Noncontact mapping to idiopathic VT from LCC

Similar documents
Case Report. Sumito Narita MD 1;3, Takeshi Tsuchiya MD, PhD 1, Hiroya Ushinohama MD, PhD 2, Shin-ichi Ando MD, PhD 3

Medicine. Dynamic Changes of QRS Morphology of Premature Ventricular Contractions During Ablation in the Right Ventricular Outflow Tract

Radiofrequency Catheter Ablation of Ventricular Tachyarrhythmia Under Navigation Using EnSite Array

Title. CitationJournal of Electrocardiology, 43(5): Issue Date Doc URL. Type. File Information.

Catheter Ablation of VT Without Structural Heart Disease 성균관의대 온영근

Reentrant Ventricular Tachycardia Originating in the Right Ventricular Outflow Tract

Characteristics of systolic and diastolic potentials recorded in the left interventricular septum in verapamil-sensitive left ventricular tachycardia

Use of Catheter Ablation in the Treatment of Ventricular Tachycardia Triggered by Premature Ventricular Contraction

Catheter Ablation of a Complex Atrial Tachycardia after Surgical Repair of Tetralogy of Fallot Guided by Combined Noncontact and Contact Mapping

Original Article. Introduction. Korean Circulation Journal

Case Report Electroanatomical Mapping and Ablation of Upper Loop Reentry Atrial Flutter

Urgent VT Ablation in a Patient with Presumed ARVC

Case 1 Left Atrial Tachycardia

Analysis During Sinus Rhythm of Critical Sites in Reentry Circuits of Postinfarction Ventricular Tachycardia

Basic Electrophysiology Protocols

Conventional Mapping. Introduction

Since pulmonary veins (PVs) have

Electrophysiologic Properties of Pulmonary Veins Assessed Using a Multielectrode Basket Catheter

Dr Mark Earley MD FRCP Consultant Cardiologist

Mechanism of Ventricular Tachycardia Termination by Pacing at Left Ventricular Sites in Patients with Coronary Artery Disease

Adenosine-Sensitive Focal Reentrant Atrial Tachycardia Originating From the Mitral Annulus Aorta Junction

Catheter Ablation of Atrial Tachycardia Originating from the Tip of Right Atrial Appendage

Circulation: Arrhythmia and Electrophysiology CHALLENGE OF THE WEEK

Case Report Catheter Ablation of Long-Lasting Accelerated Idioventricular Rhythm in a Patient with Mild Left Ventricular Dysfunction

Case Report Coexistence of Atrioventricular Nodal Reentrant Tachycardia and Idiopathic Left Ventricular Outflow-Tract Tachycardia

Ankara, Turkey 2 Department of Cardiology, Division of Arrhythmia and Electrophysiology, Yuksek Ihtisas

Ablative Therapy for Ventricular Tachycardia

Step by step approach to EKG rhythm interpretation:

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Case Report Left Ventricular Dysfunction Caused by Unrecognized Surgical AV block in a Patient with a Manifest Right Free Wall Accessory Pathway

Intraoperative and Postoperative Arrhythmias: Diagnosis and Treatment

Common Codes for ICD-10

CATHETER ABLATION FOR TACHYCARDIAS

Reentry in a Pulmonary Vein as a Possible Mechanism of Focal Atrial Fibrillation

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

WPW syndrome and AVRT

Case Report Substrate Based Ablation of Ventricular Tachycardia Through An Epicardial Approach

How to ablate typical slow/fast AV nodal reentry tachycardia

Advances in Ablation Therapy for Ventricular Tachycardia

Ji-Eun Ban, MD, Sang-Weon Park, MD, Hyun-Soo Lee, MPH, Jong-Il Choi, MD, and Young-Hoon Kim, MD

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

Clinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm

Case Report Catheter ablation of Atrial Incisional Tachycardia mistaken for Atrial flutter

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Figure 2. Normal ECG tracing. Table 1.

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

Atrial Tachycardia Originating from the Aortomitral Junction

Case Report Wide-QRS Tachycardia Inducible by Both Atrial and Ventricular Pacing

Journal of the American College of Cardiology Vol. 50, No. 22, by the American College of Cardiology Foundation ISSN /07/$32.

Unusual Tachycardia Association In A patient Without Structural Heart Disease

NAAMA s 24 th International Medical Convention Medicine in the Next Decade: Challenges and Opportunities Beirut, Lebanon June 26 July 2, 2010

Case Report What Next After Failed Septal Ventricular Tachycardia Ablation?

LONG RP TACHYCARDIA MAPPING AND RF ABLATION

Electrical disconnection of pulmonary vein (PV) myocardium

Pulmonary vein isolation (PVI) is

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

Declaration of conflict of interest NONE

Long-Term Follow -Up After Radiofrequency Catheter Ablation of Fascicular Ventricular Tachycardia at National Institute of Cardiovascular Diseases

Intramural Reentrant Ventricular Tachycardia in a Patient with Severe Hypertensive Left Ventricular Hypertrophy

VENTRICULAR TACHYCARDIA WITH HEMODYNAMIC INSTABILITY REFRACTORY TO CARDIOVERSION: A CASE REPORT

Topographic Distribution of Focal Left Atrial Tachycardias Defined by Electrocardiographic and Electrophysiological Data

EKG Competency for Agency

Case Report Catheter ablation of ventricular tachycardia related to a septo-apical left ventricular aneurysm

From the Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Michigan

Ablation of Post-Infarct VTs Unmasking VT Isthmuses Using Pace-Mapping

Case Report Mahaim Fiber Accelerated Automaticity and Clues to a Mahaim Fiber Being Morphologically an Ectopic or a Split AV Node

Successful Ablation with a Multipolar Mapping Catheter for Swallowing-induced Atrial Tachycardia

Chapter 16: Arrhythmias and Conduction Disturbances

Premature ventricular complexes or contractions

12-Lead ECG Interpretation. Kathy Kuznar, RN, ANP

Looks Like VT But Isn't - Successful Ablation Of A Left Free Wall Accessory Pathway With Mahaim-like Properties

Ventricular Tachycardia in Normal Heart: Approach and Management

Bernard Belhassen, MD; Roman Fish, MD; Sami Viskin, MD; Aharon Glick, MD; Michael Glikson, MD; Michael Eldar, MD

Please check your answers with correct statements in answer pages after the ECG cases.

A request for a log book extension must be put in writing and sent to BHRS, Unit 6B, Essex House, Cromwell Business Park, Chipping Norton,

Evidence for Longitudinal and Transverse Fiber Conduction in Human Pulmonary Veins

How to Approach the Patient with CRT and Recurrent Heart Failure

II V 1 HRA 3 4 HB 5 6 HB 3 4 HB 1 2 CS 7 8 CS 5 6 CS 3 4 CS 1 2 ABL 3 4 ABL 1 2 RVA 3 4. T. Suga et al.

In recent years, much attention has been given to cardiac

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation

Treatment of VT of Purkinje fiber origin: ablation targets and outcome

December 2018 Tracings


EKG. Danil Hammoudi.MD

Catheter Ablation of Idiopathic Premature Ventricular Contractions and Ventricular Tachycardias Originating from Right Ventricular Septum

Prediction of Life-Threatening Arrhythmia in Patients after Myocardial Infarction by Late Potentials, Ejection Fraction and Holter Monitoring

ELECTROCARDIOGRAPHY (III) THE ANALYSIS OF THE ELECTROCARDIOGRAM

Pre-excited tachycardia: Atrial tachycardia with a bystander left lateral accessory pathway

Catheter Ablation of Atrial Fibrillation in Patients with Prosthetic Mitral Valve

Ventricular Arrhythmias

Ventricular Tachycardia Substrate. For the ablationist. Stanley Tung, MD FRCPC Arrhythmia Service/St Paul Hospital University of British Columbia

Post-Infarction Ventricular Arrhythmias Originating in Papillary Muscles

Electrical isolation of the pulmonary veins (PVs) to treat

Atrial Tachycardia During Ongoing Atrial Fibrillation Ablation

480 April 2004 PACE, Vol. 27

1995 Our First AF Ablation. Atrial Tachycardias During and After Atrial Fibrillation Ablation. Left Atrial Flutter. 13 Hours Later 9/25/2009

Novel ECG Predictor of Difficult Cases of Outflow Tract Ventricular Tachycardia:

Positive QRS Complex in Lead I as a Malignant Sign in Right Ventricular Outflow Tract Tachycardia

Cardiac Arrhythmias. Cathy Percival, RN, FALU, FLMI VP, Medical Director AIG Life and Retirement Company

Transcription:

Narita S Noncontact mapping to idiopathic VT from LCC Case Report Radiofrequency Catheter Ablation with the Use of a Noncontact Mapping System for Ventricular Tachycardia Originating from the Aortic Sinus Cusp A Case Report Sumito Narita MD 1, Takeshi Tsuchiya MD 1, Keiichi Ashikaga MD 1, Hiroya Ushinohama MD 2, Yuji Tanaka MD 3, Masao Yoshinaga MD 3, Hideyo Kawana MD 4 1 EP Expert Doctors Team Tsuchiya 2 Division of Pediatric Cardiology, Fukuoka Children s Hospital 3 Division of Pediatrics, National Kagoshima Medical Center 4 Division of Cardiology, Aijinkai Uemura Hospital Here we present a 15-year old female in whom an idiopathic ventricular tachycardia (VT) originating from the left aortic sinus cusp was eliminated by radiofrequency catheter ablation (RFCA) under navigation using a noncontact mapping system (NCM). The dynamic activation map constructed with the NCM clearly identified a VT focus in the left aortic sinus cusp, from which the activation spread out to the entire left ventricle. At that site, the virtual unipolar electrogram recorded with the NCM was the same as the contact unipolar electrogram in terms of morphology and timing, a pre-systolic potential preceding the QRS complex by 40 msec was recorded by contact bipolar electrogram and rapid pacing during sinus rhythm resulted in a perfect pace match. RFCA at that site eliminated the VT and the patient has had no recurrence during 10 months of follow-up. (J Arrhythmia 2008; 24: 45 50) Key words: Aortic sinus cusp, Noncontact mapping, Ventricular tachycardia Introduction The noncontact mapping system (NCM) has provided us with a deep insight into mechanisms of tachycardia irrespective of the focal or reentrant mechanism. 1 8) However, the efficacy of the noncontact mapping system in radiofrequency catheter ablation (RFCA) of idiopathic ventricular tachycardia (VT) is still unclear. Here we describe a case in which an idiopathic VT originating from the left aortic sinus cusp (ASC) was eliminated by RFCA under navigation using the NCM. Received 17, December, 2007: accepted in final form 11, March, 2008. Address for correspondence: Takeshi Tsuchiya MD, EP Expert Doctors Team Tsuchiya, Koto 3-14-28, Kumamoto, Kumamoto 862-0909, Japan. TEL: +81-96-368-0403 FAX: +81-96-368-0414 E-mail: tsuchiya@s1.kcn-tv.ne.jp 45

J Arrhythmia Vol 24 No 1 2008 Case Report A 15-year old female was referred for RFCA of a sustained VT, which was documented at medical check up. The electrocardiogram exhibited a left bundle branch block and inferior axis pattern, suggesting that the VT originated from the left coronary cusp or superior portion of the mitral annulus (Figure 1). The patient complained of slight palpitations, and exercise limitations. No organic heart disease was documented by a 12-lead electrocardiography recorded during sinus rhythm, echocardiography, coronary angiography, or left ventriculography. In the Holter electrocardiographic recordings, repetitive VT with a maximum of 813 successive beats were documented and accounted for >60% of the total heart beats in a single day. In this case, medical treatment could be considered as an alternative, but both the patient and her parents expressed a preference for RFCA. Written informed consent was obtained and the session was performed under conscious sedation with a small amount of fentanyl and midazolam. The basic rhythm was nonsustained VT, the same QRS morphology which was documented during the palpitation attacks. A multielectrode array (MEA) used with the NCM (St. Jude Medical, Minnetonka, MN, USA) was introduced into the left atrium (LA) through a long transseptal sheath which was advanced into the LA by the standard Brockenbrough technique. Then the MEA was slightly advanced into the left ventricle (LV) so as to locate one fourth of the MEA at the junction between the LA and LV. Throughout the study, ACT was monitored every 30 minutes and, if it was below 300 seconds, an adequate amount of heparin was injected to maintain ACT between 300 to 400 seconds. The geometry of the LV and ASC was depicted with the ablation catheter advanced via a trans-aortic approach. The recording and analysis Figure 1 Twelve-lead EKG during sinus rhythm (SR) and the ventricular tachycardia (VT). No significant abnormalities were detected during SR. The VT cycle length was 464 msec. The axis of the VT was inferior and had a rightward deviation. Note that R is >S in lead V1 and that the S wave cannot be seen in leads V5-6. These findings imply that the VT focus was located at the left coronary cusp or superior portion of the mitral annulus. 46

Narita S Noncontact mapping to idiopathic VT from LCC by the NCM was performed according to an established method reported by other researchers; the details of NCM have been described elsewhere. 1 8) During the review of the recorded data, a high-pass filter setting of 8.0 Hz was used for the isopotential map created by the NCM. 8) During the dynamic wavefront map of the LV and ASC, the earliest activation was identified at the left coronary cusp (LCC), from which the activation proceeded slowly toward the LV septum, and then rapidly to the entire LV. The virtual unipolar electrogram (VUE) at the site exhibiting a QS pattern (Figure 2), the onset of which corresponded to that of the pre-systolic potential recorded by a contact bipolar electrogram, preceded the QRS complex of the VT by 40 msec. It was noted that the morphology and timing of the contact unipolar electrogram were the same as the VUE obtained by the NCM, which validated the VUE. Ventricular pacing which was performed at a stimulus strength of twice the diastolic threshold and with a pulse width of 2 msec using a programmable stimulator (SEC-3102, Nihon Kohden, Japan) did not initiate and terminate the VT, and ventricular pacing during VT did not exhibit an entrainment phenomenon. Pacing during sinus rhythm at that site (9.9 V) exhibited a perfect pace match as shown in Figure 3. The time interval from the stimulus artifact to the QRS complex during the pacing was 0 msec. Before the RFCA, left coronary angiography was performed in order to confirm that the site was at least more than 1 cm from the left coronary artery orifice (Figure 4b-1, 2). A radiofrequency energy application with an energy output of 20 W (the upper temperature limit was 50 C) resulted in the immediate termination of the VT, while a non-clinical VT and/or frequent premature ventricular contractions were induced by the accidental stimulation with a guidewire introduced through the MEA into the LV (Figure 4c). After the ablation, the VT could no longer be induced by ventricular pacing and/or an isoproterenol injection. There were no procedural complications such as thromboembolism, or mitral/ aortic insufficiency. During a follow-up period of 10 months, the patient has been free from any VT recurrence. Discussion VT originating from the ASC has been reported to Figure 2 Dynamic wavefront map during the ventricular tachycardia (VT). The VT focus was detected at the left coronary cusp (LCC). The virtual unipolar electrogram corresponding to the LCC exhibited a QS pattern, suggesting that the VT focus was located at the LCC. 47

J Arrhythmia Vol 24 No 1 2008 I II III avr avl avf V1 V2 V3 V4 V5 V6 Pacing S-QRS:0 ms VT Figure 3 Pace mapping from the ablation site. A perfect pace match was obtained at that site and the time from the stimulus to the QRS wave was 0 msec. be due to a focal discharge or reentrant mechanism, depending on the case. 9) The present VT seems to have been due to a focal discharge mechanism rather than reentry because ventricular pacing did not initiate or terminate the VT, and ventricular pacing during the VT did not exhibit any entrainment phenomenon. The dynamic activation map created with the NCM clearly revealed the VT focus and subsequent activation to the entire LV, and the detailed analysis of the VUE enabled us to identify the precise localization of the VT focus. These features of the NCM facilitated a quick identification of the ablation target, leading to the easy elimination of the VT. The validity and efficacy of the NCM has been reported not only for VTs 1 3) but also for atrial tachyarrhythmias. 4 8) In our patient, the timing and morphology of the VUE at the ASC were the same as those of the contact unipolar electrogram, verifying the strong correlation between the virtual and contact unipolar electrograms. The distance of the site from the center of the MEA to the target site has been reported to be a crucial factor for the correct and precise analysis of the NCM recordings, and should be <4:0 cm in order to make a correct analysis. 10,11) In our case, the site of the VT focus was expected to be the ASC or superior mitral annulus based on the QRS morphology analysis. Before the RFCA, we had two options to introduce the MEA into the LV, which were the transaortic and transseptal approaches. If the MEA had been introduced into the LV by the trans-aortic approach, the distance from the center of the MEA to the VT focus would probably have been >4:0 cm. In contrast, if the transseptal approach was chosen, the distance could be <4:0 cm. However, if the MEA was located entirely within the LV, the MEA would be too far away from the VT focus. Therefore, after the introduction of the MEA into the LA via the transseptal approach, the MEA was slightly advanced from the LA to the LV so as to locate one forth of the MEA at the junction between the LA and LV, which allowed us to locate the MEA close to the VT focus. Although safety and efficacy in manipulating MEA in the LV has been reported previously 1 3) 48

Narita S Noncontact mapping to idiopathic VT from LCC a b-1 40ms LCA c b-2 ABL MEA Test Shot Ablation Figure 4 a: Local contact bipolar and unipolar electrograms at the ablation site. In the contact bipolar recording, a pre-potential (arrow) was detected which preceded the surface QRS wave by 40 msec. The contact unipolar recording exhibited a QS pattern, with an initial dull component and secondary sharp component. b: Fluoroscopic view (RAO) of the ablation site. The ablation site was located at the left coronary cusp (LCC), which was distant from the ostium of the left coronary artery. Note that the noncontact catheter was located at the anterosuperior mitral annulus, which was positioned within 4 cm of the LCC. c: The electrogram during the ablation. The clinical ventricular tachycardia (arrows) terminated during the test radiofrequency application and no acute recurrence was documented even under an isoproterenol injection. ABL: Ablation catheter, MEA: Multielectrode Array, LCA: Left Coronary Artery and no procedure-related complications, which include cardiac tamponade, thromboembolism or valve/chordae injuries, have occurred in our 240 consecutive cases in which the MEA was introduced into the cardiac chambers, in order to avoid the procedure-related complications mentioned above, caution should be exercised during introduction and placement of the MEA into the LV, and ACT should be monitored constantly. In this patient we measured NIBP every 5 minutes to monitor hemodynamic status after deployment of the MEA, but in patients with unstable VT, direct arterial blood pressure monitoring would be strongly recommended. In the left ASC, the electrogram-qrs interval was different from the stimulus-qrs interval, which were 40 msec and 0 msec, respectively. If the left ASC was locally captured with a minimal output, both time intervals must be the same. The difference in these intervals might be due to the strength of pacing output of 9.9 V, which might have captured not only the true VT focus but also the endocardial exit of the VT, leading to unexpected shortening of the stimulus-qrs interval. In conclusion, the dynamic activation map and detailed analysis of the VUE using the NCM was useful for identifying the VT focus and for examining the subsequent activation, and for navigating the ablation catheter to the target site. The RFCA of idiopathic VT originating from the ASC under navigation using the NCM was useful and safe in this case. 49

J Arrhythmia Vol 24 No 1 2008 Acknowledgement We acknowledge the technical assistance of Yuuho Iwanaga (Nihon Kohden Co., Ltd.). References 1) Schilling RJ, Peters NS, Davies DW: Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia. Circulation 1999; 99: 2543 2552 2) Klemm HU, Ventura R, Steven D, et al: Catheter ablation of multiple ventricular tachycardias after myocardial infarction guided by combined contact and noncontact mapping. Circulation 2007; 115: 2697 2704 3) Pratola C, Baldo E, Notarstefano P: Feasibility of the transseptal approach for fast and unstable left ventricular tachycardia mapping and ablation with a non-contact mapping system. J Interv Card Electrophysiol 2006; 16: 111 116 4) Lin YJ, Tai CT, Tso HW, et al: Electrophysiological characteristics and catheter ablation in patients with paroxysmal atrial fibrillation. Circulation 2005; 112: 1692 1700 5) Tai CT, Liu TY, Lee PC, et al: Non-contact mapping to guide radiofrequency ablation of atypical right atrial flutter. J Am Coll Cardiol 2004; 44: 1080 1086 6) Lin YJ, Tai CT, Huang JL, et al: Characteristics of virtual unipolar electrograms for detecting isthmus block during radiofrequency catheter ablation of typical atrial flutter. J Am Coll Cardiol 2004; 43: 2300 2304 7) Higa S, Tai CT, Lin YJ, et al: Focal atrial tachycardia. New insight from noncontact mapping and catheter ablation. Circulation 2004; 109: 84 91 8) Schnieder M, Ndrepepa G, Weber S, et al: Influence of high-pass filtering on noncontact mapping and ablation of atrial tachycardias. PACE 204; 27: 38 46 9) Tsuchiya T, Yamamoto K, Tanaka E, et al: Reentrant ventricular tachycardia originating from the aortic sinus cusp: a case report. J Cardiovasc Electrophysiol 2004; 15: 1216 1219 10) Kadish A, Hauck J, Pederson B, et al: Mapping of atrial activation with a noncontact multielectrode catheter in dogs. Circulation 1999; 99: 1906 1913 11) Earley MJ, Abrams DJR, Sporton SC, et al: Validation of the noncontact mapping system in the left atrium during permanent atrial fibrillation and sinus rhythm. J Am Coll Cardiol 2006; 48: 485 491 50