Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Similar documents
A high performance mass spec designed just for chemists

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

More structural information with MS n

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Lipidomic Analysis by UPLC-QTOF MS

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Analyzing Phenyl Ureas and Carbamates with HPLC/API-MS. Presented by Chen-Kai Meng, Ph.D. Applications Chemist

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Vitamin D3 and related compounds by ESI and APCI

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

CAMAG TLC-MS INTERFACE

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Agilent 1260 Infinity Analytical SFC System

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Methods in Mass Spectrometry. Dr. Noam Tal Laboratory of Mass Spectrometry School of Chemistry, Tel Aviv University

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

LC-Based Lipidomics Analysis on QTRAP Instruments

Edgar Naegele. Abstract

QuickSplitTM Flow Splitters

2D-LC as an Automated Desalting Tool for MSD Analysis

Mass Spectrometry at the Laboratory of Food Chemistry. Edwin Bakx Laboratory of Food Chemistry Wageningen University

Characterization of an Unknown Compound Using the LTQ Orbitrap

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Authors. Abstract. Introduction. Environmental

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

MSQ. Hardware. Document No Revision 02 October 2003

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

IC-MS Environmental Applications - Water Testing. Application Notebook

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Comparison of a UPLC Method across Multiple UHPLC Systems

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

The New 6495 Triple Quadrupole LC/MS

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Agilent s LC/MS Portfolio and Applications Examples

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Introduction to LC/MS/MS

Agilent 1220 Infinity LC System Performance Specifications

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Polymer Additive Analysis by EI and APCI

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Agilent 7700x ICP-MS

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Making your LC Method Compatible with Mass Spectrometry

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Sample Concentration and Analysis of Human Hormones in Drinking Water

California TOF/QTOF Users Meetings: MS Settings. Jim Lau, Agilent Technologies.

Chapter 6 IDENTIFICATION AND CHARACTERIZATION OF FLAVONOIDS BY HPLC AND LC-MS/MS ANALYSIS

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

SUPPLEMENTARY INFORMATION

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Sue D Antonio Application Chemist Cedar Creek, TX

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Separation and Quantitation of Oxysterol Compounds Using LC-MS/MS. Liquid Chromatography Mass Spectrometry SSI-LCMS-082

Sample Preparation is Key

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Supporting Information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Ion Suppression Minimized in LC/MSD

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Transcription:

Single Quadrupole Compact Mass Spectrometer for Liquid Sample YL INSTRUMENT CO., LTD.

YL9900 MS quickly provides essential information and improves the chemist's workflow. Mordern organic labs have become automated, yet real-time mass assays remain just out of reach. YL9900 MS solves this! YL 9900 MS is the smartest instrument for performing a mass spec solution, if you are a biopharmaceutical company, academic teaching/research lab or any industry requiring mass assays. Positive and negative ions analysis ESI / APCI switchable with minimal effort, optional installation The first mass spec which fits in a fume hood with the sash closed Easy access to the YL9900 MS : 10 connectors located on the front of the instrument 8 I/O connectors, USB port and computer connector Integrated solutions : - FIA - LC or UPLC - Flash - Reaction monitoring - TLC An inviting interface with powerful depth - Mass Express TM, Data Express TM. YL-Clarity both LC and MS with MS Extension only.

Elegant stand - alone Integrated solution FIA/MS Isocratic 10 ~ 500 μl/min Methanol of Acetonitrile with 0.1% Formin Acid 6-port Direct Injection Valve Guard Column To ESI of APCI Ion Source Real-time reaction monitoring : Understand kinetics and reach intelligent quench decisions A mass detector which can be integrated into existing HPLC and UPLC systems Replacing expensive mass spectrometers purchased from another era LC or UPLC/MS Column Autosampler HPLC or UPLC system 50 μl/min to 2 ml/ min eluent Contact Closure O/P Optional splitting T for flows above 500 μl/min Contact Closure I/P To Waste A B Flow Reactor Flow synthesis/ms Rheodyne MRA 100 Mass Rate Attenuator Valve Collection Vial On-line flow chemistry reaction monitoring 1 ~ 200 ml/min Reaction mixture Isocratic Make up 0.1 ~ 1.0 ml/min Methanol or Acetonitrile with 0.1 % Formic Acid 0.1 ~ 1.0 ml/min Mass directed or Mass confirmed, UV directed fraction collection from normal phase flash chromatography, prep LC and SFC. Column Isocratic Prep scale LC or NPFC with Fraction Collector Return to UV UV I/P 10 ~ 100 ml/min Gradient 300 μl/min To ESI Mass Spectrometer Analog O/P Rheodyne MRA 100 Splitting Valve Mass Rate Attenuator 300 μl/min Acetonitrile or IPA or Ethanol with 0.1% Formic Acid Flash/MS 1 ~ 200 μl/min 80/20 Acetonitrile or Methanol with 0.1% Formic Acid 6 port valve Piston Head Sealing Face Mass confirmation of flash fraction : Eliminate TLC plate spotting or 2nd guessing UV peaks and TLC spots Isocratic TLC Plate TLC/MS

Simple! We focused in the minimum steps and most efficient range of motion required for decision-bearing answer. Ultimate confidence! You can export cdf and csv files and you have thought of all possible options for data archiving and interpretation. The YL9900 MS uses a pressurize calibrant delivery system for both positive and negative tuning mixes which are placed inside. You can also set parameters manually. Tetramethylammonium, 74.10 Tetrabutylammonium, 242.28 Tetradecylammonium, 578.66 Tetraoctadecylammonium, 1027.16 10 pmol/μl infusion of Quaternary Amine Mix abundant peaks are tetra alkyl ammonium ions You can overcome poor resolution with UV detector or other detectors. Selective ion mode gives you a high selectivity for all individual chemicals. Sensitivity 100pg Reserpine FIA - Full Scan Mode 100-1000 m/z XIC 608.8-609.8 S/N 140:1 Sensitivity 10pg Reserpine FIA - SIM Mode, 609.28 m/z TIC 10 pg Reserpine SIM. datx S/N 115:1 Whether your application is FIA, Flash, LC, UPLC or flow reaction monitoring, our data acquisition and workflow approaches are the same. Time in seconds FIA / MS After 5 min Room Tem Reactant Product After 30 min Room Temp Reactant Product After 100 min Room Temp Reactant Product Minutes:Seconds TLC / MS Peptide Product No Product 4 YL-Clarity integrates HPLC/MS control of all operation parameters 4 You can use the optional NIST Library and User Library 4 It is designed for 21 CFR Part 11 Compliance and fully compatible with all Windows OS.

4 4 4 4 4 Unrivalled expertise in mass spectrometry just for the chemist Electrospray Ionization Atmospheric Pressure Chemical Ionization Ionization technique: Patentpending design Heated Desolvation Gas Nebulization Gas Electrospray Probe Liquid Introduction Nebulization Gas Heated Drying Gas APCI Probe Corona Discharge Pin Heated Capillary Inlet Detector Heated Capillary Inlet Detector Hexapole Ion- Transfer Region Quadrupole Analyzer Dynode Hexapole Ion- Transfer Region Quadrupole Analyzer Dynode ~2 mbar ~2 mbar ~5 x 10-3 mbar ~5 x 10-6 mbar ~5 x 10-3 mbar ~5 x 10-6 mbar Boost Drag Turbo Molecular Electron multiplier Boost Drag Turbo Molecular Electron multiplier To Roughing To Roughing

The smartest mass spec designed just for Chemists! Specification YL9900 MS Mass Analyzer Mass Range Scan Speed Ion Source Polarity HPLC Flow Rate Resolution Sensitivity Accuracy Stability Gas Gas Consumption Weight Single Quadrupole 10-1,200 m/z 5,000 m/z/s ESI / APCI Option Positive / Negative 10-500 μl/min 0.5-0.7 m/s FWHM at 1,000 m/z/s 10 pg reserpine FIA - 5 μl injection at 100 μl/min 100:1 S/N RMS with SIM of m/z 609.28 100 pg reserpine FIA - 5 μl injection at 100 μl/min 100:1 S/N RMS with full-scan acquisition from m/z 100 to m/z 1,200 ± 0.1 m/z 0.1 m/z over 12 hour N2, 98 %, 60 psi 8 L/min 32 kg Dimensions H W D, mm 660 280 560 Power Consumption Software Warranty Max. 300 VA MS Max. 550 VA Rotary pump Mass Express TM / Data Express TM YL-Clarity 1 year The idea makes ideal! KOREA MADE Young Lin Bldg., 899-6, Hogye-dong, Anyang, 431-836, Korea TEL: 82-31-428-8700 / FAX: 82-31-428-8779 E-mail: export@younglin.com Homepage: : www.younglin.com These Products are manufactured by Young Lin ISO 9001-certified facility that is periodically audited by the registering body to ensure compliance