Introduction. Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle.

Similar documents
Evaluation of the LIAISON 25 OH Vitamin D TOTAL Assay on the new LIAISON XL analyser

Comparison between two automated chemiluminescence immunoassays for quantifying 25 (OH) vitamin D

SCIEX Vitamin D 200M Assay for the Topaz System

Standardization and Certification of the ADVIA Centaur Vitamin D Total Assay

Standardization of DiaSorin and Roche automated third generation PTH assays with an International Standard: impact on clinical populations

Discrepancy between Vitamin D Total Immunoassays due to Various Cross-reactivities

25-Hydroxyvitamin D assay performance. Graham Carter Imperial College

DBC 25-Hydroxyvitamin D

Nutrition: obtaining reliable biomarker data to study the health status of populations

Analytical Variability Among Methods for the Measurement of 25-Hydroxyvitamin D. Still Adding to the Noise

Price of High-Throughput 25-Hydroxyvitamin D Immunoassays: Frequency of Inaccurate Results

This supplementary material has been provided by the authors to give readers

Disclosure: No conflict of interests to disclose

Review. Current Methods for Routine Clinical Laboratory Testing of Vitamin D Levels. Clinical Significance

Vitamin D and its metabolites: from now and beyond

25-Hydroxy Vitamin D TOTAL (25HD) on Liaison XL

Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits

Analysis of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in Serum Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry

Performance Characteristics of Eight Estradiol Immunoassays

Cortisol Assays. The Good, The Bad and The Indifferent. David Ducroq. Cardiff and Vale ulhb WEQAS. Unit 6, Parc Tŷ Glas. Llanishen.

Keywords: albuminuria; albumin/creatinine ratio (ACR); measurements. Introduction

The VDSP is a collaborative venture that was organized in

Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography tandem mass spectrometry as a reference

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

ACCESS hstni SCIENTIFIC LITERATURE

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

Introduction. Nephrol Dial Transplant (2012) 27: doi: /ndt/gfr535 Advance Access publication 22 September 2011

Challenges of implementing JCTLM methods in the routine Clinical Laboratories. R.J. Singh, Ph.D. Mayo Clinic

25 OH Vitamin D Rapid test

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

ZIVAK TECHNOLOGIES. Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS

25OH Vitamin D Total ELISA

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

EliKine Free Thyroxine (ft4) ELISA Kit

IDEXX Catalyst SDMA Test for in-house measurement of SDMA concentration in serum from dogs and cats

Instructions For Use. IDS-iSYS 25-Hydroxy Vitamin D S IS-2700S. 1. Intended Use

Insulin (Porcine/Canine) ELISA

25 OH Vitamin D Rapid Test

A High-throughput Mass Spectrometry Multiplexed Assay to Measure Insulin and C- peptide

Ben Schöttker 1 *, Eugène H. J. M. Jansen 2, Ulrike Haug 3, Lutz Schomburg 4, Josef Köhrle 4, Hermann Brenner 1. Abstract.

Table. Analytical characteristics of commercial and research cardiac troponin I and T assays declared by the manufacturer.

Vitamin D A game changer for Clinical Laboratories

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

BNP Fragment EIA (Cat.No. BI-20852W) For the Determination of BNP Fragment in Human Samples

1,25 Dihydroxyvitamin D

Bone and Mineral. Comprehensive Menu for the Management of Bone and Mineral Related Diseases

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Female androgen profiles by MS for PCOS patients. CS Ho APCCMS 2010, Hong Kong 14 January 2010

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Bone Markers and Vascular Calcification in CKD-MBD

Comparison of Five Automated Serum and Whole Blood Folate Assays

Hexagon PSA. Design Verification. Contents

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

Serology and International units

Evaluation of the analytical performances of six measurands for thyroid functions of Mindray CL-2000i system

Vitamin D Assay in Human Serum Samples: A Review of Analysis Methods

Performance of an ultra low elution volume 96-well plate

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

25OH Vitamin D Total ELISA KAP1971

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Measuring Lipid Composition LC-MS/MS

1 PROTOCOL. Comparison Study Summary. Springs Memorial Hospital. Springs Memorial Hospital 800 W. Meeting St. Lancaster, SC (803)

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

VDSP Standardisation Issues with 25-hydroxyvitamin D Christopher Sempos, Ph.D. Adjunct Professor, University of Wisconsin-Madison

colorimetric sandwich ELISA kit datasheet

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Triiodothyronine (T3) ELISA

Endogenous antibody interference in immunoassays. Ellen Anckaert, M.D., Ph.D. Dienst Klinische Chemie en Radio-immunologie UZ Brussel

Immunoenzymetric assay for the in vitro quantitative measurement of 25- hydroxyvitamin D 2 and D 3 (25OH-D 2 and 25OH-D 3 ) in serum.

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

HPLC-UV Determination of Abacavir Sulphate in Pharmaceutical Dosage Forms

Harmonisation of Growth Hormone Assays: why, issues. MJ Ellis, Endolab, Canterbury Health Labs, May 2015

DKK-1 ELISA, Cat.No. BI For the quantitative determination of DKK-1 in human serum

Toward Standardization of Insulin Immunoassays

Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration

HbA1c enzymatic assay evaluation at AN academic

Annual Review Contents. Page 1. Introduction, scheme-wide trends, future developments Insulin C-Peptide 8-10

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Prothrombin (Human) ELISA Kit

Total Thyroxine ELISA (T4)

Correspondence should be addressed to Etienne Cavalier;

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

Measurand characteristics & reference materials for hcg

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

en US: For in-vitro diagnostic use only.

Accurate and reliable quantification of 25-hydroxy-vitamin D species by liquid. chromatography high-resolution tandem mass spectrometry

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

ELISA kit INSTRUCTION FOR USE

Forum for Collaborative HIV Research External Validation of CD4 and Viral Load Assays Paris, France June 29, 2007

Transcription:

DOI 1.1515/cclm-13-138 Clin Chem Lab Med 13; aop Etienne Cavalier*, Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi, Caroline Le Goff and Jean-Claude Souberbielle Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D Total Assay comparison with marketed automated immunoassays and a liquid chromatographytandem mass spectrometry method Abstract Background: The study was conducted to evaluate the technical and clinical performance of the VITROS Immunodiagnostic Products 25-OH Vitamin D Total Assay, and compare it with the performance of five marketed automated assays and a liquid chromatography/mass spectrometry reference method (LC-MS/MS). Methods: Three hundred patient serum samples were used to compare the correlation of the VITROS 25-OH Vitamin D Total Assay with both the other immunoassays and the LC-MS/MS method, using Passing-Bablok regression and Bland-Altman analyses. Concordance of the diagnosis of vitamin D status was calculated to test the agreement between the different assays. In addition, samples containing vitamin D2 were used to test the assay s ability to detect the D2 form of the vitamin. Results and conclusions: These results from the VITROS 25-OH Vitamin D Total Assay generally correlated well with those from most of the marketed immunoassays. Cross-reactivity of the D2 form was calculated as being close to %. Additionally, we found substantial variability in performance amongst the various assays, which suggests the need for optimisation and recalibration of commercial methods. Keywords: assay performance; bias; concordance; precision; vitamin D. *Corresponding author: Dr. Etienne Cavalier, Department of Clinical Chemistry, University of Li è ge, CHU Sart-Tilman, Domaine du Sart- Tilman, Li è ge, Belgium, E-mail: etienne.cavalier@chu.ulg.ac.be Olivier Rousselle, Nunzio Ferrante, Agnes Carlisi and Caroline Le Goff: Department of Clinical Chemistry, University of Li è ge, CHU Sart-Tilman, Domaine du Sart-Tilman, Li è ge, Belgium Jean-Claude Souberbielle: Laboratoire D Exploration Fonctionelles, Hôpital Necker-Enfants Malades, Paris, France Introduction Vitamin D is classically known for its pivotal role in calcium and bone metabolism and is critical for bone and muscle health [ 1, 2 ]. However, more recent evidence has greatly enlarged its importance in more widespread situations, especially in extraskeletal diseases such as cardiovascular disease, autoimmunity and cancer [ 3 6 ]. In the body, vitamin D is converted, first in the liver to 25-hydroxyvitamin D (25-OH D) and then to 1,25-dihydroxy-vitamin D (1,25-OH D) in the kidneys [ 7 ]. Though the latter derivative is the biologically active form, its relatively short lifetime and fluctuation in concentration has supported the intermediate product (25-OH D) as the best indicator of vitamin D status [ 8 ]. Vitamin D is present in very few foods, and its main source derives from the action of sunlight on 7- dehydrocholesterol in the epidermis, to produce the form vitamin D3. However, a related form, vitamin D2 is also ingested from plant sources as well as supplements, and both prohormones are equivalently important in defining overall vitamin status [ 9 ]. It is therefore important that any method of measurement of 25-OH D can detect both forms with equal accuracy [ 1 ]. As a result of the acceptance of an increasingly comprehensive role for vitamin D in many disease states, the demand for 25-OH D testing in the clinical laboratory has risen many fold over the last decade. This tendency accordingly has forced the transfer of methodologies from the academic, laboratory-specific level to rapid throughput platforms developed by commercial companies. However, this evolution has led to difficulties that have appeared in some of these automated assays. Problems with bias, inconsistency of results, and mutual disagreement between methodologies have arisen [ 1, 11 ], which have been clearly demonstrated using comparisons

2 Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D with results of liquid chromatography/mass spectrometry (LC-MS/MS). Recently, Ortho Clinical Diagnostics (OCD) launched an assay for 25-OH Vitamin D on the VITROS 5 Integrated System and VITROS 3 and ECi/ECiQ Immunodiagnostic Systems on the European markets. The aim of this study was to: 1) evaluate the correlation of the VITROS 25-OH Vitamin D Total Assay with five commercially available immunoassays and an LC-MS/MS method; 2) evaluate the detection of vitamin D2; and 3) assess assay precision. Materials and methods Assays The study concentrated on the performance of the VITROS 25-OH Vitamin D Total Assay. This method is a competitive, enhanced chemiluminescence immunoassay that uses low ph to release the 25-OH vitamin D in the sample from the binding protein, and uses horseradish peroxidase (HRP) labelled 25-OH vitamin D to compete with the 25-OH vitamin D in the sample for the binding of the monoclonal anti-vitamin D bound to the wells. Other commercially available assays 1) Abbott Architect 25-OH Vitamin D Assay: a delayed one-step chemiluminescence method using as capture agent a polyclonal anti-vitamin D antibody and a biotinylated vitamin D anti-biotin acridinium labelled complex. 2) Roche Elecsys Vitamin D Total Assay: a competitive electrochemiluminescence method using a ruthenium labelled vitamin D binding protein as capture agent. 3) Siemens ADVIA Centaur Vitamin D Total Assay: a competitive chemiluminescence method using a monoclonal acridinium labelled anti-25(oh) vitamin D antibody and a vitamin D analogue labelled with fluoroscein. 4) DiaSorin 25-OH Vitamin D TOTAL Assay: a competitive chemiluminescence method using an anti-25(oh)-vitamin D antibody where vitamin D and an isoluminol-labelled derivative compete for binding run on the Liaison XL platform. 5) IDS-iSYS 25-Hydroxy Vitamin D Assay: a competitive chemiluminescence method using an anti-25(oh) vitamin D antibody conjugated with acridinium, with 25-(OH) vitamin D conjugated to magnetic particles. 6) The liquid chromatography and tandem mass spectrometry (LC-MS/MS) method was carried out using the Perkin Elmer methodology as described earlier [ 11 ]. Briefly, analyses were performed using a triple quadripole TQ55 from ABSciex (Framingham, MA, USA) with Atmospheric Pressure Chemical Ionisation (APCI) source. Calibration was performed using six calibrator points [charcoal stripped human serum enriched with increasing levels of 2H 6-25(OH)D2 and 2H 6-25(OH)D3 ]. Three control levels [lyophilised serum added with increasing amount of 2 H -25(OH)D2 and 2 6 H -25(OH)D3 6 ] were used as quality controls. For each analyte specific isotopically labelled internal standards [ 2 H -25(OH)D2 for VitD and 2 3 H -25(OH)D3 for VitD ] 2 3 3 were used. To μ L of serum sample, calibrator or control, μ L of daily precipitation solution (DPS, prepared by diluting reconstituted Internal Standard 1/ with acetonitrile containing.1% of formic acid) was added. The samples were mixed for 15 min and then centrifuged at 16, g for 15 min at 4 C. Finally, 15 μ L of supernatant was transferred into a 96-well plates. The plate was loaded in the autosampler, and 5 μ L were injected into the HPLC-MS/MS system. Limit of quantification (LOQ) was 2.43 ng/ml for 25-OHD 2 and 3. ng/ml for 25-OHD 3. The intra-assay CV was < 7.2% and < 1%, and inter-assay CV was < 7.9% and < 8.9% for three concentrations between 7.5 and 78.1 ng/ml for 25-OHD 2 and 25-OHD 3, respectively. The linearity range of 25-OHD 2 and 25-OHD 3 was 2.43 to 329 and 3. to 314 ng/ml, respectively. In addition, we have controlled the calibration of the method with the NIST standards and participate to DEQAS, and the results were always on the target for LC-MS/MS users. Samples Serum samples from 3 patients were used to determine crosscorrelation and concordance between methods. These were residual laboratory samples, blinded to patient identification and information. The samples contained vitamin D concentrations, as measured by LC-MS/MS, ranging from 4.6 to 15 ng/ml. All samples were aliquoted and frozen at C until required for testing. One aliquot of each sample was tested in each assay. The ability of assays to detect vitamin D2 was tested using samples obtained in patients on D2 therapy. Statistics The correlation of the VITROS 25-OH Vitamin D Total Assay results with those of the other assays was analysed using Passing-Bablok regression. The correlation coefficient was calculated using the Pearson s correlation method. The slope and intercept are referred to in the text as proportional and constant bias, respectively. Assay biases were also calculated using the Bland-Altman plot. The same methods were used to determine agreement of all the commercial assays against LC-MS/MS. Agreement of vitamin D status between methods was calculated using concordance tables. Briefly, this involved classification of patients according to their vitamin D concentrations: < ng/ml, 3 ng/ml, 3 ng/ml and > ng/ml, and then determining the percentage of patients classified correctly by any two methods. In order to determine whether there were any methodological differences in the detection of D2, a panel of 11 samples with D2 and D3 concentrations as measured by LC-MS/MS. D2 concentrations ranged from 21 to 48.1 ng/ml (mean ± SD: 36 ± 8 ng/ml) and D3 concentrations ranged from 5 to 3 ng/ml (mean ± SD: 15 ± 8 ng/ml). The samples were tested in both, the LC-MS/MS (D3 and D2) and the VITROS, Liaison, ISYS, Architect and Elecsys assays. The percentage of 25(OH)D2 recovery was evaluated with a slightly modified protocol, as previously published in this journal [ 11, 12 ].

Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D 3 Liaison Architect isys Elecsys Centaur - -Liaison -Architect -isys -Elecsys -Centaur 1-1 - -3 8.1-1.3-28.7 - of and 3 1-1 - 15.6 -.4-16.4-3 of and Liaison 3 1-1 - -3 - -5-3 1-1 - -3 18.5-2.8-24.2 of and Architect 14.7-5. -24.7 - of and isys 3 1-1 - -3 11.6-2.9-17.4-1 of and Elecsys 3 1-1 - -3-18.4-1.2 -.8-5 of and Centaur Figure 1 Correlation and bias of vitamin D assay results from the VITROS assay against the five other commercial assays and the LC-MS method. Left column: correlation diagrams, right column, bias of results against VITROS for each assay over a span of vitamin D concentrations. y-axis (left column): VITROS vitamin D values ng/ml; x-axis (left column) vitamin D concentrations measured by each commercial assay. y-axis (right column): Bias of commercial assays against VITROS results; x-axis: mean vitamin D estimate from LC-MS/MS and assay determination for each sample.

4 Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D We evaluated the precision of the VITROS 25-OH Vitamin D Total Assay in accordance with a modified protocol based on the evaluation of precision performance CLSI EP-5A2. Six sample pools (vitamin D range of 6.57 to 12 ng/ml) were tested in triplicate for 5 days, within a single calibration period. Results Correlation of VITROS 25-OH Vitamin D Total Assay results with those from marketed assays and an LC-MS/MS method Comparison of the VITROS 25-OH Vitamin D Total Assay results on the 3 patient serum samples with all the other methods using Passing-Bablok regression and Bland-Altman plots is shown in Figure 1. Table 1 displays the correlation statistics of the VITROS 25-OH Vitamin D Total Assay results (y-axis) against the results from the other commercial vitamin D assays and the LC-MS/MS method. The results from the VITROS 25-OH Vitamin D Total Assay correlated well with those from the other assays, with slopes ranging from. to 1.6, intercept 3.5 to 4.7 ng/ml, and correlation value from.85 to.92. When the VITROS 25-OH Vitamin D Total Assay results were compared with those from the LC-MS/MS method, a negative bias was revealed. To quantify such biases, the LC-MS/MS results were also compared with those of the other assays. In Figure 2, the correlations between LC-MS/MS results and those of and the other commercial assays are depicted using Passing-Bablok regression and Bland-Altman plots. Table 2 shows the correlation statistics of the LC- MS/MS results (x-axis) against the results obtained by all the commercial Vitamin D assays. Almost all the assays were negatively biased when compared to the LC-MS/MS method, both with the proportional slopes (varying from Table 1 Correlation statistics of the VITROS 25-OH Vitamin D Total Assay results (y-axis) against the results obtained in the Perkin Elmer LC-MS/MS and the other commercial assays (x-axis). Slope (confidence limits) Intercept (confidence limits) r-value LC-MS/MS. (.76.84).5 ( 2.2 1.2).9 Architect.94 (.88 1.1).1 ( 2.1 1.6).85 Centaur.84 (.79.89) 4.7 (2.7 7.1).88 Liaison 1.6 (1. 1.12) 2.2 (.3.9.3).89 Elecsys.94 (.9.99).7 ( 2.1.9).92 isys.97 (.91 1.4) 3.5 ( 6.2 1.1).85.76 to.93) and with constant biases (intercepts varying from 6. to 3.9). The correlation coefficients ranged from.84 (Liaison) to.92 (Centaur). These results clearly demonstrated the variability in test results from different assays. To evaluate the potential impact on this discordance on the accurate determination of a patient s vitamin D status, the agreement of assignment of vitamin D status by different assays was calculated. Table 3 shows the percentage concordance between methods in the patient samples tested. The concordance between methods was variable, ranging from 65% (concordance between LC-MS/MS and Centaur) to 83% (Liaison vs. Architect). Concordance against LC-MS/MS varied from a low of 65% (Centaur) to a high of 82% (ISYS). Vitamin D2 detection Recovery of 25(OH)D2 by the Liaison, ISYS, VITROS and Roche assays was not significantly different from %. The median (95% CI) percentage recovery for each method was 12 (87 113)%, 14 (84 119)%, 16 (83 132)% and 78 (68 11)%, respectively. Even though the median of the percentage 25(OH)D2 recovery obtained with the Architect was similar to the one observed with Elecsys (78%), the 95% confidence interval was 64% to 81%, which did not encompass %. VITROS 25-OH Vitamin D Total Assay precision The precision of the assay over 5 days with six serum pools is shown in Table 4. This varied from 4.1% for the 12 ng/ml pool to 21.7% for the 6.57 ng/ml pool. Discussion The present study was designed to evaluate the technical and clinical performance of the VITROS Immunodiagnostic Products 25-OH Vitamin D Total Assay. Our results demonstrated that this new assay generally correlated well with the five other marketed vitamin D immunoassays and the LC-MS/MS method. We also examined its cross reactivity with the D2 form of the vitamin and found a satisfactory performance in this regard. The precision profile of the VITROS 25-OH Vitamin D Total Assay was comparable with those of the other commercial assays over the assay s measuring range (8 15 ng/ml).

Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D 5 Architect Centaur isys Liaison Roche - 1 1 1 1 1 1 1 1 1 1 1-1 - -3 - -5 9.1-1.6-3.3 - Architect- Centaur- isys- Liaison- Roche- - - - 14.1-7.7-29.5-1 Architect 1 8. -1 - -3 - -9.2-26.4-5 1 Centaur 1-1 - -3-13.4-5.5-24.4-5 isys 1-1 - -3 - -5 9. -1.1-29.2 - Liaison 3 1-1 - -3-1.9-7.7-26.2-5 1 Roche 1 1 Figure 2 Correlation and bias of vitamin D assay results from LC-MS/MS against the VITROS assay and five other commercial assays. Left column: correlation diagrams, right column, bias of results against LC-MS/MS for each assay over a span of vitamin D concentrations. y-axis (left column): LC-MS/MS vitamin D. Values ng/ml; x-axis (left column) vitamin D concentrations measured by each commercial assay. y-axis (right column): bias of commercial assays against LC-MS/MS; x-axis: mean vitamin D estimate from LC-MS/MS and assay determination for each sample.

6 Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D Table 2 Correlation statistics of the LC-MS/MS results (x-axis) against the results obtained by all the commercial vitamin D assays (y-axis). Slope (confidence limits) Intercept (confidence limits) r-value Architect.85 (..9).6 ( 2.6 1.4).87 Liaison.76 (.73.79) 1.4 (.3 2.6).84 Centaur.93 (.89.98) 6. ( 8.3 4.).92 isys.81 (.77.85) 3.9 (2.3 5.3).91 VITROS. (.76.84).5 ( 2.2 1.2).9 Elecsys.85 (.81.89).7 ( 2.3 1.8).91 Our results showed that there are significant methodological differences between assays as demonstrated by the different correlation statistics (significant proportional and constant biases and variable correlation coefficients) and variable inter-method concordance (from 65% to 83%). However, many of the discordances arose from readouts close to the status cut-off points. For example a value of 29 ng/ml by one method was considered as vitamin-deficient, whilst a value of 3.5 ng/ml by a different method was considered vitamin-sufficient. Whilst these small differences in the methods may put patients into different vitamin D status categories, such discordances may not affect patient management. Nevertheless, much larger discrepancies in vitamin D estimations were found, the size of which could affect patient management. Accordingly, method standardisation is urgently required in the field of vitamin D measurement. In addition, discrepancy in methods could be caused by cross-reactivity to various vitamin D2 and D3 metabolites such as the C3 epimer or by interferences from agents such as haemoglobin, human anti-mouse antibodies (HAMAs) or heterophilic antibodies. It is therefore important for clinical laboratories to be aware of the limitations of their assay. (25-OH) vitamin D determination in serum by immunoassays is a difficult task owing to the fact that it circulates in a form strongly bound to binding proteins, and it exists in different forms [25(OH)D2 and 25(OH)D3], whose relative concentrations depend on either diet or the exact Table 4 Precision of the VITROS 25-OH Vitamin D Total Assay. Pool 1 a Pool 2 Pool 3 Pool 4 Pool 5 Pool 6, ng/ml 6.57 19.6 31.7 45.6.2 11.8 % CV 21.7% 6.1% 8.4% 7.1% 6.8% 4.1% a This level is below the VITROS assay limit of quantitation (LOQ). method of vitamin D supplementation. A standardisation of the methods is thus urgently needed and is currently ongoing, through the Vitamin D Standardization Program (VDSP) [ 13, 14 ]. This work is managed by the NIH Office of Dietary Supplements (ODS) in collaboration with the CDC National Center for Environmental Health (NCEH), the National Institute of Standards and Technology (NIST) and the Ghent University. It is thus anticipated that a recalibration of the different methods will occur. When this standardisation will be eventually completed, another challenge will be to evaluate whether the clinical cut-offs currently defining vitamin D deficiency/insufficiency are still valid or need to be updated. In conclusion, the analytical performances of the VITROS assay, as demonstrated in this study, show that this method performs satisfactorily. Acknowledgments: The authors thank Ortho Clinical Diagnostics for their financial sponsorship of this study. Conflict of interest statement Authors conflict of interest disclosure: The authors stated that there are no conflicts of interest regarding the publication of this article. Research funding played no role in the study design; in the collection, analysis, and interpretation of data; in the writing of the report; or in the decision to submit the report for publication. Research funding: None declared. Employment or leadership: None declared. Honorarium: None declared. Received February 21, 12; accepted May 13, 13 Table 3 Concordance of vitamin D status between methods (expressed as %). LC-MS/MS Centaur ISYS Elecsys Architect VITROS DiaSorin XL LC-MS/MS 65 82 75 76 72 72 Centaur 65 68 74 79 78 83 ISYS 82 68 77 75 79 Elecsys 75 74 77 82 81 81 Architect 76 79 82 85 VITROS 72 78 75 81 82 DiaSorin XL 72 83 79 81 85 82

Cavalier et al.: Technical and clinical evaluation of the VITROS Immunodiagnostic Products 25-OH Vitamin D 7 References 1. Norman AW, Bouillon R. Vitamin D nutritional policy needs a vision for the future [minireview]. Exp Biol Med 1;235:134 5. 2. Rosen CJ. Clinical practice: vitamin D insufficiency. N Engl J Med 11;364:248 54. 3. Pitz S, Tomaschitz A, M ä rz W, Dreschler C, Ritz E, Zittermann A, et al. Vitamin D: cardiovascular disease and mortality (review). Clin Endocrinol 11;75:575 84. 4. Holick MF. Vitamin D: its role in cancer prevention and treatment (review). Prog Biophys Mol Biol 6;92:49 59. 5. Arnson Y, Amital H, Shoenfeld Y. Vitamin D and autoimmunity: the aetiological and therapeutic considerations. Ann Rheum Dis 7;66:1137 42. 6. Amital H, Szekanecz Z, Szücs G, Dankó K, Nagy E, Csépány T, et al. Serum concentrations of 25-OH vitamin D in patients with systemic lupus erythematosus (SLE) are inversely related to disease activity: is it time to routinely supplement patients with SLE with vitamin D? Ann Rheum Dis 1;69:1155 7. 7. Dusso AS, Brown AJ, Slatopolsky E. Vitamin D. Am J Physiol Renal Physiol 5;289:F8 28. 8. Heaney BP. Vitamin D: how much do we need and how much is too much? Osteoporosis Int ;11:553 5. 9. Holick MF, Biancuzzo RM, Chen TC, Klein EK, Young A, Bibuld D, et al. Vitamin D2 is as effective as vitamin D3 in maintaining circulating concentrations of 25-hydroxyvitamin D. J Clin Endocrinol Metab 8;93:677 81. 1. Farrell C-J, Martin S, McWhinney B, Straub I, Williams P, Herrmann M. State-of-the art vitamin D assays: a comparison of automated immunoassays with liquid chromatographytandem mass spectrometry methods. Clin Chem 12;58:531 42. 11. Le Goff C, Peeters S, Crine Y, Luks P, Souberbielle JC, Cavalier E. Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples. Clin Chem Lab Med 12;5:31 2. 12. Cavalier E, Wallace AM, Carlisi A, Chapelle JP, Delanaye P, Souberbielle JC. Cross-reactivity of 25-hydroxy vitamin D2 from different commercial immunoassays for 25-hydroxy vitamin D: an evaluation without spiked samples. Clin Chem Lab Med 11;49:555 8. 13. Thienpont LM, Stepman HC, Vesper HW. Standardization of measurements of 25-Hydroxyvitamin D3 and D2. Scand J Clin Lab Invest 12;72:41 9. 14. Sempos CT, Vesper HW, Phinney KW, Thienpont LM, Coates PM. Vitamin D status as an international issue: national surveys and the problem of standardization. Scand J Clin Lab Invest 12;72:32.