PARIETEX COMPOSITE 10 YEAR ANNIVERSARY

Similar documents
Ventralex ST Hernia Patch featuring Sepra Technology

3/21/2011. Advances in laparoscopic ventral hernia repair. Laparoscopic approach well-suited for simple hernias:

Tissue-Separating Mesh A Comparative Guide

Early View Article: Online published version of an accepted article before publication in the final form.

Meshes. Meshes. Non-absorbable meshes. Absorbable meshes

OptiFix Absorbable Fixation System

VALUE ANALYSIS COMMITTEE PRODUCT INFORMATION KIT

Mædica - a Journal of Clinical Medicine STATE-OF-THE-ART. , Danut VASILE. University of Medicine and Pharmacy Carol Davila Bucharest, Romania

Evidence Summary. Ethicon Hernia Portfolio. Better surgery for a better world

II.- PLUG. NAME of the products. Premilene Mesh Plug MANUFACTURER. B Braun DESCRIPTION. Polypropylene mesh for plug technique

Designed to help advance patient outcomes and ease of use

Glue for mesh fixation in laparoscopic ventral hernia repair. An experimental comparison with conventional fixation.

7/2/2015. Incidence. *Mudge M et al, Br. J. Surg, 1985, 72:70-71

Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

STOMA SITING & PARASTOMAL HERNIA MANAGEMENT

SCIENTIFIC PAPER ABSTRACT INTRODUCTION METHODS

B. Braun Mesh Range It s All about Prevention. Experts in Abdominal Wall Health. Hernia Repair

Technique Guide. Bard MK Hernia Repair. Featuring Modified Onflex Mesh SOFT TISSUE REPAIR. Anterior Approach to a Preperitoneal Inguinal Hernia Repair

Cytoflex Barrier Membrane Clinical Evaluation

Research Article Adhesions to Mesh after Ventral Hernia Mesh Repair Are Detected by MRI but Are Not a Cause of Long Term Chronic Abdominal Pain

INSTRUCTIONS FOR USE FOR:

JMSCR Vol. 03 Issue 08 Page August 2015

Adverse Event Reports Relating to Surgical Mesh Implants

Tutopatch and Tutomesh

Laparoscopic repair of incisional and ventral hernias with the new type of meshes: randomized control trial

Adverse Event Reports Relating to Surgical Mesh Implants. Summary of reports received by Medsafe

Title at a Single Institution. Issue Date Right.

Colorectal procedure guide

Laparoscopic Hernia Repair, Indications, Superiority and Outcome

Information from the MAUDE Database

Titanised mesh implants for hernia surgery TiMESH TiLENE Blue TiLENE TiSURE

Farah S, Kiyingi A, Leinkram C. The Melbourne Hernia Clinic Masada Hospital 26 Balaclava Road St Kilda East Victoria, Australia 3168.

Biodesign E NTEROCUTANEOUS FISTULA PLUG

with Laparoscopic Ventral Hernia Repair Positioning System SOFT TISSUE REPAIR Designed for Accurate Mesh Centering

Comparison of adhesion-preventing meshes in a rat model of incisional hernia in terms of intra-abdominal adhesions and other complications

Ventral Hernia Repair

Inadvertent Enterotomy in Minimally Invasive Abdominal Surgery

NiTiNol Hernia Device Stability in Inguinal Hernioplasty Without Fixation

Adverse Event Reports Relating to Surgical Mesh Implants. Summary of reports received by Medsafe

Prevention and Surgical management of Parastomal hernias; When to treat?

CHAU KHAC TU M.D., Ph.D.

MOVE BEYOND. to new hope for enterocutaneous fistulas. Enterocutaneous Fistula Repair

Hernias Umbilical Hernia When to See a Surgeon? What Are Symptoms of an Umbilical Hernia? How is Repair Performed?

Stop Coping. Start Living. Talk to your doctor about pelvic organ prolapse and sacrocolpopexy

Light weight meshes in incisional hernia repair

Expert Technologies in PVDF

The Emergency Hernia or The call you don t want at 2:00 a.m.*

REINFORCED BIOSCAFFOLDS

Setting The study setting was tertiary care. The economic study was carried out in the USA.

Titanised mesh implants for urogynaecology Transvaginal multi-arm meshes Incontinence tapes Instruments Laparoscopic meshes

Echo PS Positioning System with Ventralight ST Mesh or Composix L/P Mesh

Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix

Perineal hernia different surgical approaches and treatment techniques. A case report

Pelvic Prolapse. A Patient Guide to Pelvic Floor Reconstruction

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2013): 4.

Abstract. Med. J. Cairo Univ., Vol. 82, No. 1, September: ,

INGUINAL HERNIA REPAIR PROCEDURE GUIDE

The use of peritoneal flaps in the repair of large incisional hernia

Science Journal of Clinical Medicine

PAPER. Long-term Complications Associated With Prosthetic Repair of Incisional Hernias

(12) United States Patent (10) Patent No.: US 6,383,201 B1

Titanized Mesh Implants Hernia Surgery

What You Should Know About Pelvic Adhesions & Gynecologic Surgery

This information is intended as an overview only

ARTIFICIAL MESH REPAIR FOR TREATMENT OF PELVIC ORGAN PROLAPSE

Single-incision laparoscopic parastomal hernia repair employing fascial defect closure and sandwich technique

INCISIONAL HERNIAS. Contents What is an Incisional Hernia?... 3

1. Introduction. 2. Material and methods Methodology

Hybrid technique for postoperative ventral hernias own experience

Guided Tissue and Bone Regeneration

Research Article Parastomal Hernia Repair with Intraperitoneal Mesh

Hernia. emoryhealthcare.org

Ultrapro Hernia System Bi Layer Dr Cosmas Gora T SpB-KBD. dffdfdfxxgfxgfxgffxgxgxg

Colostomy & Ileostomy

Suture Versus Tack Fixation of Mesh in Laparoscopic Umbilical Hernia Repair

Cordis EXOSEAL Vascular Closure Device

Case Report. XCM Biologic Tissue Matrix. Components separation using sandwich technique for reconstruction of abdominal wall defect.

Robotic Ventral Rectopexy

Transabdominal pre peritoneal (TAPP) vs totally extraperitoneal (TEP) laparoscopic techniques for inguinal hernia repair

2015 General Surgery Survival Guide

SURGICAL TREATMENT OF INCISIONAL HERNIAS

US FDA/CDRH: Public Health Notification: Serious Complications Associated with Transvaginal Place... FDA Home Page CDRH Home Page Search A-Z Index

Fish Skin Grafts Promote Superior Cell Ingrowth Compared to Amnion Allografts, Human Cadaver Skin and Mammalian Extracellular Matrix (ECM)

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

Bard CapSure. Technique Guide. Permanent Fixation System SOFT TISSUE REPAIR. Laparoscopic Inguinal, Open and Laparoscopic Ventral Hernia Repair

PERMACOL IMPLANT EVIDENCE SUMMARY

Ethicon Women s Health & Urology eclinical Compendium Article Summary

Focus on: IMPLANT TESTING ISO

Mesh migration Should it be a mandatory consentable complication?

From the Unit of General and Geriatric Surgery, School of Medicine, Department of Surgery, Second University of Naples, Italy

Open abdomen in trauma. Ari Leppäniemi Abdominal Center Meilahti hospital University of Helsinki Finland

REGENERATIVE OF THE BLADDER WALL FOR THE TREATMENT OF A BIOABSORBABLE POLYMER SHEET

Pelvic Organ Prolapse. Natural Solutions

CorMatrix ECM Bioscaffold

Randomized clinical trial of laparoscopic hernia repair comparing titanium-coated lightweight mesh and medium-weight composite mesh

Index. Note: Page numbers of article title are in boldface type.

Hernia repair: the search for ideal meshes

COMPLICATIONS OF HERNIA REPAIR

PROCEED Surgical Mesh Product Information Kit

Peritoneal Dialysis Catheter Placement. Peritoneal Dialysis Catheter Placement. Peritoneal Dialysis Catheter Placement

Transcription:

PARIETEX COMPOSITE 10 YEAR ANNIVERSARY 1999-2009 10 YEARS OF CLINICAL EVIDENCE

THE CONCEPT Polyester mesh takes on the challenge of hernia repair with material and manufacturing innovations to optimize healing and comfort through fast and intimate tissue in-growth. The new architecture of hernia repair features an enhanced hydrophilic, multi-filament construct and optimal porosity. Studies show that polyester is superior to other materials, such as polypropylene and eptfe, in lack of shrinkage, advanced rate of healing and improved patient comfort. Optimized Material - hydrophilic polyester enhances rapid tissue in-growth rapid and complete tissue integration is an important requirement for an optimal hernia repair mesh 1. To answer this need, our technology begins with a material difference polyester. When this material is designed with optimum pore size it enhances fast and intimate tissue ingrowth. Polyester promotes the attraction, fixation and survival of young fibroblasts and mesothelial cells due to its hydrophilic nature. In contrast, polypropylene and eptfe tend to repel all cells and avoid the fixation of all living cells to the material because of their hydrophobic characteristic. When a hydrophobic material like polypropylene, which do not promote the attraction of cells, is combined with a small-pore, size a common result is encapsulation of the mesh with scar tissue. Optimized Structure porosity promotes connective tissue differentiation. To allow fast and intimate tissue in-growth without any peripheral fibrous capsule (which can cause shrinkage, discomfort and chronic pain), a mesh must also have porosities that are as large as possible 5.Pore sizes below 1 mm trigger an intense inflammatory response. Inflammation and scar formation lead directly to encapsulation which in turn leads to contraction. Parietex technology creates both micropores for optimized cellular in-growth between the fibers and large macropores for true connective tissue differentiation. Parietex s porosity allows the right amount of connective tissue in-growth with no fibrotic encapsulation or degradation. Preventing Visceral Attachments Intraperitoneal placement of the mesh represents a real advance in the ventral hernia repair: it facilitates laparoscopic treatment of small incisional hernia repair. The result is a reduction of operative time that benefits the patient by decreasing of surgical and anesthetic morbidity. When placing a mesh intraperitoneally it must provide a permanent or temporary interface between normally separated structures. The requirements for an ideal mesh are: To physically separate anatomical structures during the early healing phase To induce a minimized inflammatory response in order to reduce both encapsulation and adhesions to the barrier itself To restore normal cleavage plans Parietex Composite (PCO) Mesh is composed of three-dimensional polyester structure on the parietal side and an absorbable collagen film on the visceral side.

PCO Series (Laparoscopy Surgery) PCO OS Series (Open Surgery) Parietex Composite Hiatal Mesh Parietex Composite Parastomal Mesh A proprietary manufacturing process creates a strong link between the film and the threedimensional polyester structure (picture 1) which eliminates the risk of delamination that has been reported in other meshes. Picture 1. The continuous, smooth, hydrophilic and resorbable collagen film is composed of a mixture of oxidized atelocollagen type I, polyethylene glycol and glycerol. The hydrogel film s physico-chemical properties: hydrophilicity, elasticity and transparency make it easy for surgeons to implant the mesh intraperitoneally. Moreover, the film extends 5 mm over the mesh edges providing additional protection. Before resorption of the hydrogelic film Hydrogelic film Mesh superficial thread Mesh deep thread Abdominal wall Transversal section 1 week after implantation Neoformed mesothelial layer Parietex Composite (PCO) Mesh provides a temporary barrier and the film s hydrophilicity promotes the attraction of mesothelial cells. After absorption it leaves a neo-peritoneum composed by mesothelial cells that will prevent visceral attachments. After resorption of the hydrogelic film Mesh superficial thread Continuous neoperitoneum Mesh deep thread Abdominal wall Transversal section 6 weeks after implantation Differentiated tissue in-growth Intimate attachment of the mesh to the wall

CLINICAL RESULTS An optimal balance of properties backed the largest portfolio of clinical studies. Study # Adhesion Integration Shrinkage Degradation Pain Infection Elasticity Balique 1 X X X Chelala 2 X X X Burger 3 X X Jacob 4 X X X Duffy 5 X X McGinty 6 X X X Clavé 7 X Bracco 8 X Ramshaw 9 X Junge 10 X X Gonzales 11 X Schreinemacher 12 X X Köckerling 13 X X Junge 14 X X X Rosen 15 X ADHESION PREVENTION Study 1. 80 patients were included in this prospective multicenter clinical trial. The main objective was to evaluate the antiadhesive properties of Parietex Composite (PCO) Mesh. Ultrasound (US) specific examinations of intestinal movement was initially validated (pre-operative prediction vs. Preoperative findings) and then used during the followup. After 12 months, 86% of the patients were ultrasonically adhesion free. There was 0% occlusion and fistula. Late complications were: mesh sepsis (1%), new defects (4%) and recurrence (2.5%). At four years, 56 patients (75.7%) were clinically evaluated with a mean follow-up of 48±6 months. One direct recurrence was noted while six patients experienced new defect outside the mesh. No long-term severe complication such as occlusion or enterocutaneous fistula was observed. Study 2. In this retrospective study, the author evaluated a minimally invasive surgical technique of moderate to large incisional and ventral hernia defects using Parietex Composite (PCO) Mesh. The midterm results for 400 patients are presented in terms of efficacy and safety. On 400 patients, no major complications were observed, 0 small bowel obstruction, 0 enterocutaneaous fistula and 0 infections. A second look study (for other indications) was performed on 35 patients (8.75%) 3 to 13 months postoperatively that confirms the global results. The majority (23 patients, 65.71%) were adhesion free. Some had loose adhesions of the omentum (grade 1 of Mueller s classification; n = 10), and the remainder had easily cleavable serosal adhesions (grade 2 of Mueller s classification; n = 2) There were no cases of chronic infection, small bowel obstruction, fistula, or hernia fistula, and no conversions occurred in this study.

Study 3 In an experimental rat study, the authors wanted to evaluate adhesion formation with different types of currently available composite meshes. Eight different meshes were placed intraperitoneally and in direct contact with abdominal viscera in 200 rats. The following meshes were tested: polypropylene (Ethicon's Prolene*), eptfe (Gore's Dualmesh ), polypropylene polyglecaprone composite (Ethicon's Ultrapro*), titanium polypropylene composite (GfE's Timesh ), polypropylene with carboxymethylcellulose sodium hyaluronate coating (Bard* Sepramesh*), polyester with collagen-polyethylene glycol glycerol coating (Parietex Composite), polypropylene polydioxanone composite with oxidized cellulose coating (Ethicon's Proceed ), and bovine pericardium (Tutogen Medical's Tutomesh ). Adhesion formation, mesh incorporation, tensile strength, shrinkage, and infection were evaluated at 7 days and 30 days. At 7 days and 30 days, Parietex Composite resulted in significantly less adhesions (3.9% and 11.2% respectively) than observed with other meshes except Tutogen Medical's Tutomesh and Bard* Sepramesh* Duamesh Timesh Ultrapro Prolene Proceed Sepramesh PCO Tutomesh Study 4. Adhesion surface at 30 days 0 10 20 30 40 50 60 This prospective, randomized animal study compared shrinkage, adhesions and tissue ingrowth between Parietex Composite (PCO) Mesh, Ethicon's Proceed and uncoated polypropylene. 3 different 10x15 meshes were implanted in 10 pigs and then evaluated after 28 days. The mean area of adhesions to Parietex Composite (PCO) Mesh (11%) was significantly less than for Ethicon's Proceed (48%; p< 0.008) or PPM (46%;p < 0.008) % Adhesion peel strength was significantly less for PCO (5.9 N) than for Ethicon's Proceed (12.1 N; p < 0.02) or PPM (12.9 N; p < 0.02) 60% 50% 40% 30% 20% 10% 0% Study 5. In this prospective animal study Parietex Composite (PCO) Mesh and Bard's Composix E/X (Bard) were implanted in female Yorkshire swine and evaluated in terms of adhesion and tissue integration. The meshes were analyzed at 28 days post implantation by a veterinary pathologist who was blinded to the data. At 28 days, PCO induced fewer adhesions than eptfe mesh (14.5% vs 53.4%, P=0.007). On an adhesion scale (0 5), we had 1.75 for PCO (P<0.03) vs 3.6 for eptfe Bard's Composix E/X Study 6. 3 types of meshes polypropylene (PPM), expanded polytetrafluoroethylene (eptfe), and polyester with antiadhesive collagen layer (PCO) were implanted laparoscopically in eight pigs using sutures and tacks for fixation. Adhesion formation, fibrous ingrowth and shrinkage were evaluated after 28-day survival. Percentage of mesh area with adhesions @ 28 days Mean area of adhesions to PCO (8.25%) was less than that to eptfe (57.14%, p < 0.001) or PPM (79.38%, p < 0.001). Adhesion peel strength was less for PCO (2.3N) than for PPM (16.1 N, p < 0.001) or eptfe (8.8 N, p = 0.02). Study 11 PCO Proceed PPM The purpose of this prospective animal study was to compare the effectiveness of five meshes which had been developed to resist adhesion formation to that of an untreated mesh after 21 days following surgery. 5 composite mesh products (Parietex Composite, Parietene Composite, Bard Bard's Composix E/X, Bard * Sepramesh *, and Gore- Tex Gore's DualMesh ) and one untreated mesh product (Parietene ) were implanted in 80 rats.

After 21 days, adhesion formation was evaluated and Parietex Composite exhibited the lowest rate of adhesions with 8.3%, with non significance difference with other meshes except for Sepramesh and the untreated mesh. Untreated Parietene Control Sepramesh Gore-Tex Dual Mesh Bard Composix E/X Parietene composite Adhesion rate in % Parietex Composite (PCO) and Atrium's C-QUR showed the lowest score of adhesion compared to the other meshes with statistical difference. Only Parietex Composite (PCO) showed no visceral adhesions at 30 days. Study 13 3 different composite meshes were laparoscopically implanted in six swine (FEG's Dynamesh IPOM, Ethicon's Proceed, Parietene Composite). Parietene Composite has the same antiadhesive film than Parietex Composite. Parietex composite Study 12 0 10 20 30 40 50 60 70 80 90 100 Comparison of adhesion formation between mesh products. Adhesion rate (%) This study examined the ability of different coated and uncoated meshes to attenuate adhesion formation. 6 meshes were placed intraperitoneally in rats: Ethicon's Prolene* (polypropylene), GfE's Timesh (polypropylene with titanium), Ethicon's Ultrapro % After 4 months, adhesion incidence and adhesion coverage were measured. Adhesion values were 12.8% for Parietene Composite, 31.7% for Ethicon's Proceed and 33.2% for Dynamesh IPOM (p = 0.01). Study 14 4 differents meshes PVDF+PP (FEG's Dynamesh ), PP+Col (Parietene Composite), eptfe (Dual mesh) and PP (a pure polypropylene mesh serving as control) were implanted in 40 rats. Parietene Composite has the same antiadhesive film than Parietex Composite. Adhesion rate, tissue integration and shrinkage were evaluated after 30 days. (polypropylene composites with polyglecaprone), Ethicon's Proceed (polypropylene mesh coated with a layer of cellulose) and Parietex Composite and Atrium's C-QUR (polypropylene mesh coated with a layer of omega-3 fatty acids). Parietene Composite (PCO) adhesion rate was (26.8 ± 12.1%) and the PVDF+PP mesh (34.6 ± 8.2%). Adhesions and incorporation were evaluated macroscopically and microscopically after 7 and 30 days.

TISSUE INTEGRATION Study 3 Parietex Composite (PCO) showed at 7 days and 30 days the highest tissue incorporation. Parietex Composite (PCO) showed the highest tensile strength (14.2 N) Study 4 Peak peel strength from the abdominal wall was significantly higher for PCO (17.2 N) than for Ethicon's Proceed (10.7 N) or PPM (10 N; p < 0.002) Tutomesh Dualmesh Timesh Tensile strengh Study 5 Good tissue ingrowth and neovascularisation had been observed in both meshes, although PCO showed a more complete neoperitoneum. Prolene Proceed Ultrapro Sepramesh PCO 0 2 4 6 8 10 12 14 16 Newton Study 6 Peel strength of mesh from the abdominal wall was greater for PCO (2.8 N/cm, p = 0.001) or PPM (2.1 N/cm, p = 0.05) than for eptfe (1.3N/cm of mesh width).

SHRINKAGE Study 2 Based on the 2 nd look study (35 patients) the author noted the absence of prosthesis shrinking and wrinkling in all these cases confirming its total peritonization on the anterior abdominal wall. Study 3 Parietex Composite (PCO) showed 15.3% at 30 days with no significant difference with other mesh but Tutogen Medical's Tutomesh (44.3%) Study 4 The area of each mesh at the time of insertion was 150 cm 2. PCO (105.8 cm², 29.5%) had less shrinkage than Ethicon's Proceed (99.6 cm², 33.6%) but with no statistically significant difference. Study 6 The area of each mesh at the time of insertion was 150 cm 2. eptfe (94.4 cm 2, 63% of original area) PCO (118.6 cm 2, 79% of original area, p = 0.001) PPM (140.7 cm 2, 94% of original area, p = 0.002). Study 13 Parietene Composite and FEG's Dynamesh IPOM had a similar value of 14% of shrinkage while Ethicon's Proceed showed a 25% reduction in its surface area. Study 14 Parietene Composite (PCO) and FEG's Dynamesh IPOM had a similar value of 19% of shrinkage while Dual mesh showed a 52% reduction in its surface area.

ELASTICITY Study 10 The study showed that at a strain of 16N new ideal meshes should show an elasticity of at least 25% in vertical stretching and 15% in horizontal stretching to achieve almost physiological properties. Relative distension (%) 70 60 50 40 30 20 10 Vertical direction The graphs below show the physiologic elasticity band and the elasticity of several meshes. Parietex and Parietene Composite are above the minimum requirement and don t impair the physiological abdominal wall elasticity. Relative distension (%) 0 0 2 4 6 8 10 12 14 16 18 20 22 24 70 60 50 40 30 20 Horizontal direction 10 0 0 2 4 6 8 10 12 14 16 18 20 22 24 Tensile strengh (N) 3D PET (Parietex Composite) 3D PP (Parietene Composite) 2D Light weight PP (Parietex Light) 2D Heavy weight PP (Prolene )

DEGRADATION Study 7 The objective of the study was to compare the state of alteration of different meshes commonly used in Pelvic Floor Disorder surgery. Multicentric retrospective and comparative study of 100 explanted samples of different meshes: Low Density polypropylene mesh (LDPPMF), High Density polypropylene (HDPPMF), Polypropylene Multifilament, Non- Knotting Non-Woven Polypropylene (NKNW), Polypropylene-polyglactin acid (Composite), Polyethylene Terephtalate (PET). Scanning Electron Microscopy (SEM) analysis was performed on each explanted meshes. SEM analysis has shown 39% of impaired meshes. All Polypropylene meshes 44.5%: LDPPMF 21% HDPPMF 47.8% Multifilament 75% Composite 87.5% NKNW 100% PET 0% PP mesh PP mesh PET mesh Study 8 SEM analysis was performed on 25 explanted meshes after primary abdominal wall hernia repair. The average period of implant was 32.5 months (range 2 180) Fig. 1 Scanning electron microscopy (SEM) micrograph (1,000x) of fragment #24 polyethylene terephthalate (PET) 100% of PP meshes (2 to 52 months of implantation) showed alterations 0% of PET meshes (36 to 180 months of implantation) showed alteration. Fig. 2 Scanning electron microscopy (SEM) micrograph (1,000x) of fragment #20 polyethylene (PP)

Study 9 14 Polypropylene meshes were removed from patients requiring revision surgery due to chronic pain, recurrence, infection, adhesions, or other complications. PAIN 85% of the explanted meshes showed alterations of their surface (cracks, fissures, and increased surface roughness). Moreover, nearly all meshes showed a decrease of the compliance (from 4 to 30 times more force to fold the mesh than the pristine mesh) Study 1 Pain was reduced to a very low level: 0.2±0.8/10 in the open group and 0.8±1.6/10 in the laparoscopic group. 69% of the patients were totally pain free (VAS= 0) in the open group and 67% in the laparoscopic group. Study 2 Transient pain was experienced by 10 patients (2.5%), and resolved over time with analgesic treatment. After 28 months, 97.5% of our patients were pain free, residual chronic parietal pain was reported for 10 patients (2.5%) INFECTION Study 1 1 mesh sepsis (1%) occurred at 8 months after a series of events on the incision, but it was not related directly to the mesh. Study 2 1 mesh sepsis after day 3 requiring mesh explantation (0.25%). No chronic infection reported. Study 15 This retrospective human study was designed to assess postoperative infections, fistulas, small-bowel obstructions and recurrence rates using Parietex Composite (PCO) Mesh in a complex group of patients. 109 patients had ventral hernias repaired and were tracked for a year. Forty-two (42%) of the patients were being treated for a recurrent hernia and twenty-six (26%) had prior intraperitoneal mesh placement. In the laparoscopic group, there were no delayed mesh infections, fistulas or hernia recurrences during the 14 month follow-up period. In the open group, there were no long term bowel obstructions, fistulas or delayed infections related to the mesh during the 11 month follow up period. Dr Rosen concluded based on his experience with a follow up of approximately 1 year, there does not seem to be an increased risk of mesh infection, bowel obstructions, or enterocutaneous fistulas. Polyester mesh seems to be safe for ventral hernia repair.

References 1. Balique J.G. et al. Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: 4 years results of a prospective multicenter clinical trial. Hernia 2005. 9: 68 74 2. Chelala E et al. The suturing concept for laparoscopic mesh fixation in ventral and incisional hernia repair: a mid term analysis of 400 cases. Surgical Endoscopy, 2006 3. Burger J.W.A et al. Evaluation of new prosthetic meshes for ventral hernia repair. Surgical Endoscopy, 2006. 20: 1320 1325 4. B.P. Jacob et al. Tissue ingrowth and bowel adhesion formation in an animal comparative study: polypropylene versus Proceed versus Parietex Composite. Surgical Endoscopy 2007, 21: 629 633 5. Duffy AJ et al. Comparison of two composite meshes using two fixation devices in a porcine laparoscopic ventral hernia repair. Hernia 2004;8 : 358-364 6. McGinty J.J et al. A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh. Surg Endosc (2005) 19: 786 790 7. Clave A, et al. Study of the Alterations of 100 Meshes Excised for Complications after Stress Urinary Incontinence or Pelvic Organ Prolapses Surgery. Journal of Minimally Invasive Gynecology 15 (2008) S1eS159 8. P. Bracco et al. Comparison of polypropylene and polyethylene terephthalate (Dacron) meshes for abdominal wall hernia repair: A chemical and morphological study. Hernia (2005) 9: 51 55 9. C.R. Costello, S.L. Bachman, B.J. Ramshaw, S.A. Grant. Materials Characterization of Explanted Polypropylene Hernia Meshes. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2007 10. Junge K.et al.: Elasticity of the abdominal wall and impact for reparation of incisional repairs using mesh implants. Hernia 2001 11. Gonzales et al. Resistance to adhesion formation: A comparative study of treated and untreated mesh products placed in the abdominal cavity. Hernia (2004) 8: 213 219 12. M. H. F. Schreinemacher et al. Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental model. British Journal of Surgery 2009; 96: 305 313 13. Christine Schug-Pass, Florian Sommerer, Andrea Tannapfel, Hans Lippert, Ferdinand Köckerling. The use of composite meshes in laparoscopic repair of abdominal wall hernias: are there differences in biocompatibily? Surg Endosc, 2008 14. Karsten Junge et al. Adhesion formation of a polyvinylidenfluoride/polypropylene mesh for intra-abdominal placement in a rodent animal model. Surg Endosc 2008 15. Michael J Rosen. Polyester-based mesh for ventral hernia repair: is it safe? The American Journal of Surgery (2009) 197, 353-359. COVIDIEN, COVIDIEN with logo and marked brands are trademarks of Covidien AG or its affiliate. 2010 Covidien AG or its affiliate. All rights reserved. Hernia 031-07-10 Tyco Healthcare Pty Ltd 166 Epping Road, Lane Cove NSW 2066 Australia (t) 1800 252 467 Tyco Healthcare Ltd Ground Floor, 15B Vestey Drive, Mount Wellington, Auckland New Zealand (t) 0508 489 264 www.covidien.com