fast 1 mm2 30 s 250 mm/s Accuracy 0.5 mm2 60 s 250 mm/s DVA Pixel size Examination time Scanning speed Fast 1 mm2 60 s 280 mm/s Accuracy 0.5 mm2 2 min 280 mm/s Forearm Pixel size Examination time Scanning speed Fast 1 mm2 30 s 220 mm/s Accuracy 0.5 mm2 60 s 220 mm/s Whole body Pixel size Examination time Scanning speed Fast 2 mm2 3 min 260 mm/s Normal 1 mm2 5 min 260 mm/s Accuracy 1 mm2 8 min 260 mm/s Body composition: 3 min, achieved at the same time of the Whole body exam Total hip: 1min In Row Scan: 1 min Patient positioning Laser light Easy scan repositioning from PC method Method of examination Pre-regulated exam modes: Exam parameters adjusted automatically based on patient s morphology (Thinness, Health and Overweight) Personalized: Motor drive speed (mm/sec) and selectable image height and width Automatic and manual selection of the Region Of Interest (ROI) = Intelligent Scan Acquisition IntelliScan: Smart reduction of the scan window and of the examination time Specifications of the clinical parameters Age grouping Weight 15 95 years old (4-18 years old in paediatric mode) < 210 kg Calibration and quality control Quality control using external phantom Quality control trend plotting integrated to the software Control by internal reference between each scan Page6 on 8

Preliminary 2D - Fan Beam Whole Body Densitometer Minimal computer configuration Computerparameters Operating system Windows XP,Vista, Seven, 8, 8.1 or Windows 10 Processor RAM Hard disk CD Romor DVD drive Archiving Monitor Printer Connectivity Processor dual core1ghz 1 GB 100 GB For updating software CD, DVD burner or external hard drive SVGA resolution 1024x768 Color 2 LAN port for communication and DICOM (LAN for DICOM can be supplied by USB to LAN converter) Environmental data and electrical specifications Environmental data Operating temperature Operating humidity Pressure Storage temperature Storage humidity Radioprotection 20 to 28 C(68 to 82.4 F) 20%- 80% (withoutcondensation) 0.8 1.2 Bar 10 to 40 C (50 to 104 F) 20%- 80% (withoutcondensation) No external shielding required Electrical specifications Voltage-Current Frequency Power consumption 110 VAC- 10 A 210-230 VAC- 5 A 50/60 Hz 560 W

Preliminary 2D -Fan Beam Whole Body Densitometer Physical description Dimensions and weight Dimensions L 240 x W 125 x H 130 cm (L 94 x W 49 x H 51 ) Examination table L 240 x W 110 cm (L 94 x W 43 ) Mattress L 208 x W 72.5 cm (L 82 x W 28 ) Patient table lowest height 60 cm (24 ) Weight 250 kg (521 lbs) Physical characteristics Room layout