Totally indwelling venous access devices

Similar documents
THE CARE AND MAINTENANCE OF TOTALLY IMPLANTED VENOUS ACCESS DEVICES (PORTS)

Per-Q-Cath* PICC Catheters with Excalibur Introducer* System

Peel-Apart Percutaneous Introducer Kits for

Overview of CVADs. Type of device commonly used. Dwell time Flushing requirement Associated complications. lumens

Designed to Reduce the Risk of Occlusion (1)

NOTTINGHAM CHILDREN S HOSPITAL Nursing Guideline. P07 Care and Management of Children with a Totally Implantable Venous Access Device (Portacath).

Central Venous Access Devices. Stephanie Cunningham Amy Waters

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

Education for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Choosing the right access for long term parenteral nutrition: PICC lines or tunnelled catheters G. Goossens (BE)

Curraheen, Co. Cork. Guidelines on the Management and Care of Central Venous Access Devices

FLEXIC ATH LTD. Peripherally Inserted. Instructions n For Use.

IV Fluids Nursing B23 Objectives Serum Osmolality 275 to 295 Isotonic

Vascu-PICC WITH CUFF PERIPHERALLY INSERTED CENTRAL VEIN ACCESS CATHETER INSTRUCTIONS FOR USE

IV Fluids. Nursing B23. Objectives. Serum Osmolality

Central venous access devices for children with lysosomal storage disorders

Peripherally Inserted Central Catheter (PICC) Booklet

Vaxcel Implantable Ports Valved and Non-Valved. A Patient s Guide

The Impact of Catheter Occlusion in Central Line Associated Bloodstream Infections M A R C H 15, 2017

Central Line Care and Management

Intravenous Catheter Complications

The High-Flow Port Designed & Indicated for Apheresis

PATIENT CARE PLAN FOR CARE OF PERIPHERAL MIDLINE. Manufacturers specific recommendations should be noted and adhered to by individual practitioners.

Groshong* PICC and Catheters

Is it Necessary to Verify Blood Return in Monthly Port Flushes?

Emergency clamp should always be readily available in case of accidental catheter fracture

Instructions For Use. Implantable Ports. with Open-Ended and Groshong Catheters

TOTALLY IMPLANTED VENOUS ACCESS DEVICES

External Ref: Andres, D.A., et al. Catheter Pinch-Off Syndrome: Recognition and Management.

Insertion of a totally implantable vascular access device (TIVAD)

Unit 11. Objectives. Indications for IV Therapy. Intravenous Access Devices & Common IV Fluids. 3 categories. Maintenance Replacement Restoration

Groshong Catheters with Introcan Safety Peripheral IV Catheter Introducer

You have a what, inside you?

ARROW ENDURANCE. Extended Dwell Peripheral Catheter System. Rx only.

Exceptional Performance and Ease of Placement

COALINGA STATE HOSPITAL NURSING POLICY AND PROCEDURE MANUAL SECTION Treatments POLICY NUMBER: 428. Effective Date: August 31, 2006

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

Adult Venous Access Policy including the Care and Management Central Venous Access Devices (CVADs)

Guidelines for the Care and Maintenance of Intravenous Access Devices in Paediatric Patients

Complications Associated With IV Therapy

Care of a port-a-cath

If viewing a printed copy of this policy, please note it could be expired. Got to to view current policies.

The Power of Purple* Polyurethane PICC. Patient Guide. Access Systems

A Primer on Central Venous Access: Peripherally-Inserted Central Catheters, Tunneled Catheters, and Subcutaneous Ports

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

Dignity Dual Power Injectable Implantable Infusion Port INSTRUCTIONS FOR USE

You have a what, inside you?

ATI Skills Modules Checklist for Central Venous Access Devices

Experience of totally implantable venous access devices (TIV ADs) in adults with cystic fibrosis over a 13-year period

Network Policy for the Care and Management of Central Venous Access Devices (CVAD) in Adults.

Polyurethane Catheter

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

40 35

Radiology Polyurethane Catheter

Victoria Chapman BS, RN, HP (ASCP)

Polyurethane Radiology PICC

LONG-TERM HEMODIALYSIS CATHETER INSTRUCTIONS FOR USE

Split-Stream LONG-TERM HEMODIALYSIS INSTRUCTIONS FOR USE

ompanionport Speciality Medical Devices For The Veterinary Community Surgical Suggestions

Children's (Pediatric) PICC Line Placement

BARD. Instructions For Use

Aus Artificial Uretheral Sphincter Port System

PLASTIC POWER INJECTABLE IMPLANTABLE INFUSION PORT

IV Drug Delivery Systems used in Cancer Care

Central Venous Line Insertion

Occlusion Management of Central Vascular Access Devices in Adult Patients

PORTS SETTING THE STANDARD WITH A COMPREHENSIVE FAMILY OF PORTS

NexSite HD, Hemodialysis Symmetric Tip Catheter for long term use. Directions for Use. Contents

1/22/2016. Disclaimer. Disclaimer

PICC Care and Maintenance. Mary Lou Chaulk, RN

Central Venous Catheter Care and Maintenance (includes catheter troubleshooting guide)

Successful IV Starts Revised February 2014

Title: EZ-IO. Effective Date: January SOG Number: EMS Rescinds:

POWER INJECTABLE IMPLANTABLE INFUSION PORT

Portacath Insertion. Patient Information Leaflet

AV ACESS COMPLICATIONS. Ass. Prof. Dr. Habas

Complications of Central Vascular Access Devices

BioFlo PICC. with ENDEXO Technology. Directions For Use A

Xcela Hybrid PICC with PASV Valve Technology

IR Central Venous Access [ ] Pre Procedure

Skin tunnelled dialysis catheter (Tesio ) insertion

Infusion Skills Competency Checklist To be used at annual skills fair or at any other time for IV Competency

Advocate Christ Medical Center CVC Placement Certification Course

IV Therapy January, 08 Tip of the Month

Directions For Use. All directions should be read before use

Understanding your HICKMAN CATHETER

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Presentation Menu. Walk-in Slide. Full Presentation. Access. Site. Needle. Flush. Comfort. Monitor. Removing the EZ-IO catheter.

Module 10 Troubleshooting Guide

CLARIVEIN INFUSION CATHETER

Venepuncture and Cannulation. Louise Smith Clinical Nurse Specialist

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Aspira* Peritoneal Drainage Catheter

Groshong Central Venous Catheters

PARENTERAL NUTRITION: VASCUAR ACCESS DEVICE SELECTION

Patient Information Caring for your Catheter

Patient Information Caring for your Catheter

Department Policy. Code: D:PC Entity: Fairview Pharmacy Services. Department: Fairview Home Infusion. Manual: Policy and Procedure Manual

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Transcription:

Totally indwelling venous access devices Leeds MDT. April, 2008. Totally indwelling venous access devices [online]. Department of Respiratory Medicine, St James's University Hospital, UK. Available from http://www.cysticfibrosismedicine.com Introduction Totally implantable venous access devices (TIVAD) allow the administration of chemotherapy, antibiotic therapy and parenteral nutrition without limiting the concentration of the fluid or the speed of administration. The port is made of titanium, the septum of silicone. It is a closed system that is totally implanted subcutaneously (figure 1 & 2). They can be used long term (up to 2000 punctures over two years or longer) as long as they are cared for correctly. The P.A.S. Port is half the length and a third the height of the Port-A-Cath and is often preferred for cosmetic reasons (figure 1). It can be placed on the inner surface of the upper arm where it is more protected from accidental trauma and much less visible. Many adults prefer the smaller, more cosmetically acceptable P.A.S. Port to the larger Port-A-Cath (Burdon et al, 1998). Totally indwelling venous access devices (TIVADs) have proved safe and effective in overcoming problems of venous access in many patients who need regular intravenous antibiotic therapy (Kariyawasam et al, 2000; Leen et al, 2000; Munck et al, 2004; Etherington et al, 2005). It is essential that both family and professionals are familiar with the use of these devices. Figure 1. Diagramatic representation of port sites 1

Figure 2. Examples of Port-A-Cath (usually situated under the skin on chest wall) and P.A.S. Port (placed under the skin of the arm). The Ports are accessed using a special needle as shown. Practicalities of TIVAD use When it is decided that a patient will benefit from the insertion of a Port-A-Cath or P.A.S. Port, the patient and family will be contacted by the CF Nurse Specialist (CFNS) to discuss the pre- and post operative care, practicalities of caring for the device and potential complications. This meeting may take place within the hospital or at the patient s home. The patient and family will have the opportunity to view the various ports and discuss possible insertion sites. It is essential that all TIVADs are inserted by surgeons with appropriate experience. If a patient receives shared care it is vital that the local hospital is aware of the practicalities of caring for a TIVAD prior to its insertion. Follow up teaching and after care is provided by the CFNS. We recommend that P.A.S. Ports are flushed every four to six weeks and Port-A-Caths every six to eight weeks when not in use, and cared for by staff or carers who are fully trained and have expertise in their everyday care. When in use during intravenous therapy, the needles are replaced weekly. 2

Figure 3. A) P.A.S. Port sited B) P.A.S. Port in upper arm needle in situ C) P.A.S. Port protective dressing and needle in situ. General Principles Always use aseptic technique when handling the port, giving medication or taking blood samples. Only access the port when strictly necessary for the patient's treatment - the less the intravenous line is handled, the less infection risk there is. Only use the correct access needles (huber point). Always maintain a closed system to prevent infection or an air embolism. Never access the port unless you have been shown how. Never mix bolus drugs or infusions in the line, always flush with saline in between (SASH: saline, administer medication, saline, heparin). Always use a 10ml or larger syringe - smaller syringes exert high pressures and risk damaging the line. Do not exceed a pressure of 40 psi. Accessing the device Always access the port at an angle of 90 degrees to the septum (figure 2 & 3). 3

Insert the needle steadily until you feel the bottom of the port. Avoid excessive pressure on the needle once it has reached the bottom of the port. Needle length - should be long enough to reach the bottom of the port when inserted. When using the GRIPPER needle or the winged infusion set, the needle hub should be flush against the skin surface. To avoid injection into the sub-cutaneous tissue, once the septum is punctured, do not tilt or rock the needle as this may cause fluid leakage or damage to the septum. Blood sampling Withdraw at least 5ml of blood and discard. Withdraw the desired amount of blood. Immediately flush the system with 20ml of 0.9% saline. Instill 5ml of heparin (100iu/ml) establishing a heparin lock. Maintain positive pressure by clamping the extension set whilst injecting the last 0.5ml. Precautions Sports If the patient is involved with activities or occupations which involve excessive or repetitive upper extremity and/or shoulder or pectoral girdle motion they should be informed that they may increase the possibility of catheter fragmentation due to compression of the catheter between the clavicle and the first rib (The pinch-off syndrome). Medical procedures These should be restricted on the patient's arm in which the system is implanted. Don't withdraw blood from/or infuse medication into the arm in which the implanted system is located in unless you are using the port. Inadvertent puncture of the catheter will result in catheter damage. Avoid measuring the patient's blood pressure on this arm, since catheter occlusion or damage to the catheter could occur. Dressing and needle change Centres for disease control and prevention guidelines recommend changing the dressing whenever it is soiled, damp or loose. Needles should be changed every seven days. However, there is some evidence that it is safe to leave needles in for two weeks without changing it although In the Leeds Units this resulted in a significantly higher incidence of port infections (unpublished data). Trouble shooting Difficulty in flushing/infusing: Possible causes and possible solutions. Clamps may be closed. Open clamp. Catheter may be wedged in a smaller vessel or tip may be pressed against the vessel wall. Have the patient lie flat and get them to move their shoulders and rotate their head. Check flow. If resistance is still detected, blockage may be caused by drug precipitation, fibrin deposition at the catheter tip, intraluminal clot or a pinched catheter. If it is a chest placed system, the catheter may be kinked or 'pinch- off' syndrome may be occurring. Sign of this - unable to flush or aspirate fluid when the patient is sitting, but aspirates and flushes easily when lying down. Needle may not be inserted completely or may be too short to pass through the septum to the bottom 4

of the port. Insert the needle steadily through the septum or re-access the port with a longer needle. Insert the needle completely through the portal septum at a 90 degree angle to the port. Catheter may be occluded because of drug precipitate, fibrin deposition at the catheter tip or an intraluminal clot. Using a 10ml syringe, flush with 0.9% saline alternating between irrigation and aspiration. If resistance is still felt and thrombosis is suspected consider Urokinase. See Urokinase in drug database. Difficulty aspirating blood: as above. Pain Portal pocket or catheter insertion site. Check for drainage. Discharge at the insertion site. Port may be infected. Assess the patient for other signs or symptoms of infection. Vein may be irritated because of implantation technique, infusion of acidic or alkaline solutions, or infected vein related to contaminated catheters. Needle may have been accidentally pulled. Re-evaluate the site. Fluid may be infusing into the tissue. Catheter may have ruptured. Diagnosed by contrast fluid into the tissues. Undertake a portagram. Moisture at or around the insertion site Dressing may have been exposed to water or excessive perspiration. Inquire about recent activity which may explain dampness of the dressing. Extension set may be loose. Check connection between the needle extensions and tighten connectors. Needle may be displaced. Check position of the needle ensure correct needle length. Check that dressing adequate to secure the needle. Needle may have been accidentally inserted into the surrounding tissue. Septum integrity may have been compromised. Notify physician of leaking from the port. May need contrast study to confirm this. Complications Potential Complications Air embolism, artery or vein puncture, arteriovenous fistula Brachial plexus injury, cardiac arrhythmia, cardiac puncture, cardiac tamponade, catheter disconnection or fragmentation with possible embolism of catheter, catheter occlusion, catheter rupture, drug extravasion, erosion of portal/catheter through the skin and/or a blood vessel, fibrin sheath formation at the catheter tip, haematoma, haemathorax, implant rejection, infection/bacteremia/sepsis, migration of port/catheter, pneumothorax, thoracic duct injury, thromboembolism, thrombosis, thrombophebitis. These complications also apply to the Port-A-Cath system. When cared for properly, complications are rare, although patients with diabetes mellitus need to pay particular attention to aseptic technique and blood sugar control (Horn & Conway, 1993). Line infections are a recognised complication (Kariyawasam et al, 2000; Ratnalingham et al, 2002). We have reported an eight year experience of TIVAD use in our adult patients (Etherington et al, 2005). One hundred and sixty eight TIVADs were placed in 128 patients. The total number of catheter days was 161,832. The average catheter lifespan was 963 days. There were 57 catheter related complications, an overall incidence of 33.5% or one complication per 2,840 catheter days. This figure is lower than in other reports (Munck et al, 2004). The complication rates for individual problems were as follows: infection (11%), catheter blockage (7%), leakage (5%), vascular thrombosis (4%), detached and migrating catheter (4%), malposition (2%), 5

pneumothorax (1%) and fractured line (<1%). Sixty-one (36%) devices were removed for TIVAD related complications. Key points TIVADs provide safe, effective and convenient long term intravenous access There may be important complications TIVADs should be inserted by surgeons with appropriate experience If a patient receives shared care the local hospital must know how to care for a TIVAD Follow up teaching and after care should be provided by the CF Centre CFNS P.A.S. Ports should be flushed every four to six weeks and Port-A-Caths every six to eight weeks when not in use References Burdon J, Conway SP, Murchan P, et al. Five years experience of the PAS Port intravenous access system in adult cystic fibrosis. Eur Respir J 1998; 12: 212-216. Etherington C, Jones E, Peckham D, et al. A review of 168 totally implantable venous access devices [TIVAD s] inserted over an 8 year period [1995-2002] in a Regional Adult CF Centre. J Cyst Fibros 2005; 4(Suppl 1): S14. Horn CK, Conway SP. Candidaemia: risk factors in patients with cystic fibrosis who have totally implantable venous access systems. J Infect 1993; 26: 127-132. Kariyawasam HH, Pepper JR, Hodson ME, et al. Experience of totally implantable access devices (TIVADs) in adults with cystic fibrosis over a 13 year period. Respir Med 2000; 94: 1161-1165. Leen G, Greally P, Dass GL, et al. Totally implantable vascular access devices (TIVADs) in cystic fibrosis: a 10 year experience in 41 patients. Abstract Book, XIII International CF Congress, Stockholm 2000: 167. Munck A, Malbezin S, Bloch J, et al. A follow-up of 452 totally implantable vascular devices in cystic fibrosis patients. Eur Respir J 2004; 23: 430-434. Ratnalingham RA, Peckham D, Denton M, et al. Stenotrophomonas maltophilia bacteraemia in two patients with cystic fibrosis associated with totally implantable venous access devices. J Infect 2002; 44: 53-55. Copyright cysticfibrosismedicine.com 6