e-brochure 2009 CAPILLARY COLUMNS LABORATORY dex FAST-GC MegaHT High Temperature Columns Standard conventional GC columns

Similar documents
Gas chromatography columns and accessories

dex ~ r~,~ c hiral columns Mega High Temperature columns PRESS-AT connectors since

Colonne Gascromatografiche

columns accessories and solutions improve your GC analysis

CAPILLARY COLUMNS: 007-1

GC Capillary Columns. SGE GC Capillary Column innovation, manufacture and selection % Dimethyl Polysiloxane BP1 83 BP1 PONA 84 BPX1 84

CAPILLARY COLUMNS. Cap. simply Quality

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

Improving the Analysis of 37 Fatty Acid Methyl Esters

Capillary columns for GC

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Investigating GCxGC separations using selective column chemistry and compound derivatization pairings for common metabolomics chemical compounds

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Ultra Columns. also available. ordering note

REPORT of ANALYSIS OF PESTICIDE RESIDUES. in SOFT DRINK SAMPLES sent by DIRECTORATE GENERAL OF HEALTH SERVICES, NEW DELHI to CFL, Mysore

Ultra Columns HPLC COLUMNS

A comparison study of the analysis of volatile organic acids and fatty acids

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Rapid Separation of Fatty Acid Methyl Esters

Gas chromatography. Gas chromatography

An Introduction and Overview on Comprehensive Two-Dimensional Gas Chromatography (GCxGC): New Opportunities for Unresolved Complex Mixtures

Evaluation of a New Ionic Liquid Stationary Phase with PEG Like Selectivity

FATTY ACID PROFILING BY GAS CHROMATOGRAPHY FOR THE SHERLOCK MIS

Determination of Triglycerides and Waxes in Food Products Using Cool On-Column Injection and the MET- Biodiesel Capillary Column

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Gas chromatography. 298

DETERMINATION OF FATTY ACIDS IN EDIBLE OILS BY CAPILARY GC

GREENPEACE RESEARCH LABORATORIES

VOLUNTARY MONOGRAPH. Council for Responsible Nutrition March 2006

Enantioselective separation of chiral PCBs by multidimensional gas chromatography techniques. Application to real samples. M.J.

New GCMS Applications

ANALYSIS OF CARNAUBA WAX ON BPX5

Agilent Technologies Prep LC Columns

Gas chromatography. Gas chromatography. Basic principles of GC. Capillary columns for GC. Derivatisation reagents.

HPLC Columns. HPLC Accessories HPLC Column Test Mixes Reference Books... HPLC Applications...

A Rapid Method for Trans-Fatty Acid Determination Using a Single Capillary GC Seiichi Shirasawa, Akiko Sasaki, Yasue Saida and Chiemi Satoh

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Secrets to Successful GC-MS/MS Pesticide Method Development

HPLC. Varian Dynamax Preparative HPLC Columns

Chromatography Vacuum Ultraviolet Spectroscopy

Rapidly Analyze a Wide Range of Glycol Ethers by GC-MS Using the New Rxi -1301Sil MS Column

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Application Note. Authors. Abstract. Petrochemical

Martin Lommatzsch Gottfried-Hagener-Str. 60 D Köln. Report

HYPHENATED AND COMPREHENSIVE CHROMATOGRAPHIC TECHNIQUES FOR TRACE ANALYSIS IN EDIBLE OILS AND FATS

Restek Ultra II HPLC Columns

Simply GCxGC GC GC Made Simple and Easy to Use

HPLC Products. New 1.9μm Pinnacle DB Small Particle HPLC Columns. 2007/08 Edition. Chromatography Products. hplc columns.

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

Improved Analysis of Fatty Acids by Capillary GC columns based on Ionic Liquids F. Michel, L.M. Sidisky, M.D. Buchanan, G.A. Baney, Y. Ni,J.L.

NEW! 200 m GC Columns for Detailed Analysis of cis/trans FAME Isomers

Thermal induction of 9t12t linoleic acid: A new pathway for the formation of Conjugated Linoleic Acids

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

DET REPORT NO. 69 JUNE 2015

Comprehensive analysis of FAMEs, fatty acids, and triglycerides. Agilent J&W GC columns for food nutrition testing

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package

Choosing Preparative Columns

Analyze Dietary Fatty Acids, Sterols, and Lignans with an Agilent J&W DB-5ms UI Column

MULTIDIMENSIONALE SCHEIDINGEN IN DE GAS- EN VLOEISTOF CHROMATOGRAFIE

using the Agilent 7696A Sample Prep

Highly Reproducible Detailed cis/trans FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test

Qualitative analysis of a commercial naphthenic acids mixture using comprehensive multidimensional gas chromatography-mass spectrometry ( 2D-GCMS )

GC/MS BATCH NUMBER: C50101

Environmental Contaminant Standards

Determination of Adulterants in Olive Oil Analysis of Waxes and Fatty Acid Methyl and Ethyl Esters with Capillary GC and Agilent OpenLAB Software

SELECTIVE ACCELERATED SOLVENT EXTRACTION FOR THE ANALYSIS OF SOIL POLYCYCLIC AROMATIC HYDROCARBONS AND STEROLS

CE Columns and Accessories

Comprehensive two-dimensional gas chromatography for the separation of fatty acids in milk

Lutein Esters from Tagetes Erecta

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases

ACE C18-AR Use the Power!

Zillillah, a Guowei Tan, a,b and Zhi Li* a,b. 4 Engineering Drive 4, Singapore Fax: ; Tel:

Dikma Technologies Inc.

ZB-FAME The Fast FAME GC Column

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

GC/MS BATCH NUMBER: F50101

Supporting Information

Organic Chemistry Diversity of Carbon Compounds

Am I getting the very best value from my UHPLC analyses?

A carboxylic acid is an organic compound that contains a carboxyl group, COOH

Ultimate Core Performance to Maximize Your Investment

Chiral Gas Chromatography

Organophosphorus Pesticides Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column. Application Note. Environmental. Abstract.

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction

MOSH/MOAH Analysis Online LC/GC System with Chronect -LC/GC

An Untargeted Exposure Study of Small Isolated Populations Using Atmospheric Gas Chromatography Coupled with High Resolution Mass Spectrometry

Gas chromatographic analysis of conjugated linoleic acids

Restek PAL SPME Fibers cat.#

176 YMC Chiral Columns

Determination of toxaphene in fish samples - a congener specific approach using high resolution mass spectrometry

FAMEs Analyses High-Resolution GC Analyses of Fatty Acid Methyl Esters

Environmental Contaminant Product Standards

NUTRITIONAL COMPONENTS OF SUPERCRITICAL CARBON DIOXIDE EXTRACTED WHEAT GERM OIL

ISO INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of individual and total sterols contents Gas chromatographic method

Transcription:

CAPILLAY COLUMNS Our Experience in Gas Chromatography at Your Service -1-5 -WAX -1701-17 -SE54 Staard conventional GC columns CUSTOM DEDICATED COLUMNS dex chiral columns FAST-GC MegaHT High Temperature Columns m /z GC MS ETENTION GAP PESS-FIT Union PESS-FIT Y - 3 ways PESS-FIT Multiways e-brochure 2009 s.n.c. - Capillary Columns Laboratory - Via Plinio, 29-20025 Legnano (MI) - Italy

-1-5 -WAX -1701-17 -SE54 CAPILLAY COLUMNS - 30 years of experience in GC - The most complete range of Stationary Phases for: Conventional-GC FAST-GC Wide Bore GC Chiral-GC GC-MS - Special a Innovative Products for: GCxGC (2DGC) High Temperature GC - Custom Products by request with no additional costs - PESS-FIT Connectors (2-ways, 3-ways Y, Multiways) - etention Gaps Deactivated for any purpose Staard conventional GC columns CUSTOM DEDICATED COLUMNS FAST-GC dex chiral columns m /z GC MS MegaHT High Temperature Columns PESS-FIT Union PESS-FIT Y - 3 ways PESS-FIT Multiways ETENTION GAP e-brochure 2009 Columns Catalog Column Cross - eference (by phase)... Phase Polarity Quick View... Column Cross - eference (by application)... Column Dimensions available... pag. 1 pag. 2 pag. 3 pag. 5

Column Cross - eference (by phase) CAPILLAY COLUMNS 1 Agilent Phase Composition (J&W) Alltech Phenomenex Quadrex estek SGE Supelco Varian - 1 DB-1 / HP-1 AT-1 ZB-1 007-1 tx-1 BP-1 SPB-1 CP Sil 5 CB - 1 MS DB-1 ms, HP-1 ms AT-1 ZB-1 ms 007-1 tx-1 ms SPB-1, Equity-1 CP Sil 5 CB Low Bleed / ms - 5 5% Phenyl - 95% Methyl Polysiloxane DB-5 / HP-5 AT-5 ZB-5 007-5 tx-5 BP-5 SPB-5 CP Sil 8 CB - 5 MS - Wax - Wax MS - 1701-35 5% Phenyl - 95% Methyl Polysiloxane 7% Cyanopropyl, 7% Phenyl, 86% Methyl Polysiloxane 65% Methyl Polysiloxane DB-5 ms, Ultra-2 HP-5 ms DB-Wax, HP-Wax DB-Wax, HP-Wax DB-1701, HP-1701 DB-35, HP-35 AT-5 ms AT-Wax AT-Wax ms 007-5 ms tx-5 ms SPB-5, Equity-5 ZB-Wax 007-CW tx-wax BP-20 OmegaWax CP Wax 52 CB ZB-Wax 007-CW Stabilwax BP-20 OmegaWax CP Wax 52 CB AT-1701 ZB-1701 007-1701 tx-1701 BP-10 SPB-1701 AT-35 ZB-35 007-11 tx-35 BPX-35, BPX-608 SPB-35, SPB-608 CP Sil 19 CB, VF-1701 ms - 35 MS 65% Methyl Polysiloxane DB-35 ms tx-35 Sil ms - 17 DB-17, HP-17 AT-50 ZB-50 007-17 tx-17 BPX-50 SPB-50 CP Sil 24 CB, VF-17 ms - 17 MS new column, no equivalent - ACID (FFAP) Acid Modified DB-FFAP AT-1000 007-FFAP Stabilwax-DA BP-21 SPB-1000 CP Wax 58 CB - 10 FAMEs 100% Cyanopropyl Polysiloxane HP-88 SP-2330, AT-Silar tx-2330 BPX-70 CP Sil 88 SP-2331,SP-2380-225 25% Cyanopropyl, 25% Phenyl, DB-225, HP-225 AT-225 007-225 tx-225 BP-225 CP Sil 43 CB - 225 MS 25% Cyanopropyl, 25% Phenyl, new column, no equivalent - 624 3.5% Cyanopropyl, 3.5% Phenyl, 93% Methyl Polysiloxane DB-624,DB-1301 HP-624,HP-1301 AT-624 ZB-624 007-624, 007-1301 tx-624, Vocol, tx-1301 BP-624 SPB-1301, Vocol, SPB-624 CP 1301, VF-624 ms - 13 13% Phenyl, 87% Methyl Polysiloxane CP Sil 13 CB - BASIC Proprietary Phase, for Basic Compous separation (Amines) - SOLVE Proprietary Phases, for complex Solvent mixtures separation

Column Cross - eference (by phase) CAPILLAY COLUMNS 2 Agilent Phase Composition (J&W) Alltech Phenomenex Quadrex estek SGE Supelco Varian - 50 50% Cyanopropyl, - 20 20% Phenyl - 80% Methyl Polysiloxane AT-20 007-7 tx-20 SPB-20-200 Trifluoropropyl Methyl Polysiloxane DB-200, DB-210 AT-210 007-210 tx-200 SP-2401 VF-200 ms - DAI Direct Acqueosus Injection - LAP Lipid Analysis - PLUS Copolymer + Methyl Polysiloxane Phase Polarity Quick View Apolar - 1-13 - 20-35 - 17-200 - Wax -ACID (FFAP) - 5-624 - 225-1701 - 50-10 Polar

Column Cross - eference (by application) CAPILLAY COLUMNS 3 Phase Composition Temperature Max * USP Nomenclature EPA Methods, Normatives Applications - 1 G1, G2, G38 EPA 606 General Purpose column for solvent impurities, PCB congeners, Aroclor mixes, simulated distillation, drugs of abuse, gases, natural gases, essential oils, semivolatiles, pesticides - 1 MS G1, G2, G38 EPA 606 General Purpose column (see -1) for GC-Ms use - 5 5% Pehnyl - 95% Methyl Polysiloxane G27, G36 EPA 611/8110, 604, 612, 607, 608/8081 General Purpose column for solvent impurities, PCB congeners, Aroclor mixes, hydocarbons, essential oils, semivolatiles, pesticides etc. - 5 MS - Wax 5% Pehnyl - 95% Methyl Polysiloxane G27, G36 G14, G15, G16, G20, G39 EPA 8270, 625 525 EPA 602, 603, 619 General Purpose column (see -5) for GC-Ms use General Purpose column for FAMEs, solvents, BTEX aromatics, flavour compous, alcohols - Wax MS G14, G15, G16, G20, G39 EPA 602, 603, 619 General Purpose column (see -Wax) for GC-Ms use - 1701 7% Cyanopropyl, 7% Phenyl, 86% Methyl Polysiloxane 280 C G46 General Purpose column for alcohols, oxygenates, PCB congeners, Aroclor mixes, ideal as confirmation column - 35 65% Methyl Polysiloxane G42 General Purpose column for volatile compous, flavor compous, alcoholic - 35 MS 65% Methyl Polysiloxane G42 General Purpose column (see -35) for GC-Ms use - 17 General Purpose column for volatile compous, flavor compous, alcoholic - 17 MS General Purpose column (see -17) for GC-Ms use - ACID (FFAP) Acid Modified G14, G15, G16, G20, G39 General Purpose column for Free Acids, FAMEs, solvents, BTEX aromatics, flavour compous, alcohols, polar compous - 10 FAMEs 100% Cyanopropyl Polysiloxane G48 General purpose column ideal for cis/trans FAMEs a dioxin isomers - 225 25% Cyano Propyl, 25% Phenyl, 280 C G7, G19 General Purpose column for carbohydrate, sterols, flavors compous - 225 MS 25% Cyano Propyl, 25% Phenyl, 280 C G7, G19 General Purpose column (see -225) for GC-Ms use - 624 3.5% Cyanopropyl, 3.5% Phenyl, 93% Methyl Polysiloxane 300 C G43 EPA 624, General purpose column ideal for Volatile Organic Compous - 13 13% Phenyl, 87% Methyl Polysiloxane General Purpose column for volatile compous, flavor compous, alcoholic - BASIC Proprietary Phase, for Basic Compous separation (Amines) Application-specific column for basic compous analysis, amines - SOLVE Proprietary Phases, for complex Solvent mixtures separation Application-specific columns for complex mixtures of solvents *: the maximun temperature may change depeing on the film thickness

Column Cross - eference (by application) CAPILLAY COLUMNS 4 Phase Composition Temperature Max * USP Nomenclature EPA Methods, Normatives Applications - 50 50% Cyanopropyl, General Purpose column for carbohydrate, sterols, flavors compous, confirmation column - 20 20% Phenyl - 80% Methyl Polysiloxane G28, G32 General Purpose column for volatile compous, flavor compous, alcoholic - 200 Trifluoropropyl Methyl Polysiloxane 300 C G6 General Purpose column Freon Fluorocarbons, alcohols, ketones, confirmation column - DAI Direct Acqueosus Injection Application-specific column for Direct Acqueosus Injections without sample preparation - LAP Lipid Analysi 370 C Application-specific column for Lipids, Sterols, Triglycerides analysis - PLUS Copolymer + Methyl Polysiloxane General Purpose column - Biodiesel Phases for Biodiesel Analysis 370 C for UNI EN ISO 14105 UNI EN ISO 14105 (ASTM 6584), UNI EN ISO 14103 (2003) Application-specific columns. The 2 -Biodiesel columns are one for triglycerides analysis (T max 370 C for UNI EN ISO 14105 (ASTM 6584) a one for UNI EN ISO 14103 - TNT 8095 Unique phase EPA 8095 Application-specific column for Explosives Mixtures according to EPA Method 8095 - Alc 1 & 2 Unique phases Application-specific columns for Blood Alcohols testing; equivalents to DB-ALC 1 & 2, tx-bac 1& 2 - PAH Unique phase Application-specific column for Polycyclic Aromatics Hydrocarbons - 1 PONA Application-specific column for Detailed hydrocarbon analysis, equivalent to DB-Petro, HP-PONA, tx-1 PONA DET Beta DAC Beta DAC Gamma DET Gamma DMP Beta DMT Beta *: the maximum temperature may change depeing on the film thickness

Column dimensions available CAPILLAY COLUMNS 5 snc offers a wide range of column dimensions; we can supply internal diameters from 0.05mm 0.53mm, from 2m 105m a film thickness until 5.00 micron. Fast - GC Conventional - GC Wide Bore - GC ID Length Film Thickness* ID Length Film Thickness* ID Length Film Thickness* 0.05 mm 2 m 2.5 m 5 m 0.10 micron 0.18 mm 0.20 mm from 10 m 60 m from 1.2 micron 0.53 mm from 10 m 105 m 5 micron 0.10 mm 2.5 m 5 m 10 m 0.15 mm 2.5 m 5 m 10 m 15 m 20 m 25 m 0.10 micron 0.20 micron 0.10 micron 0.20 micron 0.25 micron 0.50 micron 0.25 mm from 10 m 105 m 0.32 mm from 10 m 105 m from 1.5 micron from 5 micron You can completely customize your product selecting all combination of sizes but also ask for out of catalog products. We can develop a custom solution especially for your analytical problem without any additional costs. All our stationary phases are available for FAST-GC, Conventional-GC a Wide Bore GC. *: the maximum film thickness depe on the stationary phase type