Transit time flow measurement in composite arterial revascularisation

Similar documents
Mandatory knowledge about natural history of coronary grafts. P.Sergeant P. Maureira K.U.Leuven, Belgium

Surgical Options for revascularisation P E T E R S U B R A M A N I A M

Importance of the third arterial graft in multiple arterial grafting strategies

Intraoperative Surgical Guidance and Quality Assessment

How I deploy arterial grafts

Saphenous Vein Autograft Replacement

NICE medical technology guidance assessment report overview: The VeriQ system for assessing graft flow during CABG surgery

Distal Coronary Artery Dissection Following Percutaneous Transluminal Coronary Angioplasty

Cardiac, Vascular and Transplant Surgery Quality Assessment. Intraoperative Ultrasound Imaging and TTFM

CORONARY ARTERY BYPASS GRAFTING (CABG) (Part 1) Mark Shikhman, MD, Ph.D., CSA Andrea Scott, CST

OPCAB CTSNET. 3. We are convinced of the advantages and that they are many.

TSDA ACGME Milestones

Pressure Wire Study. Fractional Flow Reserve (FFR) Nishat Jahagirdar Principal Clinical Cardiac Physiologist Kings College Hospital

Open fenestration for complicated acute aortic B dissection

CPT Code Details

Intraoperative Imaging and TTFM

The use of both the left and right internal thoracic arteries (ITAs) for revascularization

A been described after it has been used as a coronary

2 Aortic Arch Debranching UCSF Vascular Symposium /14/16. J Endovasc Ther 2002;9:suppl 2; II98 105

Non-invasive examination

Pedal Bypass With Deep Venous Arterialization:

Intraoperative Fluorescence Imaging Systems

Minimally invasive direct coronary artery bypass for left anterior descending artery revascularization analysis of 300 cases

2017 Cardiology Survival Guide

Transit-Time Blood Flow Measurements in Sequential Saphenous Coronary Artery Bypass Grafts

Postoperative AV Fistula Evaluation. Postoperative examination protocol. Postoperative AVF Protocol. Hemodialysis Access Surveillance

CASE REPORT AIR VENT OF VEIN GRAFT IN EXTRACRANIAL-INTRACRANIAL BYPASS SURGERY

Heart may be rotated but not compressed

DESCRIPTION: Percentage of patients aged 18 years and older undergoing isolated CABG surgery who received an IMA graft

Further Evaluation. Technique of Coronary Artery Bypass. of the Circular Sequential Vein Graft

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

CORONARY ARTERY BYPASS GRAFT

The goal of the hybrid approach for hypoplastic left heart

Case #1. Case #1- Possible codes. Unraveling the -59 modifier. Principles of Interventional. CASE 1: Simple angioplasty

Form 4: Coronary Evaluation

Vascular Surgery Cases: Detours. Brian F. Stull, RDMS, RVT UNC REX Healthcare Vascular Specialists

Acute dissections of the descending thoracic aorta (Debakey

Computer-Assisted Navigation on the Arrested Heart during CABG Surgery

Declaration of conflict of interest NONE

RECOMMENDED INSTRUCTIONS FOR USE

Form 4: Coronary Evaluation

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Intraoperative Fluorescence Imaging System for On-Site Assessment of Off-Pump Coronary Artery Bypass Graft

Off-pump coronary artery bypass (OPCAB) grafting has

Case Report Cardiovascular Imaging

Over the past 2 years, there has been rapid adoption

Cardiothoracic Fellow Expectations Division of Cardiac Anesthesia, Beth Israel Deaconess Medical Center

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

The most important advantage of CABG over PTCA is its

FFR: Tips and Tricks. A/Prof (Adj) Yeo Khung Keong, MBBS, FAMS, FACC, FSCAI National Heart Centre Singapore

In 1980, Bex and associates 1 first introduced the initial

CHRONIC TOTAL OCCLUSION IN PATIENTS AFTER CORONARY ARTERY BYPASS GRAFTING: A REVIEW OF POSSIBLE INTERVENTIONS AND RESULTS WITH A CASE STUDY

CRT Implantation Techniques 부천세종병원순환기내과박상원

Hybrid Coronary Artery Revascularization for Takayasu Arteritis with Major Visceral Collateral Circulation from the Left Internal Thoracic Artery

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

HD Scanning: Velocities and Volume Flow

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY

Cardiac anaesthesia. Simon May

Demonstration of Uneven. the infusion on myocardial temperature was insufficient

THORACIC SURGERY DIRECTORS ASSOCIATION BOOT CAMP

Coronary artery bypass grafting (CABG) without an

Tehnique for Using Soft, Flexible Catheter Stents in Aortocoronary Vein Bypass Operations

Competitive Blood Flow in the- Coronary Circulation Simulating Progression of Proximal Coronary Artery Disease After Saphenous Vein Bypass Surgery*

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE

Management during Reoperation of Aortocoronary Saphenous Vein Grafts with Minimal Atherosclerosis by Angiography

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

Excimer Laser for Coronary Intervention: Case Study RADIAL APPROACH: CORONARY LASER ATHERECTOMY FOR CTO OF THE LAD FOLLOWED BY PTCA NO STENTING

Disease of the aortic valve is frequently associated with

14 Valvular Stenosis

The CADScor System Frequently asked questions

IMAGES. in PAEDIATRIC CARDIOLOGY

Results of Reoperation

Competency Title: Caring for a patient with an arterial line

Accepted Manuscript. Radial artery and bilateral mammary arteries in CABG: how much is too much? Derrick Y. Tam, MD, Stephen E.

by M. Kaczmarek\ A. Nowakowski\ J. Siebert 2 and J. Rogowski 2

Radial Artery Assessment for Coronary Artery Bypass

C. Thrombus burden according to TIMI thrombus grading system

A Case for Mandatory Routine Graft Surveillance of lower extremity bypass grafts. Avishai Meyer UCHSC resident, Surgery May 8, 2006

Setting The setting was a hospital. The economic study was carried out in Australia.

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

An anterior aortoventriculoplasty, known as the Konno-

Surgery for Acquired Cardiovascular Disease

DONOR CORONARY ANGIOGRAPHY PROTOCOL

Case Report Preoperative Assessment of Anomalous Right Coronary Artery Arising from the Main Pulmonary Artery

Regardless of whether you are a vascular surgeon,

Anomalous Left Main Coronary Artery: Not Always a Simple Surgical Reimplantation

Direct Coronary Surgery Utilizing Multiple-Vein Bypass Grafts

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Atrial Septal Defects

Alessandro Della Puppa

Zachary I. Hodes, M.D., Ph.D., F.A.C.C.

For more information about how to cite these materials visit

The Role of LUTONIX 035 DCB in AV Fistula Dysfunction Management in our Practice

Coronary Circulation Under normal conditions cardiac muscle metabolism is almost exclusively aerobic depending on oxidative phosorylation to

AMMAR SERAWAN, MD. Ain Wzain Hospital. April 21, 2012 Vascular Access Study Workshop

Angiographic 5-Year Follow-up Study of Right Gastroepiploic Artery Grafts

Emergency surgery in acute coronary syndrome

Transcription:

Masters of Cardiothoracic Surgery Transit time flow measurement in composite arterial revascularisation R. John L. Brereton Cardiothoracic Surgical Unit, Royal North Shore Hospital, Sydney, Australia Correspondence to: R. John L. Brereton, FRACS. Cardiothoracic Surgical Unit, Royal North Shore Hospital, Sydney, Australia. Email: drjbadmin@bigpond.com. Submitted Aug 22, 2018. Accepted for publication Sep 10, 2018. doi: 10.21037/acs.2018.09.03 View this article at: http://dx.doi.org/10.21037/acs.2018.09.03 Introduction Neither off-pump nor on-pump coronary surgeries have good enough graft patency to forsake simple measures for improvement. In most other cardiac procedures, operative surveillance is undertaken, whether in valvular surgery or percutaneous intervention. Of the measures proposed for coronary surgery, transit-time flow measurement (TTFM) stands apart from duplex imaging, fluorescent angiography and contrast angiography as being readily implemented and non-invasive. TTFM results correlate with adverse cardiac events, graft failure, and mortality; sensible interpretative algorithms may prevent these dire consequences (1). Testing the probe The manufacturer recommends testing the probe prior to each use. Both the maximal Acoustic Coupling Index (ACI) and the zero-offset or baseline flow readout must be tested. Subtle damage to components and circuitry occurs from wear and electrostatic damage. Also, acoustic coupling may be improved by following the protocol. The probe is placed in saline within a plastic receptacle and agitated to remove bubbles. Immersed, the ACI or percentage of transmitted signal received should be greater than 90%. In practice, this recommendation is punitively stringent I find 80% more practical. The zero-offset should be minimal: the manufacturer does not provide a figure, but if greater than either 5 ml/min or 5% of expected flow, then the probe should be unplugged and replugged to the alternative Q2 channel. If the zero-offset is still non-negligible, another probe should be used. Also, I recommend holding the probe immersed, swirling the saline clockwise and then counterclockwise to verify trace deflection in both directions (Figure 1A,B). Positioning the conduit The conduit should fit comfortably and snugly but not compressed within the transducer. Under-sizing the probe will limit flow by compression and some conduit will extrude, thereby underestimating flow. Oversizing the probe leads to overestimation of flow, particularly in the presence of high flow. With tapering arterial conduits, a position of good fit can usually be found; relative freedom from clips is helpful (Figure 2A). The conduit should be placed straight within the transducer: linear and not curved, perpendicular to the handle, parallel to the back wall. Curving and angulating the conduit can overestimate flow (e.g., by pushing downwards, Figure 2B), but generally underestimates flow (2). Free flow measurement Free flow should be assessed prior to suturing each proximal and distal anastomosis. This can be assessed visually, or rigorously by direct measurement and TTFM. With some forethought, blood loss is minimized. It is unwise to construct proximal inflows for composite grafts (I, T, K, π) before verifying available flow; it is difficult to interpret competitive flow if free flow has not been assessed. Harvest skeletonized conduits allow dilatation at systemic pressure after treatment with intraluminal verapamil (5 mg per 5 ml arterial blood) and topical papaverine. After making the proximal or distal arteriotomy and inspecting

Annals of cardiothoracic surgery, Vol 7, No 5 September 2018 711 Figure 1 Probe testing. (A) TTFM probes immersed in saline in plastic container; (B) maximal acoustic coupling index and baseline zerooffset flows. TTFM, transit-time flow measurement. Figure 2 Conduit placement in probe. (A) Satisfactory vs. unsatisfactory fit and straight lie; (B) curved lie leading to flow overestimation. for spasm, measure the time to bleed a measured volume, for example 10 ml, into a syringe, the tip being occluded with bone wax. Calculate the flow from a hyperbolic flow curve. Comparison is made with the appearance and the concurrent TTFM reading (Figure 3A,B,C). Finding inadequate flow for the intended usage of course leads to revision of the operative plan. Anastomotic routine Surgeons should develop routines applicable to their particular techniques. The following routine allows a Annals of Cardiothoracic Surgery. All rights reserved. thorough evaluation of graft integrity and competitive flow in the anaortic, arterial, proximal first technique, with all distal technically side-to-side anastomoses: (I) The stabilizer is positioned straddling the coronary, taking care to obstruct neither inflow or nor outflow; (II) Small epicardiotomies are made to pass a silastic snare around the proximal vessel, fully encircling it, but not snugged (Figure 4A); (III) The coronary arteriotomy is made and native anterograde flow is assessed as strong, impaired, or weak (Figure 4B); www.annalscts.com

712 Brereton. TTFM in composite arterial revascularisation Figure 3 Estimation of free flow. (A) Free flow timed for a measured volume and assessed with TTFM; (B) hyperbola giving flow for a given time to fill to ten mis; (C) corresponding free flow trace on TTFM for mammary artery. TTFM, transit-time flow measurement. (IV) The snare is snugged to assess retrograde collateral flow as strong or weak, oxygenated or de-oxygenated; (V) A silastic shunt is passed proximally and distally; (VI) The arterial conduit is incised, to allow a side-toside anastomosis. Free graft flow is again visualised and can be measured directly and with TTFM (Figure 4C); (VII) The anastomosis is sewn, but before the knot is tied, the shunt is removed and the snare snugged, stopping native flow; (VIII) The bulldog clamp is removed from the conduit and the suture taken up and tied with unrestricted conduit flow. The graft flow is measured with TTFM; (IX) The snare is removed to allow through competitive native flow. In this manner, flow parameters are recorded without and then with competition (Figure 4D). If satisfactory, proceed to the next anastomosis; (X) After completion of all anastomoses and administration of protamine, remeasure those grafts that can be checked safely. Interpreting results Important threshold measurements have been established from clinical practice (3). As the trace appears, judge the graft in this order: (I) A graft with a pulsatility index of greater than 5 should be regarded with great concern. This correlates unarguably with adverse post-operative events, poor patency and possibly mortality. It is vital to comprehend that despite assessing a graft in terms of flow, electrocardiograph and echo, a

Annals of cardiothoracic surgery, Vol 7, No 5 September 2018 713 Figure 4 Anastomotic technique. (A) Coronary with loose proximal snare; (B) reduced anterograde flow at arteriotomy; (C) strong mammary artery free flow, shunt in left anterior descending artery; (D) snugging and releasing snare to allow comparison of graft flow with and without native competition. patient with a graft wherein the pulsatility index (PI) is greater than 5 is at greater risk of adverse outcome (Kieser et al. 2010); (II) A measured flow of less than 15 ml per minute correlates with poorer graft patency and adverse post-operative events. Although sometimes satisfactory, it is important to reconsider the function of this graft in terms of territory perfused (Kim, Kang and Lim 2005); (III) A pulsatility index of less than 3 is desirable in grafts to the left ventricular territory, including the occluded posterior descending; that is grafts not running off into right ventricular territory. If greater than 3, an explanation such as competitive flow should be sought, or patency is compromised (4); (IV) A measured flow of greater than 30 ml/min correlates with longer term graft patency; (V) Diastolic flow should be greater than 50%, Annals of Cardiothoracic Surgery. All rights reserved. probably 60% in left-sided grafts. Dealing with borderline results Interpretation of flow requires greater experience and clinical judgement than that of PI. As of yet, there is no algorithm to predict flow in a given situation. However, knowing total coronary flow, the surgeon should hypothesize a flow before measuring, considering the sizes of the conduit, the coronary and the territory perfused, in terms of the severity of the coronary stenosis. Individual clinical circumstances must be carefully understood by the surgeon. For example, if an acute left main occlusion is to be replaced by dual arterial grafts based on bilateral mammary inflows and bidirectional outflows, then the free flow must exceed and graft flow be consistent with total coronary blood flow of 250 ml/min, with an allowance to be made for the effects of acute ischaemia and intra-aortic balloon counter-pulsation. Conversely, a left mammary anastomosed www.annalscts.com

714 Brereton. TTFM in composite arterial revascularisation to a diffusely diseased left anterior descending in the distal sixth may reveal a flow of only 15 ml/min, but still provide sufficient flow reserve to reverse exercise-induced apical systolic failure. There is a series of steps which must be undertaken before taking down the anastomosis: (I) Is inflow disrupted? Check that the systemic blood pressure is satisfactory, within the levels of autoregulation, and examine the graft from origin to anastomosis for kinks or compression; (II) Is the target correct? With reference to the coronary angiogram, is the correct vessel grafted in the correct position beyond disease? (III) Is there flow restriction from adventitial bands, particularly at the inflow, or kinking at the heel, or buckling in the skip? This may be remedied without re-doing the anastomosis; (IV) Is the flow consistent with the conduit and coronary free flow? Recheck both through the cut distal end beyond the side-to-side anastomosis, or at the next graft arteriotomy; (V) If competitive flow is eliminated by snaring, does the PI reduce to satisfactory levels and flow improve? (VI) Is flow consistent with the size of the distal coronary bed, was there strong retrograde flow, should the graft be perfusing proximally and distally from the anastomosis or only distally? (VII) Is the anastomosis sound? Was every suture visualised at the intimal surface, could the outflow be narrowed, is the inflow kinked, could the other side of the conduit be picked up in the suture, were extra sutures placed, could the anastomosis be purse-stringed? Competitive flow If measured flow drops significantly with removal of the proximal native snare, competitive flow exists. Usually the PI rises concomitantly. This does not necessarily imply that the coronary stenosis is insignificant; it carries other implications. Competitive flow requires evaluation of both components: the native vessel and the conduit: (I) Is the target correct? With reference to the coronary angiogram, is the correct vessel grafted in the correct position beyond disease? For example, mistakenly grafting a diagonal branch instead of the left anterior descending will show this effect; (II) Is conduit flow limited by correctable bands, kinks, stenoses? Could the conduit be shortened to allow an anastomosis using a portion of greater radius and therefore markedly less resistance to flow? This is particularly relevant to tapering mammary arteries. Should the inflow be changed? (III) Are there excessive demands on the inflow, for example, a small mammary, or the left mammary saphenous vein T graft (wherein flow in the terminal left mammary to a moderately stenotic left anterior descending characteristically suffers competitive flow)? Snare the other limb, retest, and consider alternative inflows. Conclusions The European Association of Cardiothoracic Surgery Guidelines on Myocardial Revascularisation recommend TTFM for confirming or excluding technical graft problems. In arterial revascularisation flow measurement provides the dual advantages of verifying graft function and quantitating competitive flow. As a teaching tool, TTFM is valuable in ensuring that anastomoses performed by trainees are sound. To surgeons pursuing the development of anaortic, minimally invasive and robotic surgery, the security proffered is both indisputable and indispensable. Although not without value when used occasionally in dire ischaemic circumstances, TTFM is of most value when used both routinely and with a strict routine. It appears that most surgeons committed to off-pump arterial revascularisation use TTFM and are beginning to adopt epicardial duplex scanning. Acknowledgements Transit Time Flow Equipment has been provided by the North Shore Cardiothoracic Research and Education Fund. Footnote Conflicts of Interest: The author has no conflicts of interest to declare. References 1. Kieser TM, Rose S, Kowalewski R, et al. Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts. Eur J Cardiothorac Surg 2010;38:155-62. 2. Amin S, Werner RS, Madsen PL, et al. Intraoperative Bypass Graft Flow Measurement With Transit Time

Annals of cardiothoracic surgery, Vol 7, No 5 September 2018 715 Flowmetry: A Clinical Assessment. Ann Thorac Surg 2018;106:532-8. 3. Kieser TM. Graft quality verification in coronary artery bypass graft surgery: how, when and why? Curr Opin Cardiol 2017;32:722-36. 4. Kim KB, Kang CH, Lim C. Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts. Ann Thorac Surg 2005;80:594-8. Cite this article as: Brereton RJ. Transit time flow measurement in composite arterial revascularisation. Ann Cardiothorac Surg 2018;7(5):710-715. doi: 10.21037/ acs.2018.09.03