Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair

Similar documents
My personal experience with INCRAFT in standard and challenging cases

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

AAA: DEBATE THERE ARE NO LIMITS USING EVAR FOR AAA. 2 nd -3 rd June 2016.

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

LOWERING THE PROFILE RAISING THE BAR

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

A New EVAR Device for Infrarenal AAAs

Hostile Proximal Neck: A New Conformable EVAR Device

Challenging anatomies demand versatility.

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Access More Patients. Customize Each Seal.

Anatomical challenges in EVAR

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Durability of The Endurant Stent-Graft through 5 Years

Right Choice for Right Angles

Considerations for a Durable Repair

How effective is preservation when viewed through a clinical and economic lens?

INCRAFT system: Update from the Pivotal INSPIRATION Study

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

14F OD Ovation Abdominal Stent Graft System

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Hostile Neck During EVAR, The Role Of Endoanchores

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Talent Abdominal Stent Graft

Feasibility of aortic neck anatomy for endovascular aneurysm repair in Korean patients with abdominal aortic aneurysm

Durable outcomes. Proven performance.

Treating very short necks ( 4mm <10mm) using the Endurant stent graft + EndoAnchors: 1-year results and current insights

TriVascular Ovation Prime Abdominal Stent Graft System

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

From 1996 to 1999, a total of 1,193 patients with

Standardization of the CHEVAR procedure: How a standard approach has improved outcomes. Prof Peter Holt St George s, London

Abdominal and thoracic aneurysm repair

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Aortic stents, types, selection, tricks in deployment.

How to Categorize the Infrarenal Neck Properly? I Van Herzeele Dept. Thoracic and Vascular Surgery, Ghent University, Belgium

Improving Endograft Durability with EndoAnchors

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Nellix Endovascular System: Clinical Outcomes and Device Overview

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

FROM THE EVERYDAY TO THE EXTRAORDINARY

Management of Endoleaks

Overcoming Challenging Aortic Anatomy: from Hostile Necks to Tortuous Iliac arteries

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece

Ancillary Components with Z-Trak Introduction System

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Evolution of gender-related differences in outcome of EVAR

The Auckland Experience with the Nellix EVAS System. Andrew Holden, MBChB, FRANZCR

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX

THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Use of Aptus Heli-FX EndoAnchor implants with standard endografts to strengthen seal in hostile anatomies:

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Percutaneous Approaches to Aortic Disease in 2018

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Type 1a Endoleak in hostile neck anatomies: Endoanchor can fix it! D. Böckler University Hospital Heidelberg, Germany

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

Patient selection in Hostile Necks and how. to prevent endoleaks a word of caution

Chimney endovascular aneurysm sealing (ch-evas) for ruptured abdominal aortic aneurysms (AAA) due to type Ia endoleak following failed EVAS

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Now that Endoanchors are Approved (and paid for) We have a Durable Solution to Short Necks That s so Easy!

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Predictors of abdominal aortic aneurysm sac enlargement after EVAR Longterm results from the ENGAGE Registry

Aorfix Pythagoras US Clinical Trial:

Endoanchor-assisted TEVAR

Abdominal Aortic Aneurysm 가천대길병원 이상준

EVAR Revision Setting - How can Heli-FX EndoAnchors improve the outcomes?

Accessi Iliaci Ostili

Technique and Tips for Complicated AAA Cases with Stent Graft

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Technology. The introduction of endovascular aortic repair. cover story

Fenestrated Implantation: How I do it. Tara M Mastracci, FRCSC, FACS, FRCS, MSc Royal Free London

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED.

Influence of patient selection and IFU compliance on outcomes following EVAS

EVAR replaced standard repair in most cases. Why?

DIFFICULT ACCESS REMAINS A CONTRAINDICATION FOR EVAR APOSTOLOS K. TASSIOPOULOS, MD, FACS PROFESSOR AND CHIEF DIVISION OF VASCULAR SURGERY

The Fate of Unexpected Events Occurring in Standard EVAR

EVAS Sealing Technology: The new paradigm in AAA therapy

Transcription:

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Nilo J Mosquera, MD. Head of Department Angiology and Vascular Surgery. CHUO Hospital. Ourense. Spain

Disclosure Speaker name: Nilo J Mosquera, MD. I have the following potential conflicts of interest to report: x Consulting: Lombard Medical, Cook Medical, WL Gore, JOTEC-Cryolife, Terumo Aortic, CORDIS-Cardinal Health Employment in industry Stockholder of a healthcare company Owner of a healthcare company Other(s): Spanish National Health Service Employee I do not have any potential conflict of interest

A Closer Disclosure Report Speaker name: Nilo J Mosquera, MD. I have the following potential conflicts of interest to report: x I HAVE CONFIDENCE IN COOK AORTIC PRODUCTS

Aortic Disease Can Progress AFTER Repair Resulting in: Stent migration Endoleaks Secondary interventions Sac enlargement

Aortic anatomy and off label treatment are clearly related with faliure in durable aortic repair Schanzer A, Greenberg RK Circulation Jun 2011 n Complication Conclusion 10228 patients US multicentric data 41% patients with sac enlargement 5 years FU ONLY 42% PATIENTS ANATOMY COMPLIED WITH IFU Aortic neck angle >60º Aortic neck diameter >28mm Neck shorter than 15mm Independent risk factor during FU period Wyss TR, Greenhald RM J Vasc Surg 2011 Oct 217 patients US multicentric data Aortic neck angulation and length 53 patients had graft related complication at FU Mean 3.6y ITI had the strongest relation (hazard ratio) with compications AFTER EVAR. Neck angulation, and calcification are independent risk factors

Keys to a Durable Repair? A mantra for EVAR surgeons 1Resistance to Endoleaks and Migration 2Personalized Solutions 3Precise and Controlled Deployment 4A Seal in Healthy Tissue

1 Endoleak and Migration Resistance Resistance is based on three components Active fixation: barbs to to anchor securely in healthy tissue Radial force: stents that help support the aorta and provide graft-to-vessel apposition Columnar strength: a balance of length, stability and flexibility The long main body of the Zenith device may also play a role, as it has a higher amount of columnar support. The Zenith, a modular 3-piece bifurcated device with suprarenal support and 3 mm long fixation barbs, displayed the maximum proximal fixation capability

1 Endoleak and Migration Resistance Active fixation: barbs to to anchor securely in healthy tissue Radial force: stents that help support the aorta and provide graft-to-vessel apposition Stability and Fixation are mandatory for a durable repair Images Courtesy of Dr Jorg Tessarek, Hartmut Görtz, St. Bonifatius Hospital. Lingen.

2Personalized Solutions Devices need to be tailored to the patient s individual vasculature to help ensure the best seal. Now-a-days three piece strategy has been adopted by many EVAR device Modularity and range of sizes allows for patient manufacturers!!!! specific device configuration. I have to conclude that modular stentgrafts have overwhelming advantages, whereas the only advantage of unibody design is a reduced potential for type III endoleak. There are no components to separate. However, a properly designed modular stent-graft, with relatively short limbs and a locking mechanism between components, virtually eliminates the risk. Modularity is critical to take the advantage of the maximum sealing zone using any single milimeter from the renal to both hypogastric arteries

3Precise and Controlled Delivery Modularity is nothing without control!!! We agree every millimeter of healthy tissue in a seal zone is invaluable to a durable repair. Accurate device deployment is critical to helping to ensure a seal in healthy tissue. It is important to have some means of determining and controlling the orientation of the stent-graft. The best devices have prominent markers and a 1:1 response to externally applied torque.

4Seal in Healthy Tissue A durable EVAR requires a stable proximal aortic segment that is not wide, angulated, thrombus lined, calcified, conical-shaped or a combination of these features.

Why Durability is so important? EVAR started in the 90 s

Why Durability is so important? Do you remember 90 s?

Why Durability is so important? And 2019 is cooler! But now it is 2019!!!! We have clearly proven EVAR is feasible(at least outside UK) We have clearly proven EVAR is safer for the patient and NHS (again at least outside UK) We need to be sure that our new gold standard is durable

Is durability so critical as we think and promote? Even tested and designed endografts for regular therapy can fail. 2008 2009 2016

Is durability so critical as we think and promote? Even tested and designed endografts for regular therapy can fail. 2011: 1y FU 2012: 2y FU 2014: 4y FU 2015: 5y FU

Is durability so critical as we think and promote? Different approaches can be not so atractive in the mid-long term as they seem in short term 1y FU 3y FU

To Summarize 1. 2. 3. Aortic disease is a progressive condition It requires a durable repair Keys to a Durable Repair Didn t change: 1. Resistance to endoleaks and migration 2. Personalized Solutions 3. Precise and controlled deployment 4. A seal in healthy tissue

Zenith Alpha AAA : can durable repair be facilitated? Wider patient applicability Lower profile 3-piece modularity Complete range of sizes from 22-36 mm Can be used in conjunction with other Zenith devices, i.e. Iliac branch Easy-to-use introduction system 3 simple steps for main body deployment Retains the precision and control of previous generation devices Durable repair Active fixation, radial force and columnar strength combined in a lower profile device

Evolution of Zenith Zenith Flex Abdominal Endovascular Graft Zenith Alpha Abdominal Endovascular Graft Stainless steel Nitinol Full thickness dacron (~0.25 mm) Thin tightly woven dacron (~0.12 mm) Top cap 20 Fr Flexor 7.7 mm O.D. (32 mm stent-graft) No top cap 16 Fr Flexor 6 mm O.D. (32 mm stent-graft)

Zenith Alpha Abdominal: main features Three-piece modular system designed to accommodate varying patient anatomies Low-profile main body device: Active suprarenal fixation Gold marker at the flow divider for increased visualization under fluoroscopy Completely new low-profile leg featuring nitinol Spiral-Z technology

Zenith Alpha Abdominal Versatile system with many potential combination to adapt to Patient s anatomy Fit the graft to the Patient, not the patient to the graft!!!

Zenith Alpha Abdominal Long main bodies: maintain columnar strength in non-tortuous cases, facilitate cannulation and stable landing zone if needed in the future 70 mm 84 mm 98 mm 108 mm 118 mm 128 mm

Zenith Alpha Abdominal: long main bodies Proximal migration 3 mm above SMA Huge type I endoleak: hook dislocated 5 mm sac expansion

REDO 4 fen plan: Design 1 aditional sealing stent Above CT No room even for inverted limb bifurcated!!! JUST 1 sealing stent below renals!!!

18 months FU Type 2 Endoleak 15% sac volume reduction

Zenith Alpha Abdominal: Familiar Design Attributes Active suprarenal Fixation provides long-term migration resistance Controlled delivery Modularity

Zenith Alpha Abdominal: Improved Familiar Design Attributes Fixation barbs at 2 levels Zenith Alpha AAA Migration resistance 41.4N (Range 34.3-48.8) Source MED TS080117, PMA submission Zenith Flex 36.6 +2.4N Zenith PMA Submission

Notable Improvements Designed for a Simplified Deployment 1. New rotation handle 2. New Captor Sleeve 3. No trigger wires to manually remove 4. More intuitive system 5. Low-profile system. 16 Fr Sheath (17Fr for 36mm) 22-36 Diameters

Simplified Deployment Low-profile system for increased treatment options New rotational handle Controlled, simple & precise deployment No trigger wires to manually remove Trigger wires now remain contained within the new rotational handle

Simplified Deployment New Captor Sleeve Minimized deployment forces No top cap to retrieve Improved trackability

New features allow a Simplified Deployment: just 3 steps Low profile & Flexor Introducer Sheath enables percutaneous access and minimize vessel trauma New Captor Sleeve reduces friction and pull-back forces for controllability New rotation handle simplifies deployment while maintaining controlled precision

New Alpha Legs Spiral-Z stent design with improved performance characteristics: Lower profile introducer system (12 Fr) Nitinol z-stent material Thinner, tighter-weave fabric Increased separation force from main body Improved columnar strength in proximal seal

New Alpha Legs Conventional Z-Stents don t fit for angulation Z-Stents don t fit for angulation Techniques Spiral to minimize Z structure balances radial limb occlusion force and conformability

Flexible Low profile New Alpha Legs The risk of Low Profile Again Z-Stents don t fit for angulation 1. 2. Crossable access but poor run-off Bad planning: for final landing of the graft, landing in stenosis, steep angle, excesive oversizing This can not be prevented by any graft, technology is Techniques to minimize not magic: can lead to limb occlussion limb occlusion

how to avoid limb occlusions? Predilatation for access. Postdilatation to prevent compression. Surgical iliac conduits: (add potential complications to our procedure) Hybrid technique to improve outflow

how to avoid limb occlusions? Preoperative 72h later: limb thrombosis, thrombolisys and relining Deal with complication Clinical failure: patient at risk Increased cost for procedure

Our first experience. 76 years old patient COPD. 53 mm Dmax AAA 5-6 mm access not calcified 32 mm healthy long neck

Our first experience with Alpha: Oct 2015.

Since My first experience with Alpha: Oct 2015. 29 patients treated 17 in combination with ZBIS 11 patients completed 24 months FU No sac enlargenmet No type I or III No Stent fractures 2 non related deaths 1 limb oclusion (high grade stomach cancer dx from 6 months CT scan FU died 6 months afte dx)

Easy of use and integration: case 2.

Easy of use and integration: case 2. 37 mm Dmax right common Aneurysm 27 mm left common Dmax No Aortic Aneurysm Indication to treat?

Easy of use and integration: case 2. Referred to us by Urology dept. Need to perform radical oncologic surgery Relative to our Anaesthesia Head of Department

Easy of use and integration: case 2. 1 month FU (1 week prior to urological surgery) Discharged 24h postop (Usual PEVAR fastrack) No complications

Easy of use and integration: case 2. Both hypogastric patent Successful exclusion of Iliac aneurism

Easy of use and integration: case 2. Accurate deployment to the milimeter!!!

Easy of use and accuracy: case 3. 73 years old patient. No special comorbidities At ER admitted for abdominal pain. Stable contained ruptured AAA.

Easy of use and accuracy: case 3. Small volume paraaortic haemathoma and contrast extravasation + pain = URGENT EVAR

Easy of use and accuracy: case 3. Good infrarenal neck Left common critic stenosis Narrow aortic bifurcation Relatively calcified iliacs

Easy of use and accuracy: case 3. Postop CT FU: successful exclusion Patient discharged at Postop day 5 No Complications

Easy of use and accuracy: case 3. INFRARENAL DEPLOYMENT Accurate even in ER Accurate for regular-traineduser: User friendly device

Easy of use and accuracy: case 3. LEFT HYPO ACCURACY Accurate even in ER Accurate for regulartrained-user: User friendly device

Easy of use and accuracy: case 3. RIGHT HYPO ACCURACY Accurate even in ER Accurate for regulartrained-user: User friendly device

Easy of use and accuracy: case 3. Bifurcation after cracking Sac exclusion granted Iliac stenosis after cracking

Some Remarks from our initial experience 1. 2. 3. 4. Alpha meets profile reduction, flexibility, modularity, deliverabilty and control with traditional Flexor TM sheath: great for PEVAR improved features in a demonstrated platform. Alpha limbs even more flexible than Spiral Z User-friendly delivery system: are you totally sure these are Cook Grafts? Precise and controlled AAA system for a durable aortic repair

13 th International Symposium on Endovascular Therapeutics Status Update on Key Points & Beyond 27 th - 29 th MARCH 2019 Barcelona Spain, School of Medicine, University of Barcelona www.sitesymposium.com

Challenges in the treatment of infrarenal aneurysm & considerations for a durable repair Nilo J Mosquera, MD. Head of Department Angiology and Vascular Surgery. CHUO Hospital. Ourense. Spain