Possibility of Use a Saliva for Determination Ethanol and Opiates

Similar documents
INTER- AND INTRA-INDIVIDUAL VARIATIONS OF BLOOD/BREATH AND SALIVA/BREATH RATIOS OF ALCOHOL

Screening of Antihistamine Agents (Diphenhydramine) with Blood and Urine Samples by REMEDi-HS System

Rapid and Robust Detection of THC and Its Metabolites in Blood

Application. Detection of Cannabinoids in Oral Fluid Using Inert Source GC/MS. Introduction. Authors. Abstract. Forensic Toxicology

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

[application note] Simultaneous detection and quantification of D 9 THC, 11-OH-D 9 T H C and D 9 THC-COOH in whole blood by GC tandem quadrupole MS

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

PHARMACOKINETIC STUDY OF DEXTROMETHORPHAN WITH URINARY EXCRETION

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

Forensic Analysis of Blood Alcohol Concentration

ANALYSIS OF -HYDROXYBUTYRATE (GHB) AND -BUTYROLACTONE (GBL) IN LIQUIDS PERFORMED AT NATIONAL LABORATORY OF FORENSIC SCIENCE (SKL), SWEDEN

Screening by immunoassay and confirmation & quantitation by GC-MS of buprenorphine and norbuprenorphine in urine, whole blood and serum

New Automated Screening System for the Determination of Basic Compounds in Urine by On-Line Extraction-HPLC- DAD

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Analysis of drugs of abuse in biological matrix using Time of Flight technology

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Determination of red blood cell fatty acid profiles in clinical research

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

ETHYL GLUCURONIDE DETERMINATION IN HAIR AS AN INDICATOR OF CHRONIC ALCOHOL ABUSE: A FULLY VALIDATED METHOD BY GC-EI-MS/MS

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

Agilent 7700x ICP-MS

S.C. Moldoveanu, A.G. Hudson, A. Harrison. R.J. Reynolds Tobacco Co.

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction

COMA AFTER INTAKE OF GAMMA-HYDROXYBUTYRIC ACID (GHB): TWO CASE REPORTS

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

AppNote 1/2005. Blood Alcohol Analysis Using an Automated Static Headspace Method ABSTRACT

T2007 Seattle, Washington

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

Determination of Bath Salts (Pyrovalerone Analogs) in Biological Samples

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

Determination of Amphetamine and Derivatives in Urine

Evaluation of Acetylcodeine as a Specific Marker of Illicit Heroin in Human Hair

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Development of non-aqueous single stage derivatisation method for the determination of putrescine and cadaverine using GC-MS

Fentanyl is a schedule II synthetic opiate analgesic first synthesized in 1960 that has

2.1 Determination of Ethanol (Ethyl Alcohol)

Recent Advances in the Analysis of Ethanol in Saliva: Evaluation of the QED Device

Cutoff levels for hydrocodone in a blood test

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Determination of Amantadine Residues in Chicken by LCMS-8040

Trans Fat Determination in the Industrially Processed Edible Oils By Transmission FT-IR Spectroscopy By

REPORT of ANALYSIS OF PESTICIDE RESIDUES. in SOFT DRINK SAMPLES sent by DIRECTORATE GENERAL OF HEALTH SERVICES, NEW DELHI to CFL, Mysore

Headspace Gas Chromatography to Quantitate and Identify Volatiles in Liquids

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION OF SEMI-VOLATILE SOLVENTS IN THE PHARMACEUTICAL SUBSTANCE BOSENTAN

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

FLUNITRAZEPAM Latest Revision: January 24, 2006

Determination of Clarithromycin in Human Plasma by LC-EI Tandem Mass Spectrometry: Application to Bioequivalence Study

LC-MS/MS Method for the Determination of Tenofovir from Plasma

DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Analysis of the fatty acids from Periploca sepium by GC-MS and GC-FID

Accuracy and Precision. Intra- and inter-assay accuracy and precision for both rifapentine

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Fentanyl Postmortem Redistribution: Preliminary Findings Regarding the Relationship Among Femoral Blood and Liver and Heart Tissue Concentrations

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Serum Using UHPLC-TOF

Development and Validation of RP-HPLC Method for the Estimation of Gemigliptin

Zolpidem in lethal cases

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Analysis and Quantitation of Cocaine on Currency Using GC-MS/MS. No. GCMS No. SSI-GCMS-1501

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Lowering of the Alcohol Limits for Drivers in Ireland and the Analytical Impact

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Journal of Chemical and Pharmaceutical Research

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

Procedure for Toxicology Analysis Version 4 Toxicology Unit Effective Date: 05/10/2013. Toxicology Analysis

DEVELOPMENT AND VALIDATION OF GAS CHROMATOGRAPHY METHODS FOR THE CONTROL OF VOLATILE IMPURITIES IN THE PHARMACEUTICAL SUBSTANCE DUTASTERIDE

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Application Note. Abstract. Authors. Pharmaceutical

CORESTA Recommended Method No. 84

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens

Determination of Benzodiazepines in Urine by CE-MS/MS

Determination of Opiates and Metabolites in Blood Using Electrospray LC/MS. Application Note

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

Neosolaniol. [Methods listed in the Feed Analysis Standards]

T R A I N I N G G U I D E

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Learning Objectives. Drug Testing 10/17/2012. Utilization of the urine drug screen: The good, the bad, and the ugly

Rapid Spot Tests for Detecting the Presence of Adulterants in Urine Specimens Submitted for Drug Testing

Quantitative Determination of Terpenes in Cannabis Using Headspace Solid Phase Microextraction and GC/MS

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

Transcription:

Possibility of Use a Saliva for Determination Ethanol and Opiates Wojciech Piekoszewski 1,2, Wojciech Gubała 1, Ewa Janowska 1, Janusz Pach 3, Dariusz Zuba 1 1 Institute of Forensic Research, Westerplatte 9, 31-33 Kraków, Poland 2 Department of Clinical and Industrial Toxicology, Jagiellonian University, Zlotej Jesieni 1, 31-826 Krakow, Poland 3 Toxicology Clinic, Jagiellonian University, Zlotej Jesieni 1, 31-826 Krakow, Poland Keywords Opiates, ethanol, saliva, alternative materials Abstract The research was aimed at verification of possibility to use saliva for ethanol and main opiates (morphine and codeine) determination as exact equivalent of blood samples. For the measurement of alcohol the headspace gas chromatography was used and for opiate alkaloids the gas chromatography/mass spectrometry was applied. The headspace GC method applied for ethanol determination in saliva was specific (resolution>1), shows good accuracy (recovery = 1.7%) and precision (SD = 155 g/l). Saliva and blood samples were collected from forty-nine volunteers and over 7 values of ethanol concentration were obtained. The correlation between blood and saliva concentrations of ethanol, estimated by the linear regression analysis, was very strong. Pearson correlation coefficient amounted to.94 and it was statistically significant (p<1). The concentrations of ethanol in saliva and blood were on a similar level. The mean value of saliva/blood ratio of ethanol amounted to 1.6 ±.21. The morphine and codeine concentrations were measured in serum and saliva collected from thirty-seven patients with a history of intravenous opiates use. The concentration of morphine in saliva during admission to hospital was four times lower than in serum (saliva/serum ratio.28+/-.32) but the concentration of codeine was on the similar level in both mediums (saliva/serum ratio.89+/-1.36). The concentrations of morphine and codeine in serum and saliva have shown a good correlation. Introduction Alcohol consumption is a long habit in Poland buy during the last twenty years there has been a substantial increase in illicit drug intoxication. The most frequently used drugs are cannabis and amphetamines, however its low acute toxicity cause that the major numbers of hospitalise patients are opiates poisoned. One of the most commonly abused forms of opiates in Poland is a liquid domestic product, produced from poppy straw or poppy head juice (1). For treatment of acute poisoned patients and in some forensic cases (alcohol drug and driving) the quantitative measurement of pharmacologically active xenobiotics are needed. The traditional media for these types of analyse are blood, plasma or urine. In the last ten years advances in analytical methods have enabled the determination of xenobiotics in alternative material such as sweat, saliva, and hair. The sampling of this material is not invasive and easy for collecting even from unconscious patients (2).

The aim of the present study was develop the methods for determination of main opiates and ethanol in saliva and prove its validity by comparison with determination of these xenobiotics in blood or serum. Materials and methods For the alcohol determination saliva and blood samples were collected from forty-nine volunteers (37 men and 12 women), ageing 23 6 years before and in 15-minute intervals after consumption of.7g (men) and g (women) of ethanol per kg of body weight in the form of undiluted 4 % v/v vodka.. The research performed on the studied group yielded over 5 values of ethanol concentration in saliva and blood. The alcohol concentration in studied media was measured by headspace gas chromatography (GC) using Perkin Elmer AutoSystem XL with HS 4 autosampler and flame ionisation detector (FID). Separation was achieved on a.2% Carbowax 15/Graphpack-GC column under isothermal conditions (at 1 o C). A.2 ml of saliva or blood sample was mixed with 1.8 ml of 2 g/l 2-methyl-2-propanol (internal standard-is). The samples were incubated in the autosampler for 22 min at 6 C. For the opiates studies blood and saliva samples from thirty-seven patients (29 men and 8 women) with a history of intravenous opiate use, were collected at the Toxicology Clinic in Krakow. Written informed consent was obtained from each subject in the study and blood samples were taken for diagnostic purposes. Blood (serum) and saliva samples were taken immediately after admission to the Clinic and were stored till analysis at 3 C. 1 ml samples of serum or saliva with deuterred internal standards (morphine-d3 and codeine D-3) were hydrolysed (β-glucuronidase/arylsulphatase) and deproteinised (trichloroacetic acid). For extraction, Bond Elute Certify (Varian) columns were used. Columns were conditioned with 3 ml methanol and purified with 115 M hydrochloric acid. After extracting, studied compounds were derivatised with bis (trimethylsilil) trifluoracetamide. Extracts (serum and saliva) were analysed by a GC/MS (Varian/Finnigan Mat Magnum) ion trap in full scan (5 6 m/e) and selected ion monitoring EI mode. A FSCC HP-5MS column (3 m x.25 mm x.25 µm) and helium ( ml/min) as a flow gas were used. The temperature program was: 75 C (1 min), 25 C/min up to 275 C and 275 C for 7 min. Multiplier voltage was 115 V and ionisation mode electron impact 7 ev. Full scan (5 6 m/e) and selected ion monitoring were used. The retention times were 12.5 min for morphine 12.3 min for morphine D3 and 11.43 and 11.41 min for codeine and codeine D3 respectively. Results Determination of ethanol in blood and saliva The developed gas chromatography headspace method allow for good separation of ethanol from its metabolite (acetaldehyde) and other possible co-exist in blood and saliva volatile compounds (methanol, acetone, n-propanol and iso-propanol). Linearity of the method ranged from.1 to 4. g/l of ethanol in blood and saliva. The limit of determination (LOD) was lower than 5 g/l. The recovery calculated for all calibration levels amounted to 1.7%. The precision of the method was checked using duplicate determinations of 1 randomly chosen routine samples used for ethanol level evaluation in saliva. The intra-assay precision expressed as standard deviation (SD) amounted to 16, while reproducibility (r) was 45,

and relative standard deviation (RSD) was 3.6 %. The data show the absence of systematic error when the aqueous solutions were used instead of saliva for calibration (3). Determination of morphine and codeine in serum and saliva However a lot of information concerning the determination of opiates in serum appeared in literature, information about quantification morphine and its analogies in saliva are seldom [6]. The applied chromatographic conditions allowed to separate the compound of interest from a biological background. Low limits of detection of this method were 4 ng ml -1 for morphine and 5 ng ml -1 for codeine and the limits of quantification were evaluated to be equal 14 and 15 ng ml -1 respectively. The range of quantification was from 2 to 1 ng ml -1, what covers most often observed concentrations of morphine and codeine in clinical and forensic cases. The recovery of solid phase extraction was between 5 and 6 %. The coefficients of between day s variation for measurement of morphine and codeine concentration (concentrations 4 and 9 ng ml -1 ) in serum and saliva were below 15%. Concentrations of ethanol, morphine and codeine in blood and saliva Saliva concenrtration [g/l] 1.4 1..8.4.2 Ethanol saliva = 1.77*Ethanol blood - 15 r=.94.2.4.8 1. 1.4 Blood concentration [g/l] Fig. 1. Correlation between ethanol Saliva / Blood Ratio Ethanol 2. 1.8 1.6 1.4 1..8.4.2.1.2.3.4.5.7.8.9 1. 1.1 Blood concentration [g/l] Fig.2. Relationship between saliva/blood ratios and blood concentration of ethanol. 15 Morphine saliva = 6*Morphine serum +28.8 r=.73 1.5 Morphine Saliva concentration [ng/ml] 12 9 6 3 Saliva/Serum Ratio.9.3 2 4 6 2 4 6 Fig. 3. Correlation between morphine Fig.4. Relationship between saliva/serum ratios and blood concentration of morphine.

5 Codeine 8 Codeine Saliva concentration [ng/ml] 4 3 2 1 Saliva/Serum Ratio 6 4 2 2 4 6 2 4 6 Fig. 5. Correlation between codeine Fig.6. Relationship between saliva/serum ratios and blood concentration of codeine. Discussion The correlation between blood and saliva concentrations of ethanol, morphine and codeine was estimated by the linear regression analysis, according to the least squares method. The results indicate strong correlation between ethanol concentration in blood and saliva. Pearson correlation coefficient, r, amounted to.94 and it was statistically significant (p<1). The correlation between the concentration of morphine in serum and saliva was also observed. The acceptable correlation between concentration of morphine in saliva and serum in the home-made heroine users allowed application its determination in saliva in the monitoring the clinical and forensic cases. The present of codeine in all samples containing morphine with lack of correlation between these two drugs could be caused by contamination of home-made heroine by codeine. On the other hand, a correlation between the concentration of morphine but not codeine in serum and saliva was observed. A similar relationship has been described by other authors in patients taking heroin intravenously. The concentrations of ethanol and codeine in saliva and blood (serum) are on a similar level, whereas the concentrations of morphine in saliva are about four times lower than in serum. The mean value of saliva/blood ratio of ethanol amounted to 1.6 ±.21. The saliva/serum ratio of morphine concentration was ph independent and averaged.28 ±.32 and for codeine.89 ± 1.36. The obtained values of ratio were similar as in previous literature (1, 4). The lack of influence of ph on saliva/serum ratio of studied opiates could have been caused by the imprecise method of measurement of ph applied in the experiment. References 1. Pach J., Szkolnicka B., Targosz D., Radomska M.: Substancje uzależniające w materiale Kliniki Toksykologii CM UJ w latach 1997 1999 (Substance of abuse in the practice of Toxicology Clinic Jagiellonian University in years 1997-1999). Przegląd Lekarski. 2, 2. Cone E. J.: Saliva testing for drug of abuse. Annals of New York Academy of Sciences. 1993, 694, 91.

3. Gubala W., Zuba D. Saliva as an alternative specimen for alcohol determination in the human body. Pol J Pharmacol, paper in press. 4. Cone E. J.: Testing humane hair for drug of abuse. I. Individual dose time profile of morphine and codeine in serum, saliva, urine and beard compared todrug iduced effect on pupils and behavior. J. Anal.. Toxicol. 199, 7, 1.