Determination of Venlafaxine and Modafinil in Individual Tablet Dosage Forms using Single RP-HPLC Method

Similar documents
METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

RP-HPLC Method Development and Validation of Abacavir Sulphate in Bulk and Tablet Dosage Form

DEVELOPMENT AND VALIDATION OF NEW HPLC METHOD FOR THE ESTIMATION OF PALIPERIDONE IN PHARMACEUTICAL DOSAGE FORMS

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

International Journal of Pharma and Bio Sciences DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF STRONTIUM RANELATE IN SACHET

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF BACLOFEN IN BULK AND PHARMACEUTICAL DOSAGE FORMS

Pelagia Research Library

Journal of Chemical and Pharmaceutical Research, 2018, 10(3): Research Article

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Method Development and Validation for the Estimation of Saroglitazar in Bulk and Pharmaceutical Dosage Form by RP-HPLC

Available online at Scholars Research Library

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Stability indicating RP-HPLC method development and validation of Etizolam and Propranolol hydrochloride in pharmaceutical dosage form

Pelagia Research Library

Method Development and Validation for Simultaneous Estimation of Atorvastatin and Ezetimibe in Pharmaceutical Dosage Form by HPLC

Development and Validation for Simultaneous Estimation of Sitagliptin and Metformin in Pharmaceutical Dosage Form using RP-HPLC Method

Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD ESTIMATION OF TOLVAPTAN IN BULK PHARMACEUTICAL FORMULATION

RP-HPLC Method for the Simultaneous Estimation of Sitagliptin Phosphate and Metformin Hydrochloride in Combined Tablet Dosage Forms

Isocratic Reversed Phase Liquid Chromatographic Method Validation for the Determination of Cilostazol in Pure and Formulations

Simultaneous estimation of Metformin HCl and Sitagliptin in drug substance and drug products by RP-HPLC method

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF LACOSAMIDE IN BULK AND ITS PHARMACEUTICAL FORMULATION

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS TOLBUTAMIDE IN PURE AND PHARMACEUTICAL FORMULATIONS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

SIMULTANEOUS QUANTIFICATION OF TELMISARTAN AND METOPROLOL SUCCINATE IN TABLETS BY LIQUID CHROMATOGRAPHY

Journal of Chemical and Pharmaceutical Research

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

ANALYTICAL TECHNIQUES FOR THE QUALITY OF ANTI- AIDS DRUGS

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Journal of Chemical and Pharmaceutical Research, 2017, 9(9): Research Article

Development and validation of RP-HPLC method for simultaneous estimation of gliclazide and metformin in pure and tablet dosage form

International Journal of Pharma and Bio Sciences

A simple validated RP-HPLC method for quantification of sumatriptan succinate in bulk and pharmaceutical dosage form

Scholars Research Library. Der Pharmacia Lettre, 2015, 7 (5):44-49 (

Scholars Research Library

J Pharm Sci Bioscientific Res (4): ISSN NO

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC

ISSN (Print)

VALIDATED RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF DEXAMETHASONE AND GRANISETRON IN COMBINED DOSAGE FORMS

A stability indicating RP-HPLC method for simultaneous estimation of darunavir and cobicistat in bulk and tablet dosage form

Available online Research Article

New RP-HPLC Method for the Determination of Fludarabine in Pharmaceutical Dosage Forms

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Research Article Simultaneous Estimation of DL-Methionine and Pyridoxine Hydrochloride in Tablet Dosage Form by RP-HPLC

Journal of Chemical and Pharmaceutical Research

A Reverse Phase HPLC Method Development and Validation for the Determination of Paliperidone in Pure and Dosage Forms

NOVEL RP-HPLC METHOD. B.Lakshmi et a. concentration range KEY INTRODUCTION. Diltiazem is used to. . It works by of contractionn of the. (dilate).

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

Scholars Research Library

36 J App Pharm Vol. 6; Issue 1: 36-42; January, 2014 Rao et al., 2014

Rao and Gowrisankar: Stability-indicating RP-HPLC Method for Pseudoephedrine, Ambroxol and Desloratadine

MEDAK DIST. ANDHRA PRADESH STATE, INDIA. Research Article RECEIVED ON ACCEPTED ON

Journal of Pharmacreations

Journal of Chemical and Pharmaceutical Research, 2014, 6(7): Research Article

A Validated Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Clinidipine Combined Tablet dosage forms

Volume 2 (6), 2014, Page CODEN (USA)-IJPRUR, e-issn: International Journal of Pharma Research and Health Sciences

Estimation of Etoricoxib in Tablet Dosage form by RP- HPLC using Internal Standard with Emphasize on Specificity Parameter Method

Int. J. Pharm. Sci. Rev. Res., 24(2), Jan Feb 2014; nᵒ 18,

World Journal of Pharmaceutical Research

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Airo International Research Journal ISSN : Volume : 7 October 2015


Journal of Chemical and Pharmaceutical Research, 2013, 5(1): Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR ESTIMATION OF FEBUXOSTAT IN BULK AND TABLET DOSAGE FORM

Development and validation of related substances method for Varenicline and its impurities

A New RP-HPLC Method Development and Validation for Simultaneous estimation of Telmisartan and Pioglitazone in Pharmaceutical Dosage Form

International Journal of Farmacia

Available online Research Article

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Journal of Chemical and Pharmaceutical Research

AMERICAN JOURNAL OF BIOLOGICAL AND PHARMACEUTICAL RESEARCH

IJPAR Vol.3 Issue 4 Oct-Dec-2014 Journal Home page:

Stress Degradation Studies And Validation Method For Quantification Of Aprepitent In Formulations By Using RP-HPLC

Research and Reviews: Journal of Pharmaceutical Analysis

Available online Research Article

CHAPTER 2 SIMULTANEOUS DETRMINATION OF ANASTROZOLE AND TEMOZOLOMIDE TEMOZOLOMIDE CAPSULES 20 MG AND ANASTROZOLE TABLETS 1 MG

METHOD DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF NEW ANTIDIABETIC AGENT LINAGLIPTIN IN BULK AND IN PHARMACEUTICAL FORMULATION

Comparison of conventional HPLC with UPLC method for determination of albuterol sulfate and it s impurities in pharmaceutical formulation

Int. J. Pharm. Sci. Rev. Res., 30(1), January February 2015; Article No. 32, Pages:

Journal of Global Trends in Pharmaceutical Sciences

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF ETORICOXIB AND THIOCOLCHICOSIDE IN PHARMACEUTICAL DOSAGE FORMS

International Journal of Medicine and Pharmaceutical Research. International Journal of Medicine and Pharmaceutical Research

Available online at Scholars Research Library

Available online at Scholars Research Library

Asian Journal of Research in Chemistry and Pharmaceutical Sciences

IAJPS 2018, 05 (01), J. Amutha Iswarya Devi et al ISSN Available online at:

Estimation of Zanamivir Drug present in Tablets using RP-HPLC Method

Research Article. A novel validated RP-HPLC-DAD method for the estimation of Lenvatinib Mesylate in bulk and pharmaceutical dosage form

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (6): (

Sujatha and Pavani et.al. Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

REVERSE PHASE HPLC METHOD FOR THE ANALYSIS OF ALFUZOSIN HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS

Analytical method validation for tablet of phenoxymethyl penicillin potassium by RP-HPLC method

A Validated Rp-Hplc Method for the estimation of Milnacipran in Tablet dosage forms

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Transcription:

Tropical Journal of Pharmaceutical Research April 2013; 12 (2): 239-245 ISSN: 1596-5996 (print); 1596-9827 (electronic) Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City, 300001 Nigeria. All rights reserved. Original Research Article Available online at http://www.tjpr.org http://dx.doi.org/10.4314/tjpr.v12i2.17 Determination of Venlafaxine and Modafinil in Individual Tablet Dosage Forms using Single RP-HPLC Method Mohammad Younus 1 *, Md Fasiuddin Arif 2, M Paul Richards 3 and D Bharat Kumar 4 1 Chandra Labs, 2 Dr. Reddy s Laboratories Ltd, 3 Malla Reddy College of Pharmacy, Hyderabad Andhra Pradesh India, 4 Vignan Institute of Pharmaceutical Sciences, Nalgonda Dist, Andhra Pradesh, India *For correspondence: E-mail: mdyounus1127@gmail.com; Tel: +91-8686062421 Received: 19 June 2012 Revised accepted: 30 January 2013 Abstract Purpose: To develop a simple and selective isocratic method for the determination of venlafaxine and modafinil in tablet dosage forms. Methods: The compounds were analyzed on Waters symmetry C18 column (4.6 mm x 250 mm i.d, 5µm) using a mobile phase consisting of a mixture of ammonium acetate buffer (ph was adjusted to 4.0 with glacial acetic acid):10 % methanol in acetonitrile, in the ratio of 60:40. The flow rate was 1.0 ml/min and column effluents were monitored at 225 nm. The method was validated according to ICH guidelines. Results: Venlafaxine and modafinil were eluted with retention times of 4.416 min and 6.443 min, respectively. The method was linear in the range of 1.0-50 µg/ml for both venlafaxine and modafinil. The relative standard deviation (%RSD) was < 1 for both drugs while mean recovery values at different concentration levels were within limits. The performance of the method was not changed when small variations in the method were made. Conclusion: The proposed method is accurate, reproducible and low-cost, and can be used for the routine analysis of the individual drugs in formulations. Keywords: Venlafaxine, Modafinil, Isocratic method, Validation Tropical Journal of Pharmaceutical Research is indexed by Science Citation Index (SciSearch), Scopus, International Pharmaceutical Abstract, Chemical Abstracts, Embase, Index Copernicus, EBSCO, African Index Medicus, JournalSeek, Journal Citation Reports/Science Edition, Directory of Open Access Journals (DOAJ), African Journal Online, Bioline International, Open-J-Gate and Pharmacy Abstracts INTRODUCTION Venlafaxine is a third-generation, structurally novel phenethyl bicyclic antidepressant [1]. Venlafaxine inhibits synaptosomal re-uptake of both serotonin and noradrenalin, and it is also a relatively weak inhibitor of dopamine re-uptake [2]. Modafinil, prescribed principally to treat narcolepsy, is undergoing assessment for other neuropsychiatric disorders and medical conditions. The neurochemical substrates of modafinil are unresolved. It has been postulated that modafinil enhances wakefulness by modulating dopamine, norepinephrine, or serotonin transporter activities [3]. There are several methods reported for the determination of venlafaxine in biological fluids [4-7] However, for its determination in drug formulations only two methods have been reported [8-9]. For determination of modafinil in biological fluids [10-14] and formulations [15-16], some methods have been reported. The aim of this present study is to develop a single method for the Trop J Pharm Res, April 2013;12 (2): 239

determination of venlafaxine and modafinil in their respective dosage forms. EXPERIMENTAL Materials and equipment Waters High Performance Liquid Chromatographic HPLC system equipped with a diode array detector and auto-sampler was used. Waters symmetry C18 column (4.6 mm x 250 mm i.d) was used for separation. Chromatographic and integrated data were recorded using Empower 2 software. All the reagents were of analytical grade unless stated otherwise. Milli Q water, HPLC-grade acetonitrile (Rankem, Mumbai, India), methanol (Rankem, Mumbai, India) and ammonium acetate (AR grade, S.D. Fine Chem, Mumbai, India) were used. All solutions were filtered through 0.45 µm membrane filters procured from Pall Pharma Lab Filtration Pvt Ltd (Mumbai, India). Preparation of standard solutions Twenty tablets of venlafaxine were accurately weighed, ground to powder and powder equivalent of 25 mg (1 tablet) of active ingredient was taken into a 50 ml volumetric flask, dissolved in 35 ml of 50% methanol in water (diluent), ultra sonicated for about 10 min, filtered and volume made up to the mark with the diluent. From this solution, 0.5 ml of solution was transferred to 10 ml volumetric flask, 5 ml of diluent was added, sonicated to mix and volume was made up to mark with diluent. Ten milligrams of modafinil working standard was taken into a 10 ml volumetric flask, dissolved in 4-5 ml of diluent, ultra-sonicated for about 10 min, filtered and the volume made up to the mark with the diluent (Standard Stock). From this solution, 0.2 ml of solution was transferred to 10 ml volumetric flask, 5 ml of diluent was added, sonicated to mix and the volume was made up to mark with diluent. Preparation of sample solutions A working standard of venlafaxine (12.5 mg) was taken into a 25 ml volumetric flask, dissolved in 15 ml of diluent, ultra-sonicated for about 10 min, filtered and the volume made up to the mark with the diluent (Standard Stock). From this solution, 0.5 ml of solution was transferred to 10 ml volumetric flask, 5 ml of diluent was added, sonicated to mix and the volume made up to mark with diluent. Twenty tablets of modafinil were accurately weighed, grounded to powder and powder equivalent of 200 mg (1 tablet) of active ingredient was taken into a 100 ml volumetric flask, dissolved in 70 ml of diluent, ultrasonicated for about 10 min, filtered and the volume made up to the mark with the diluent. From this solution, 0.1 ml of solution was transferred to a 10 ml volumetric flask, 5 ml of diluent was added, sonicated to mix and the volume made up to mark with diluent. Preparation of 0.02 M ammonium acetate buffer (ph 4.0) Ammonium acetate (1.07972 g) was transferred to a 1 L volumetric flask. water (700 ml) was added and sonicated to dissolve and degas, filtered through 0.45µm filter paper and volume was made up to the mark with water. The ph of the resultant solution was adjusted to 4.0 with glacial acetic acid and sonicated for 2 min for proper mixing. Preparation of 10 % methanol in acetonitrile Methanol (45 ml) was taken in a 500 ml measuring cylinder, made up to volume with acetonitrile and sonicated for 2 min for proper mixing. System suitability Standard solutions of venlafaxine and modafinil were injected six times and chromatograms were recorded. Relative standard deviation (% RSD) of retention times (Rt) and peak areas were calculated. The mean of tailing factor (T. Factor) and theoretical plates (T. Plates) were also calculated. Specificity Blank solution (mobile phase), standard solutions, sample solutions and placebo solution (sample solution but excluding active ingredients) were injected separately into the system and chromatograms were recorded. Precision Six different samples of both drugs were analyzed and % RSD of assay values was calculated. Ruggedness (Intermediate precision) The analysis was performed by a second analyst on Schimadzu HPLC system. The assay of six Trop J Pharm Res, April 2013;12 (2): 240

different samples was performed and % RSD of assay values was calculated. Linearity Solutions in the concentration range of 1-50 µg/ml were injected and chromatograms were recorded. Accuracy Accuracy of method was measured in terms of % recovery. Sample solutions were prepared at three different concentration levels, i.e., 80, 100 and 120 %. A predetermined amount of standard was added to these solutions and % recovery was determined by assaying the solutions. Robustness Slight variations in buffer ph, mobile phase composition, column temperature and flow rate were carried out and standard solution was injected. Six replicates and system suitability tests were performed and the validation parameters indicated above were evaluated. Solution stability For mobile phase stability, mobile phase was prepared and stored in a refrigerator. The analysis was performed using freshly prepared sample and standard solutions on the first and second day. For sample solution stability, sample and standard solutions were prepared at specification level and stored in a refrigerator. The analysis was performed using freshly prepared mobile phase on the first and second day. RESULTS Kromasil C18 column and mobile phase containing 0.02M ammonium acetate (ph 4.0), 10 % methanol in acetonitrile (60:40) were found to be suitable for analysis of both venlafaxine and modafinil. The other chromatographic conditions optimized were flow rate of 1.0 ml/min, detection wavelength of 225nm, column temperature of 40 o C, injection volume of 20 ml, diluent methanol:water (50:50, v/v), and a run time of 10 min. System suitability To check the system and column performance, the standard solution was injected six times and the following parameters were monitored. System suitability results are shown in Table 1. Tailing factor was < 1.5 for both venlafaxine and modafinil. Theoretical plates were 4500 for venlafaxine and 5500 for modafinil. %RSD of retention time and peak area was < 1 % for both venlafaxine and modafinil. Table 1: System suitability results Parameter Venlafaxine Modafinil % RSD of retention time 0.35 0.46 % RSD of peak area 0.61 0.39 Tailing Factor 1.42 1.13 Theoretical Plates 4563 5621 Specificity The sample and standard chromatograms were identical. There were no peaks in both blank and placebo chromatograms which shows that there was no interference of excipients in the analysis of the drugs. Typical chromatograms are shown in Fig 1. Precision and intermediate precision The %RSD values of venlafaxine and modafinil for method precision were 0.71 and 0.58 respectively but for intermediate precision these are 0.83 and 0.84 for venlafaxine and modafinil respectively. Linearity Venlafaxine and modafinil showed linearity in the range 1-50 μg/ml, and was represented by the following linear regression equations: Y = 34918X + 1013 (r 2 =0.9998), Y = 26759X + 3286 (r 2 =0.9998), respectively. Accuracy Recoveries of venlafaxine and modafinil were between 98.0 and 102.0 %, indicating good accuracy of the developed method. The results are shown in Table 3. Robustness In all cases where deliberate changes were made to the procedure, no significant changes were observed in the results. %RSD of peak area and retention time were < 1 %. The results are shown in Table 4. Solutions stability The drug solution and mobile phase were stable up to 48 hours in refrigerated condition. There was not much change in assay value; the results are shown in table no 5. Trop J Pharm Res, April 2013;12 (2): 241 6

Figure 1: Typical chromatograms Table 2: Precision and intermediate precision (ruggedness) data Parameter Venlafaxine Modafinil Average 99.83 100.04 Precision %RSD 0.71 0.58 Intermediate Precision Average 99.67 99.89 %RSD 0.83 0.84 Table 3: Accuracy (% Recovery) results Venlafaxine Modafinil % Conc. Amount Amount % Amount Amount % added found Recovery added found Recovery (µg/ml) (µg/ml) (µg/ml) (µg/ml) 80 5.00 4.98 99.60 5.00 4.97 99.40 100 10.00 9.92 99.20 10.00 9.95 99.50 120 15.00 14.93 99.53 15.00 14.96 99.73 Trop J Pharm Res, April 2013;12 (2): 242 7

Table 4: Results of robustness ph variation 3.9 4.0 4.1 Venlafaxine Modafinil Venlafaxine Modafinil Venlafaxine Modafinil % RSD R t 0.53 0.41 0.58 0.71 0.65 0.53 % RSD area 0.61 0.47 0.48 0.66 0.69 0.77 T. Factor 1.44 1.11 1.49 1.14 1.53 1.08 T. Plates 4398 5098 4456 5215 4396 5172 Variation of mobile phase composition 65: 35 60:40 55:45 % RSD R t 0.38 0.42 0.46 0.62 0.71 0.38 % RSD area 0.47 0.53 0.34 0.49 0.64 0.47 T. Factor 1.45 1.09 1.51 1.14 1.63 1.21 T. Plates 4231 5341 4837 5169 4657 5481 Temperature variation 35 o C 40 o C 45 o C % RSD R t 0.58 0.64 0.38 0.71 0.44 0.53 % RSD area 0.71 0.52 0.63 0.46 0.52 0.51 T. Factor 1.61 1.09 1.44 1.11 1.37 1.15 T. Plates 4326 5312 4609 5423 4281 5257 Flow variation 0.8 ml/min 1.0 ml/min 1.2 ml/min % RSD R t 0.45 0.56 0.39 0.41 0.53 0.67 % RSD area 0.79 0.82 0.53 0.36 0.72 0.61 T. Factor 1.51 1.21 1.44 1.15 1.48 1.17 T. Plates 4376 5412 4672 5481 4486 5347 Table 5: Solution and mobile phase stability data Solutions Stability Assay of Samples % Variation Initial 1 st day 2 nd day 1 st day 2 nd day Venlafaxine 99.12 99.07 98.87 0.05 0.25 Modafinil 99.33 99.08 98.67 0.25 0.66 Mobile phase stability Venlafaxine 99.12 98.82 98.75 0.30 0.37 Modafinil 99.33 99.12 98.88 0.21 0.45 DISCUSSION Venlafaxine and modafinil are structurally close and have similar polarities. Both drugs were analysed by reverse phase HPLC on commercial C18 columns, using 0.05M ammonium acetate and 0.01M potassium dihydrogenorthophosphate buffers with organic modifiers, viz, methanol and acetonitrile. Inertsil C18 did not show any selectivity for the compounds. Analysis was tried on a Kromasil C18 (4.6 mm x 250 mm i.d, 5 µm particle size) column, using 0.05M ammonium acetate buffer and methanol as well as methanol/acetonitrile in varying proportions. In methanol alone, modafinil was not eluted, but when acetonitrile was added, modafinil was eluted (as acetonitrile content increased) and the retention times were high. The compounds were analyzed on Waters C18, (4.6 mm x 250 mm i. d, 5µm), using buffers, methanol and acetonitrile in different proportions. The mobile phase containing 0.05M ammonium acetate buffer and 10 % methanol in acetonitrile eluted both compounds in less time, with good peak symmetric properties. The concentration of the organic modifier, buffer ph and column temperature were optimized to separate the two compounds with good resolution in less time. For efficient analysis of the compounds, various concentrations of acetonitrile were studied. At lower concentrations, it took a longer time for elution of the compounds. Also, there was a slight increase in tailing factor as concentration increased. Studies were carried out on the effect of buffer ph on tailing factor and retention times. There was a slight increase in tailing of compounds, while the retention time for venlafaxine increased and resolution decreased as buffer ph increased Trop J Pharm Res, April 2013;12 (2): 243 6

from 3.0 to 5.0. At ph 4.0, symmetrical peaks with good resolutions were obtained. The column was maintained at different temperatures ranging from 25 to 50 C. Tailing was reduced with increasing temperature for venlafaxine and a slight increase was observed for modafinil. Retention times decreased slightly with increasing temperature, but the peaks became sharp, and resolution was good for the compounds at 40 C. Good symmetrical peaks were obtained with the mobile phase, 0.05M ammonium acetate (ph 4.0): 10 % methanol in acetonitrile (60:40 v/v) on Waters C18 (4.6 mm x 250 mm) column maintained at 40 C. Flow rate was kept at 1.0ml/min. The UV overlaid spectra of both venlafaxine hydrochloride and modafinil showed that both drugs absorb appreciably at 225 nm; hence, 225 nm was selected as the detection wavelength. The retention time of venlafaxine hydrochloride was 4.4 min and that of modafinil 6.3 min. Asymmetric factor for venlafaxine hydrochloride was < 1.5 and for modafinil, it was < 1.2. Relative standard deviation (% RSD) of retention times (Rt) and peak areas were < 1 and means of tailing factor (> 2), resolution factor (> 2) and theoretical plates (> 2000) were well within the limits, hence the method passed system suitability tests. There was no interference of excipients with the analysis of the drugs. The standard and sample chromatograms were identical, which proves that the method is specific. The mean amount of drugs was 99.83 and 100.04 % for modafinil and venlafaxine, respectively. When analysis was performed by a second analyst on a second system, RSD was < 1 %,, which proves the precision of the method. The method showed good linearity for both venlafaxine and modafinil. The method is robust and unaffected by small variations in test conditions. The method also satisfied stability requirements. CONCLUSION A simple and accurate reverse phase HPLC method has been developed for the determination of venlafaxine and modafinil. The method was validated as per ICH guideline in terms of specificity, precision, accuracy, linearity, limit of detection, ruggedness, robustness and solutions and mobile phase stability. A single method can thus be used for the routine analysis of venlafaxine and modafinil in dosage forms. REFERENCES 1. Goodman & Gilman s, The Pharmacological Basis of Therapeutics, 11th edn, McGraw Hill Medical Publishing Div, London, 2005; pp 447-485. 2. Holliday MS, Benfield P. Venlafaxine. A Review of its Pharmacology and Therapeutic Potential in Depression. Drugs.1995; 49(2): 280-294. 3. Madras BK, Xie Z, Lin Z, Jassen A, Panas H, Lynch L, Johnson R, Livni E, Spencer TJ, Bonab AA, Miller GM, J. Fischman A. Modafinil Occupies Dopamine and Norepinephrine Transporters in Vivo and Modulates the Transporters and Trace Amine Activity in Vitro. J Pharmacol Exp Ther. 2006; 319(2): 561 569. 4. Raut BB, Kolte BL, Deo AA, Bagool MA, Shinde DB. A rapid and sensitive high performance liquid chromatographic method for determination of venlafaxine and o-desmethyl venlafaxine in human plasma with UV detection. J Liq Chromatogr Technol. 2003; 26(8): 1297-1313. 5. Asafu-Adjaye EB, Faustino PJ, Tawakkul MA, Anderson LW, Yu LX, Kwon H. Validation and application of a stability-indicating HPLC method for the invitro determination of gastric and intestinal stability of venlafaxine. J Pharm Biomed Anal. 2007; 47(5): 1854-1859. 6. Purdel NC, Balalau D, Ilie M, Arama CC. Determination of Venlafaxine Toxic Levels From Human Serum by Non-Aqueous Capillary Electrophoresis. Farmacia 2010; 58(1): 62-69. 7. Cherkaoui S, Rudaz S, Veuthey J. Non-aqueous capillary electrophoresis- mass spectrometry for separation of venlafaxine and its phase I metabolites. Electrophoresis 2001; 22(3): 491-496. 8. Makhija SN, Vavia PR. Stability indicating LC method for the estimation of venlafaxine in pharmaceutical formulations. J Pharm Biomed Anal. 2002; 28(6): 1055-1059. 9. Kaur J, Srinivasan KK, Joseph A, Gupta A, Singh Y, Srinivas SK, Jain G. Development and validation of stability indicating method for the quantitative determination of venlafaxine hydrochloride in extended release formulation using high performance liquid chromatography. J. Pham. Bioall Sci. 2010; 2(1): 22-26. 10. Burnat P, Robles F, Do B. High-performance liquid chromatographic determination of modafinil and its two metabolites in human plasma using solidphase extraction. J Chromatogr B Biomed Sci Appl. 1998; 706(2): 295-304. 11. Moachon G, Matinier D. Simultaneous determination of modafinil and its acid metabolite by highperformance liquid chromatography in human plasma. J Chromatogr B Biomed Appl. 1994; 654(1): 91-96. 12. Schwertner HA, Kong SB. Determination of modafinil in plasma and urine by reversed phase high performance liquid-chromatography. J Pharm Biomed Anal. 2005; 37(3): 475-479. 13. Gorman SH. Determination of modafinil, modafinil acid and modafinilsulfone in human plasma utilizing liquid liquid extraction and high-performance liquid chromatography. J Chromatogram B Anal Tech Biomed Life Sci. 2002; 767(2): 269-276. 14. Schwertner HA, Kong SB. Determination of modafinil in plasma and urine by reversed phase highperformance liquid-chromatography. J Pharm Biomed Anal. 2005; 37(3): 475-479. 15. Swetha K, Mohideen S, Satyanarayana T, Narasimha RCH, Suresh KP, Shyamala M. Determination and Validation of Modafinil in Pharmaceutical Formulation by RP-HPLC Int Res Pharm and Biomel Sci., 2011; 2(4): 1837-1840. Trop J Pharm Res, April 2013;12 (2): 244 6

16. Bhimanadhuni CNR, Garikapati DR, Karamsetty S. Development and Validation of RP-HPLC method for determination of Modafinil in bulk and dosage form. Int C PharmJ. 2012; 1(4): 77-80. Trop J Pharm Res, April 2013;12 (2): 245 7