Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Similar documents
6/29/2012 WHAT IS IN THIS PRESENTATION? MANAGEMENT OF PRIMARY DEVICES INVESTIGATED MAJOR ISSUES WITH CARDIAC DEVICES AND FROM MED PHYS LISTSERVS

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

The clinical use of OSLD

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Acknowledgments. Introduction. Managing the Care of Radiotherapy Patients Implanted with Cardiac Devices. Outline

TG-191 The clinical use of luminescent dosimeters

8/1/2016. TG-191 The clinical use of luminescent dosimeters. Task Group Members. Scope of Report

8/2/2017. Acknowledgement. Disclaimer. How to manage radiotherapy patients with CIED from initial consult to treatment: TG203 recommendations

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Medical dosimetry using Optically Stimulated Luminescence dots and microstar readers

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

On the use of bolus for pacemaker dose measurement and reduction in radiation therapy

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Limits of Precision and Accuracy of Radiation Delivery Systems

Outlines. An Institutional Experience Managing the Care of Patients with CIEDs

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

AAPM TG 158: Measurement and calculation of doses outside the treated volume from external-beam radiation therapy

Small field diode dosimetry

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Online in vivo dosimetry in conformal radiotherapies with MOSkin detectors

Neutron dose evaluation in radiotherapy

Radiochromic film dosimetry in water phantoms

Eye plaque dosimetry verification using novel solid state devices

QA for Clinical Dosimetry with Emphasis on Clinical Trials

Neutron Measurements for Intensity Modulated Radiation Therapy

Protection of the contralateral breast during radiation therapy for breast cancer

Applications of Monte Carlo simulations to radiation dosimetry

Radiologic Units: What You Need to Know

Energy dependent response of Al 2 O 3 and its potential application in personal monitoring.

Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom

Patient dosimetry for total body irradiation using single-use MOSFET detectors

Implantable MOSFET dosimeter response to 192 Ir HDR radiation

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Peak temperature ratio of TLD glow curves to investigate the spatial variation of LET in a clinical proton beam

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

Diode calibration for dose determination in total body irradiation

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

Absorbed Dose Response in Water of Kilovoltage X-rays Beams of Radiochromic Film and Thermoluminescent for Brachytherapy Dosimetry

Verification of performance of Acuros XB Algorithm (AXB) Implemented on Eclipse Planning System

RPC s Credentialing Programs for Clinical Trials

FETUS ABSORBED DOSE EVALUATION IN HEAD AND NECK RADIOTHERAPY PROCEDURES OF PREGNANT PATIENTS

What Can Go Wrong in Radiation Treatment: Data from the RPC. Geoffrey S. Ibbott, Ph.D. and RPC Staff

Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT

Application(s) of Alanine

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Electron Beam ET - Reloaded Therapy - Reloaded

Standardization of dosimetry practices for small and large animal irradiation in radiobiological studies

BELdART-2: Moving towards safer radiotherapy. Steven Lelie 1,2, Wouter Schroeyers 1, Brigitte Reniers 1, Sonja Schreurs 1

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

INTRODUCTION. Material and Methods

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

Quality Assurance of Helical Tomotherapy Machines

IMRT QA: Point Dose Measurements or 2D Array?

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

Presented by: Rebecca M. Howell PhD, DABR, FAAPM. Results from Voluntary Independent External Peer Review of Beam Output

Normal tissue dose in pediatric VMAT Piotr Zygmanski

Dosimetry and QA of proton and heavier ion beams

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

Diode Dosimetric Characteristics Assessment for In-Vivo Dosimetry in Radiotherapy Treatment

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

A new geometric and mechanical verification device for medical LINACs

Film-based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom

Effective and efficient radiotherapy dosimetry audit: Where to next?

Level of Accuracy Practically Achievable in Radiation Therapy. David Followill and RPC staff August 6, 2013

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Additional Questions for Review 2D & 3D

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

JRPR. Prediction of Midline Dose from Entrance and Exit Dose Using OSLD Measurements for Total Body Irradiation. Original Research.

EORTC Member Facility Questionnaire

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Heterogeneity Corrections in Clinical Trials

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

The RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

The Journey of Cyberknife Commissioning

Radiation Monitoring Instruments

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Transcription:

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients Moyed Miften, PhD Professor and Chief Physicist University of Colorado Chester Reft, PhD Associate Professor University of Chicago

Acknowledgments Dimitris Mihailidis, PhD Members of AAPM TG203

Dose Estimation to Cardiac Devices Out-of-field/peripherial doses Head Scatter + Head Leakage + Internal Scatter 10 to 20 cm internal (patient) scatter dominates collimator and head scatter contribute 30 cm internal scatter and head leakage approximately equal, collimator scatter decreases > 30 cm head leakage dominates

Out-of- Field/Peripherial Doses Calculations Lookup tables/graphs Measurements In-Vivo Dosimeter Characteristics Real time Passive

Accuracy of out-of-field dose calculations RPC Study out-of-field dose Phys. Med. Biol. 55 (2010) 6999 7008 Rando Phantom Slices 20 to 25 Mantle Field AP/PA 6 MV 30 Gy delivered to isocenter Measure the dose out-of-field

TPS vs. Measurements

TPS Calculations for out-offield doses are NOT accurate Range of 3.8 11.2 cm from the field edge the TPS underestimates the dose by <40% ± 20%> As distance from field edge increases, the TPS increasingly underestimates the dose D(TPS) varies with depth, whereas D(meas) shows little variation with depth

Dose Calc: Photon out-of-filed dose

Peripheral Doses in Photon Beams

Dose Estimation: Photon out-of-filed dose 1.0 Leakage Dose decreases ~ 0.8 exponentially away from edge of field Fraction of Dose 0.6 with field size 0.4 Patient scatter Collimator scatter 1995 S. Kry, 2009 Const. 0.2with energy Const. with depth S. Kry, 2009 0.0 0 10 20 30 40 50 60 Distance from field edge (cm)

What about IMRT? 1.0 0.8 Fraction of Dose 0.6 0.4 Leakage Patient scatter Collimator scatter 0.2 0.0 0 10 20 30 40 50 60 Distance from field edge (cm) S. Kry, 2009

What about SBRT and filter-free beams?

Dose estimation: Proton out-offield dose How much dose equivalent is there? Conventional photon therapy Variations in beam Photons: parameters More Beam energy, dose near SOBP, aperture, treatment air gap field Comparable dose Variations beyond in experimental 10-20 cm designfrom field edge Size and material of phantom, manufacturer of accelerator Challenges in Dosimetry Lack of high energy response Xu, 2008, Phys Med Biol Unique machines Courtesy of S. Kry

Out-of-Field Dose Measurements Requirements: Sensitivity Energy Dependence Size TLDs / OSLDs / Diodes

Detectors used for patient measurements Film TLDs OSLDs Chip Rod Closed Radiochromic MOSFETs Ultrathin disk Opened Diode Radiographic

Examples of measured dose to Cardiac Devices Treatment Site Dose(Gy) Fraction Energy MV Technique %Dose Head & Neck Head & Neck 1.5 6 IMRT 3 1.5 6 IMRT 5 Esophagus 2.0 6 & 18 3DCRT 4 Pelvis 1.8 15 3DCRT 0.8

Real Time In Vivo Dosimeter: Diodes and MOSFET

Diodes

Temperature coeff 0.3%/ 0 C Relative Charge 1.08 1.06 1.04 1.02 1.00 0.98 QED Red preirradiated diode Error o - Co-60 = 0.29 %/ºC + - 6 MV = 0.29 %/ºC x - 15 MV = 0.29 %/ºC 0.96 0.94 10 15 20 25 30 35 40 Temperature (ºC) (Saini and Zhu, 2002)

Temperature function of time

Dose Rate Dependence 1.10 Dose Rate Dependence (n-type) 1.08 1.06 S/S(4000) 1.04 1.02 1.00 0.98 0.96 0.94 0.92 0 1 2 3 4 Instantaneous dose rate (cgy/s) x 10 4 o Isorad Gold#1 + Isorad Red (n type), Isorad 3 Gold, Veridose Green x QED Red (n type) EDP103G, x EDP203G, * Isorad p Red, QED Red (p type), QED Blue (Saini and Zhu, 2004)

Sensitivity Loss with Dose

Energy Dependence for MV Photon Beams AAPM Summer School 2009 (Saini and Zhu, 2007)

Directional Dependence

Diode as an in-vivo dosimeter Advantages: Higher relative sensitivity Quick response (1 10 s) Good mechanical stability No external bias needed Small size Smaller energy dependence of mass collision stopping power ratios (between silicon and water compared to air and water) Disadvantages: Dependence on temperature, dose rate, energy dependence, angle Require an electrical connection during irradiation

Passive In Vivo Dosimeters: Luminescent In Vivo Dosimeters TLDs and OSLDs TG-191 Recommendations on the clinical use of luminescent detectors

1.2 1 Fig. 3 Decay of DOT signal with time at room temperature 0.5 Gy 1.0 Gy 2.0 Gy 4.0 Gy Q(t)/Q(t=1min) 0.8 0.6 0.4 0.2 0 0 2 4 6 8 10 12 time (min)

40 OSLD and OSLD/Dose as a function of dose normalized to their readings at 0.25 Gy Similar response for TLDs 1.3 35 1.2 30 1.1 OSLD signal 25 20 15 10 OSLD OSLD/Dose 1 0.9 0.8 0.7 OSLD/D 5 0.6 0 0.5 0 2 4 6 8 10 Dose (Gy)

Energy dependence of OSL and TLD dosimeters 4.5 (Reading/D) relative to 6 MV 4 3.5 3 2.5 2 1.5 nanodot Dot TLD (0.15 mm) TLD (0.89 mm) 1 0 10 20 30 40 50 60 70 80 90 Effective Energy (KeV)

Energy response of TLD and OSLD detectors normalized to their response at 6 MV Modality Energy MV Equivalent Energy MeV (TLD/D) Q 6MV (OSLD/D) Q 6MV photons 0.250 0.110 1.28 1.71 photons 1.25 1.02 1.04 photons 6 2.4 1.00 1.00 photons 18 5.7 0.99 0.99 electrons 6 0.98 0.99 electrons 9 0.99 0.99 electrons 12 0.99 0.98 electrons 16 0.99 0.98 electrons 20 0.99 0.98 protons 100 1.08 0.95 protons 180 1.06 0.95 protons 250 1.08 0.96 σ ±5.5%, and ±3.8% within 1 SD for kilovoltage and megavoltage irradiations, respectively

Advantages of TLDs Wide useful dose range mrad 10 2 cgy(linearity) Dose-rate independence 0 1000 cgy/s Angular independence Reusability Readout convenience Economy Availability of different types and sizes Automation compatibility Accuracy and precision

Disadvantages of TLDs Lack of uniformity No immediate read-out Fading Light sensitivity Memory of radiation and thermal history Reader instability Loss of reading

Advantages of OSLDs Easier read-out procedure Re-read the detector Easier individual identification Optical bleaching easier than thermal annealing to remove radiation effects Angular independence Accuracy and precision

Disadvantages of OSLDs Encapsulated in light tight plastic housing Optical bleaching cannot clear all the radiation effects increased background signal Sensitivity changes with accumulated doses > 20 Gy

Comparison of Out-of-Field dose measurements with different detectors Detectors centered 10 cm from field edge of 10x10 cm 2 at a depth of 1.5 cm with no correction except for calibration 6 MV, 600 MUs, SSD=100 cm Property Ion Chamber 0.1 cc TLD-100.035x.035 x.089 cm 3 OSLD Surface Diode Table Dose (cgy) 5.8 5.6 5.6 5.0 5.4 σ(1 SD) ±0.1 ±0.2 ±0.2 ±0.1 --- D(det)/D(Ion) 1.0 0.97 0.97 0.86 0.93

Summary Measurement useful to document dose to the device and compare to TPS calculation TLDs, OSLDs and diodes are appropriate detectors for these measurements Ignore detector CFs provide an upper dose value TPS calcs are not accurate to estimate the dose to cardiac devices outside the field edge

Thank You CU Anschutz Medical Campus