cara I-Bridge Manual cara makes life so easy

Similar documents
cara I-Bridge Torque for Prosthetic Screws and overview of Screwdrivers

cara I-Bridge Overview of platforms and systems es life so easy

cara I-Butment regular/angled They fit like real teeth.

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

Bridging the Gap Between Original and Multi-Platform Systems.

Pala Mix & Match DS Artificial teeth for CAD/CAM process

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

» For multi-unit restorations -

cement-retained single crowns using cementable abutments

More than Abutments. catalogue

screw-retained crown using the Laser-Lok Easy Ti temp abutment

cara I-Bridge Overview of platforms and systems es life so easy

screw-retained crown using a PEEK temporary abutment

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

/NobelReplace Ø4.3mm. /NobelReplace Ø3.5mm

Catalog. etkon ident Compatibles perfected. From a partner you can trust _etkon_iDent_Catalogue_nordic indd :56:11

Multi-unit abutment open tray technique using the direct pick-up coping

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

NobelProcera Product Overview

_ Instructions for multi-unit screw-retained restorations

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Legacy Prosthetic Catalog

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Watson Dental Lab Fixed Hybrid Protocol

Multi-unit abutment closed tray technique using the indirect transfer coping

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

Quick start Prosthetics

open tray technique using the direct pick-up coping

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

closed tray technique using the indirect transfer coping

GC Manufacturing Europe

introduction to BioHorizons prosthetics

High-end solution STEP-BY-STEP USER GUIDE

How something small, can make such a big difference!! Your best choice in overdenture

CHECK-UP Determination of Impression type & Method after implant placement

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Multi-unit abutment bar overdenture

Prosthodontic Procedure

Multi-unit abutment hybrid or fixed-detachable screw-retained restoration

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

verification jig fabrication

OD Secure chairside pick-up using existing denture

Leading material offering and application range. Straumann CARES CADCAM

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS

Product Information. cara I-Products A perfect match for your implant. Giving a hand to oral health.

Straumann Variobase Family. More than treatment flexibility. Driving efficiency in your lab.

fabricating a custom impression coping using the closed tray technique

PRE-MILLED BLANK COMPLETE SOLUTION

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Product Information. Straumann CARES Scan & Shape Turn into digital.

IMPRESSION PROCEDURES TRAINING MANUAL

ball abutment overdenture: chairside pick-up using existing denture

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Restorative Manual. April


SS Implant System 2013 PROSTHETIC PROCEDURE

internal Impression Technique Guide Internal Implant System

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Hex-Lock Abutment System. Restorative Manual

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

BIOTECH DENTAL GROUP, 2.0 DENTAL OFFICE PARTNER.

TABLE OF CONTENTS P. 4-5 P. 6-7 P. 8-9 P P P P

NobelEsthetics. Introduction page 4. Temporary implant restorations page 6. Solutions for existing teeth page 14. Final implant restorations page 26

24 About us Sincerely. Content SCREW SELECTION GUIDE

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Product Information. Straumann CARES Scan & Shape Turning into digital solutions.

INTRODUCTION. Why Choose Cortex Prosthetics?

Stock Prosthetic Guide 2014

User Manual Complete Prosthetic Kit (CPK)

CAD-CAM SOLUTIONS CAD-CAM SOLUTIONS

CAD/CAM Prosthetic Solutions

NARROW DIAMETER implant

Element-Z Screw-Retained Hybrid

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

internal impression quick reference guide

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

WHERE CREATIVITY MEETS TECHNOLOGY E CREATECH EXCELLENCE. State-of-the-art technology for your prostheses

cara i500 Simply impress(ion)ing.

INSTRUCTIONS FOR USE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

prosthetic technique manual

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Restoring Straumann implants. with Locator abutments.

US Implant System 2013 PROSTHETIC PROCEDURE

the way to straumann cares abutments

GUIDED SURGERY TECHNIQUE

ELSNER SYSTEM OVERVIEW Revolutionary solutions for your implant prosthetic problems

abutment selection guide

For technical assistance: Tel Working time: 8.30 am pm

Transcription:

cara I-Bridge Manual cara makes life so easy

Welcome to cara I-Bridge In this document you will learn more about cara I-Bridge and what you need to consider before you order our product. This manual is a detailed describtion of the process. Still if you have any further questions, you are welcome to contact Customer Service on +46 42 453 07 00. You can also find more information on our website at www.cara-kulzer.com cara I-Bridge Cobalt Chrome CoCr cara I-Bridge Titanium Ti cara I-Bridge Zirconia Zr Laser-sintered or milled framework cobalt chrome that complies with the standard EN ISO22674 Simple to grind and to veneer with ceramic Production time: 5 days Fully-milled framework Grade2: ISO 5832-2, ASTM F67 An excellent choice for biocompatibility Production time: 3 days Fully-milled framework Tissue-friendly uncoloured zirconia according to standard EN 6872 Up to six components with a maximum of three fi xtures Max. height of prototype: 20 mm Production time: 5 days Not all products are available in all markets. 2

cara I-Bridge gives you many options to choose from. cara I-Bridge is a good value implant bridge that is precision-manufactured and homogenous, and comes with straight or angled screw channels. It has a documented fit and is produced by using the latest CAD/CAM technology. cara I-Bridge is available as regular (straight screw channels) and angled (angled screw channels), and comes in cobalt chrome, titanium and zirconia for the market s leading implant systems. With our unique, patented cara I-Bridge angled, you can angle the screw channels up to 20. Angled screw channels enable you to place the implant in the best position possible without having to pay for costly abutments. This makes cara I-Bridge both financially and aesthetically favourable. For more information about our different systems, please see overview of platforms and systems at www.cara-kulzer.com This prosthetic solution not only gives you the greatest choice, it is also covered by the most comprehensive warranty on the market. Heraeus Kulzer provides a warranty card for every cara I-Bridge that meets the production requirements. This means that the patient receives a new cara I-Bridge as a replacement if the bridge shows any defects caused in the production process at Heraeus Kulzer. 3

How to order and make a cara I-Bridge In this section we will explain how to order and prepare your cara I-Bridge. When you come to the option to angle the screw channel, you can choose to use either cara I-Flex or the Angulation Guide to make the cara I-Bridge angled template. Dentists Take an impression with the original system s impression copings (except for Switch level, see information box to the right). Send the impression to your dental laboratory and order a cara I-Bridge regular or angled. The production time is three working days for titanium bridges and five working days for bridges made out of cobalt chrome or zirconia. You also need to take into account the delivery time and the laboratory s working time. cara I-Bridge regular is supplied with prosthetic screws, whereas cara I-Bridge angled is supplied with prosthetic screws and laboratory screws. Dental Technicians You place your orders for cara I-Bridge by using the cara Meeting Point software, which you can download from the Heraeus Kulzer website, by using our cara app, cara mobile Meeting Point, or direct through your 3Shape system. Files in STL format from open scanners can be uploaded at cara Meeting Point. If you want to order components to produce models and prototypes, please contact Customer Service. For cara I-Bridge angled you need either a cara I-Flex for each implant including an Access guide or the Angulation Guide to ensure that you do not exceed the maximum screw channel angle. Please refer to the process on the following pages. Additional requirements for cara I-Bridge angled (Switch level). Screw the switch onto the implant with a 0.048 hex screwdriver (refer to our screwdriver guide on page 11) using manual power (15 Ncm). Make an impression of the switches using the switch impression copings and send to the dental technician. Screw the healing spacer sleeves onto the switches. The order tool: cara Meeting Point 4

Process for cara I-Bridge regular This is a manual describing how to make your cara I-Bridge. The process follows the description of cara I-Bridge regular. When you come to the option to angle the screw channel, you can choose to use either cara I-Flex or the Angulation Guide to make the cara I-Bridge angled template. 1 2 3 Mount the analogues onto the impression. Make sure that the analogues are firmly attached to the impression material. Apply soft tissue replacement approx. 1 2 mm on the analogue. This enables us to visually inspect the fit. Enclose the impression and pour in the plaster. 4 5 6 Make a bite template using cylinders and connect them with acrylic resin. 7 8 Set up the teeth with the help of cylinders and connect them with acrylic resin. Take a pre-mould of the teeth set-up by using putty mass so that you can reposition it on the model. Û Please refer to page 8 when using cara I-Flex and an Access guide. Using the pre-mould, make an acrylic template that shows exactly how your I-Bridge should look like. Û Please refer to page 6 when using the Angulation Guide. Order at www.cara-kulzer.com Place your order for cara I-Bridge regular. Send the model and template to Heraeus Kulzer in Helsingborg, Sweden. 5

Process for cara I-Bridge angled Angulation Guide 1 2 3 Insert the fixed rod of the Angulation Guide into the temporary cylinder until it reaches the screw seating. NOTE: The cylinder should not contain a screw. Point the movable rod on the template. The angle between the two rods is 20. This is the maximum possible angulation for cara I-Bridge angled. 4 5 6 You can choose the position of the screw channel exit hole anywhere between the cylinder rod and the pointed rod. Indicate the desired angle wax. Repeat the process for all screw channels that require angulation. 7 8 9 The raised indicators are read by the scanner to show the desired position of the screw hole. If one of the screw channels is angled, the entire bridge is supplied with seatings and screws for angled screw channels. This enables you to use the same screwdriver for all screws. If the angle exceeds 20, the screw channel will be repositioned by a dental technician at Heraeus Kulzer to the furthest possible angle in the same direction. 6

Process for cara I-Bridge angled Angulation Guide 10 11 12 The holes in the temporary cylinders do not need to be covered. Those are covered automatically in the preparatory program. It is possible to cover the screw holes if you wish to do so for design purposes, do not leave the screw beneath. However, at least one hole must remain open. Order at www.cara-kulzer.com Place your order for cara I-Bridge angled. Send the model and template to Heraeus Kulzer in Helsingborg, Sweden. cara angulation guide 7

Process for cara I-Bridge angled cara I-Flex and Access Guides 1 2 3 Make a pre-mould (impression) of the teeth set-up by using putty mass. Screw cara I-Flex (ball screws and spacer sleeves) on the analogues and clip on the Access guides, note the right position for the spacers. Use the cara I-Flex with Access guides for orientation of the desired angle (max. 20 ) using the pre-mould as an index. 4 5 6 To fix the position of the Access guide and protect the ball from acrylic resin, place some wax between the Access guide and the analogue. The Access guides are encased in plastic and an acrylic template is formed. The Access guides are ground down to the level of the template. It is important that the holes of the Access guides are not covered with acrylic resin. 7 8 9 The maximum construction height is 25 mm for titanium and cobalt chrome. The maximum height for zirconia is 20 mm. When cara I-Flex is used for small bridge sections on two implants or when the implants are in a line, the prototype must be fixed with cara I-Flex on the model with wax. Order at www.cara-kulzer.com Place your order for cara I-Bridge angled. Send the model and template to Heraeus Kulzer in Helsingborg, Sweden. 8

Final steps in the process ceramic firing 1 2 3 Grind over the bridge by using a crosscut tungsten carbide burr. Afterwards sand-blust the framework with Al 2 O 3 appr. 125 µm and 3 4 bar pressure. Û Keep attention to the implant connection Apply opaque to the framework in accordance with the manufacturer s instructions. Veneer the cara I-Bridge as usual. TIPP: Use Oxid-Stop on the implant connection for avoiding oxidation! 4 Other important information. cara I-Bridge is screwed into position in the mouth using the enclosed prosthetic screws and the torque stated on the packaging. Only the prosthetic screws and screwdriver supplied and are designed for cara I-Bridge angled should be used with cara I-Bridge angled. Also read our detailed information about cara I-Bridge when placing your order. Heraeus Kulzer does not assume liability for printing errors. Ceramic veneering is completed in accordance with the manufacturer s instructions. cara I-Bridge new connection You can now order cara I-Bridge for all implant systems and in several different materials. Contact Customer Service on +46 42 453 07 00 for more information about how to order a cara I-Bridge new connection. www.cara-i-bridge.com 9

Points to remember on delivery of cara I-Bridge Working with cara I-Bridge is simple and flexible. Please use the points below for help. However, this is not a list of instructions; you can use other working methods if you wish. Provisional delivery Check the bridge design and confi rm that it fi ts the model and the patient s mouth. The implant bridge is made to fi t perfectly. It is important to clean the implant and all components before you attach them with screws. Use a torque wrench. Start with the implant that is most angled. Then tighten the bridge screws in the implant in a non-linear sequence (preferably far from each other and preferably contralaterally). Tighten the screws alternately and press down on the opposite side of the bridge as you fasten each screw. Check the occlusion, articulation etc. Screw on the bridge, almost to the torque that is given on the screw packaging. Place something into the hole to protect the head of the screw, e.g. Unitape. Teflon band which is packed down into the hole. Silicon tubing, 2 mm diameter. Cut to a suitable length. Cured impression material from the syringe, such as purple Flexitime. However, it may be difficult to extract all the material if the holes are deep. Do not apply impression mass directly onto the screws! Impression mass is difficult to remove. It might surround the screw, which can cause problems when the screw has to be removed. Finally, cover the holes with temporary light-cured filling material. If you want, you can fill the holes with impression material after you have made sure that the screw heads are protected. You need: Torque wrench cara Manual Torque Wrench can be used for angled bridges. You can also use a cara Manual Torque Wrench for a straight bridge, or you can use the torque wrench that is specific to your implant system. Screwdriver for angled screw channel cara I-Bridge Angulation Screwdriver. The screwdriver is available in the following lengths: 18, 24, 29, 32, 35 mm. Screwdriver for straight screw channel Heraeus Kulzer sells screwdrivers that fit most original systems. Use these or a screwdriver from the implant manufacturer. Final delivery Check the function, occlusion, oral hygiene, comfort, etc. Using the torque wrench, retighten the screws to the recommended torque for each screw. Protect the screw heads with the Tefl on band or silicon tubing, then fill each screw hole with composite. Take an X-ray and check the fi tting. If the patient has bruxism or is a severe tooth grinder, measures should be taken to minimise the risk of any future problems with the implant and cara I-Bridge. Give the patient a Heraeus Kulzer warranty card. Record the cara I-Bridge ID number in the patient records. Heraeus Kulzer saves all fi les and can easily access information about your bridge should you have any questions. 10

Overview of cara I-Bridge screwdrivers Our unique implant bridges are easy to attach with screws. Based on the system you are interested in, look at the table below to see which screwdriver you can use for each implant and cara I-Bridge. Implant system Compatible Screwdriver no. Straumann 1, 2 Astra Tech (Abutment Level) 3, 4 BioHorizons 3, 4 Nobel Biocare 5, 6 Brånemark System 7, 8, 9 cara Switch 7, 8, 9 cara I-Bridge angled, all systems 10, 11, 12, 13, 14 Other systems Original cara I-Bridge regular S. nr.* Article no. Product name** Grip Compatible with 1 39901861 Screwdriver 20 mm Torx Straumann 2 39901862 Screwdriver 32 mm Torx Straumann 3 39901871 Screwdriver 20 mm Hex 0.050 Universal (t.ex. Astra Tech, BioHorizons ) 4 39901872 Screwdriver 32 mm Hex 0.050 Universal (t.ex. Astra Tech, BioHorizons ) 5 39901881 Screwdriver 20 mm Unigrip Nobel Biocare 6 39901882 Screwdriver 32 mm Unigrip Nobel Biocare 7 39905000 Screwdriver 18 mm Hex 0.048 Universal (Brånemark System / cara Switch) 8 39905001 Screwdriver 24 mm Hex 0.048 Universal (Brånemark System / cara Switch) 9 39905011 Screwdriver 32 mm Hex 0.048 Universal (Brånemark System / cara Switch) cara I-Bridge angled S. nr.* Article no. Product name** Grip Compatible with 10 39901854 Angulation Screwdriver 18 mm Flexgrip cara I-Bridge angled 11 39901855 Angulation Screwdriver 24 mm Flexgrip cara I-Bridge angled 12 39901851 Angulation Screwdriver 29 mm Flexgrip cara I-Bridge angled 13 39901852 Angulation Screwdriver 32 mm Flexgrip cara I-Bridge angled 14 39901853 Angulation Screwdriver 35 mm Flexgrip cara I-Bridge angled Handle and torque wrench Article no. Product name Compatible with 39901850 Screwdriver handle RA-grip Universal 39905005 Manual Torque Wrench 10 32 Ncm Universal * Screwdriver no. ** The overall length of the screwdriver is shown. The screwdriver handle for the screwdriver must be ordered separately. Brånemark System and NobelReplace are trademarks of the Nobel Biocare group. Straumann is a trademarks of Straumann Group. Astra Tech OsseoSpeed is a trademark of Dentsply Friadent Group. BioHorizons is a registered trademark of BioHorizons Implant Systems Inc, USA. 11

Our specialists in the field will be pleased to provide you with information and service. ORDER & CUSTOMER SERVICE +46 42 453 07 00 TECHNICAL HOTLINE +46 42 453 07 00 GIVE US A CALL! www.cara-kulzer.com In compliance with the European Directive 93/42/EEC, our medical devices carry a CE mark or custom design depending on their classification. Contact in Nordic & Baltic States Heraeus Kulzer Nordic AB Box 22237 250 24 Helsingborg Phone: +46 42 453 07 00 Fax: +46 42 453 07 01 cara-service@kulzer-dental.com www.cara-kulzer.se Contact in Germany Heraeus Kulzer GmbH Grüner Weg 11 63450 Hanau Phone: +49 800 437 25 22 Fax: +49 800 437 23 29 cadcam@kulzer-dental.com www.cara-kulzer.de Contact in Australia Heraeus Dental Australia PTY LTD Rydecorp, Unit 6 2 Eden Park Drive Macquarie Park, NSW 2113 Phone: +61 2 8422 6100 sales.mckulzer@kulzer-dental.com www.cara-kulzer.com Contact in United Kingdom Heraeus Kulzer Limited Heraeus House Albert Road Newbury RG14 1DL Phone: +44 1635 30500 Fax: +44 1635 524622 www.cara-kulzer.com W11301 GB 140321 ORT