Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Similar documents
Preparative HPLC columns Eurospher II for semipreparative and preparative HPLC

Analytical and Preparative SFC Columns

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Sepax Technologies, Inc.

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Agilent Technologies Prep LC Columns

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Ultra Columns. also available. ordering note

Restek Ultra II HPLC Columns

Ultra Columns HPLC COLUMNS

ACE C18-AR Use the Power!

C30 ISOMERS HAVE MET THEIR MATCH

InertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

KNAUER Column Selection Guide

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

Hyper-fast & Super-rugged

Application Note. Purification of ω-3-fatty acids from fish oil using MCSGP. Summary. Countercurrent chromatography, multicolumn.

YMC HILIC Columns for Polar Analytes

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

Thermo Scientific Hypersil BDS Columns

Chapter 22: Gas and Liquid Chromatography. Liquid Chromatography: Stationary Phases and Mobile Phases: Normal Phase: Reversed Phase:

SeQuant ZIC -HILIC For all who expect more...

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

SeQuant ZIC -HILIC For all who expect more...

LC Columns with Liquid Separation Cell Technology

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

HICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited

Am I getting the very best value from my UHPLC analyses?

Unequalled durability against water elution. % tr

HIGH PERFORMANCE SEPARATION PHASES

Fortis Method Development Options

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

The Raptor HILIC-Si Column

176 YMC Chiral Columns

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Roc On with These Dependable LC Columns

Normal Phase HPLC Column COSMOSIL SL-II

The LC Column Playbook

InertSustainBio C18. Rapid Separations of Proteins and Peptides

3 Normal-Phase Columns. Reversed-Phase C18 Columns (ODS) Reversed-Phase Columns (Other than ODS) Columns for HTS and LC/MS Analysis.

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Impurity Profiling of Carbamazepine by HPLC/UV

Kromasil The way to peak performance in liquid chromatography

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

Choosing Preparative Columns

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Catalogue. Resins and Columns For High Performance Liquid Chromatography

COSMOSIL HPLC Columns

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Ultimate Core Performance to Maximize Your Investment

Comparison of a UPLC Method across Multiple UHPLC Systems

YMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

GlycanPac AXR-1 Columns

YMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.

Dikma Technologies Inc.

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Reversed-Phase Columns (Other than ODS)

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Normal Phase Chemistries

YMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology

A New Era in SFC Column Technology

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Methotrexate. (Ph. Eur. monograph 0560) C 20 H 22 N 8 O Action and use. Dihydrofolate reductase inhibitor; cytostatic.

Waters Amide Column Technology For Food Analysis

ACE C18-AR. A C18 bonded phase with unique selectivity. Guaranteed reproducibility. Exceptional bonded phase stability

HPLC Application Notes

Gerry Hendrickx Regional Sales Manager Central Europe. Developments in Waters Column Chemistries : BEH Technology

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

GlycanPac AXH-1 Columns

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

HPLC Column for Structural Isomers COSMOSIL Cholester

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Physical Properties. Silica

IAM Chromatography. Introduction

2012 Waters Corporation 1

ACE Excel UHPLC Columns

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Dikma Technologies Inc.

HPLC Separation Tools for Membrane Protein Purification and Drug Membrane Permeability Prediction

Supra-Clean and Supra-Poly Solid Phase Extraction (SPE) Solutions

HPLC. Varian Dynamax Preparative HPLC Columns

2 Tosoh bioscience LLc. suite 100 king of Prussia, pa 19406, USA.

Studies on Stationary Phase Selectivity for Solid-Core Particles

Vitamin Analysis by HPLC

Transcription:

HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing material for a wide field of applications. ur next generation Eurospher II has been developed for an even wider range of application areas. Based on an ultra pure spherical silica gel, Eurospher II is a high performance column material for analytical, semipreparative and process-scale applications. Eurospher II features very narrow particle and pore size distributions, as well as outstanding mechanical stability. Eurospher II silica gel is perfectly suited to take on routine analyses as well as the most ambitious chromatography tasks. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > 99.99 % Metal content: < 1 ppm Particle size: µm, µm, 1 µm, (1 µm, µm upon request) Particle shape: spherical Pore size: 1 Å Specific surface: ± m /g Pore volume:.8 ml/g Density: g/l Eurospher II offers outstanding mechanical and chemical stability. With physical properties very similar to those of Kromasil 1, Eurospher II columns can be used to replace Kromasil columns, providing excellent peak symmetry for acids, bases, and neutrals.

HPLC SMB smometry Eurospher II is comparable with Kromasil and even outperforms it in some respects: nearly the same particle shape as Kromasil 1 Eurospher II has a lower metal impurity specification higher mechanical stability compared to Kromasil 1 comparable selectivity in P mode of Eurospher II C18 H and Kromasil 1 C18 Modifications With the wide range of different surface modifications available, all application fields in reversed phase and normal phase modes are covered. Every Eurospher II modification offers high chemical stability and loading capacity thanks to mono- and multi-functional silanes. With several different levels of endcapping, Eurospher II offers a wide variety of surface modification types for analytical as well as preparative columns. ur long experience and knowledge in producing HPLC columns ensures the highest reproducibility. Standard liquid endcapping (~ %) P P P H H H H H Si Si Si Si Si Si Si Si Si Si Si Si P: C 8 or C 18 chain High efficiency endcapping (~ 99 %) P P P Si Si Si Si Si Si Si Si Si Si Si Si In summary four different Eurospher II C18 types are now available. Eurospher II reversed phase columns are up to the challenge by delivering outstanding selectivity of positional isomers, steric isomers, and polar compounds. Modification USP code % carbon ph range C18 L1 1 % (~ % endcapping) 8 C18 H L1 17 % (> 99 % endcapping) 1 1 C18 P L1 % (~ 99 % endcapping) 1 1 C18 A L1 1 % (~ % hydrophilic endc.) 8 Phenyl L11 1 (~ % endcapping) 8 C8 L7 1 % (~ % endcapping) 8 C8 A L7 8 % (> % endcapping) 8 C L 7 % (~ % endcapping) 8 HILIC 7 % (no endcapping) 8 NH L8 % (no endcapping) 8 CN L1 7 % (no endcapping) 8 Diol L % (no endcapping) 8 Si L % (no endcapping) 8 Whether your application requires high ph or low ph conditions, Eurospher II C18 H and C18 P columns perform equally well.

Exellent batch-to-batch reproducibility Eurospher II 1- C18 H etention time reproducibility (SD) Terbinafine HCl.% Ibuprofen.7% Lovastatin.% Simvastatin.8% Batch 1 Batch Batch Batch Batch. 1.... 7. 9. 1. 1. 1. 1. Applications The choice of the appropriate column for a particular application can be a daunting task. With a range of bonded phases offering different selectivity, the Eurospher II family includes columns to meet most separation needs. The chart below will help you to choose the best Eurospher II column for a particular application. Phase type non polar polar acidic basic Chelator hydroph. retention shape selectivity extreme aqueous ph > 9 LC-MS C18 C18 H C18 P C18 A Phenyl C8 C8 A C HILIC NH CN Diol Si excellent good suitable not recommended 1... μm Comparable selectivities from µm to µm: The Eurospher and Bluespher column families Bluespher Eurospher family UHPLC HPLC HPLC / MPLC analytical semi-prep. preparative

Phenols: Eurospher II C18 P Steroids: Eurospher II C18 P 1 1 1 8 7 1 phenol -nitrophenol,-dinitrophenol -chlorophenol -nitrophenol,-dimethylphenol 7 -methyl-,-dinitrolphenol 8 -chloro--methylphenol 9,-dichlorophenol 1,,-trichlorophenol 11 pentachlorophenol i impurity 1 1 1 1 1 cortisone corticosterone desoxycorticosterone testosterone norgestrel progesterone 1 8 8 9 11 1 1-8 1 1 1 1 18 Column: Eurospher II 1- C18 P 1 x mm Mobile phase: A: water (+.1 % formic acid) B: methanol (+.1 % formic acid) Gradient: min % 9 % B; min hold Flow rate:. ml/min Temperature: C Detection: UV 8 nm Inj. volume: 1 μl - - 1 7 8 9 1 11 1 1 1 1 Column: Eurospher II 1- C18 P 1 x mm Mobile phase: A: water (+.1 % formic acid) B: methanol (+.1 % formic acid) Gradient: min % 9 % B; min hold Flow rate:. ml/min Temperature: C Detection: UV nm Inj. volume: 1 μl Additives: Eurospher II C18 Water soluble Vitamins: Eurospher II HILIC 1 1 acesulfam saccharin vanillin caffeine aspartame benzoic acid 7 sorbic acid 9 8 7 1 1 pyridoxal (vitamin B) folic acid (vitamin B9) ascorbic acid (vitamin C) nicotinic acid (vitamin B) thiamine (vitamin B1) cyanocobalamine (vitamin B1) 1 7 8 1 1 1 1 Column: Eurospher II 1- C18 1 x mm Mobile phase: A: mm KH P ; ph B: methanol Gradient: min 1 % % B 8 min % B 8 1 min % % B 1 1 min % B 1 18 min % 1% B Flow rate:. ml/min Temperature: C Detection: UV nm Inj. volume: μl 1-1,, 1, 1,,,,,,, Column: Eurospher II 1- HILIC 1 x mm Mobile phase: A: mm NH -acetate ph B: Acetonitrile Gradient:.7 min % A;.7 1. min % A; 1.. min % A Flow rate: 1. ml/min Temperature: C Detection: UV nm Inj. volume: 1 μl

A range of selectivities to fit your application C18 H 1.9 C18H H 11.8 C18P H 1. 1. 1.. 1..1. 1..1. 1.1.1.8 1.8 C18A H Phenyl H C8 H.9 1.. 1.7.1 1...71 1..1.97.11. 1.8 1.1 Selectivity plots for phases are based on Tanaka tests: H: hydrophobic retention : hydrophobic selectivity : steric selectivity : hydrogen bonding capacity : ion exchange capacity at ph 7. : ion exchange capacity at ph.7 Modification type Application areas Separation mechanism C18 C18 H C18 P C18 A Phenyl C8 C8 A C HILIC NH CN Diol Si for acidic, basic and neutral analytes in reversed phase mode (sulphonamides; anabolic steroids; anti-psychotics; beta blocker; Sudan dyes; phenols, preservatives etc.) recommended alternative for Kromasil 1 C18 columns; for acidic, basic and neutral analytes in reversed phase mode with extended ph range alternative selectivity to C18 phase; stationary phase in Eurospher II C18 family with the highest carbon load; fully endcapped; excellent shape selectivity and ph stability polar endcapped C18 phase for alternative selectivity; 1 % aqueous applications with very polar compounds (basic pharmaceutical ingredients, water soluble vitamins, catecholamines as well as organic acids) alternative selectivity for aromatic and mode rately polar analytes or mixtures with varying polarity and aromaticity similar selectivity to C18 phase but less retention due to the lower hydrophobicity; useful for determination of water soluble vitamins, steroids, catecholamines, sedatives etc. alternative selectivity to C8 with stronger s for polar compounds; 1 % aqueous applications with very polar compounds universal packing material for different application areas; can also be used in HIC mode (Hydrophobic Interaction Chromatography) especially suited for the separation of hydrophilic, polar and ionic analytes which are only poorly retained on reversed phase columns; behavior is the other way round on Eurospher II HILIC compared to P which makes it an ideal tool to enhance chromatographic separations for these molecules most flexible phase in the Eurospher II family; can be used in three modes: normal phase, reversed phase and ion chromatography mode (weak anion exchanger); different selectivity to the silica packing; in reversed phase mode mainly used for analysis of carbohydrates for a wide range of application in normal pase mode as well as reversed phase mode (steroids, carbohydrates polar compounds) alternative to the silica packing with shorter equilibration time and comparable selectivity; due to the lower activity of these packings it can be also used for SEC-applications wide range of different applications, i.e. SEC (size exclusion chromatography) but also for normal phase HPLC; good choice for analytical and preparative purposes to separate polar compounds hydrophobic hydrophobic hydrophobic and steric hydrophobic and polar pi-pi with aromatics reduced hydrophobic comparing to C18 phase hydrophilic and weak electrostatic hydrophobic and hydrophilic hydrophilic and weak electrostatic hydrophilic and ionic hydrophobic and hydrophilic hydrophilic hydrophilic

HPLC SMB smometry Column hardware We design and manufacture HPLC column hardware ranging from mm ID to mm ID under strict quality control. A specially treated inner surface ensures consistent column packing and high column stability. A wide range of column lengths from mm up to mm are available. An easily exchangeable inte grated precolumn for analytical columns is available upon request. rdering information E The last 7 digits of the rder No. comprise the stationary phase. E The first digits of the rder No. comprise the column dimensions. Eurospher II packing ecommended for analytical columns ecommended for preparative columns material µm µm 1 µm 1 µm µm C18...E181EG...E181EJ...E181EN...E181EQ...E181EX C18 H...E18EG...E18EJ...E18EN...E18EQ...E18EX C18 P...E18EG...E18EJ...E18EN...E18EQ...E18EX C18 A...E18EG...E18EJ...E18EN...E18EQ...E18EX Phenyl...EEG...EEJ...EEN...EEQ...EEX C8...E81EG...E81EJ...E81EN...E81EQ...E81EX C8 A...E8EG...E8EJ...E8EN...E8EQ...E8EX C...E1EG...E1EJ...E1EN...E1EQ...E1EX HILIC...E1EG...E1EJ...E1EN call call NH...E19EG...E19EJ...E19EN...E19EQ...E19EX CN...EEG...EEJ...EEN...EEQ...EEX Diol...E1EG...E1EJ...E1EN...E1EQ...E1EX Si...EEG...EEJ...EEN...EEQ...EEX For µm columns with comparable selectivities: www.knauer.net/bluespher Analytical and semipreparative columns ID mm mm mm. mm 8 mm 1 mm mm (precolumn) PB... PC... PD... PD... n.a. n.a. mm length B... C... D... E... G... I... mm length B... C... D... E... G... I... 1 mm length 1B... 1C... 1D... 1E... n.a. n.a. 1 mm length 1B... 1C... 1D... 1E... 1G... 1I... 1 mm length 1B... 1C... 1D... 1E... n.a. n.a. mm length B... C... D... E... G... I... mm length n.a. n.a. D... n.a. G... n.a. Preparative columns ID mm mm mm With axial compression mm (precolumn) P...... 1 mm length 1P... 1Q... 1... mm length P... Q...... All analytical column types from mm ID up to. mm ID are available with integrated precolumns. Kromasil is a brand name of EKA Chemicals AB. www.knauer.net/eurospherii Technical data are subject to change without notice. Visit www.knauer.net for details on complete HPLC systems, HPLC columns, and osmometers. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg 8 11 Berlin, Germany Phone: +9 8 97 7- Telefax: +9 8 1 1 E-Mail: info@knauer.net Internet: www.knauer.net Your local distributor: Printed on paper awarded the EU Ecolabel EU Ecolabel : FI/11/1 V77-1US/./.1/www.studio-w.net