Risk-based QM for Incorrect Isocenter at Day 1 Setup. TG 100 risk based QM development Process Mapping

Similar documents
Therapy symposium Formal Radiation Therapy Safety Processes

The Smart Way to Check Treatment Plans and Charts. Anne W. Greener, Ph.D., FACR American Association Of Medical Dosimetrists June 15, 2016

Risk analysis to inform physics plan review recommendations

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

TG100 Implementation Guide - FTA

Patient-Specific QA & QA Process. Sasa Mutic, Ph.D. Washington University School of Medicine

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

QUARTERLY REPORT PATIENT SAFETY WORK PRODUCT Q J A N UA RY 1, 2016 MA R C H 31, 2016

The Canadian National System for Incident Reporting in Radiation Treatment (NSIR-RT) Taxonomy March 11, 2015

SRS/SBRT Errors and Causes

Your Colleagues. Ellen Yorke Memorial Sloan-Kettering Cancer Center

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Eric E. Klein, Ph.D. Chair of TG-142

Medical Errors in Radiation Therapy 2014

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Elekta MOSAIQ and Philips Pinnacle

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

EORTC Member Facility Questionnaire

The University of Michigan Radiation Oncology Clinic Analysis of Waste in the Radiation Oncology Clinic Patient Flow Process.

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Quality assurance in external radiotherapy

DEPT OF RADIATION ONCOLOGY DEPT OF RADIATION ONCOLOGY

Work partially supported by VisionRT

SRS Uncertainty: Linac and CyberKnife Uncertainties

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

Overview of TG225 - Medical Physics Practice Guideline #1

PGY-1. Resident Review Session Schedule

Patient Safety in the Treatment Process

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

In-Room Radiographic Imaging for Localization

National System for Incident Reporting in Radiation Therapy (NSIR-RT) Taxonomy

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

7/31/2012. Volumetric modulated arc therapy. UAB Department of Radiation Oncology. Richard Popple, Ph.D.

In-Room Radiographic Imaging for Localization

Quality Assurance in Radiation Therapy

RTOG DOSIMETRY DATA SUBMISSION

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Clinical Quality Assurance for Particle Therapy Plus ça même Plus

Global Radiosurgery 2011 All Rights Reserved 1

Radiation Safety in IGRT Cases, Causes and Culture of Safety

Credentialing for the Use of IGRT in Clinical Trials

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

A new geometric and mechanical verification device for medical LINACs

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Universal Couchtop. for safe, efficient treatment planning + imaging. Long Extension. 1 Piece

DELIVERED PATIENT DOSE

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Integrating the Radixact into a Highly Comprehensive Center

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

Using Event Reporting to Improve Patient Safety SAMs Session

RISK ASSESSMENT IN RADIATION THERAPY OF PATIENTS USING PROBABILISTIC SAFETY ANALYSIS OF RADIOTHERAPY DEVICES

RADIATION ONCOLOGY AT UNIVERSITY OF COLORADO HOSPITAL

Hybrid VMAT/IMRT Approach to Traditional Cranio-Spinal Irradiation (CSI): A Case Study on Planning Techniques and Delivery

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Medical Events. Florida Department of Health Division of Emergency Preparedness and Community Support Bureau of Radiation Control

Who Should Know Radiation Oncology Coding?

Bruce Thomadsen. University of Wisconsin - Madison

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Herlev radiation oncology team explains what MRI can bring

IMRT FOR CRANIOSPINAL IRRADIATION: CHALLENGES AND RESULTS. A. Miller, L. Kasulaitytė Institute of Oncolygy, Vilnius University

SunCHECK Patient Comprehensive Patient QA

Patient and Linac QA - present and the future

Advancing critical clinical decisions

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

MPPG 1 Evaluation and quality assurance of x-ray based image guided radiotherapy systems

8/3/2016. The EPID Strikes Back! - EPID In-Vivo Dosimetry. EPID Research Number of Publications. Why EPID in-vivo? Detectable errors: patient

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

Realtime dose monitoring technologies: Luxury or Necessity

Nuclear Associates

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

Image Guided Stereotactic Radiotherapy of the Lung

IMRT QA: Point Dose Measurements or 2D Array?

Technique For Plan Quality and Efficiency Using VMAT Radiosurgery For Patients with Multiple Brain Metastases

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

IVD TIMING test 1 test at 1 fraction 2 test at 2 fraction 3 test at 3 fraction 4 test during next week 5 test during next week 6 test during next week

Presentation Outline. Patient Setup Imaging in RT: Getting the Most Bang for your Buck. Main Errors in RT. Hypothetical Patient Examples

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

Overview of Advanced Techniques in Radiation Therapy

Systematic Risk Analysis Based Approach to Quality Management Process Failure Mode and Effects Analysis

Inter-fractional Positioning Study for Breast Cancer with Proton Therapy using a 3D Surface Imaging System

Patient Safety in the Age of Big Data

Prevention of Medical Errors: Concepts and Tools. Perry Johnson, PhD April 30, 2016

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

Intensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment

Universal Couchtop. for safe, efficient treatment planning + imaging. 5 Year Warranty. Long Extension. 1 Piece

FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017

Transcription:

Risk-based QM for Incorrect Isocenter at Day 1 Setup Ellen Yorke Memorial Sloan Kettering Cancer Center TG 100 risk based QM development Process Mapping Failure Modes and Effects Detect Fault Tree Analysis Failure Modes Cause Effects Risk-based QA/QM for Incorrect isocenter at Day 1 setup This FM describes the isocenter being positioned in the wrong place, due to a device failure. Other causes of this error include a more subtle error (rank 142, step 182), a human failure (inadequate training or inattention, rank 77, step 183). This FM can be a crucial one, especially if the mispositioning happens for multiple fractions or in hypofractionated treatments. One of the best QC steps available is the daily use of IGRT setup techniques and this is one of the major benefits of the IGRT concept. Careful IGRT is an effective technique but it should be accompanied by a departmental protocol limiting the shifts that can be made without a special investigation e.g., physician inspection and approval. If IGRT is not available, then careful use of the patient setup documentation during the setup procedure is crucial. Imaging to confirm the correct location as often as possible will minimize the opportunity for this error to continue through multiple fractions. Other QC can involve using or carefully understanding differences in table coordinates that demonstrate problems with the patient setup especially if the immobilization device used for the patient can be registered to the table. In such cases, review of table coordinates used for treatment at the weekly physics or therapist chart check can also warn the user of problems to be investigated. 1

Day 1 Treatment: position patient for treatment FTA for Incorrect Treatment Isocenter on Day 1 Hardware failure (device failure) Human failure (Inattention) Human failure (Inadequate training) I would add inadequate or incorrect documentation The TG-100 FMEA was also performed with the assumption that there were no specific QA/QC measures in place. The rationale for this concept may be difficult to grasp at first as there are established QM measures associated with most of the analyzed steps and it is tempting to estimate likelihood of failure based on an existing QM program. However, assuming the absence of these QA/QC measures when performing the FMEA allows for a systematic, ground-up redesign of a QM program without possible confusion arising from the presence of existing measures, which may be misplaced or ineffective. Therefore, all risk probability estimates in this report were performed assuming that there were no specific QA/QC measures in place The high risk of the Device Failure shows that sometimes the TG100 approach is in functional agreement with judicious regular physics QA as recommended by several other TGs 2

Device Failure: Lasers Standard Physics QA can reduce O, D to 4 Old-fashioned laser QA Lasers widely used for non-igrt patients and to approximately localize patient for IGRT The TG142 recommendations are in line with the philosophy of tailoring QA to clinical use Daily & Monthly: 2 mm - non IMRT, 1.5 mm - IMRT, 1 mm - SRS/SBRT Beyond lasers TG100: One of the best QC steps available is the daily use of IGRT setup techniques and this is one of the major benefits of the IGRT concept. Careful IGRT is an effective technique but it should be accompanied by a departmental protocol limiting the shifts that can be made without a special investigation e.g., physician inspection and approval. Device Failure: IGRT Linac-based IGRT Requires near-coincidence of 2 or 3 isocenters Treatment beam, MV imaging, kv imaging CBCT also should have good image quality QM for IGRT device failure guided by TG100 methods is in line with recommendations of TG142, 179 TG 142: Monthly QA 2 mm for non srs/sbrt, 1 mm for srs/sbrt) TG 179: Suggests procedures as well as tolerance/frequency Daily for imaging/treatment isocenter coincidence (2 mm) Monthly: geometric calibration, image quality TG179 Where noted, users can modify test frequency and tolerance according to clinical usage and machine capability. Device Failure- Other TG 100 (Appendices A1-3) identified: Incompatibility between treatment machine and R&V system and added Should be found during acceptance testing Risk if the TPS, linac and R&V system use different coordinate systems If Day 1 isocenter is correctly placed, and corresponding couch coordinates are recorded, subsequent errors can be quickly identified by noting large couch couch shifts Software could be designed to flag these Particularly valuable if immobilization locked to couch 3

Hierarchy of Effectiveness * * Safety Is No Accident, ASTRO 2012 Interlocks/ Forcing Functions Automation Simplify/Standardize Checklists, reminders, double checks Policies and Procedures Training and Education Tech Focus Most Useful People Focus Least Useful AAPM 2013, B. Miller, et al Some policies and procedures, though low on the pyramid, can keep D low regardless of cause Policy and procedures Imaging prior to 1 st treatment port films, orthogonal images, cbct Films reviewed and approved by an attending physician ASAP Preferably prior to actual treatment Chart Rounds reviews 1 st day images within a week New eyes, usually during first week of treatment May prevent wrong isocenter from propagating through treatment Each patient should get a review BUT How much time/patient? What about extreme hypofractionation? Encourage a Safety Culture All personnel: question unclear instructions All personnel: ask about what you don t know or understand All personnel: question odd occurrences All personnel: respond in a timely and collegial fashion Provide contact information for all procedures 4

Mitigating Inadequate Training Clear, standardized presentation of setup information from simulation immobilization directions, tattoo locations, shifts Competency exams for new simulator and treatment machine therapists How to preparing and interpret setup instructions Physicist plan checker performs virtual check of setup instructions Do they make sense with respect to the plan? Clearly Document Tattoos from previous treatment Anatomical reference points (e.g. tragi) Planners shifts from simulation tattoos Anatomical structures to register on-treatment imaging with DRRs or planning CT Setup photos Inattention- Anyone can do it! Incomplete or incorrect simulator instructions Planner implements shifts but does not mention them in instructions Physics checker does not notice inconsistencies Treatment therapists do not follow instructions or Treatment therapists do not notice inconsistent instructions MD incorrectly reviews films The T-spine is pretty featureless territory We add a carina outline to help Chart rounds flies by too quickly to notice 5

Sim Planning Checking Setup Review Following 3 slides are from Eric Ford Wrong Isocenter Patient presents for R neck Tx. Previous RT. CT sim, isocenter marked. Dosimetrist picks prior CT instead of current CT. On first Tx: IGRT indicates 2 cm shift. RTT discusses with dosimetrist. Standard fractionation. MD not present. Elect to treat. Dosimetrist discusses with colleague and finds the error. Correction made for next treatment. 6

Select Correct CT Scan Multiple CT scans Check for Correct CT Scan PT firstname, lastname Wrong Isocenter Possible Solutions Include date in the name of the scan Greater awareness during physics checks Introduce error checks into software Vendors: please help! 7

Chart Rounds May catch setup error missed earlier Policy and Procedures Plan-checker or Planner review of setup instructions Timely expert review of Day 1 images; several layers of review Physics QA of localization systems: tolerance, frequency appropriate to use Policy and Procedures Competency exams for simulator and treatment therapists Standardized, almost self-guiding setup documentation forms 8