The information contained in this document is intended for healthcare professionals only.

Similar documents
The information contained in this document is intended for healthcare professionals only.

MicroSeal Total Hip Acetabular System. Like Nothing Else

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Stability without compromise. Epsilon Durasul Constrained Insert

Trilogy Acetabular System

The Leader in Orthopaedic Innovation

Trilogy Acetabular System

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

MARATHON Cross-Linked Polyethylene

Constrained Acetabular Insert

Trinity. Advanced Bearing Acetabular System Surgical technique

G7 ACETABULAR SYSTEM. beautifully. efficient.

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Manza Cup HA SURGICAL TECHNIQUE.

Longevity Offset and Oblique Liners. Surgical Technique

Optimum implant geometry

Optimum implant geometry

Restoration Anatomic Acetabular System Surgical Technique

PINNACLE REVISION CUP SYSTEM

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

OPTIONAL/ADDITIONAL INSTRUMENTS

ACETABULAR CUP SURGICAL TECHNIQUE

Understanding Hip Implant Options

FMP Surgical Technique

Trident Constrained Acetabular Insert Surgical Protocol

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Hip Product Brochure

Versatility in a proven design. Trilogy Acetabular System

Tritanium Acetabular System Surgical Protocol. Cluster Hole Shell Solid Back Shell

PyroCarbon Implants Durability + Biocompatibility

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

System Surgical Protocol

Optimum implant geometry

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Exeter. Technical Guide

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

TOTAL HIP REPLACEMENT:

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Surgical Technique. Cup System

*smith&nephew EP-FIT PLUS Cementless Press-Fit Cup System. Product Information

Bone Bangalore

Arcos Modular Femoral Revision System

Duraloc CONSTRAINED LINER

MULTIPOLAR BIPOLAR CUP. Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

Restoration Modular Revision Hip System. Choice Matters

Dual Mobility System Evaluation surgical technique

Dual Mobility System Surgical technique

Mako Total Hip Direct anterior approach

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Featuring. Technology. Product Rationale

PLR. Proximal Loading Revision Hip System

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

SELF-CENTERING Bipolar/Modular Cathcart Unipolar

ADM X3 Mobile Bearing Hip. System Surgical Protocol. Available with X3 Advanced Bearing Technology. For Use With Restoration ADM Cups and Inserts

D E S I G N R A T I O N A L E

Operative Technique Crown Cup Acetabular System

Trilogy Acetabular System

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Bone Preservation Stem

Bi-Polar 22.2mm & 28mm System - Operative technique

Allofit /Allofit -S Alloclassic Acetabular Cup System

REFLECTION Constrained Liner Introduction

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Trident. Acetabular System Hemispherical Surgical Protocol

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Trident All Poly Acetabular System

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

Trabecular Metal Acetabular Revision System Cemented Constrained Liner

One system for all revision types

SURGICAL TECHNIQUE. Pivot Bipolar Solitude Unipolar

RM Philosophy Innovation based on clinical evidence.

Product Portfolio. Consensus Knee Systems. Consensus Hip Systems

Supplementary Appendix

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Reaching new heights. Comprehensive. Efficient. Simple.

CERAMIC-ON-METAL. References: Cat No: version 2

Scan Bi-Polar 22/28. Operative Technique

Design Rationale. ECHELON Primary Hip System

Trident Ceramic Acetabular System Technical Monograph

PAL Pelvic Alignment Level

Aesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics

DURALOC. Acetabular Cup System. Surgical Technique

Trabecular Metal Acetabular Restrictor and Augment

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

ReCap Product Rationale

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

TRABECULAR METAL ACETABULAR RESTRICTOR AND AUGMENT. Surgical Technique

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

R3think your options. For US distribution only.

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells

Transcription:

The information contained in this document is intended for healthcare professionals only.

Trident Hemispherical Acetabular Shell Trident PSL HA Acetabular Shell Featuring:

The Trident Acetabular System has been implanted throughout the world since 1999 and, while commercially available, has also been included in a clinical evaluation through an IDE study in the United States. More than 10,000 Trident shells have been implanted globally and the success of the Trident System continues to expand in the US. All Trident Acetabular Shells feature the Innerchange Locking Mechanism, which provides independent locking of polyethylene or ceramic inserts* into the shell. The Trident Acetabular System offers: Superior locking mechanisms for both polyethylene and ceramic inserts* Crossfire polyethylene for improved wear performance Trident PSL HA Acetabular Shell The Trident PSL Acetabular Shells are designed to maximize fixation in the peripheral lunate region of the acetabulum. Purefix HA coating is featured on all Trident PSL shells. Trident Hemispherical Acetabular Shell The thickest polyethylene on the market Choice of shell geometries Arc-deposited roughened surface to help achieve immediate stability Purefix HA Eccentric and Constrained Inserts for revision options Trident Hemispherical Acetabular Shells are a true hemispherical shape designed to achieve press-fit fixation by under-reaming the acetabulum. *Ceramic is not currently available in the US as of 7/15/2001.

Innerchange Locking Mechanism The Innerchange Locking Mechanism allows for independent locking of polyethylene and ceramic inserts into the shell. This provides superior locking of both inserts without compromise. The Trident polyethylene insert allows for proper rotational alignment using 12 indexable scallops. Polyethylene inserts lock into the shell in three ways: Four alignment studs on the shell provide proper rotational and axial alignment Unique bead and groove mechanism Additional rim locking provides for exceptional insert stability BARB/SCALLOP ENGAGEMENT Innerchange Locking Mechanism POLYETHYLENE PRESS-FIT AT RIM Extensively Tested Locking Mechanism Fully congruent design Independent testing by Alan Litsky, MD, PhD at Ohio State University 1 Robust push-out and lever-out resistance 2 Hip simulation testing with Crossfire polyethylene has demonstrated improved wear performance 3 CONGRUENT DESIGN POLYETHYLENE BEAD/SHELL GROOVE According to Dr. Litsky s study, among the designs from other manufacturers, none is better than the Howmedica Osteonics Trident design in either radial or tilting micromotion. 1

Polyethylene Polyethylene Trident polyethylene inserts are: Fully congruent to the shell Supported by extensive research on range of motion and head stability 10 Available in neutral, hooded and eccentric designs Polyethylene Thickness Polyethylene thickness plays an important role in the wear performance. 4 Size for size, the Trident polyethylene inserts are the thickest in the industry. Shell fully supports the Trident insert Size 56 mm Cup, 28 mm I.D. 10 degree hooded inserts are available with the Trident System (shown here)

Crossfire Highly Crosslinked Polyethylene Crossfire Highly Crosslinked polyethylene has demonstrated significant wear reduction compared to standard polyethylene. Howmedica Osteonics technology and conservative process have allowed increased crosslinking while maintaining the material properties of the polyethylene. 90% reduction in wear 5 Crossfire polyethylene demonstrates 90% reduction in wear over nitrogen sterilized polyethylene in joint simulation testing, thereby reducing the potential for osteolysis. Material properties are retained The material properties of Crossfire polyethylene are similar to those of standard polyethylene, as shown in Figure 1. Preserves the polymer structure of UHMWPE The crystalline and amorphous regions of Crossfire are similar to standard polyethylene which suggests predictable clinical performance 6 (Figure 2). N 2 /Vac packaging provides resistance to oxidation Packaging polyethylene in an oxygen-free environment improves material toughness and strength on shelf-stored polyethylene up to 10 years. 7 Same particle size and shape as standard polyethylene The biological response to Crossfire particles is not expected to be different from standard polyethylene. Figure 1 Crossfire polyethylene maintains similar yield strength, modulus and crystallinity as standard polyethylene. When these properties change significantly, the clinical wear performance cannot be predicted. Crossfire Polyethylene Standard UHMWPE Crossfire Figure 2 Crossfire exhibits a morphology that is very similar to that of standard UHMWPE

LFIT LFIT Technology Improved Wear Performance with LFIT Femoral Head Technology Low Friction Ion Treatment (LFIT ) technology is a bombardment of nitrogen ions onto a CoCr surface, which enhances material properties of the metal, in turn reducing frictional forces against UHMWPE surfaces. LFIT : Improves wettability Reduces coefficient of friction Wettable materials are important in total hip arthroplasty In an anatomic hip joint, the femoral head is cushioned by cartilage, which seeps lubrication into the joint. When the joint is diseased or removed, the natural lubrication surface is also removed, and the femoral head and acetabular insert contact each other. LFIT femoral heads are designed to increase lubrication. Clinical Experience with LFIT The LFIT heads demonstrated a 28% reduction in linear wear over CoCr heads in 110 patients at minimum 3-year follow up 9 (Figure 3). This data coincides with hip simulation testing. 8 These results are encouraging Nitrogen ion implanted femoral heads may be an effective way to decrease UHMWPE wear and increase implant longevity in THA. 9 CoCr CoCr LFIT Wettable materials have a lower boundary angle between a liquid and a solid. Figure 3 LFIT heads demonstrated a 28% reduction in linear wear over CoCr heads

Revision Options A Trident Hemispherical Multi-Hole Acetabular Shell with Purefix HA is available providing increased screw hole options (Figure 4). Eccentric and Constrained Inserts augment the Trident System with revision options to increase surgeon flexibility in complex primary or revision surgery. The Trident Eccentric Inserts feature Crossfire Highly Crosslinked Polyethylene for improved wear performance. 5 The head center is lateralized 6mm from the center of the acetabular shell allowing increased polyethylene thickness and joint stability (Figure 5). Trident Constrained Inserts are available for total hip patients who exhibit a high risk of hip dislocation. Constrained Inserts feature Howmedica Osteonics uniquely designed pre-assembled inserts with the UHR bipolar (Figure 6). Figure 4 Trident Hemispherical Multi-Hole Acetabular Shell Cross-section of Trident Eccentric Insert Cross-section of Trident Constrained Insert CENTER OF SHELL CENTER OF ECCENTRIC INSERT 6mm SAME HEAD CENTER AS STANDARD POLY INSERT Figure 5 Figure 6 0 Eccentric Insert 10 Hooded Eccentric Insert Constrained Insert Revision Options

Compatibility Trident polyethylene inserts may be used with V40 or C-taper femoral heads. The alphabetical letter at the end of all Trident catalog numbers identifies compatibility among all Trident acetabular components. Matching the shell and insert Alpha Codes will ensure proper compatibility. Trident Compatibility Chart Trident Trident Crossfire N 2 /Vac Alpha PSL HA Hemispherical 0 and 10 0 and 10 Code Shell Size (mm) Shell Size (mm) Inserts (mm) Inserts (mm) N/A=not available A 40 42 22 N/A B 42 44 22 N/A C 44 46 22, 26 N/A D 46, 48 48, 50 22, 26, 28 28 E 50, 52 52, 54 22, 26, 28, 32 28 F 54, 56 56, 58 22, 26, 28, 32 28 G 58, 60 60, 62 22, 26, 28, 32 28 H 62, 64 64, 66 22, 26, 28, 32 28 I 66, 68 68, 70 22, 26, 28, 32 28 J 70, 72 72, 74 22, 26, 28, 32 28 References 1 Litsky, AS, et al, Micromotion Between the cup and the Liner in Modular Acetabular Prostheses, 1999 Society for Biomaterials, 25th Annual Meeting Transactions. 2 Data on file at Howmedica Osteonics. 3 Schmidig G, et al, Trident Polyethylene Acetabular Insert Performance Characteristics, Howmedica Osteonics Literature #LTAP/TM. 4 Jasty, M, et al, Wear of Polyethylene Acetabular Components in Total Hip Arthroplasty, JBJS, 70A, March 1997. 5 Taylor, S, Advances in Polyethylene: Crossfire, Howmedica Osteonics Literature #LSA23. 6 Dumbleton, JH, Edidin, AA, A Highly Crosslinked Oxidation-Resistant Polyethylene: Crossfire, Howmedica Osteonics Literature #LSA29. 7 Edidin, AA, et al, Gamma Sterilization in Nitrogen Prevents Degradation for More Than 10 Years, Trans. ORS, p. 1, 2000. 8 Taylor, S, Reduction in Polyethylene Wear through Ion-Implantation into CoCr Alloy, Surface Modification Technologies VI, The Minerals, Metals & Materials Society, 1993. 9 Maruyama, M, et al, Effect of Low Friction Ion Treated Femoral Heads on Polyethylene Wear Rates, CORR, Number 370, pp. 183-191. 10 Dong, et al, Hip Joint Stability Determined by Acetabular Bearing Insert Design, An in-vitro Simulated Study, ORS, 1999. Stryker is a registered trademark of Stryker Corporation. Crossfire, PSL,Trident and UHR are registered trademarks of Howmedica Osteonics Corp. Innerchange, LFIT, N 2 /Vac, Purefix, and V40 are trademarks of Howmedica Osteonics Corp. Hylamer, PFC, and Reflection are not registered trademarks of Stryker Corporation. Duraloc and Trilogy are not trademarks of Stryker Corporation. U.S. Patent No.: 4,798,610 Patent Pending for Innerchange. Howmedica Osteonics 2001 Lit. No. LTS/B 5M 7/01 7399 TG/ITP C Printed in USA on recycled paper. 359 Veterans Boulevard Rutherford, NJ 07070 59 Route 17 South Allendale, NJ 07401 www.howost.com