VARIANT INDOOR FUNGAL LEVELS IN RESIDENTIAL ENVIRONMENTS FOLLOWING A CLEANING INTERVENTION ON CARPETS AND SOFT FURNISHINGS

Similar documents
FUNGAL GROWTH ON BUILDING MATERIALS AND LEVELS OF AIRBORNE FUNGI IN HOMES

Mycotech Biological, Inc.

IAQ Mold Concerns. CAPT Don Hagen, USN, MS, CIH Navy Marine Corp Public Health Center

January 31, Mr. Mark LaFleur Director of Plant Operations Town of Needham 1330 Highland Avenue Needham, MA 02492

Influence of Environmental Parameters on Mold Sampling Results

MOLDS IN THE INDOOR ENVIRONMENT: Implications for Children s Health. Eugene C. Cole, DrPH Brigham Young University

Indoor Air Quality Testing. Horry County Schools

Prevalence and residential determinants of fungi within homes in Melbourne, Australia

MICROBIAL EXPOSURE AND MOLD SPECIFIC SERUM IGG LEVELS OF SYMTOMATIC SCHOOLCHILDREN

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

Certificate of Mold Analysis

Assessing Allergic Sensitivities and Allergen Exposures

EVALUATION OF THE CYCLEX IMPACTOR PHASE 2: REPORT 3

Legally Defensible Strategies for Mold Investigations

Microbiomes of the Built Environment: Homes

IAQ & MOLD AIR SAMPLING REPORT

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 25, 2013

Air fungal contamination in ten hospitals food units from Lisbon

FINAL REPORT- Part 1 & Part 2

MSES consultants, inc.

CONCENTRATIONS OF VIABLE FUNGAL SPORES ON PAPER DOCUMENTS

Dust Mite Allergy. Introduction Of the many components in house dust to which people may be allergic, the most important is the house dust mite.

A Healthy Home, LLC West Center Dr. Lakewood, CO

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Airborne Mould Sampling Moncton High School 207 Church Street Moncton, NB E1C 5A3. November 01, 2013

MSES consultants, inc.

Certificate of Mold Analysis

MICROBIOME OF ENCLOSED AIR IN SELECTED DORMITORIES IN UNIVERSITY OF PORT HARCOURT

THE EFA PROJECT: INDOOR AIR QUALITY IN EUROPEAN SCHOOLS

Certificate of Mold Analysis

This is the author s version of a work that was submitted/accepted for publication in the following source:

Certificate of Mold Analysis

Certificate of Mold Analysis (941) (941) SAMPLE REPORT

Certificate of Mold Analysis

MSES consultants, inc.

Index. Immunol Allergy Clin N Am 23 (2003) Note: Page numbers of article titles are in boldface type.

C e r t i f i c a te o f m o ld Ana l y s i s

Tape Lift and Swab Sampling of Items found at Glenwood Middle School Project #J15-876

Slide 1. Slide 2. Slide 3. School Floor Coverings and Indoor Air Quality. Professor Alan Hedge, Cornell University, 10/2001. U.S.

RE: Total Airborne Mould Spore Sampling Brookside Junior High 2239 Prospect Road, Hatchet Lake, NS

EDLab. Re: 0 Any Street, # 100 Laboratory Analysis Report Work Authorization #

Dealing With Dampness in Buildings

EXPANDED FUNGAL REPORT

Certificate of Mold Analysis

Certificate of Analysis

Certificate of Mold Analysis

test address: P R E PAR E D F OR : CalPro Inspection Group Phone Number: (800)

Poultry fungal contamination as a public health problem

Controlled Studies of Environmental Allergen Remediation in U.S. Homes: Cockroach Allergen

WHAT DOES MOLD MEAN? J&M Environmental Control Group 14 Monarch Bay Plaza, #470 Monarch Beach, CA 92629

Energy & Environmental Solutions, Inc. Mold Facts/Fiction/Who Knows

Certificate of Mold Analysis

Certificate of Analysis

MOULDS ASSOCIATED WITH MILK DEPENDING ON MACROCLIMATE AND GEOGRAPHICAL LOCATION

Comparative study of the disinfection capacity of different floor cleaning solutions on ventilated room floor

Thermotolerant filamentous fungi in belgian hospitals: 15 years of survey

NIH Public Access Author Manuscript J Occup Environ Hyg. Author manuscript; available in PMC 2008 February 7.

Health risk assessment of fungi in home environments

C E R T I F I C A T E O F M O L D A N A L Y S I S

THE USE OF DNA TESTING IN MOULD INVESTIGATIONS ANN DORTE PØRNEKI, M.SC.

TOXICOLOGY AND RISK ASSESSMENT OF MYCOTOXINS

March 01, Re: Mold Sampling. Dear Mr. Jon Lewis,

Air Sampling and Analysis for Mold in Hills Building UMass

Fungal Fragments as Indoor Air Biocontaminants

MOLD INSPECTION REPORT

Indiana University Environmental Health & Safety Beau Middaugh 2427 E. 2nd street Bloomington, IN USA (812)

Certificate of Mold Analysis

Aerobiologia Intetnltla~l Journal of Aerobiology

Certificate of Mold Analysis

Certificate of Mold Analysis

Analysis Report prepared for Quest Air

Atopy pyramid. Dr Tan Keng Leong

Berman Inspection, LLC

Texas Association of Healthcare Facilities Management December 12, 2014

Certificate of Mold Analysis

Certificate of Mold Analysis

Fungal DNA health studies and patient cases

1251 Weatherstone Ct. Reston,VA Mold Reduction Report

Mould Allergy. Patient Information

There are many varieties of particulate pollutants in our homes and offices. Ones from outside include industrial

INT J CURR SCI 2012, SHORT COMMUNICATION ISSN A study of air microflora in selected areas of Visakhapatnam

STORAGE STABILITY OF VIABLE MOULD SPORES AND ENDOTOXIN IN HOUSE DUST SAMPLES

Challenges associated with mold:

Emil J. Bardana, Jr., M.D. Oregon Health Sciences University

Certificate of Mold Analysis

Are You Safe In Your Home? The Dangers of Indoor Air Pollution

Microbiological Risk Assessment Review of B. cereus

Myrothecium: A new indoor contaminant?

April 28, Town of Wilton Board of Education 395 Danbury Road Wilton, CT 06897

Introduction: PCR Air Sampling: November 12, Carrie E Tompkins Elementary School PCR Fungi Study:

Certificate of Mold Analysis


HEALTH EFFECTS OF INDOOR FUNGAL BIOAEROSOL EXPOSURE

EDLab. Re: 0 Any Street, # 100 Laboratory Analysis Report Work Authorization #

Study of Common Air Borne Fungal Species in and Around Sugar Industries of Davangere District, Karnataka, India

Certificate of Mold Analysis

Certificate of Analysis

Current Indoor Allergen Levels of Fungi and Cats, But Not House Dust Mites, Influence Allergy and Asthma in Adults with High Dust Mite Exposure

Damp Housing and Childhood Respiratory Symptoms: The Role of Sensitization to Dust Mites and Molds

Facts about Stachybotrys chartarum and Other Molds

Transcription:

!i~ VARIANT INDOOR FUNGAL LEVELS IN RESIDENTIAL ENVIRONMENTS FOLLOWING A CLEANING INTERVENTION ON CARPETS AND SOFT FURNISHINGS CD Cheong 1 "" HG Neumeister-Kemp2, PW Dingle l and OS] Hardy2 I School ofenvrronmental Science, Murdoch University, South Street, WA 6150, Australia! School of Biological Science, Murdoch University, South Street, W A 6150, Australia ABSTRACT Changes in indoor fungal levels in residential environments were investigated over a 16-week study period following a cleaning intervention on carpets and soft furnishing. Comparable indoor and outdoor air quality and fungal levels were observed in the study homes. On average, the test homes had a 26% reduction in airborne indoor fungal levels, and a 28% reduction in corresponding outdoor levels. Data did not reveal substantial verification that the cleaning intervention resulted in reductions in indoor fungal levels, rather that the variant indoor fungal levels could be attributed to changes to fluctuations in outdoor levels. INDEX TERMS Indoor fungi, Carpets, Soft furnishings, Cleaning intervention, Outdoor levels INTRODUCTION CClrpets and soft furnishings are one of the most important reservoirs and potential sources of aeroallergens, pollen, bacteria, fungi and other components of dust in residential and commercial environments (Lewis et ai., 1998; ACGIH, 1999). Poor cleaning and maintenance leads to an accumulation of microbial contaminants, while water damage incidents provide moisture and nutritional substrates (dust, carpet material, padding/underlay, glue) for microbial organisms to proliferate to problematic levels (ACGIH, 1999). Microbial organisms may then be re-suspended into the air, during nonnal everyday activities such as walking and vacuum cleaning, leading to respiratory symptoms and diseases like asthma and sick building syndrome (Cole et al., 1994; Kemp et al., 1998; Norback et al., 1994). To avoid these problems, carpets and soft furnishings can be removed and replaced with hard surfaces like wooden floors or furniture. However, this can add considerable financial and economical burden to the building occupant and significantly change the characteristics of the horne. An alternative is to clean and treat the carpets and soft furnishings ii/situ (Elkin, 1994). Current and past studies on airbome indoor fungal levels have focussed mainly on problem buildings or the remediation of obviously mould-contaminated buildings after complaints (Koskinen et ai., 1999; Hyvarinen, 1993). Few studies have focused on environments where water or mould damage is not apparent. Even in environments where moisture or mould damage is not apparent, elevated indoor fungal presence and indoor air quality (IAQ) problems can still occur as shown in a study by Nevalainen et al. (1994). Our aim in this 16- week study was to investigate indoor fungal levels following a cleaning intervention 011 carpets and soft furnishings in the homes of asthmatic children in residential environments. Contact author email JulOm(mwn com au 1015

METHODS As part ofa larger study (Asthma 2000) on childhood asthma, asthmatic children between the ages of 6 and 11, were recmitcd from metropolitan state schools in Perth, Western Australia. Children had to have a clinical history of asthma, be living in a horne with the majority of its floor space carpeted, and its occupants to be non-smokers (Jones, 2001). Nine participants (test homes) had their carpets, bedding and soft furnishings (sofas and lounges) in all rooms of their homes professionally cleaned prior to treatment with a polymer-based antimicrobial agent. The homes offive other participants were monitored as controls. Cleaning intervention The carpets, bedding and soft furnishings in all rooms of the nine homes were thoroughly dry vacuumed with a vacuum cleaner (Filter Queen, HMI Industries) meeting the Australian Standard 3733 and equipped with a hospital grade filtration system, to trap and remove particulate soil and dust (Standards Australia, 1995). Accredited professional carpet cleaners then perfonned hot water extraction and restoration or 'steam cleaning', to suspend soils and dirt with detergents and hot water in a solution, which was then removed with wet vacuuming. Industrial sized air movers (Sahara Turbo Drier Model, Drieaz) were then used to facilitate the quick drying of the damp materials. Once dry, a light application of an antimicrobial agent (RS1957) was applied wet with an airless pressure-type spray applicator (Unijet Model, Spraying Systems Inc.), onto the surface of the carpets, bedding and soft furnishings in a sweeping motion from left to right, then right to left. This was again dried with the assistance ofthe air movers. Occupants were told to keep off the carpets, bedding and soft furnishings for 12 hours or until drying was completed. Thereafter, homeowners maintained their nonnal household cleaning practices for the duration of the study period. Monitoring protocol Baseline air samples were obtained from the subject's bedroom, prior to the cleaning intervention. The air quality parameters measured during the baseline-monitoring phase included pmticulate matter (particles per cubic centimeter), temperature, relative humidity (RH) and airborne fungal levels. Outdoor air quality parameters were concurrently monitored for comparison with indoor levels. The nine homes with the cleaning intervention and the five control homes were monitored a further three times over the 16-week study period. Monitoring was conducted in the bedroom of each asthmatic child. The level of activity was kept at a minimum at each sampling frame. Airborne viable indoor fungal spore sampling was conducted in the middle ofthe room with two N-6 Andersen multi-hole impactor samplers, placed on beds, for two minutes at a flow rate of28.3 L min-i. In order to enumerate as wide as possible spectrum of fungi, duplicate side-by-side sampling was conducted for malt extract agar (MEA - DIFCO) (broad spectrum medium) and Diehloran 18% Glucose Agar (DG-18- Oxoid) (specific for xerophilic fungi ~ low water activity, a w ) plates. Both media were. amended with Chloramphenicol (4 ml Chloramphenicol in 6 ml acetone per I litre agar media - Oxoid) to limit bacterial growth. Outdoor air fungal samples were collected concurrently ~o~ comparison with indoor levels. Culture plates were incubated for five days in the dark at 22 C1 C) and 30%RH (3%RH) in a climate controlled incubation room. Once incubated, the total concentration of viable culturable fungal colonies was determined and reported as colony fanning units per cubic meter of air (CFU m-\ 1016

r Particulate matter was measured with a P-Trak Ultrafine Particle Counter (Model 8525, TSI IDC.), capable of detecting particles in the size range 0.02 to 1.0 micrometer. The concentration range for the P-Trak was 0 to 5 x 10 5 particles per cubic meter (particles m- 3 ). Temperature and relative humidity were measured with an indoor humidity gauge thennometer (accuracy ~ 1 C, ~5%RH) (Model 63-1013, IntcrTAN Inc.). Statistical analysis Analysis of indoor air quality data collected for this study was performed using the MS Excel VS.O Statistical Add-ins Package. Paired t-tests assuming equal variance (P) and alpha = 0.05 and ANOVA calculations were performed for analysis of variance. Pearson product moment correlation analysis was used to investigate associations or relationships between the mean air temperature, relative humidity, particulate matter and total fungal colony forming units. RESULTS Air quality parameters Results of air quality monitoring showed comparable indoor and outdoor air quality levels (Table 1). There was a 22.4% and 24.6% reduction in conesponding airborne indoor and outdoor particulate matter (particles m- 3 ) 16 weeks after the cleaning intervention. Particulate levels were always higher indoors than outdoors. Over this time, temperatures increased by 2.3 0 C indoors and 3.7 C outdoors whereas relative humidity decreased 1.9% indoors and increased 1.1% outdoors (Table 1). Weak but statistically significant correlations were observed between indoor fungal levels and with temperature (r ~ - 0.279, P ~ 0.02) and relative humidity (r ~ 0.285, P ~ 0.025). There was a strong negative and statistically significant correlation between airborne particulate matter (particles em-') and indoor fungal levels (CPU Ill-') (r ~ - 0.984, P ~ 0.021). Table 1. Indoor (In) and Outdoor (Out) air quality parameters before (Bt) and 16 weeks after (At) cleaning intervention Air Temperature Relative humidity Airborne particulate (,e) (%RH) matter (tj~rticles m-jl Bf Af Bf Af Bf Af Bf Af Bf Af Bf Af In In Out Out In In Out Out In In Out Out Mean 16.7 19 16.6 20.3 61.3 59.4 54.6 55.7 2.52 1.96 2.15 1.62 % chan.ge 13.8 22.3-3.1 2.0-22 -25 Min 13 16 13 17 36 46 34 43 0.42 0.45 0.62 0.32 Max 20 20 20 25 81 77 81 73 5.85 8.30 4.53 4.59 Airborne fuugal colony forming units Large fluctuations in airborne indoor fungal levels were observed in both the test homes and control homes over the l6-week study period. Reductions of between 14.8% and 88.1 %, to increases of up to 1410% in indoor fungal levels were observed in the test homes over the duration of the study period (Table 3). On average, there was a 25.9% reduction in indoor fungal levels in the homes with the cleaning interventions, compared with a 19.6% increase in the control homes (Table 2). Average outdoor fungal levels at both the test homes and control homes yielded reductions of28.3% and 50.4% respectively. 1017

Table 2. Average airborne fungal colony fanning units Timeperiod Test homes Control homes (CFUm- 3 I (CFUm- 3 Indoor Outdoor Indoor Outdoor Before cleaning intervention 516 720 295 481 16 weeks after cleaning intervention 382 516 353 238 Percent~ge change - 25.9% - 28.3% + 19.6% - 50.4% Large increases ("hot spots") in indoor fungal colony fonning units was observed in two test homes, H3 after 16 weeks (2808 CFU m- 3 compared to 742 CFU m- 3 ) and in H7 after 6 weeks (5333 CFU m- 3 compared to 353 CFU m- 3 ) (Table 3). Con'esponding outdoor fungal levels recorded reductions of3001o & 98%, respectively. Fungal samples from the two homes were differentiated and showed that the large increase in the indoor sample in H3 was made up of 99% Penicillium species (2790 CFU m- 3 ) and in H7, 95% Cladosporium species (5138 CFU m 3). Corresponding outdoor fungal samples for H3 was made up of 38% Cladosporium, 15% Penicillium, 12% Botrytis and the rest made up of Aspergillus, Alternaria, and sterile species, whilst H7 was made up of 50% Cladosporium, 25% Alternaria and 25% Botrytis species. No further attempt was made to investigate the source of the microbial proliferation. Table 3. Indoor (in) and outdoor (out) fungal levels (CFU m- 3 ) and percentage (%) change in the nine test homes (HI -H9) before (B), at 2 days, 6 weeks and 16 weeks after the cleaning intervention HI HI H2 H2 H3 in out in Out in Before 1183 1801 335 477 742 % change 0 0 0 0 0 2 days 212 388 159 194 88 % change -82-78 -53-59 -88 6 weeks 159 388 159 194 477 % change -87-78 -52-59 -35 16 weeks 653 583 335 265 2808 % chan~e -45-68 0.0-44 279 H3 H4 out in 653 335 0 0 971 247 49-26 371 88-43 -73 459 124-30 -63 H4 Out 406 0 971 65 388-4.3 65.2-61 H5 H5 in out 477 1077 0 0 406 406-15 -17 335 441-30 -13 212 371-56 -13 H6 H6 H7 H7 H8 in out in out in Before 230 424 353 441 777 % change 0 0 0 0 0 2 days 300 353 300 124 547 % change 31-17 -15-72 -30 6 weeks 300 371 5333 141 265 % change 30.8-13 1410-98 -66 16 weeks 124 371 494 406 865 %chan&e -47-12 40-8 11 H8 H9 out in 583 436 0 0 441 247-24 -43 353 371-39 -15 1130 247 94-43 H9 Out 553 0 212-62 371-33 459-17 * % change is compared to initial baseline ("Before") level Only a small subset of samples was differentiated for the test homes. Prior to the cleaning intervention, the most conunon indoor fungi found in the test homes were Penicillium spp., yeast species, Cladosporium spp., Alternaria spp. and Botrytis sp. Sixteen weeks after the cleaning intervention the most common fungi in the indoor air were yeasts, Penicillium spp and Cladosporium spp., with corresponding outdoor samples showing Cladosporil1m spp. and fenicillium spp., the most common outdoor fungi. 1018 <

OISCUSSION C J11parable indoor and outdoor air quality levels were observed in the study homes for rticulate matter, temperature, relative humidity and fungal colony fonning units. Many P~dies have indicated that temperature, relative humidity and suspended particulate matter ~n be used as possible predictors of indoor fungal levels (Dham1age et al., 1999; Fang et al., 1998; Pasanen e~ al., ~ 991). Resul~s from the current study support these previo~s studi~s: confirming relatt~nships between mdoor fungal numbers and temperature, relattve humidity and airborne parttculate matter. Data collected in this study did not reveal substantial verification or evidence that the cleaning intervention resulted in reductions in indoor fungal levels, rather that the variant indoor fungal levels could be attributed to changes to fluctuations in outdoor levels. Numerous studies have shown outdoor air as the main source of fungi in indoor air and a major contributor of external contamination to the levels of indoor fungi (Kemp et al., 2001; Verhoeff et al., 1992), Our results agreed with these observations with six of the eight homes on Day 2, which yielded lower indoor fungal levels, corresponding to similar declines in outdoor levels. This study showed similar decreases in both average airborne outdoor fungal levels (28%) and corresponding airborne indoor fungal levels (26%) in the majority of the test homes, Fungal differentiation of a subset of indoor and outdoor samples (16 weeks after the cleaning intervention) from the test homes also showed similar fungal species composition (Penicillium spp. and Cladosporium spp.) in both the indoor and outdoor environment. The study raised the possibility that the cleaning intervention itself may have resulted in J1licrobial proliferation with tv.'o homes recording substantial increases, not immediately attributable to outdoor sources. A possible explanation of the increased microbial levels could be attributed to moisture availability due to cleaning with wet methods and inefficient drying in certain areas resulting in "hot spots" of potential microbial proliferation, One of the acknowledged limitations in this study is the failure to investigate such point sources or "hot spots" in more detail. Fungal differentiation oftest versus control homes as well as both indoor versus outdoor samples could have provided further information as to the source of the fungi indoors. The immediate question of which influence is more significant; the outdoor constraint or the influence of cleaning interventions on indoor levels, or indeed prevailing point sources within the homes, still remains for current and future research. REFERENCES American Conference of Governmental Industrial Hygienists (ACGIH). 1999. Bioaerosols: Assessment and Control. ACGIH, Cincinnati, Ohio, USA Cole, E,C., Foarde, K.K., Leese, K,E., Green, D,L., Franke, D.L. and Berry, M,A. 1994. Assessment of fungi in carpeted environments. In: Health Implications of Fungi in Indoor EnVironments, Samson, R.A., Flannigan, B., Flannigan, M.E., Verhoeff, A.P., Adan, O.e.G. and Hoekstra, E.S., eds.. Air Quality Monographs. Vol 2. Elsevier, Amsterdam, pp 103-128. Dharmage, S., Bailey, M., Raven, 1., Mitakakis, T., Thien, F., Forbes, A., Guest, D., Abramson, M. and Walters, E.H. 1999. Prevalence and residential determinants of fungi within homes in Melbourne, Australia, Clinical and Experimental Allergy, 29, 1481-1489. Etkin, D.S., 1994. Biocontaminants in Indoor Environments. indoor Air Quality Update. Cutter Infonnation Corp, Arlington, MA, Fang, L., Clausen, G. and Fanger, P.O. 1998. Impact ofternperature and relative humidity on perception of indoor air quality. indoor Air 8,80-90. 1019

Hyvarinen, A, Reponen, T, Husman, T, Ruuskanen, J. and Nevalainen, A. 1993. Characterizing mould problem buildings - concentrations and flora of viable fungi. Indoor Air 3, pp 337-343. Jones, J. 2001. Improving asthma symptoms through better cleaning practices. Honours Thesis. School of Environmental Science. Murdoch University. Western Australia. Kemp, P.C, Dingle, P. and Neumeister, H.G. 1998. Particulate Matter lnterventionstudy: A Causal Factor of Building-Related Symptoms in an older Building. Indoor Air 8, 153-171. Kemp, P.C, Neumeister-Kemp, H.G., Lysek, G. and Murray, F. 2001. Survival and growth of microorganisms on air filtration media during initial loading. Atmospheric Environment. (in print) Koskinen, 0, Husman, T, Meklin, T, Nevaiainen, A. 1999. Adverse health effects in children associated with moisture and mould observations in houses. international Journal of Environmental Health Research, Vol. 9, pp 143-156. Lewis, RD., Breysse, P.N., Lees, P.S.J., Diener-West, M., Hamilton, R.G. and Eggleston, P. 1998. Factors affecting the retention of dust mite allergen on carpet. AIHA Journal 59, 606-613. Nevalainen, A, Hyvarinen, A, Pasanen, AL. and Reponen, T. 1994. Fungi and bacteria in normal and mouldy dwellings. In: Health Implications of Fungi in Indoor Environments, Samson, R.A, Flannigan, B., Flannigan, M.E., Verhoeff, A.P., Adan, O.CG. and Hoekstra, E.S., eds. Air Quality Monographs. Vol 2. Elsevier, Amsterdam, pp 163-168. Norback, D., Edling, C and Wieslander, G. 1994. Asthma symptoms and the sick building syndrome. The significance of microorganisms in the indoor environment. In: Health Implications of Fungi in indoor Environments, Samson, R.A, Flannigan, B., Flannigan, M.E., Verhoeff, AP., Adan, O.e.G. and Hoekstra, B.S., eds. Air Quality Monographs. Vol 2. Elsevier, Amsterdam, pp 229-239. Pasanen, AL., Pasanen, P., Jantunen, M.1. and Kalliokoski, P. 1991. Significance of air humidity and air velocity for fungal spore release into the air. Atmospheric Environment 25 (A), 459-462. Verhoeff, AP., van Wijnen, lh., Brunekreef, B., Fischer, P., van Reenen-Hoeskstra, E.S. and Sampson, R.A. 1992. Presence of viable mould propagules in indoor air in relation to house damp and outdoor air. Allergy 47, 83-9l. lo20