Objectives. Explanation of Radiation Dose Terminology 10/9/2018. What are these lines?

Similar documents
Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

FDA Executive Summary

Breast Tomosynthesis An additional screening tool in the fight against breast cancer

WHAT TO EXPECT. Breast Tomosynthesis An additional screening tool in the fight against breast cancer HOLOGIC. The Women's Health Company

Update of Digital Breast Tomosynthesis. Susan Orel Roth, MD

CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

Since its introduction in 2000, digital mammography has become

Breast tomosynthesis reduces radiologist performance variability compared to digital mammography

Implementation of a New Tomosynthesis Program: A Physicists Perspective

Radiation Dose in Pediatric Imaging

Breast Tomosynthesis

Breast Tomosynthesis

WHAT TO EXPECT. Genius 3D Mammography Exam. The most exciting advancement in mammography in over 30 years

Radiation related cancer risk & benefit/risk assessment for screening procedures

Improving Reading Time of Digital Breast Tomosynthesis with Concurrent Computer Aided Detection

Everyday Radiation. David D. Dixon HDT Rally Hutchinson, KS October 15, 2014

TOMOSYNTHESIS: WORTH ALL THE HYPE?

Radiation Dosimetry in Digital Breast Tomosynthesis. March, 2015 William J. O Connel, Dr. Ph, Senior Medical Physicist

Digital Breast Tomosynthesis from a first idea to clinical routine

TOMOSYNTHESIS. Daniela Bernardi. U.O. Senologia Clinica e Screening mammografico APSS Trento, Italy

Sources of Data of Stochastic Effects of Radiation. Michael K O Connor, Ph.D. Dept. of Radiology, Mayo Clinic

Breast Tomosynthesis. What is breast tomosynthesis?

EARLY DETECTION: MAMMOGRAPHY AND SONOGRAPHY

Digital Breast Tomosynthesis

The Linear No-Threshold Model (LNT): Made to Be Tested, Made to Be Questioned. Richard C. Miller, PhD Associate Professor The University of Chicago

Clinical Policy: Digital Breast Tomosynthesis Reference Number: CP.MP.90

Radiologic Units: What You Need to Know

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

Everyday Radiation. David D. Dixon HDT Rally Hutchinson, KS October 13, 2015

#46: DIGITAL TOMOSYNTHESIS: What is the Data Really Showing? TERMS (AKA) WHAT IS TOMOSYNTHESIS? 3/3/2014. Digital breast tomosynthesis =

Radiation Dose Specification

Advice Statement 005/18 April 2018

Mammography. What is Mammography?

Tomosynthesis and breast imaging update. Dr Michael J Michell Consultant Radiologist King's College Hospital NHS Foundation Trust

Estimating Risk of Low Radiation Doses (from AAPM 2013) María Marteinsdóttir Nordic Trauma,

Volume 14 - Issue 3, Matrix

Introduction To Nuclear Power Module 3: Understanding Radiation and Its Effects

Where does the estimate of 29,000 cancers come from? Based on Table 12D from BEIR VII, + risk estimates for 56,900,000 patients

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

Why radiation protection matters?

3D Mammography. The most exciting advancement in mammography in over 30 years

Fundamentals of Breast Tomosynthesis

9/3/2015. New Mammographic Modality Training. Mammographer. Qualified Radiologic Technologist. Tomosynthesis Training

Challenges to Delivery of High Quality Mammography

Dose reduction in Hologic Selenia FFDM units through AEC optimization, without compromising diagnostic image quality.

Does the synthesised digital mammography (3D-DM) change the ACR density pattern?

Contrast-Enhanced Digital Mammography

Background Radiation in U.S. ~ msv/yr msv/yr ~0.02 ~0.02 msv msv/day /day (~2 m rem/day) mrem/day) NCRP 4

WOMEN S HEALTH SOLUTIONS. The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 8000

Mammography limitations. Clinical performance of digital breast tomosynthesis compared to digital mammography: blinded multi-reader study

WHAT TO EXPECT. Genius 3D MAMMOGRAPHY Exam. The most exciting advancement in mammography in over 30 years

Ionizing Radiation. Michael J. Vala, CHP. Bristol-Myers Squibb

Corporate Medical Policy

The power and promise of breast tomosynthesis is here. Selenia Dimensions system with Acquisition Workstation 5000

The Radiology Aspects

Update on MQSA and Mammography Accreditation

MQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR

Vascular & Interventional Education Days Thomas M Griglock, Ph.D., DABR Chief Diagnostic Imaging Physicist, OHSU

BreastScreen Victoria tomosynthesis screening trial, Maroondah pilot: Preliminary Outcomes

Breast Tomosynthesis

Effects of Long-Term Exposure to Radiation. Tim Marshel R.T. (R)(N)(CT)(MR)(NCT)(PET)(CNMT)

Radiation Safety for New Medical Physics Graduate Students

Contrast-Enhanced Breast Tomosynthesis: Combining the Best of Both Worlds for Better Breast-Cancer Diagnosis

Dosimetric Consideration in Diagnostic Radiology

CT Radiation Risks and Dose Reduction

8/3/2016. DBT Physics Basic to Advanced: Primer On Tomosynthesis. Tomosynthesis Pedigree

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

arxiv: v2 [cs.cv] 8 Mar 2018

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Benign Intraparenchymal Scarring in the DBT Era

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters

the one name in cancer care.

Radiation Doses in Radiology: Influence of Standards and Regulations

Patient Dosimetry in Mammography and Tomosynthesis:

Estimates of Risks LONG-TERM LOW DOSE EFFECTS OF IONIZING RADIATION

Financial Disclosures

Annex X of Technical Volume 4 RADIATION AND HEALTH EFFECTS AND INFERRING RADIATION RISKS FROM THE FUKUSHIMA DAIICHI ACCIDENT

Lifetime risk of radiation-induced cancer from screening mammography

Role and Responsibility of Medical Staff in Nuclear Accident

Superior Performance. Lower Dose.* 1,2. World s first and only. 3D breast biopsy. Breast Biopsy Guidance System. Affirm

Diagnostic Medical Physicist Via Christi Hospitals Wichita, Wichita, KS

PRINCIPLES AND METHODS OF RADIATION PROTECTION

Radiation Physics Consultants, Inc. Medical Physicist. Mammography Qualifications, Continuing Experience and Continuing Education

Radiation Exposure 1980 to 2006

Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

Ionizing Radiation. Alpha Particles CHAPTER 1

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

Core Concepts in Radiation Exposure 4/10/2015. Ionizing Radiation, Cancer, and. James Seward, MD MPP

2015 Reimbursement Information for Mammography, CAD and Digital Breast Tomosynthesis 1

Radiation Safety Guide. Analytical X-Ray Equipment

Understanding Radiation and Its Effects

Article Excerpts: Radiation protection concerns among staff performing Fluoroscopic procedures.

APPENDIX G - Organ/Tissue Weighting Factors and Detriment/Risk Coefficients

1/31/2014. Radiation Biology and Risk to the Public

Radiation in Everyday Life

Fremtidens rolle for tomosyntese

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

ICRP Recommendations Evolution or Revolution? John R Cooper Main Commission

Breast positioning system for full field digital mammography and digital breast tomosynthesis system

Digital Breast Tomosynthesis Ready for Routine Screening?

Transcription:

Oh no, it s not!!! with Breast Tomosynthesis It s not what you may be thinking, so I ll tell you! IT IS A VIETNAMESE PUMPKIN! Oh yes, it is! Objectives Explain radiation dose terminology Recognize 2D and 3D dose values Explain exposure and whole body dose MQSA regulations Radiation safety State the clinical benefits of Combo mode acquisition Wonder what the neighbors will say when you plant some of these along the fence next year? What are these lines? Explanation of Radiation Terminology ACR Phantom Regulatory dose limits are based on phantom dose -Mammography Quality Standards Act (MQSA) Patient Breast calculated for each clinical image Effective Organ dose normalized to whole body exposure Allows one to compare risks due to radiation 1

First dose measurement Skin Erythema is the unit for measuring radiation exposure. 1900-1930 Clarence Dally 1904 1 st radiation fatality asst. To Thomas Edison Radiation (50/50 4.5 cm breast) MQSA = 3 mgy 2D~ 1.2 mgy (Tungsten Tube) 3D~1.45 mgy Combo ~2.65 mgy Selenia FFDM ~1.6 mgy (Molybdenum Tube) Screen/Film (ACRIN ~2.0 mgy average) The Modern Era of Radiation Protection Tolerance dose replaced by maximum permissible dose (MPD) in early 1950s limits were calculated and established in the 1970s to ensure that the risk from radiation exposure acquired on the job did not exceed risks encountered in safe occupations ICRU adopted SI units for use with ionizing radiation in 1980 then NCRP adopted Si units for use 1990 Effective dose equivalent then.. ICRP adopted the term effective dose in 1991 3 2.5 2 Phantom 1.5 (mgy) American College of Radiology Phantom : Single Exposure FDA MQSA Limit Absorbed defined as amount of energy per unit mass ionizing radiation passes through an object, energy of the radiation is transferred to that biologic material and absorbed in the body and stays. 1 0.5 0 2D 2D plus 3D MLO 2D plus 3D 2

Equivalent product of the average absorbed dose in tissue or organ. Remember stochastic effects are non-threshold, randomly occurring biologic effects from low dose radiation that can take a long time before damage can be demonstrated. EqD equivalent dose is used for radiation protection purposes when a person receives exposure from various types of ionizing radiation. Response Curves Threshold is where there is a point at which a response or reaction to an increasing stimulation first occurs in radiation. Biologic effects begin to occur only when the threshold level or dose is reached. This usually has a hypothetical sigmoid S Shape curve and this is used in Radiation therapy for high dose cellular response. Effective dose measure of overall risk of exposure to humans from ionizing radiation. Efdincorporates both the effect of type of radiation and the radio sensitivity of the specific organ or body part. This is the overall harm to those biologic components and risk. Radiation Hormesis What is it? -Response Curves LNT linear non-threshold curve of radiation. Both the response to radiation and biologic effects is directly proportional to the dose of radiation. Remember non-threshold means that any radiation dose has the capability for damage to biologic tissue starting at the cellular molecular component level. Hormesis is where the background radiation levels are 1000 times stronger. Proven in Japanese atomic bomb survivors where they received 1.5 15 years equivalent background radiation and have reduced cancer death rate compared to normally exposed control population. Proven on mice who lived 11 days longer. 3

Radiation : 2D plus 3D Tomosynthesis The additional effective dose of 3D tomosynthesis is equivalent to about 2 months of annual natural background radiation in the United States. This is less than natural variations in background radiation Risk from these levels of radiation is low For example, breast cancer incidence is lower in Colorado versus the average US, even though natural background radiation is higher Summary of Radiation : 2D plus 3D Tomosynthesis Additional effective dose of 3D is equivalent to about 2 months of annual natural background radiation in the United States. ACR Phantom for both 2D and 3D combined is less than the FDA MQSA regulatory limit for a single 2D exposure. BERT Background Radiation Radioactivity is present throughout the whole universe with radiation dose varying depending where you live. In the United states the dose of natural radiation can vary anywhere between 100 mrem to 1000 mrem per year depending on geographical regions. Name some other man-made elements Potassium Smoke detectors Bricks and granite Fossil fuels (Coal, Oil, Natural Gas) Fertilizers Televisions 4

2D + 3D Tomosynthesis (Combo Mode) and putting it in perspective FDA panel of experts voting, unanimously agreed the benefitsof combo mode imaging outweigh the risks. Recent News.. FDA panel gives nod to 2D synthetic mode for Hologic breast tomo By Kate Madden Yee, AuntMinnie.com staff writer October 25, 2012 --A U.S. Food and Drug Administration (FDA) panel voted 9 to 1 on October 24 to recommend approval for a new imaging mode on the Selenia Dimensions 3D digital breast tomosynthesis (DBT) system from Hologicthat creates synthesized 2D images from 3D data. The recommendation specifically addresses the use of synthesized 2D images generated by Hologic's C-View software module in place of traditional 2D images when used in conjunction with 3D mammography, Hologic said. C-View is designed to enable tomosynthesis to produce 2D mammography images without the higher radiation dose typically involved in combined 2D/3D studies. Since winning FDA approval in 2011, tomosynthesis has been promoted as a technology that could improve breast screening by collecting a range of data slices acquired as the mammography system's tube head pans around the breast. These slices are typically reconstructed into dynamic 3D volumes that enable radiologists to see around superimposed tissue in the breast. Thank you! Do you have questions? 5